Tender for Certain E/M Special Repair/ Replacement , Ber Replacement Works At For Otm Accomodation Of Navy Area And Building Number P-27 Under Ge Haddo, Sri Vijaya Puram
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed. |
| 2 | Taking down existing unserviceable main switches/ distribution boards/Fuse Units of any description alongwith MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. |
| 3 | Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. |
| 4 | M & L point wiring for One light/fan point controlled by one modular switch 5 Amps one way complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVC insulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealed in walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified and as directed.Make of wire : V-Marc/Polycab/ Gloster/ Anchor/ Havells/ Finolex and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab.Note :- The unit rate quoted shall deemed to include the cost of following :-(a) GI metal flush box of minimum thickness of 1.6mm and modular cover plate with frame of any module complete.(b) Proper colour coding is to be followed as per IS specification.(c) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.(d) Cutting chases in wall/floor /beam/ceiling to be concealed conduit and making good the disturbed surfaces. |
| 5 | Description same as per item Sl No.04 above but for two light point controlled by one switch 5 Amps one way complete all as specified and directed.. |
| 6 | All as per item Ser No.04 above but for one modular 3 pin 5 Amp socket out let on independent board complete all as specified and directed |
| 7 | All as per item Ser No.04 above but for one modular 3 pin 5 Amps socket outlet on same Board complete all as specified and directed |
| 8 | All as per item Ser No.04 above but point wiring with 4.0 sqmm PVC FRLSH insulated multistranded copper conductor suitable for one 3 pin 16 Amps socket out let and one run of 4.0 sqmm cable for earth in green colour on independent board complete all as specified and directe |
| 9 | S & F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed. Make : Roma (Anchor)/ Legrand/ Havells |
| 10 | S&F socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed.Make : Roma (Anchor)/ Legrand/ Havells |
| 11 | S&F for switch modular type, 16 Amps 1 module, 230 volts AC circuit complete all as specified and directed Make : Roma (Anchor)/ Legrand/ Havells |
| 12 | S&F Socket outlet 2 in 1 modular type, 3 pin, 6 and 16 Amp , universal complete all as specified and directed.Make : Roma (Anchor)/ Legrand/ Havells |
| 13 | S & F Ceiling rose, surface polycarbonate body 65x50mm, two to three terminal complete all as specified and directed. Make : Anchor/ Legrand/ Havells |
| 14 | Supply & fix Modular Ac Box With 20A DP MCB \\"C' Type, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top, 240 volts AC supply for air conditioner, flush mounting in the wall complete all as specified and directed. Make:- Anchor (Roma) Model No 98492 or equivalent |
| 15 | S & F in repairs and testing Tube light fittings aluminium tubes 22 watts 4 feet including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed.Make: Luker Cat Part No : LT522 or equivalent to CG/Philips Havells |
| 16 | S & F in repairs GI brackets of GI pipe light grade of size 25 mm dia including nuts, bolts and washers for building secufity light all as specified and directed |
| 17 | S & F in repairs 30 watts LED building security light fittings , pressure die cast aluminium housing powder coated graphite grey and toughened glass of IP 65 with pranuts including necessary fixing arrangements as per site requirements class all as specified and directed by Engr In charge.Make : Luker Cart Part No: LSTE030S or equivalent to Philips /Havells/ CG |
| 18 | S & F in repairs of LED flood light made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection of cap 80 Watt ,system efficacy >110/120 LPW, 220V 50Hz supply ,pressure Die cast aluminium housing and IP 66 Class I protection to be fixed on pole mounted iron frame or bracket including removing of the old unserviceable halogen/any type of light fittings all as specified and directed. Make: CG Cat No. TFS-504-80-30-60D-SL-GL-NSG or eqvuivalent to Philips / Havells |
| 19 | M&L for Sub main wiring complete with two runs (1P+1N) of 1.5 sq mm single core 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red /Yellow /Blue, Neutral- black and earth- green in and incl rigid PVC concealed/surface conduit (ISI marked) incl all specials/ accessories etc and provision of PVC insulated FRLSH copper conductor single core cable of same size but green in colour as continuous earthing wire all as directed. |
| 20 | Description same as per item Sl No 19 above but sub main wiring with 2 single core 4.0 sq mm duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire.Note (for item No 19 & 20) : 3 length of cable and one length casing & caping shall be measured and paid for one length . |
| 21 | S & F DB VTPN sheet metal enclosure double door suitable for incoming upto MCCB 100 Amps/125 Amps & outgoing MCB TP / SP (IP-43) Protection Triple pole and neutral 415 V 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete all as specified and directed. |
| 22 | S & F SPN DB sheet metal enclosure double door suitable (IP-43) Protection 12 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete. |
| 23 | S & F in replacement of MCCB, 3 pole, 100 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release alongwith copper separator terminalscomplete all as specified and as directed. |
| 24 | Supplying & fixing in repairs MCB SPN 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed . |
| 25 | Supplying & fixing in repairs MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed.Note for item No 23.00 to 25.00:- All copper conductors should be connected with MCCB/ MCB alongwith copper reducer terminals of suitable size duly crimpled.” |
| 26 | M&L for earthing complete in repairs with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I |
| 27 | Taking down Ceiling fan including ceiling rod , packing safely , sealing cable end, dismantling blades and removing fan and blades, deposite to E/M store complete all as specified and directed. |
| 28 | Supply and installation of 1200 mm sweep ceiling fan, suitable for operation on 230 V, 50 Hz, single-phase AC supply, complete with copper wound motor, powder-coated aerodynamic blades, down rod, shackle, canopy, remote control with battery, and all mounting accessories. The fan shall be BEE 5-Star rated, Class-B insulated, having rated power consumption of 28 W (±10%), rated speed of 350 RPM (±10%), minimum air delivery of 215 m³/min, power factor not less than 0.90, 3 blades, total harmonic distortion (THD) less than 10%, blade thickness not less than 1.2 mm, low-voltage starting up to 180 V, electronic surge protection up to 4 kV, and high-voltage protection capable of withstanding 1.5 kV, 50 Hz AC. The item shall also include 1.0 sqmm, 3-core copper flexible cable for connection, complete with all necessary mounting accessories, complete all as specified and directed by the Engineer-in-Charge. Make: Usha , Model No TECHNIX -BLDC ISI 5 STAR or equivalent to CG/ Havells/ Orient |
| 29 | Supply, installation, testing and commissioning of 450 mm sweep pedestal fan complete with copper wound motor, adjustable height stand, oscillating mechanism, 3-speed regulator, safety guard, all fixing accessories complete all as specified and as directed by Engr In charge.Make-Usha/ Havells/ CG/ Orient |
| 30 | S & F stepped type modular fan regulator, modular type complete all as specified and directed. Make : Roma (Anchor)/ Legrand/ Havells |
| 31 | M&L for Point wiring two single core 1.5 sqmm size PVC insulated, One light/fan point controlled by one switch 5 Amps one way unsheathed FRLSH multistranded copper conductor cable and one single core 1.5 sqmm size green colour PVC insulated FRLSH multistranded copper conductor cable as earth continuity conductor, 1100 volt grade (with proper colour coding Red/Blue/yellow for phase, black for neutral and green for earth) complete drawn through and including PVC casing and caping not less than 25 mm width with all fittings, surface on wall/roof /floor including including sunk pressed steel terminal boxes flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :-Note :- The unit rate quoted shall deemed to include the cost of following :-(a) GI metal flush box of minimum thickness of 1.6mm and modular cover plate with frame of any module complete.(b) Proper colour coding is to be followed as per IS specification.(c) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.(d) Cutting chases in wall/floor /beam/ceiling to be concealed conduit and making good the disturbed surfaces.Description same as per item Sl No 31 above but complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender