Tender For Repair And Maintenance Of Dg Sets Different Capacity Including Connected Amf Panels And Other Connected Works At Def Lab Jodhpur
Tender Value
19.50 Lakhs
Estimated cost
Bid Submission
05 Sep 2026
4 days left
EMD
39000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Dg Sets Different Capacity Including Connected Amf Panels And Other Connected Works At Def Lab Jodhpur
BOQ
| Sl. No. | Item Description |
| 1 | Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity 40 KVA, dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform, removal of sludge from platform & also from inside of canopy of DG set including providing minor material like; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection, testing on full load complete to the entire satisfaction of the Engineer in Charge.Note : - (a) Replacement of spare parts shall be measured and paid as supply only under respective items given here in after.(b) DG Sets installed at site are of the Makes :- Kirlosker/cummins/Greave cotton /Crompton. |
| 2 | Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity 82.5 KVA, dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform, removal of sludge from platform & also from inside of canopy of DG set including providing minor material like; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection, testing on full load complete to the entire satisfaction of the Engineer in Charge.Note : - (a) Replacement of spare parts shall be measured and paid as supply only under respective items given here in after.(b) DG Sets installed at site are of the Makes :- Kirlosker/cummins/Greave cotton /Crompton. |
| 3 | Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity 125 KVA & upto 200 KVA, dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform, removal of sludge from platform & also from inside of canopy of DG set including providing minor material like; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection, testing on full load complete to the entire satisfaction of the Engineer in Charge.Note : - (a) Replacement of spare parts shall be measured and paid as supply only under respective items given here in after.(b) DG Sets installed at site are of the Makes :- Kirlosker/cummins/Greave cotton /Crompton. |
| 4 | Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity 250 KVA & upto 320 KVA, dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform, removal of sludge from platform & also from inside of canopy of DG set including providing minor material like; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection, testing on full load complete to the entire satisfaction of the Engineer in Charge.Note : - (a) Replacement of spare parts shall be measured and paid as supply only under respective items given here in after.(b) DG Sets installed at site are of the Makes :- Kirlosker/cummins/Greave cotton /Crompton/jackson. |
| 5 | Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity 750 KVA, dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform, removal of sludge from platform & also from inside of canopy of DG set including providing minor material like; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection, testing on full load complete to the entire satisfaction of the Engineer in Charge.Note : - (a) Replacement of spare parts shall be measured and paid as supply only under respective items given here in after.(b) DG Sets installed at site are of the Makes :- Kirlosker |
| 6 | Supply only diesel filter suitable for DG set of capacity 40 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 7 | Supply only diesel filter suitable for DG set of capacity 82.5 KVA .Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 8 | Supply only diesel filter suitable for DG set of capacity 125 KVA & and upto 200 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 9 | Supply only diesel filter suitable for DG set of capacity 250 KVA and upto 320 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 10 | Supply only Diesel filter suitable for 750 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 11 | Supply only Engine oil filter suitable for DG set of capacity 40 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 12 | Supply only Engine oil filter suitable for DG set of capacity 82.5 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 13 | Supply only Engine oil filter suitable for DG set of capacity 125 KVA and upto 200 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 14 | Supply only Engine oil filter suitable for DG set of capacity 250 KVA and upto 320 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 15 | Supply only Engine oil filter suitable for 750 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 16 | Supply only water separator filter suitable for DG set of capacity 82.5 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 17 | Supply only water separator filter suitable for DG set of capacity 125 KVA and upto 200 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 18 | Supply only water separator filter suitable for DG set of capacity 250 KVA and upto 320 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 19 | Supply only water separator filter suitable for 750 KVA.Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves. |
| 20 | S&F in replacement of Air Cleaner Element (inner & outer) suitable for following capacity of DG Set. Air cleaner will be changed after every 500 hrs or when reqd complete all as specified and directed.Make MICO/Sakura/ Fleetguard |
| 21 | 750 KVA DG Set Make : Kirloskar |
| 22 | 320 KVA DG Set Make : Kirloskar and Green) |
| 23 | 250 KVA DG Set make : Crompton Greaves |
| 24 | 200 KVA DG Set Make : cummins |
| 25 | 125 KVA DG set Make : Kirloskar Green & Cummins |
| 26 | 82.5 KVA DG set Make :Cummins |
| 27 | 40 KVA DG set Make : Kirloskar |
| 28 | M&L for dismantling the radiator and fan from the engine of capacity 40 KVA for cleaning of copper tubes and cooling fins by using descaling solution and soldering, patch work including minor repair and re-assembliying,testing complete of any capacity DG set complete all as specified and directed by Engineer in charge. |
| 29 | M&L for dismantling the radiator and fan from the engine of capacity 82.5 KVA & upto 125 KVA for cleaning of copper tubes and cooling fins by using descaling solution and soldering, patch work including repair of water pump assembly and replacement of defective parts of water pump and re-assembliying,testing complete of any capacity DG set complete all as specified and directed by Engineer in charge. |
| 30 | M&L for dismantling the radiator and fan from the engine of capacity 200 KVA for cleaning of copper tubes and cooling fins by using descaling solution and soldering, patch work including repair of water pump assembly and replacement of defective parts of water pump and re-assembliying,testing complete of any capacity DG set complete all as specified and directed by Engineer in charge. |
| 31 | Material and Labour for dismantling the radiator and fan from the engine of DG set of capacity 250 KVA & upto 320 KVA for cleaning of copper tubes and cooling fins by using descaling solution and soldering, patch work, repairing for smooth funtioning including necessary transporting for repair to workshop, bringing back including successful re-installation complete all as specified and directed. |
| 32 | Material and Labour for dismantling the radiator and fan from the engine of DG set of capacity 750 KVA for cleaning of copper tubes and cooling fins by using descaling solution and soldering, patch work, repairing for smooth funtioning including necessary transporting for repair to workshop, bringing back including successful re-installation complete all as specified and directed. |
| 33 | M&L servicing/ cleaning of MS diesel tank of any capacity DG Set by draining out the diesel from tank, cleaning the tank with soap water/ suitable solution and painting the external surface with one coat of synthetic enamel paint of existing colour including replacement of drain valve, outlet pipe complete all as specified and as directed. |
| 34 | Labour only for repair, maintenance and overhauling of the canopy type DG Set of capacity 250 KVA & upto 320 KVA 415 Volt 50 Hz of Make - greaves /Jackson/Kirloskar including repair of engine head with accessories and repair to inlet, outlet valve and all machinery work including electrical connections and testing complete up to the entire satisfaction of Engineer-in-Charge.Note : Materials required will be measured and paid separately under respective items. |
| 35 | Supply only in replacement of Piston ring of suitable size of original make as existing in the canopy type DG set of capacity 250 KVA upto 320 KVA 415 Volt 50 Hz complete all as specified and directed. |
| 36 | Supply only in replacement of Engine gasket, O ring of suitable size of original make as existing in the canopy type DG Set of capacity 250 KVA & upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 37 | Supply only in replacement of Packing kit of suitable size of original make as existing in the canopy type DG Set of capacity 250 KVA & upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 38 | Supply only in replacement of main seal of suitable size of original make as existing in the canopy type DG Set of capacity 250 KVA & upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 39 | Supply only in replacement of for valve of canopy type DG Set of capacity 250 KVA & upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 40 | Supply only in replacement of valve guide of canopy type DG Set of capacity 250 KVA upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 41 | Supply only in replacement of Hose pipe kit of canopy type DG Set of capacity 250 KVA & upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 42 | Material and labour for head work of canopy type DG Set of capacity 250 KVA & upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 43 | Supply only in replacement of filter kit suitable for canopy type DG Set of capacity 250 KVA & upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 44 | Supply only in replacement of Fan Belt suitable for canopy type DG Set of capacity 250 KVA upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 45 | Material and Labour for radiator cleaning of canopy type DG Set of capacity 250 KVA & upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 46 | Supply only in replacement of water body assembly suitable for canopy type DG Set of capacity 250 KVA upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 47 | M&L for nozzle fuel pipe setting of the canopy type DG Set of capacity 250 KVA upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 48 | M&L for nozzle caliberation of the canopy type DG Set of capacity 250 KVA upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 49 | M&L for fuel pump caliberation of the canopy type DG Set of capacity 250 KVA upto 320 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 50 | Labour only for repair, maintenance and overhauling of the canopy type DG Set of capacity upto 200 KVA 415 Volt 50 Hz of Make - cummins /Kirloskar including repair of engine head with accessories and repair to inlet, outlet valve and all machinery work including electrical connections and testing complete up to the entire satisfaction of Engineer-in-Charge.Note : Materials required will be measured and paid separately under respective items. |
| 51 | Supply only in replacement of Piston ring of suitable size of original make as existing in the canopy type DG set of capacity upto 200 KVA 415 Volt 50 Hz complete all as specified and directed. |
| 52 | Supply only in replacement of Engine gasket, O ring of suitable size of original make as existing in the canopy type DG Set of capacity upto 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 53 | Supply only in replacement of Packing kit of suitable size of original make as existing in the canopy type DG Set of capacity upto 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 54 | Supply only in replacement of main seal of suitable size of original make as existing in the canopy type DG Set of capacity 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 55 | Supply only in replacement of for valve of canopy type DG Set of capacity upto 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 56 | Supply only in replacement of valve guide of canopy type DG Set of capacity upto 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 57 | Supply only in replacement of Hose pipe kit of canopy type DG Set of capacity upto 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 58 | Material and labour for head work of canopy type DG Set of capacity upto 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 59 | Supply only in replacement of filter kit suitable for canopy type DG Set of capacity upto 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 60 | Supply only in replacement of Fan Belt suitable for canopy type DG Set of capacity upto 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 61 | Material and Labour for radiator cleaning of canopy type DG Set of capacity upto 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 62 | Supply only in replacement of water Pump assembly suitable for canopy type DG Set of capacity upto 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 63 | M&L for nozzle fuel pipe setting of the canopy type DG Set of capacity 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 64 | M&L for nozzle caliberation of the canopy type DG Set of capacity upto 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 65 | M&L for fuel pump caliberation of the canopy type DG Set of capacity upto 200 KVA 415 Volts, 50 Hz complete all as specified and directed. |
| 66 | S&F in repair of AVR for DG set having capacity 40 KVA.Make :-kirloskar,cummins,Jackson,CG all as directed by Engr-in-Charge. |
| 67 | S&F in repair of AVR for DG set having capacity 82.5 KVA upto 125 KVAMake :- kirloskar,cummins,Jackson,CG all as directed by Engr-in-Charge. |
| 68 | S&F in replacement of AVR for DG set having capacity 200 KVA & upto 320 KVAMake :- -kirloskar,cummins,Jackson,CG all as directed by Engr-in-Charge |
| 69 | S&F in replacement of AVR for DG set having capacity 750 KVAMake :- -kirloskar,cummins,Jackson,CG all as directed by Engr-in-Charge |
| 70 | S&F over and under voltage relay for AMF panel of any capacity of DG Sets complete all as specified & directed by Engineer-in-Charge. |
| 71 | S&F VMR (voltage Monitoring relay) for AMF panel of any capacity of DG Sets complete all as specified & directed by Engineer-in-Charge. |
| 72 | M&L for servicing/repair of self starter of any capacity 40 KVA incl replacement of parts such as carbon brushes, solonoid, rotor,washer, nut, bolts etc assembling the same and testing complete all as specified and directed by Engineer in charge. . |
| 73 | M&L for servicing/repair of self starter of capacity 82.5 KVA & upto 125 KVA DG set incl replacement of parts such as carbon brushes, solonoid, rotor,washer, nut, bolts etc assembling the same and testing complete all as specified and directed by Engineer in charge. . |
| 74 | M&L for servicing/repair of self starter of capacity 200 KVA & upto 320 KVA DG set incl replacement of parts such as carbon brushes, solonoid, rotor,washer, nut, bolts etc assembling the same and testing complete all as specified and directed by Engineer in charge. . Please Enable Macros to View BoQ information |
| 75 | M&L for servicing/repair of self starter of capacity 200 KVA & upto 320 KVA DG set incl replacement of parts such as carbon brushes, solonoid, rotor,washer, nut, bolts etc assembling the same and testing complete all as specified and directed by Engineer in charge. . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender