Tender For Setting Up Of 30 Bedded Cornmunity Health Centre (Chc) At Sonamukhi Rh, Bishnupur Hd, Dist. Bankura - Electrical Lnstallation Work.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Aug 2026
15 days left
EMD
1.37 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bankura → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Setting Up Of 30 Bedded Cornmunity Health Centre (Chc) At Sonamukhi Rh, Bishnupur Hd, Dist. Bankura - Electrical Lnstallation Work.
BOQ
| Sl. No. | Item Description |
| 1 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire [Make:- Finolex/Havells/RR Kable / Polycab/Gloster/KEI] in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.Avg run 12 Mtr |
| 2 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire [Make:- Finolex/Havells/RR Kable / Polycab/Gloster/KEI] in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish (Onboard) |
| 3 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. Length. |
| 4 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. Length. |
| 5 | Supply & Delivery of Single LED Tube light fittings (make- Philips, Cat No. TMC-502 P1xT-LED 22W / equivalent model of CG Fittings- IGP161LT8-16 1 x T8 with 01 Nos LED TUBE Philips Cat No- Mas LED Tube 1200mm 18W 865 T8 I – 2100 lm /Crompton- Cat No- LTB-20-865-(2) or equivalent model of Havells/Wipro) |
| 6 | Supply & Delivery of twin LED Tube light fittings (Make- Signify (Philips), Cat No. TMC-502 2XT-LED 22W or equivalent model of CG Fittings- IGP162 LT8-16 2 x T8 with 02 Nos LED TUBE Philips Cat No- Mas LEDTube 1200mm 18W 865 T8 I – 2100lm /Crompton- Cat No- LTB-20-865-(2) or equivalent model of Havells/Wipro) |
| 7 | Supply and fixing of 36W Surface mounted 2ftx2ft LED CRCA housing, 6500k, > 2kV inbuilt Surge protection deviceon ceiling by means of fastner. (Make: Phillips (Signify) Cat No. SM367 LED36S-6500 G6 L54W54 PSU OD or equivalent model of Crompton/Wipro ) |
| 8 | Supply and fixing of 36W Recess mounted 2ftx2ft LED, 6500k, > 2kV inbuilt Surge protection device, fixed on ceiling by means of MS fastner and GI chain. (Make: Phillips (Signify) Cat No. RC380B LED 36S-6500 G6 L60W60 PSU OD S1 or equivalent model of Crompton/Wipro ) |
| 9 | Supply and fixing of 10W LED Bulkhead with IP65 protection, > 2kV inbuilt Surge protection device, housing made of pressure die cast . (Make: Phillips (Signify) Cat No. WT202W LED10S CW PSU or equivalent model of Crompton/Wipro ) |
| 10 | Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. |
| 11 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 12 | Supply & delivery of AC 240V 50 Hz 48\\" sweep (1200 mm) ceiling fan complete with down rod, Canopy, fork incl S & F of P - 2 type capacitor as per IS specification & proper Manufacturer certificate of the capacitor and Safety Wire (supplied at the time of delivered the fans ) etc. without regulator, (Make- Usha 1200MM STRIKER PWD ISI 1 STAR (Safety Wire & S3 Capacitor) Br /Orient Electric- New Breeze (5yrs warranty),1200 mm sweep; 44W; 320 rpm; 225 cmm; 3 star ac ceiling fan or equivalent model of Crompton Greaves and as per direction of EIC as per direction of EIC. |
| 13 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. Length |
| 14 | Supply and Delivery of 230 V, 50 HZ, 450 mm, metal blades and metal canopy, Wall Bracket fan operated by pull cord switch with inbuilt regulator. ( Make:- Crompton Cat No- 450mm SSTORM 2 Plus (Metal Body and Metal Canopy) /Orient Electric /USHA) |
| 15 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter(12inch) |
| 16 | Fixing only cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long)(12 inch) |
| 17 | Supply and delivery of of 300mm/12\\", 920RPM , 48 Watt, heavy duty full metal body exhaust fan. (Make: EPC ) |
| 18 | Supply & Fixing 240 V, 02 Nos. 6A, plug socket with separate 2no 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200 mm x 150 mm x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. |
| 19 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 20 | Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 21 | Supply & Fixing 240 V, 3 nos. 20A plug socket with separate 3 nos. 20A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 300x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 22 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 23 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 24 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc |
| 25 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. |
| 26 | Supplying and fixing Timer box 16way SNDB . fixed in wallon flate iron frame as per direction EIC.The Box shuld comprising following accessorise. A) Digital Timer Switch. (Make: GIC Cat No. WT1SCDS/ Legrand /Siemens) --- 01 Nos. B) 2 Pole Power Contrcator (Make: LK(L&T) MNX 32 Cat No-CS90241/Legrand /Siemens) C) 2 pole 32 Amps MCB (Make: LK(L&T)/Legrand/ABB) - 01 Nos D) Auto / Manual By pass Toggle Switch arrangement – 01 Nos. E) 250 V LED Indicator lamp – 01 Nos F) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar , with spring washer ,nuts etc with this box for termination of power to complete arrangement must be wiring by 6/4/2.5/1.5 Sq.mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (for controlling outdoor street light) (Make:- LK(L&T)/Legrand/ABB/Siemens) |
| 27 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(2+14way) [ Make:- Legrand/Schneider/Siemens/LK(L&T)] |
| 28 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment(6 Way) [ Make:- Legrand/Schneider/Siemens/LK(L&T)] |
| 29 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 6 way [ Make:- Legrand/Schneider/Siemens/LK(L&T)] |
| 30 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. [ Make:- Legrand/Schneider/Siemens/LK(L&T)] |
| 31 | 6-32A SPMCB |
| 32 | 40A DPMCB |
| 33 | 63A TPMCB |
| 34 | 63A FPMCB |
| 35 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. [ Make:- Legrand/Schneider/Siemens/LK(L&T)] |
| 36 | Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. [ Make:- Legrand/Schneider/Siemens/LK(L&T)/ABB or as per the dicrection of EIC] |
| 37 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes. [Make:- Finolex/Havells/RR Kable / Polycab/Gloster/KEI] |
| 38 | 3 x 22/0.3 (1.5 sqmm) |
| 39 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 40 | 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC |
| 41 | 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC |
| 42 | 4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC |
| 43 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 44 | 2.5sqmm |
| 45 | 4sqmm |
| 46 | 6sqmm |
| 47 | Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works. 19 mm dia 3 mm thick polythene pipe without earth continuity wire. |
| 48 | Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works. 25 mm dia 3 mm thick polythene pipe without earth continuity wire. |
| 49 | Supply and delivery of 1.1 kv grade al/A XLPE/PVC cable of following sizes. [Make:- Finolex/Havells/RR Kable / Polycab/Gloster/KEI] |
| 50 | 2 core 10 sqmm |
| 51 | 4 core 35 sqmm |
| 52 | 4core 50 sqmm |
| 53 | 4 core 70 sqmm |
| 54 | 4 core 240 sqmm |
| 55 | Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. |
| 56 | Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support(300x50x1.25mm(18SWG)) |
| 57 | Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. |
| 58 | Up to 50 sqmm |
| 59 | From 70sqmm to 150sqmm |
| 60 | Laying of two cables above 185 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed |
| 61 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below |
| 62 | 2 core 10 sqmm |
| 63 | 4 core 35 sqmm |
| 64 | 4core 50 sqmm |
| 65 | 4 core 70 sqmm |
| 66 | 4 core 240 sqmm |
| 67 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 68 | 2 core 10 sqmm |
| 69 | 4 core 35 sqmm |
| 70 | 4core 50 sqmm |
| 71 | 4 core 70 sqmm |
| 72 | 4 core 240 sqmm |
| 73 | Supply & Delivery 3\\" dia. 2 Mtr. Long heavy gauge G.I. Pipe (minipole) having M.S. sole plate welded with drilled hole at bottom of the pole to be installed on roof of building incl. providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. Supply & fixing 50mm Dia 2mtr long detachable type GI Single arm bracket suitable incl. s&f of 50x40mm reducer for the pole head.The arm brfacket shall be properly welded with 15mm thick stifner plate of pole sleeve for strengthening including properly fixing arfangement with the pole by bolt , nut, wahser as per direction of EIC including 2coat aluminium paint after Primer( ROOF TOP LIGHT) |
| 74 | S&f of 240V 50HZ, 11000 Lumen or above output Street light IP66 protection with IK09 rated on pole with efficacy of 120lumen/watt inbuilt surge protection device upto 4kV(make:- Siginify ( Phillips Cat No. BRP333 LED110 CW R5C FG PSU S1 V1 /Crompton CRP 411-100-30-SL-GL-NSG/Wipro) |
| 75 | Supplying & Fixing SMC waterproof type looping cable box comprising of one 250 V 15 A kit-kat fuse unit,1 no three phase star connector, one NL on porcelain insulator, including socketing og cable terminals and two compression type brass cable gland for upto 4- core 16 sqmm PVC/A cable and having lined with rubber gasketted SMC top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.[Sintex make] |
| 76 | S& drawing from loop box to fitting by 3x1.5 sq. mm PVC insulated copper wire (Finolex 'FR') through 13 mm/19 mm dia 3mm thick Polythene pipe. [Make:- Finolex/Havells/RR Kable / Polycab/Gloster/KEI] |
| 77 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.(TATA Medium) |
| 78 | Excavation of morrum soil for installation of Earth Electrode and filling & ramming. |
| 79 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required |
| 80 | Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 81 | Connecting the equipments to earth busbar including S & F 4 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages |
| 82 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 83 | S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) |
| 84 | Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works |
| 85 | Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work |
| 86 | Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required |
| 87 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run |
| 88 | SITC OF CPRI-APPROVED FLOOR-MOUNTED INDOOR TYPE CUBICAL LT DISTRIBUTION PANEL:1) Supply, Installation, Testing and Commissioning (SITC) of CPRI-approved, floor-mounted, indoor type cubical LT Distribution Panel, suitable for 3-phase, 4-wire, 400/415 V, 50 Hz AC supply, designed for a short-circuit withstand/fault level of 31 MVA at 415 V, complete in all respects as per the approved design, electrical schematic and constructional drawing.2) The panel shall be of floor-mounted, compartmentalised, cubical type, fabricated by a CPRI-approved/empanelled manufacturer/fabricator, and shall comply with the relevant provisions of IS 8623 (Part 1):1993 / IEC 61439-1 & IEC 61439-2, with latest amendments, as applicable to the panel.Panel Construction:-1) The panel shall be fabricated from 2 mm thick MS sheet, suitably stiffened with MS Angle 75 × 40 × 5 mm and MS Flat 50 × 6 mm, wherever required for adequate mechanical strength.2) The panel shall be floor-mounted, self-supporting, cubical and suitable for indoor installation.3) The base frame/base plate shall be fabricated from 5 mm thick MS plate.4) The panel shall be provided with suitable doors/covers, hinges, locking arrangements, cable entry/termination arrangements and removable gland plates.5) The enclosure shall have suitable surface treatment and approved powder-coating/painting system for indoor installation. |
| 89 | Internal Segregation and Arrangement: i) The panel shall be suitably compartmentalised for safe operation and maintenance.ii) The panel shall be divided into two separate sections, namely Normal and Emergency sections, with separate busbar sections for each.iii) The outgoing feeder switches/protective devices shall be distributed between the Normal and Emergency sections as indicated in the approved electrical drawing.iv) Suitable segregation/shrouding shall be provided for busbars and live parts to prevent accidental contact.v) All internal components, supports, busbars, wiring and accessories shall be suitably rated for the specified voltage, fault level and load. |
| 90 | 4. Drawings and Approval: Before commencement of fabrication, the contractor shall submit the following to the Engineer-in-Charge (EIC) for approval:1) Panel General Arrangement/Constructional Drawing, showing overall dimensions, sections/compartments, busbar arrangement, component mounting, cable entry/termination and internal layout.2) Electrical Schematic/Single Line Diagram, clearly indicating the Normal and Emergency sections, incoming and outgoing feeders, busbars, switching/protection arrangements and interconnections.3) Details of the proposed CPRI-approved/empanelled manufacturer/fabricator.4) Fabrication of the panel shall not be commenced without approval of the constructional and electrical drawings by the EIC. |
| 91 | 5. CPRI Approval and Testing:-The contractor shall submit a valid CPRI approval/type-test certificate and relevant test documents for the proposed panel/design/manufacturer, as applicable, for verification by the EIC before acceptance of the panel. Please Enable Macros to View BoQ information |
| 92 | 5. CPRI Approval and Testing:-The contractor shall submit a valid CPRI approval/type-test certificate and relevant test documents for the proposed panel/design/manufacturer, as applicable, for verification by the EIC before acceptance of the panel. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender