Banking and Finance Government Departments Closing in 9 days TDR #56999815

Bids Are invited for Sitc Of Split And Casette Acs At Dcm Building Barakhamba Road Delhi

Issued by Government Departments · Delhi, Delhi
Tender Value
6.97 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
9 days left
EMD
13950
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
241

Project Description

Bids Are invited for Sitc Of Split And Casette Acs At Dcm Building Barakhamba Road Delhi Split Ac - Supply Of 1.0 Tr Bee 5 Star Rated Hi-Wall Split Air Conditioner , Casette Ac - Supply Of 1.5 Tr Bee 5 Star Rated 4 Way Cassette Ac , Casette Ac - Supply Of 3.0 Tr Bee 5 Star Rated 4 Way Cassette Ac , Installation And Commissioning - Installation And Commissioning Of 1.0 Tr Hi-Wall Split Air Conditioner Units Supplied As Above, Using Brackets, Fasteners, Any Accessories As Required, To The Correct Alignment Ensuring Proper Flow Of Condensate Water And Proper Cooling. , Outdoor Stand - Supply And Installation Of Floor / Wall Mounted Outdoor Stand For 1.0 Tr Hi-Wall Split Air Conditioner, Complete With Anchor / Dash Fasteners And Anti-Vibration Rubber Pad. , Referigent Piping - Supply And Laying Of Copper Refrigerant Piping (Liquid And Gas) Of Size As Per Manufacturers Specifications With Foiled Nitrile Rubber Insulation Complete With All Accessories Such As Bends, Elbows, Unions, Etc., Brazing/Soldering, Cl Ing/Binding With Suitable Tie Knots, Providing Insulation Etc. Including End Connections With Flare Nut / Brazing As Per Manufacturers Specifications And Suspension Of Piping From Ceiling Using Hangars For 1.0 Tr Hi-Wall Split Air Conditioner. (Excluding Piping In Standard Kit) , Interconnecting Cable - Supply And Laying Of Interconnecting Cable Between Indoor And Outdoor Unit For 1.0 Tr Hi-Wall Split Ac As Per Manufacturer Recommendations , Installation And Commissioning - Installation And Commissioning Of 1.5 Tr Cassette Air Conditioner Units Supplied As Above, Using Brackets, Fasteners, Any Accessories As Required , Outdoor Stand - Supply And Installation Of Wall / Floor Mounted Outdoor Stand For 1.5 Tr Cassette Air Conditioner, Complete With Anchor / Dash Fasteners And Anti-Vibration Rubber Pad. , Referigent Piping - Supply And Laying Of Copper Refrigerant Piping (Liquid And Gas) Of Size As Per Manufacturers Specifications With Foiled Nitrile Rubber Insulation Complete With All Accessories Such As Bends, Elbows, Unions, Etc., Brazing/Soldering, Cl Ing/Binding With Suitable Tie Knots, Providing Insulation Etc. Including End Connections With Flare Nut / Brazing As Per Manufacturers Specifications And Suspension Of Piping From Ceiling Using Hangars For 1.5 Tr Cassette Air Conditioner , Interconnecting Cable - Supply And Laying Of Interconnecting Cable Between Indoor And Outdoor Unit For 1.5 Tr Cassette Air Conditioner As Per Manufacturer Recommendations. , Installation And Commissioning - Installation And Commissioning Of 3.0 Tr Cassette Air Conditioner Units Supplied As Above, Using Brackets, Fasteners, Any Accessories As Required , Outdoor Stand - Supply And Installation Of Wall / Floor Mounted Outdoor Stand For 3.0 Tr Cassette Air Conditioner, Complete With Anchor / Dash Fasteners And Anti-Vibration Rubber Pad. , Referigent Piping - Supply And Laying Of Copper Refrigerant Piping (Liquid And Gas) Of Size As Per Manufacturers Specifications With Foiled Nitrile Rubber Insulation Complete With All Accessories Such As Bends, Elbows, Unions, Etc., Brazing/Soldering, Cl Ing/Binding With Suitable Tie Knots, Providing Insulation Etc. Including End Connections With Flare Nut / Brazing As Per Manufacturers Specifications And Suspension Of Piping From Ceiling Using Hangars For 3.0 Tr Cassette Air Conditioner , Interconnecting Cable - Supply And Laying Of Interconnecting Cable Between Indoor And Outdoor Unit For 3.0 Tr Cassette Air Conditioner As Per Manufacturer Recommendations. , Drainpipe - Supply And Laying 25 Mm Pvc Condensate Drainpipe With Nitrile Insulation Complete With Bends, Tees, Elbows Etc , Drainpipe - Supply And Laying 32 Mm Pvc Condensate Drainpipe With Nitrile Insulation Complete With Bends, Tees, Elbows And Making Connection To Cassette / Split Ac Unit With Flexible Connector. , Timer - Supply And Installation Of Timer Unit For Alternate Operations Of Ac Units Installed At Server Room Complete With 20A Plug Top

BOQ

Sl. No. Item TitleItem Description
1Split ACSupply of 1.0 TR BEE 5 Star rated Hi-Wall Split Air conditioner
2Casette ACSupply of 1.5 TR BEE 5 Star rated 4 way cassette AC
3Casette ACSupply of 3.0 TR BEE 5 Star rated 4 way cassette AC
4Installation and commissioningInstallation and commissioning of 1.0 TR Hi-Wall Split Air conditioner units supplied as above, using brackets, fasteners, any accessories as required, to the correct alignment ensuring proper flow of condensate water and proper cooling.
5Outdoor StandSupply and Installation of floor / wall mounted outdoor stand for 1.0 TR Hi-Wall Split Air conditioner, complete with anchor / dash fasteners and anti-vibration rubber pad.
6Referigent pipingSupply and laying of copper refrigerant piping (liquid and gas) of size as per manufacturers specifications with foiled nitrile rubber insulation complete with all accessories such as bends, elbows, unions, etc., brazing/soldering, clamping/binding with suitable tie knots, providing insulation etc. including end connections with flare nut / brazing as per manufacturers specifications and suspension of piping from ceiling using hangars for 1.0 TR Hi-Wall Split Air conditioner. (excluding piping in standard kit)
7interconnecting cableSupply and laying of interconnecting cable between indoor and outdoor unit for 1.0 TR Hi-Wall Split AC as per manufacturer recommendations
8Installation and commissioningInstallation and commissioning of 1.5 TR cassette Air conditioner units supplied as above, using brackets, fasteners, any accessories as required
9Outdoor StandSupply and Installation of wall / floor mounted outdoor stand for 1.5 TR Cassette Air conditioner, complete with anchor / dash fasteners and anti-vibration rubber pad.
10Referigent pipingSupply and laying of copper refrigerant piping (liquid and gas) of size as per manufacturers specifications with foiled nitrile rubber insulation complete with all accessories such as bends, elbows, unions, etc., brazing/soldering, clamping/binding with suitable tie knots, providing insulation etc. including end connections with flare nut / brazing as per manufacturers specifications and suspension of piping from ceiling using hangars for 1.5 TR Cassette Air conditioner
11interconnecting cableSupply and laying of interconnecting cable between indoor and outdoor unit for 1.5 TR Cassette Air conditioner as per manufacturer recommendations.
12Installation and commissioningInstallation and commissioning of 3.0 TR cassette Air conditioner units supplied as above, using brackets, fasteners, any accessories as required
13Outdoor StandSupply and Installation of wall / floor mounted outdoor stand for 3.0 TR Cassette Air conditioner, complete with anchor / dash fasteners and anti-vibration rubber pad.
14Referigent pipingSupply and laying of copper refrigerant piping (liquid and gas) of size as per manufacturers specifications with foiled nitrile rubber insulation complete with all accessories such as bends, elbows, unions, etc., brazing/soldering, clamping/binding with suitable tie knots, providing insulation etc. including end connections with flare nut / brazing as per manufacturers specifications and suspension of piping from ceiling using hangars for 3.0 TR Cassette Air conditioner
15interconnecting cableSupply and laying of interconnecting cable between indoor and outdoor unit for 3.0 TR Cassette Air conditioner as per manufacturer recommendations.
16DrainpipeSupply and Laying 25 mm PVC Condensate Drainpipe with nitrile insulation complete with bends, tees, elbows etc
17DrainpipeSupply and Laying 32 mm PVC Condensate Drainpipe with nitrile insulation complete with bends, tees, elbows and making connection to cassette / split ac unit with flexible connector.
18TimerSupply and Installation of Timer Unit for alternate operations of AC Units installed at server room complete with 20A plug top

AI Tender Summary

OUR REF NO 56999815
AUTHORITY Government Departments
TENDER VALUE 6.97 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name Punjab National Bank
Work Description Bids Are invited for Sitc Of Split And Casette Acs At Dcm Building Barakhamba Road Delhi Split Ac - Supply Of 1.0 Tr Bee 5 Star Rated Hi-Wall Split Air Conditioner , Casette Ac - Supply Of 1.5 Tr Bee 5 Star Rated 4 Way Cassette Ac , Casette Ac - Supply Of 3.0 Tr Bee 5 Star Rated 4 Way Cassette Ac , Installation And Commissioning - Installation And Commissioning Of 1.0 Tr Hi-Wall Split Air Conditioner Units Supplied As Above, Using Brackets, Fasteners, Any Accessories As Required, To The Correct Alignment Ensuring Proper Flow Of Condensate Water And Proper Cooling. , Outdoor Stand - Supply And Installation Of Floor / Wall Mounted Outdoor Stand For 1.0 Tr Hi-Wall Split Air Conditioner, Complete With Anchor / Dash Fasteners And Anti-Vibration Rubber Pad. , Referigent Piping - Supply And Laying Of Copper Refrigerant Piping (Liquid And Gas) Of Size As Per Manufacturers Specifications With Foiled Nitrile Rubber Insulation Complete With All Accessories Such As Bends, Elbows, Unions, Etc., Brazing/Soldering, Cl Ing/Binding With Suitable Tie Knots, Providing Insulation Etc. Including End Connections With Flare Nut / Brazing As Per Manufacturers Specifications And Suspension Of Piping From Ceiling Using Hangars For 1.0 Tr Hi-Wall Split Air Conditioner. (Excluding Piping In Standard Kit) , Interconnecting Cable - Supply And Laying Of Interconnecting Cable Between Indoor And Outdoor Unit For 1.0 Tr Hi-Wall Split Ac As Per Manufacturer Recommendations , Installation And Commissioning - Installation And Commissioning Of 1.5 Tr Cassette Air Conditioner Units Supplied As Above, Using Brackets, Fasteners, Any Accessories As Required , Outdoor Stand - Supply And Installation Of Wall / Floor Mounted Outdoor Stand For 1.5 Tr Cassette Air Conditioner, Complete With Anchor / Dash Fasteners And Anti-Vibration Rubber Pad. , Referigent Piping - Supply And Laying Of Copper Refrigerant Piping (Liquid And Gas) Of Size As Per Manufacturers Specifications With Foiled Nitrile Rubber Insulation Complete With All Accessories Such As Bends, Elbows, Unions, Etc., Brazing/Soldering, Cl Ing/Binding With Suitable Tie Knots, Providing Insulation Etc. Including End Connections With Flare Nut / Brazing As Per Manufacturers Specifications And Suspension Of Piping From Ceiling Using Hangars For 1.5 Tr Cassette Air Conditioner , Interconnecting Cable - Supply And Laying Of Interconnecting Cable Between Indoor And Outdoor Unit For 1.5 Tr Cassette Air Conditioner As Per Manufacturer Recommendations. , Installation And Commissioning - Installation And Commissioning Of 3.0 Tr Cassette Air Conditioner Units Supplied As Above, Using Brackets, Fasteners, Any Accessories As Required , Outdoor Stand - Supply And Installation Of Wall / Floor Mounted Outdoor Stand For 3.0 Tr Cassette Air Conditioner, Complete With Anchor / Dash Fasteners And Anti-Vibration Rubber Pad. , Referigent Piping - Supply And Laying Of Copper Refrigerant Piping (Liquid And Gas) Of Size As Per Manufacturers Specifications With Foiled Nitrile Rubber Insulation Complete With All Accessories Such As Bends, Elbows, Unions, Etc., Brazing/Soldering, Cl Ing/Binding With Suitable Tie Knots, Providing Insulation Etc. Including End Connections With Flare Nut / Brazing As Per Manufacturers Specifications And Suspension Of Piping From Ceiling Using Hangars For 3.0 Tr Cassette Air Conditioner , Interconnecting Cable - Supply And Laying Of Interconnecting Cable Between Indoor And Outdoor Unit For 3.0 Tr Cassette Air Conditioner As Per Manufacturer Recommendations. , Drainpipe - Supply And Laying 25 Mm Pvc Condensate Drainpipe With Nitrile Insulation Complete With Bends, Tees, Elbows Etc , Drainpipe - Supply And Laying 32 Mm Pvc Condensate Drainpipe With Nitrile Insulation Complete With Bends, Tees, Elbows And Making Connection To Cassette / Split Ac Unit With Flexible Connector. , Timer - Supply And Installation Of Timer Unit For Alternate Operations Of Ac Units Installed At Server Room Complete With 20A Plug Top
Basic Detail
Tender No GEM/2026/B/7913562
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 13 Aug 2026
Submission Date 24 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value 6.97 Lakhs
Tender Fee Ref. Documents
EMD 13950
Exemption Available
Document List
ATC_48376c5e-0b7a-4a35-997d1786623095993_Tanya.Goel.pdf
technical_specifications_for_ac_2026-08-13-13-20-18_c770a871bbf421800c8c2f54658b5ecd.pdf
194bb922-45fe-4264-953d-12918501d575.pdf
9751416_Boq_1.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
Goel

ATC_48376c5e-0b7a-4a35-997d1786623095993_Tanya.Goel.pdf

pdf

technical_specifications_for_ac_2026-08-13-13-20-18_c770a871bbf421800c8c2f54658b5ecd.pdf

pdf

194bb922-45fe-4264-953d-12918501d575.pdf

xlsx

9751416_Boq_1.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders