Drinking Water Supply and Sanitation Government Departments Closing in 16 days TDR #57003288

Tender For Repairing Of No-4 Actuator Starter, Actuator Operated Butterfly Valve For Delivery Side Of Centrifugal Pump No-1 & 3, Eplacement Of Damaged Ups For Level Indicator At Amdohi Boosting Station Under Jamgara-Jagannathpur W/S Scheme.

Issued by Government Departments · Paschim Bardhaman, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Aug 2026
16 days left
EMD
7000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Paschim Bardhaman → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repairing Of No-4 Actuator Starter, Actuator Operated Butterfly Valve For Delivery Side Of Centrifugal Pump No-1 & 3, Eplacement Of Damaged Ups For Level Indicator At Amdohi Boosting Station Under Jamgara-Jagannathpur W/S Scheme.

BOQ

Name of Work:- Repairing of No-4 actuator starter, actuator operated butterfly valve for delivery side of centrifugal pump no-1 & 3, eplacement of damaged UPS for level indicator at Amdohi Boosting Station under Jamgara-Jagannathpur W/S scheme.
Sl. No. Item Description
1Actuator starter repairing portion:-
29 Amp, 3 Pole power contactor, 415 V AC, 50 Hz, with 1 No auxiliary contact block, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1.(Make:- L & K, Type No-MNX 9, Cat No-CS94106/Other approved make)
32 NO+ 2 NC auxiliary add on contact block for 240 V AC control voltage.(Make:-L & K, Type No-MCX 01-22, Cat No-CS91107/Other approved make)
4Thermal overload relay range from 3-5 Amp, ambient temperature compensated up to 55° C, built-in single phasing protection, manual and auto reset mode, conforms IS/IEC 60947-4-1 & IEC 60947-4-1.(Make:-L & K, Type No-MN2, Cat No-SS94141OOSO)
5Kit for Mounting MN-2 Relay separately (Direct Mounting Type)(Make:- L & K, Cat No-SS94700OOOO)
6Ø22.5 mm LED indicaor operating voltage-240 VAC, low power consumption < 1W, surge & low voltage glow protection (LVGP).(Make:-L & K, Cat No-EPL)
71.5 Sqmm PVC insulated(Un-sheathed) FR-LSH Cu wire single core multi strand 1.1 KV grade as per IS:694.(Make:-Polycab/Gloster/Other approved make)(For Control Circuit)
82.5 Sqmm PVC insulated(Un-sheathed) FR-LSH Cu wire single core multi strand 1.1 KV grade as per IS:694.(Make:-Polycab/Gloster/Other approved make)(For Control Circuit)
9Pin/ring type socket, lugs, PVC chanels, etc.
10Atfirst disconnection of all power line.Then fixing the above supplied materials at same place, then making power & control circuit wiring through out the local push button/starter work must be done by Experienced electrician and wholly satisfaction of EIC.
11Actuator repairing portion- 1 & 3 centrifugal pump's delivery line:-
12Worm shaft as per actuator specification.
13Limit switch drive as per actuator specification.
14Centre column as per actuator specification.
15Burnout motor rewinding.
164 Pole, AC-3 duty power contactor, 25 Amp, operating voltage-240 V AC.(Make:-Eaton, Model No:-XCTD-012)
17Power model.
18Worm wheel.
19Oil seal.
20Atfirst removing worm shaft, wheel, power related equipments from the actuator then fitting, fixing the new one also functioning all actuator operated butterfly valve at the delivery line, as per direction of EIC.
21Level indicator UPS change:-
22Uninterruptible Power Supply (UPS) as per IS 16242 (part-1) with overload protection, micro controller based, boost & buck AVR having following specification:- Capacity- 600VA / 360W, Input- 230V AC, Single phaseFrequency- 50/60Hz; Out put- 230V+/- 10% (AC mode)(Schneider :-APC-Back UPS) (BX600C-IN) (For Level indicator), atfirst removing of the damaged UPS from the power plug then placed new one, supply power via this.
23Centrifugal pump starter No-03:-
2463 Amp, 3Pole, AC-3 duty Molded cased circuit breaker, breaking capacity-36 kA with microprocessor based tripping unit, 415 V AC, 50 Hz.(Make:-Siemens, Type No-3VA2063-4HL32-0AA0)
251NO+1NC configuration auxiliary switch.(Make:- Siemens, Type No-3KJ9001-1AB00)
26At first remove the damaged MCCB, auxiliary contact block etc from the existing panel after disconnection of all power line.Then fixing the above supplied materials at same place, then making power & control circuit wiring through out the panel work must be done by Experienced electrician and wholly satisfaction of EIC.
27Add GST @ 18%
28Add CESS @ 1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57003288
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 31-08-2026
Authority
Authority Name Public Health And Engineering Department
Work Description Tender for Repairing Of No-4 Actuator Starter, Actuator Operated Butterfly Valve For Delivery Side Of Centrifugal Pump No-1 & 3, Eplacement Of Damaged Ups For Level Indicator At Amdohi Boosting Station Under Jamgara-Jagannathpur W/S Scheme.
Basic Detail
Tender No WBPHED/EE/AMD/ NIeT-24 of 2026-2027
Bidding Type Tender
Location
City Paschim Bardhaman
State West Bengal
Key Dates
Publish Date 13 Aug 2026
Submission Date 31 Aug 2026
Open Date 02 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 7000
Exemption Not Available
Document List
Tendernotice_1 (19).pdf
Tendernotice_2 (3).pdf
Tendernotice_3.pdf
87606c52-94dc-463a-b8c2-885f413f9422.html
BOQ_2549639.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Sep 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1 (19).pdf

pdf

Tendernotice_2 (3).pdf

pdf

Tendernotice_3.pdf

html

87606c52-94dc-463a-b8c2-885f413f9422.html

xls

BOQ_2549639.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders