Tender For Repair / Maintenance Of Apfc Panel, Electrical Circuit Control Panel And Comprehensive Repair / Maintenance Of Power Pack, Ups And Allied Electrical Works At Various Installation At Nts Mahul, Thane, Nad (T) Area And Internal Electric Supp
Tender Overview
Project Description
Tender for Repair / Maintenance Of Apfc Panel, Electrical Circuit Control Panel And Comprehensive Repair / Maintenance Of Power Pack, Ups And Allied Electrical Works At Various Installation At Nts Mahul, Thane, Nad (T) Area And Internal Electric Supply, Bldg Security Light And Other Works At Bcf Sewri & Jerekene Factory Wadala Under Ge(Nw) Mankhurd.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 3 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 4 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge. |
| 5 | Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified. |
| 6 | Supply and laying in repairs cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete including taking down old us cable complete all as specified and directed. Make - Polycab/ KEI/ Havells |
| 7 | All as per SL Item No 6 herein before but of size 120 Sqmm 3.5 Core complete. Make - Polycab/ KEI/ Havells |
| 8 | All as per SL Item No 6 herein before but of size 70 Sqmm 3.5 Core complete. Make - Polycab/ KEI/ HavellsNote : For item Ser No.6,7 & 8 respectively :-(a) Excavation & Earth work shall be measured and paid seperately under appropriate item under this Schedule |
| 9 | Supply and fixing in repairs MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge. Make-ABB,Legrand,Schneider |
| 10 | Supply and fixing in repairs MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge. Make-ABB,Legrand,Schneider |
| 11 | Supply and fix in repair Cable jointing kit for 1.1 KV XLPE/ PVC cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/ 4 core armoured aluminium conductor cable of size 70 sqmm to 120 sqmm complete all as specified and directed.Make - 3M/ M-seal/ Raychem |
| 12 | -ditto- all as per above item no 11 but of size 150 sqmm to 185 sqmm complete all as specified and directed. Make - 3M/ M-seal/ Raychem |
| 13 | Supply and fix in replacement battery heavy duty 12 Volts 180 AH maintenance free complete all as specified and directed. Make : Exide/Amron/Cummins |
| 14 | Supply and fix in replacement battery heavy duty 12 Volts 130 AH maintenance free complete all as specified and directed. Make : Exide/Amron/Cummins |
| 15 | Supply and fix in repairs Power Capacitors of Rating 10 KVAR 415 Volt in repairs Naturally air cooled Double dielectric heavy duty, MPP type 440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR with meter system conforming to IS 13340 and 13341 ISI Marked all as specified. |
| 16 | All as per item No 18 above but Power Capacitors of Rating 5 KVAR 415 Volt complete all as specified and directed. |
| 17 | Supply and fix in repairs power factor controller relay 8 Stage RPM 8, 415 volts, 50 cycles suitable for manual / automatic operation with indication for each stage, power factor adjustment setting knob / screw, display. Make - L&T/ Conzerv / Neptune /SCHNIDER/SYNTRON/ |
| 18 | M & L for testing of APFC panel for proper functioning in manual & auto mode, re-wiring the burnt out wires, replacing the wiring ducts/casing Capping, fuse units and cleaning and testing complete all as directed by engineer-in-charge. |
| 19 | M & L in repairs for reinforced cement concrete nominal mix M-20 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed. (Note - Reinforcement and form work will be measured and paid separately). |
| 20 | M & L in repairs for TMT bars of Fe-500 D grade conforming to IS: 1786, 12 mm dia & over, including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed. |
| 21 | M & L in repairs for TMT bars of Fe-500 D grade conforming to IS: 1786, 8mm dia bars as in binders, spacers, strippus including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed. |
| 22 | M & L in repairs for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished surfaces of concrete, complete all as specified and directed. |
| 23 | Dismantling only in repairs of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed. |
| 24 | Supply, Fixing in reparis / replacement and connection of hot dip galvanised octagonal poles of height 8 mtr with 130mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 16mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed. Make: Bajaj |
| 25 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermalmanagement in multiple optics complete with IP 65/66 protection complete. |
| 26 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermalmanagement in multiple optics complete with IP 65/66 protection complete. |
| 27 | Supply and fixing in replacement from MCB SPN to RCBO earth leakage,overload and short circuit protection residual current circuit breaker with overcurrent protection DS201M-1P+N-30mA-16 Amps C Type AC complete all as specified and directed by engr-in-charge. |
| 28 | Supply and fixing in replacement from MCB SPN to RCBO earth leakage,overload and short circuit protection residual current circuit breaker with overcurrent protection DS201M-1P+N-30mA-32 Amps C Type AC complete all as specified and directed by engr-in-charge. |
| 29 | Supply & Fix in repair ACB 800 Amps, 4 Pole, 65 KA, with Thermal Magnetic Release (Manual Drawout type), over Load protection, Short Circuit Protection & earth Fault Protection, Metering Display including all necessary alteration required for fixing and testing complete all as specified and as directed. Make - Legrand/ L &T/ C&S/ Schneider/ ABB. |
| 30 | M&L for taking down old unsv and supply & lay 3 Core 1.5 Sq mm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit with necessary saddle, clamps, bolts & nuts, all for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc all as Directed. Make :- POLYCAB / KEI / HAVELLS/ BENLO |
| 31 | Supply install, testing and commissioning in renewal LT Power Distribution Board (CPRI Approved) indoor type Powder coated cubical type Indoor factory fabricated made out of 2 mm thick CRCA sheet & suitable for 3 Phase 4 wire 415 V, 50 Hz tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated in an approved factory having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust/ vermin proof & general construction confirming to IS : 8623/93 and size to accommodate all accessories/fittings, compartmentalized in construction to accommodate all accessories. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval not more than 500 mm through out the length of the TPN bus bar. |
| 32 | The Cubicle incomer MCCB as well as outgoing MCCBs shall have copper TPN extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coated sleeves. The cubicle shall have a bottom channel of size 50x50x6 mm duly coated with zinc metal coating having thickness not less than 100 microns. A detachable predrilled powder coated gland plate should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both sides having chromium plated 19mm dia fancy locks,louvers and air vent gasket for natural flow of air. The Panel shall be powder coated with pure polyster siemens grey structural RAL 7032 shade. The degree of protection of outer shell shall be IP-54. All control wires shall be with 2.5 sqmm multistrand copper conductors and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. A detachable predrilled gland plate of thickness 2.0 mm powder coated should be used at the bottom. Adhesive type gasket shall be used to make panel vermin proof/ Dustproof Complete as specified and consisting the following :- |
| 33 | i) Electrolytic Copper Busbar TPN 400 Amps -1 Set ii) On load Changeover swtich 250 Amp, 4 Pole, operating on 415 V, 50 Hz, AC supply complete -1 No Make - L&T/ Legrand/C&S/ Schneider/ ABB iii) MCCB 250 Amp, 3 Pole, 415V, 50 Hz Icu36 KA (Ics = 75%Icu), Thermal magnetic type - 01 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABBiv) MCCB 200 Amp, 3 Pole, 415V, 50 Hz Icu36 KA (Ics = 75%Icu), Thermal magnetic type - 01 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABBv) MCCB 100 Amp, 3 Pole, 415V, 50 Hz Icu25 KA (Ics = 75%Icu), Thermal magnetic type - 04 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABBvi) MCCB 63 Amp, 3 Pole, 415V, 50 Hz Icu16 KA (Ics = 75%Icu), Thermal magnetic type - 03 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABB vii) MCB 32 Amp, 3 Pole, 415V, 50 Hz Icu16 KA (Ics = 75%Icu) - 02 Nos (Street light) Make - L&T/ Legrand/C&S/ Schneider viii) MF Meter 4410 series -01 Noix) Indicating Lamps LED Type-03 Nosx) Street Light Time switch, 16 Amps & 2 Pole Contactor 40 Amp - 1 No Make - L&T/ C&S/ Schneider or equivalentNote –: The Lay out drawing of the panel shall be got approved by the contractor from GE before the panel fabrication work. Please Enable Macros to View BoQ information |
| 34 | i) Electrolytic Copper Busbar TPN 400 Amps -1 Set ii) On load Changeover swtich 250 Amp, 4 Pole, operating on 415 V, 50 Hz, AC supply complete -1 No Make - L&T/ Legrand/C&S/ Schneider/ ABB iii) MCCB 250 Amp, 3 Pole, 415V, 50 Hz Icu36 KA (Ics = 75%Icu), Thermal magnetic type - 01 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABBiv) MCCB 200 Amp, 3 Pole, 415V, 50 Hz Icu36 KA (Ics = 75%Icu), Thermal magnetic type - 01 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABBv) MCCB 100 Amp, 3 Pole, 415V, 50 Hz Icu25 KA (Ics = 75%Icu), Thermal magnetic type - 04 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABBvi) MCCB 63 Amp, 3 Pole, 415V, 50 Hz Icu16 KA (Ics = 75%Icu), Thermal magnetic type - 03 Nos (Outgoing) Make - L&T/ Legrand/C&S/ Schneider/ABB vii) MCB 32 Amp, 3 Pole, 415V, 50 Hz Icu16 KA (Ics = 75%Icu) - 02 Nos (Street light) Make - L&T/ Legrand/C&S/ Schneider viii) MF Meter 4410 series -01 Noix) Indicating Lamps LED Type-03 Nosx) Street Light Time switch, 16 Amps & 2 Pole Contactor 40 Amp - 1 No Make - L&T/ C&S/ Schneider or equivalentNote –: The Lay out drawing of the panel shall be got approved by the contractor from GE before the panel fabrication work. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender