Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #57004598

Tender For Repair/Maintenance Of Lift And Other Misc Works At 12 Wing (Af) Stn Chandigarh

Issued by Statutory Bodies & Commissions/Committees · Chandigarh, Chandigarh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Sep 2026
9 days left
EMD
27980
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Repair/Maintenance Of Lift And Other Misc Works At 12 Wing (Af) Stn Chandigarh

BOQ

Name of Work:- REPAIR/MAINTENANCE OF LIFT AND OTHER MISC WORKS AT 12 WING (AF) STN CHANDIGARH
Sl. No. Item Description
1M & L for comprehensive systematic maintenance and periodical inspection service of passenger lift of capacity 8 persons (installed at ATC building) by the trained and qualified technicians of M/s Thyssen Krupp Elevators India (OEM) by providing routine maintenance, examination, lubrication service according to recommended schedule of maintenance/ service by the OEM i.e. M/S Thyssen Krupp Elevator for once in a month during working hours (i.e. Monday to Saturday 0900 hours t0 1700 hours) except scheduled holidays to furnish the necessary lubricants and cleaning materials including the replacement of hydraulic fluid and machine gear oil of suitable grade etc. in addition to attending of annual government inspection complete all as specified.Note for item No. 1 :- The contractor will replace/ repair all the parts/ components free of cost ( through the OEM i.e.M/S Thyssen Krupp Elevator only) related to the normal working of the lift by replacing the defective spare parts ( except spare parts mentioned in Sl item No 3 to 6 here in after) to keep the lift in serviceable condtion as required at the time of inspection cum maintenance and for smooth functioning of Lift all as specified and as directed by the Engineer-in-charge.The unit rate quoted shall be deemed to include the cost of the same and no extra payment will be made on this account. However, Spare parts listed at Srl item No 3 to 8 after shall be measured and paid separately.
2M & L for comprehensive systematic maintenance and periodical inspection service of passenger lift of capacity 10 persons (installed at SRE building) by the trained and qualified technicians of M/s Johnson Elevator (OEM) by providing routine maintenance, examination, lubrication service according to recommended schedule of maintenance/ service by the OEM i.e. M/S Johnson Elevator Elevator for once in a month during working hours (i.e. Monday to Saturday 0900 hours t0 1700 hours) except scheduled holidays to furnish the necessary lubricants and cleaning materials including the replacement of hydraulic fluid and machine gear oil of suitable grade etc. in addition to attending of annual government inspection complete all as specified.Note for item No. 2 :- The contractor will replace/ repair all the parts/ components free of cost ( through the OEM i.e.M/S Johnson Elevator only) related to the normal working of the lift by replacing the defective spare parts ( except spare parts mentioned in Sl item No 9 to 14 here in after) to keep the lift in serviceable condtion as required at the time of inspection cum maintenance and for smooth functioning of Lift all as specified and as directed by the Engineer-in-charge.The unit rate quoted shall be deemed to include the cost of the same and no extra payment will be made on this account. However, Spare parts listed at Srl item No 9 to 14 after shall be measured and paid separately.
3M&L for LOP suitable for 08 Persons lift as per existing.
4M&L for COP suitable for 08 Persons lift as per existing.
5M&L in replacement VVVF drive as per existing or lift of make -Tyhssen Krupp Elevator
6M&L in replacement maint free lead acid battery 12 Volts 7 AH
7M&L for alignment of lift doors of Make-Tyhssen Krupp Elevator
8M&L in replcement cabin fan single phase 240 volts complete as per existing.
9M&L in replacement maint free lead acid battery 12 Volts 18 AH
10M&L for alignment of lift doors of Make-Johnson Elevator
11M&L for LOP suitable for 10 Persons lift as per existing.
12M&L for COP suitable for 10 Persons lift as per existing.
13M&L in replcement 25 Amps contactors 110 V DC as per existing
14M&L in replcement 32 Amps contactors CT1 as per existing
15M & L for cleaning of complete machine room, shaft area, lift car interior, refreshing main cable connections by providing new copper thimbles of size 25/35 sqmm on both ends & properly insulating, alignment & laying of cables/wires properly, checking of auto voice/audio system etc complete all as directed. Note - The job will be carried out twice during currency of the contract. The first one shall be done within 90 days from the date of commencement of work.
16M & L in replacement for copper strip 20 x 3 mm for roof conductors and down conductors mounted on and incl epoxy/porcelain insulators above ground complete all as directed.
17M & L in replacement for earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to copper strip earth lead of size 20 x 3 mm by means of bolts, nut check nuts and washers of brass, earth strip protected by galvanized steel pipe 40 mm bore (medium grade) connected to test point all as shown in electrical plate No. 3 of SSR - Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1;2:4), type B-1 reinforced XPM of weight not less than 4 Kg/Sqm and taking out unserviceable earthing etc, complete all as specified. Note - Copper strip 20 x 3 mm and GI protection pipe 40 mm dia upto a length of 7.5 mtr shall be deemed to be included in the unit rate quoted. Note - Old earthing may have been burried down to a depth of exceeding 2.25 mtr below ground level. No extra payment will be made if excavation is done beyong 2.25 mtr deep to retrieve the old earthing.
18Supply, installation, testing and commissioning in replacement of out door type double door (Fornt and rear side) panel board of CPRI Approved make with compartmentfloor mounting of suitable size , with locking arrangemant, fabricated out of 3.15 mm thick CRCA sheet and angle iron 50x50x6 mm size fro abse frame and for legs, 04 no Legs 750mm long, PCC 1:2:4 type B-1 for grounting , dully powder coated, dust/water & vermin proof, suitable for 415 volts 3 phase 50Hz, complete with and incl the following accessories :- (a) MCCB 4 Pole, 200 Amps capacity 35/36 KA 415 Volts with adjustable thermal & magnetic release -01 No (Incoming) and on load type change over swithc four pole 200 Amps 415 volts 50Hz-02 Nos. (b) Aluminium strip bus bars sleeve insulated and mounted on epoxy insulators. 300 amps capacity, TPN-01 Set.(c) MCCB 4 Pole, 200 Amps 35/36 KA 415 Volts-01 Nos (Incoming) and power connector FP 200 Amps 415 volts with coil volatage 240 volts-01 No with & incl analouge type timer switch with 96 slots of 15 minute each 240 volts 50 Hz with in biult backup-01 No (Ougoin). (d) Amp meter digital type 96x96mm size flush mounting ranges 0-200 amps with four way selector switch and 03 Nos CTs 200/5 Amps-01 No and voltameter meter digital type 96x96mm size flush mounting range 0-500 volts with four way selector switch-01 No.(e) Earthing terminal -02 Nos(f) Danger notice plate dully rivetted/pasted on front foor-01 No. (g) Internal wiring of the panel board circuits with copper conductor PVC insulated single core cable of suaiatble dia incl control MCB SP in each circuit.
19Notes for Ser item No 1&2(a) The contractor shall be submit the Memorandum of Understanding (MOU) on stamp paper duly notarized with orginal Equipments Manufacturer (OEM) as applicable as per specification to the effect and maintanance shall be carried out under OEM overall supervision and direction/ instruction within 15 days of acceptance of tender, failing which the contract will be liable to be cancelled.(b) Contractor shall attend and rectify the complaint/ fault within 24 hours as per the direction of AGE E/M / JE (E/M) / Users' rep and make the lift serviceable. Complaint will be given telephonically or through SMS. Contractor will provide his or his supervisor's moblile no for this purpose. A penality of Rs 200/- per hour will be levied upon the contractor for not attending the complaint after expiry of 24 hours period.(c) Bidders are advised to inspect site of work and condition of lift before quoting their rates in consultation with concern executives/OEMs.Nothing extra shall be admissible at any belated stage.(d) Original service report for each lift dully signed by OEM's technician and user's rep shall be submitted to Engr - in - Charge.
20Note: The Total amount shall subject to adjustment of credit of Rs.2750.00 for old Materials as per Schedule of Credit. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57004598
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 03-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Repair/Maintenance Of Lift And Other Misc Works At 12 Wing (Af) Stn Chandigarh
Basic Detail
Tender No CWE/AF CHD/CHD/T-32/2026-27
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 13 Aug 2026
Submission Date 03 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 27980
Exemption Not Available
Document List
BOQ_878736.xls
cea52250-fcef-4030-9083-394d7f2d47cf.html
T32Tenderdocuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_878736.xls

html

cea52250-fcef-4030-9083-394d7f2d47cf.html

pdf

T32Tenderdocuments.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders