Tender For Repairs / Maintenance Of Defective W/S Pumping Line To Various Static Tanks At Nad, Wed, Nsd Sewri And Other Maintenance Works In The Aor Of Age E/M Under Ge (Nw) Mankhurd.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Sep 2026
11 days left
EMD
90500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs / Maintenance Of Defective W/S Pumping Line To Various Static Tanks At Nad, Wed, Nsd Sewri And Other Maintenance Works In The Aor Of Age E/M Under Ge (Nw) Mankhurd.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and not exceeding 10 sqm on plan and getting out in soft/loose soil for laying of cables, etc. complete all as specified and as directed. |
| 2 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm deep as in hard/soft soil complete all as specified and as directed. |
| 3 | Removing excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point in soil including spreading in low lying area and leveling complete all as specified and as directed. |
| 4 | M&L for cutting existing road/hard standing not exceeding 45x50 cm in wide & depth getting out excavated material for laying GI tube, returning filling & well rammaing watering finish suraface 10 cm from top including provision of PCC 1:3:6 for repairing, including removal of surplus soil all as directed. |
| 5 | M & L for PCC 1:3:6 in round/ square shape as per site requirement of thickness not less than 3\\" suitable for fixing of cast iron tank cover complete all as specified and directed. |
| 6 | M&L for taking down existing 20 mm bore steel conduit tubing complete with all fittings, accessories and connections, including disconnecting from the existing system, removing from site, for Schedule of Credit, and making good disturbed surfaces as required to facilitate installation of new pipe line, complete all as specified and as directed. |
| 7 | Ditto all as per item No 6 above but 25 mm dia bore complete |
| 8 | Ditto all as per item No 6 above but 40 mm dia bore complete |
| 9 | Ditto all as per item No 6 above but 50 mm dia bore complete |
| 10 | Ditto all as per item No 6 above but 80 mm dia bore complete |
| 11 | Ditto all as per item No 6 above but 100 mm dia bore complete |
| 12 | Supply & Laying fixing, connecting and testing steel water tubing, medium grade, galvanised, with screwed and socketed joints, in any length, including supply and fixing all fittings, fixed to walls or laid in trenches / floors etc complete all as specified and as directed for the 20 mm bore, ISI marked. Make-: Tata/ Jindal/ BST/ Oswal |
| 13 | Ditto all as per item No 12 above but 25 mm dia bore complete |
| 14 | Ditto all as per item No 12 above but 40 mm dia bore complete |
| 15 | Ditto all as per item No 12 above but 50 mm dia bore complete |
| 16 | Ditto all as per item No 12 above but 80 mm dia bore complete |
| 17 | Ditto all as per item No 12 above but 100 mm dia bore complete |
| 18 | Supply and fix ISI Marked UPVC Pipe size 50 mm nominal dia,pressure pipe Schedule 80 with all connected acessories like UPVC bend,Tees,Unions,Sockets etc for each 3 mtr length of Pipe & solvent to join it all as specified and as directed.Make:Supreme/Dutron/Finolex/Duplon |
| 19 | Ditto all as per item No 18 above but 40 mm dia bore complete |
| 20 | Ditto all as per item No 18 above but 25 mm dia bore complete |
| 21 | Supply, lay/fix, connect and testing DI water tubing of 80 mm bore with spigot and socket ends class K-9 conforming to IS:8329/2000 suitable for rubber tyton joint including taking out old damaged CI main with fitting burning out joints and recovering lead complete etc as specified and directed. |
| 22 | Ditto all as per item No 21 above but 100mm dia bore complete |
| 23 | Ditto all as per item No 21 above but 150mm dia bore complete |
| 24 | Ditto all as per item No 21 above but 200mm dia bore complete |
| 25 | M & L for DI fittings class K-12 conforming to IS:9523/2000 upto 200 mm dia of any type, size, such as bend, tapper, tail piece, tee piece, cross etc complete all as specified and directed. |
| 26 | S&F in repairs gunmetal gate or globe valve for 65 mm dia, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed. Make :- Kirloskar, Upadhaya , Leader, Zoloto. |
| 27 | Ditto all as per item No 26 above but 50 mm dia bore complete. Make :- Kirloskar, Upadhaya , Leader, Zoloto. |
| 28 | Ditto all as per item No 26 above but 40 mm dia bore complete. Make :- Kirloskar, Upadhaya , Leader, Zoloto. |
| 29 | Ditto all as per item No 26 above but 25 mm dia bore complete. Make :- Kirloskar, Upadhaya , Leader, Zoloto. |
| 30 | Ditto all as per item No 26 above but 20 mm dia bore complete. Make :- Kirloskar, Upadhaya , Leader, Zoloto. |
| 31 | Taking out sluice valves of size 80 mm to 100 mm and transporting to workshop for lathe work by refacing, regrinding, metalling and refixing back at site to match with standard size and refixing in position including replacing of worn out gland packing/washers /nuts/ bolts etc for the following size sluice valves.Note : Rate quoted is inclusive of cost of spare parts. |
| 32 | Ditto all as per item No 31 above but for size 150 mm to 200 mm dia bore complete. |
| 33 | S&F sluice valve 80 mm bore, cast iron body, flanged and drilled end, conforming to IS-14846, ISI marked, Class PN 1.6 including all joints with rubber or fibre board, gaskets, bolts and nuts, washers, iron wheel including taking up / down old unserviceable valves from any position and any addition / alteration for fixing required complete all as specified and as directed. Make-: Kartar/ Kirloskar/ Upadhyay |
| 34 | Ditto all as per item No 33 above but 100 mm dia bore complete. Make-: Kartar/ Kirloskar/ Upadhyay |
| 35 | Ditto all as per item No 33 above but 150 mm dia bore complete. Make-: Kartar/ Kirloskar/ Upadhyay |
| 36 | M&L for run lead joints to CI spigot and socket pipes of 80 mm bore and fittings including cleaning the joints, re-aligning the pipeline properly as required, cocking and jointing with old pig lead, including any addition / alteration for fixing required, testing pipelines for any leakage, making good any disturbed / damaged pipeline / parts etc, complete all as specified and as directed Note-: Necessary excavation and earthwork will be measured and paid separately |
| 37 | Ditto all as per item No 36 above but 100 mm dia bore complete |
| 38 | Ditto all as per item No 36 above but 150 mm dia bore complete |
| 39 | Supply and fix in replacement ladder height 10 feet max, steps on every 01 feet made of angle iron of size 50x65x5 mm thick for sump including taking down old rusted iron ladder complete all as specified and directed. |
| 40 | Dismantling existing PVC water storage tanks and Supplying, hoisting and fixing rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) of 500 Litres capacity with and including covers, hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes etc complete all as specified and as directed Make-: Sintex/ Reno/ Plasto |
| 41 | Ditto all as per item No.40 above but 1000 litres capacity |
| 42 | Ditto all as per item No.40 above but 2000 litres capacity |
| 43 | Ditto all as per item No.40 above but 3000 litres capacity |
| 44 | M&L for supply and fixing in repair 50 mm bore PTMT Ball Valve, high pressure type, ISI marked, with epoxy-coated aluminium operating handle and high-density plastic ball, suitable for screwed connection to GI/iron pipe, including dismantling of existing unserviceable valve (if any), making threaded joints with PTFE tape, fixing, jointing, testing for leak-proof operation, and making good disturbed surfaces, complete all as specified and as directed.Make: Prayag / Shakti. |
| 45 | Ditto all as per item No.44 above but 40mm dia bore complete. Make -: Prayag/Shakti |
| 46 | Ditto all as per item No.44 above but 25mm dia bore complete. Make -: Prayag/Shakti |
| 47 | Ditto all as per item No.44 above but 20mm dia bore complete. Make -: Prayag/Shakti |
| 48 | M&L for draining out water, thoroughly cleaning and removing accumulated sludge, dirt, and scale from the bottom, walls, ceiling, and mouths of circulating pipes of service tanks/PVC tanks of capacity not exceeding 500 litres located on the rooftops of buildings. The work includes disinfection of tanks using bleaching powder to ensure they are bacteria-free, removal of all previously written dates from the tank surface, and depositing the removed waste in low-lying areas of defence land as directed. After cleaning, the date of cleaning shall be stenciled in white synthetic enamel paint on a black background, in 100 mm high letters, in the format: \\"CLEANED ON (DATE) DUE ON (DATE)\\", complete all as specified and as directed. |
| 49 | Ditto all as per item No 48 above but capacity of tank exceeding 500 Ltrs and upto 1000 Ltrs |
| 50 | Ditto all as per item No 48 above but capacity of tank exceeding 1000 Ltrs and upto 2000 Ltrs |
| 51 | Ditto all as per item No 48above but capacity of tank exceeding 2000 Ltrs and upto 3000 Ltrs |
| 52 | Ditto all as per item No 48 above but capacity of tank exceeding 3000 Ltrs and upto 5000 Ltrs |
| 53 | M&L for fabricating, supplying and fixing valve chamber covers made of suitable size MS angle, MS plate, MS flat and MS rod, complete with hinges, locking arrangement and all necessary welding, cutting, drilling and fitting work, including removing the existing unserviceable rusted cover, applying one coat of red oxide zinc chromate primer followed by two coats of synthetic enamel paint of approved shade, and fixing the cover in position complete, all as specified and as directed by the Engineer-in-Charge. |
| 54 | Taking out old/ unsv cast iron/ MS tank cover from RCC tank including dismatlling of RCC base support/ MS or cast iron frame and supplying & fixing cast iron tank cover in round shape of size 21 inches internal dia, with proper anchor in PCC with nut, bolts, anchor fastner etc with locking arrangement etc complete with two coats of black bituminous paint (drinking grade) for 1000 ltr/ 2000 ltr/ 3000 ltr all as specified and as directed Note-: Plastering and PCC work shall measured and paid seperately |
| 55 | Dismantling of existing PVC water storage tank covers and Supplying and fixing PVC tank cover round shape of suitable size as per ground requirement with locking arrangement and fixed in position etc complete all as specified and as directed |
| 56 | Supplying, fixing, jointing and testing non-return valve suitable for GI tubing of size 80 mm bore size, (ISI Marked) both ends flanged and drilled for jointing including two flange joints and jointing material such as nuts, bolts washers rubber packing etc including taking down complete all as specified and as directed. Make :- Kirloskar, Upadhaya , Leader, Zoloto. |
| 57 | Ditto all as per item No. 56 above but 50 mm dia bore complete all as specified & directed. |
| 58 | Supplying, fixing, jointing and testing non-return valve (Forged brass swing type check valve) suitable for GI tubing of size 40 mm bore complete all as specified & directed. Make :- Leader, Zoloto |
| 59 | Supplying, fixing, jointing and testing non-return valve (Forged brass swing type check valve) suitable for GI tubing of size 25 mm bore complete all as specified & directed. Make :- Leader, Zoloto |
| 60 | S & F foot valve of size 65 mm dia cast iron body, ball type, with flanged and drilled ends and synthetic rubber coated MS ball, conformimg to relevant IS, ISI marked, including all joints, gaskets, bolts and nuts, washers, including taking up/down old unserviceable valves from any position and any addition/alteration for fixing required complete all as specified and directed by the engineer in charge. Make : Kirloskar or equivalant or as approved by GE. |
| 61 | M&L for renewal of valve pit of size up to 80 cm x 80 cm x 80 cm (internal diamension), stone / brick construction including all necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, PCC in foundation for mix (1:2:4) type D2 brick mansonary in cement mortar (1:4) rendering 12 mm duck in cement mortar (1:4) internally , finished even and fair and polishing flush externally as the work proceeds in the same mortor. Mild steel angle iron 40 x 40 x 6 mm frame MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all exposed MS work with two coats of synthetic enamel paint of the that as approved by the Engineer - in - charge over a coat of red oxide primer and painting all the MS embeded in PCC with two coats of black bitumenous paint complete all as specified. |
| 62 | Supply only Calcium hypo chlorite 65% -70% chlorine content granular based water disinfectent in sealed containers complete all as specified and as directed.Make:- 1.Aqufit manufactured by Sree Rayalaseema Hi strength Hypo Ltd. 2. Puri chlor manufactured by Sree Rayalaseema Hi strength Hypo Ltd. / M/s Ravi Enterprises / M/s Potter & Watts (Traditional products). Brands having pan india availability, acceptability & being manufactured /processed in open market termed as traditional products .The brands /makes must have certified by All India Institute of Hygenic & Public Health. 3. Best available in the market |
| 63 | Supply only Bleaching powder grade -I ISI marked having stable available chlorine % by mass minimum 35% as per IS 1065,1971 and packed in 25 Kg bag complete all as specified and directed. Make : Vikram / DCM Shriram / Grasim / GACL |
| 64 | M&L for lifting out the existing 5 HP submersible pump set from bore well, including disconnecting and dismantling the delivery column pipe with all flanged/socket joints, taking down the pump set to workshop, carrying out complete repairs including rewinding of motor with super enamelled copper winding wire, replacement of bearings, bushes, mechanical seal, insulation materials, gaskets, fasteners and other defective components as required, reassembling the pump set, lowering and refixing the repaired pump set in the bore well, reconnecting and tightening all flanged/socket joints of the delivery pipe, refixing the existing safety clamp with steel wire rope, reconnecting the submersible cable, testing, commissioning and making the pump set fully operational and serviceable, complete all as specified and as directed. |
| 65 | S&F in repairs chlorine testing KIT with colored sample complete with all testing fitment and OT solution in rexine finish box.Make :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro |
| 66 | S&F in repairs chloroscope (Chlorine & PH test kit) for estimation of residual chlorine in water comprises of Plastic box, two tube, Droper and colour filter for colour estimation.Make :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro |
| 67 | S&F in repairs Water Quality TDS tester with ATC, Digital and Pocket type, Range : TDS 0-999 PPM(Mg/L) Model No :- ATDS0016. Make :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro |
| 68 | M&L for complete rewinding and overhauling of 25 HP, 3-phase, 50 Hz, 415V electric motor, including disconnecting and dismantling existing burnt winding, rewinding with super-enameled copper wire of appropriate gauge using standard insulation materials (PVC sheets, cotton tape, sleeves, varnish, etc.), transportation of motor to and from workshop including loading/unloading, replacement of 2 Nos. ball bearings (make: SKF/NBC/TATA), renewal of terminal plate with brass studs, nuts, bolts, and washers, reinstallation at site with proper alignment, connection, and load testing, along with dismantling, cleaning, and overhauling of the coupled centrifugal/monoblock pump including replacement of defective components such as impellers, bushes, thrust bearings, clutch system, bowl assembly, pump shaft, and other unserviceable parts as required, followed by reassembly, alignment, commissioning, and on-load testing to ensure full operational efficiency, complete all as specified and directed. |
| 69 | All as per Item No 68 For Motor 15 HP Cap |
| 70 | All as per Item No 68 For Motor 10 HP Cap |
| 71 | All as per item No 68 for Motor 7.5/5 HP cap |
| 72 | M & L for preparation of existing painted steel pipes, including fire main lines, fire hydrant stand posts, and all exposed GI pipes, by removing the deteriorated paint layer through manual or mechanical scraping using wire brushes, scrapers, or sandpaper. The surface shall be thoroughly cleaned to remove dust, grease, rust, or any contaminants, ensuring an even, bare metal or sound substrate ready for painting and apply one coat of synthetic enamel paint, ensuring uniformity in thickness and adherence as per manufacturer specifications shall comply with IS standards, apply a compatible metal primer on bare metal sections before enamel application to enhance corrosion resistance and paint adhesion complete as per specifications and as directed by the engineer-in-charge. . Make :- Asian, Berger, Apex, or Nerolac Please Enable Macros to View BoQ information |
| 73 | M & L for preparation of existing painted steel pipes, including fire main lines, fire hydrant stand posts, and all exposed GI pipes, by removing the deteriorated paint layer through manual or mechanical scraping using wire brushes, scrapers, or sandpaper. The surface shall be thoroughly cleaned to remove dust, grease, rust, or any contaminants, ensuring an even, bare metal or sound substrate ready for painting and apply one coat of synthetic enamel paint, ensuring uniformity in thickness and adherence as per manufacturer specifications shall comply with IS standards, apply a compatible metal primer on bare metal sections before enamel application to enhance corrosion resistance and paint adhesion complete as per specifications and as directed by the engineer-in-charge. . Make :- Asian, Berger, Apex, or Nerolac Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysSep 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender