Tender For Aluminium Partition For Creche In Service Block In Judicial Court Complex, Gurdaspur Under Head 4059 14Th Fc In Distt Gurdaspur
Tender Value
6.20 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
6 days left
EMD
13000
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurdaspur → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Aluminium Partition For Creche In Service Block In Judicial Court Complex, Gurdaspur Under Head 4059 14Th Fc In Distt Gurdaspur
BOQ
| Sl. No. | Item Description |
| 1 | Scraping of White Washing |
| 2 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 3 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 4 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) : |
| 5 | For fixed portion and chawkhats |
| 6 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug /neoprene gasket required |
| 7 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side. |
| 8 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt |
| 9 | Dismantling of Brick work Tiles,masonary or tile lining |
| 10 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 11 | 12.5mm thick cement plaster 1:5. |
| 12 | Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete |
| 13 | Doors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter. |
| 14 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing thesame in position 30mm thick |
| 15 | Public Health |
| 16 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. |
| 17 | Inside size 90x150 cm and 120 cm deep |
| 18 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design |
| 19 | Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal |
| 20 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.160mm o/d pipe |
| 21 | Excavation manually in trenches with straight or open cutting in built up street/ lane having wall to wall width of street/ lane upto 3.0 metre, for intramural sullage drains, extramural intercepting drains and outfall drains, storm water channels and other work contingent or incident thereto, to full dimensions and depth as shown on the drawings or as shall be required by Engineer in-charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic. Providing and fixing and maintenance of caution boards, fencing, night signals, for leads upto 15m and for all lifts and subsequent refilling, watering and dressing upto groung level, including removal of surplus spoil from the site upto 15 metre distance complete in all respects. All classes of soil except rocky |
| 22 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:2 (1 cement : 2 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. For pipes 100 to 250 mm Diametre |
| 23 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A |
| 24 | 90mm o/d single socket SWR UPVC pipe lines laid complete |
| 25 | Disilting of manhole including all safety measures, cost of container T & P and disposal of silt upto 5km complete in all respects. Depth upto 3 m. |
| 26 | Sub Head-2 Internal Water Supply System |
| 27 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 28 | CPVC SDR 11 Pipe & fitting 20mm o/d |
| 29 | CPVC SDR 11 Pipe & fitting 32mm o/d |
| 30 | CPVC SDR 11 Pipe & fitting 40mm o/d |
| 31 | Cutting chase in brick walls in cement or in floor for embedding CPVC pipes lines and making good the same to its original condition. Size 75mm x 75mm |
| 32 | Providing, fixing and jointing G.I Union Couplings (of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. 32mm i/d G.I. Union |
| 33 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Make vectus Triple Layer Tanks 1000ltr Capacity 1x1000ltr = 1000ltr |
| 34 | Sub Head - 3 Sanitary Installation |
| 35 | Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 36 | Chinaware Floor Mounted One Piece EWC rim less type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) size 69x36x74 cm with P trap or S trap and seat cover complete in all respect. |
| 37 | Providing and fixing jet spray with 2'-6\\" long PVC pipe.With PTMT nut |
| 38 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Size 630 mm x 450 mm x 830 mm |
| 39 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. |
| 40 | Vitreous chinaware standard white pedestal for wash hand basin. |
| 41 | Cutting holes upto 23cm square thorugh B.B. in cement walls or stone masonary wall in cement for pipes, and making goo/d including repointing, replastering and finishing according to existing finish where required. |
| 42 | Through wall 22.86 cm thick |
| 43 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 44 | PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut |
| 45 | Providing and fixing PVC waste pipe 32mm complete in all respect. |
| 46 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 47 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 48 | C.P. brass Bib cock long nose/ long body foam flow without flange |
| 49 | C.P. brass Bib cock without flange |
| 50 | P/F of FTA Brass 20mmx20mm |
| 51 | P/F of MTA Brass 20mmx20mm |
| 52 | P/F Float Valve Make Supreme |
| 53 | P/F Upper Body of Wall Concealed |
| 54 | P/F CPVC Ball Valve 20mm |
| 55 | P/F CP Waste Floor Jali 4\\" of approved make (Cockroach Preventing) |
| 56 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. A C.P. Brass fittings: |
| 57 | C.P. brass 3-Hole Basin Mixer Without Popup Waste System |
| 58 | Providing & Fixing in postion stop cock / Angle valve (as approved by the Engineer-in-charge). |
| 59 | C.P.brass 15mm concealed stop cock with flange |
| 60 | Providing and fixing in postion storage type automatic electric water heater pressure / non pressure type thermostatically controlled, single phase, vertical wall mounted of approved make (to the approval of Engineer-in charge) with thermostats, inner container of stainless steel complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect.25 litre capacity water heater |
| 61 | Providing & Fixing in position C.P. Brass flange of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 62 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 50mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. |
| 63 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)a) Size 600mmx450mm |
| 64 | Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect.Vitreous Chinaware white toilet paper holder |
| 65 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.(B) C.P brass towel ring |
| 66 | Providing and fixing in position 15mm C.P. Pillar cock foam flow of approved make (to the approval of Engineer-in-charge) |
| 67 | Sub Head- 4 Air Conditioners & RO |
| 68 | AIR CONDITIONERProviding and Installing of Split Type Air Conditioning Unit with latest inverter Technology of 2.0 TR Capacity, 5 star Rating for 230 Volts single phase supply with nature friendly refrigerant R32 gas including 3mtr copper insulation pipe, which is capable of performing the following functions:- (i) Cooling (ii) Dehumidifying (iii) Air Circulation (iv) Filtering including installation charges. As desired by the Engineer-in-charges Complete in all Respect. As per Analysis AttachedMake:- Daikin, Blue Star, Voltas, Carrier, Hitachi or equivalent make |
| 69 | OUTDOOR UNIT STANDProviding and Fixing Heavy Duty Mild Steel Outdoor unit stand for Air Conditioning Outdoor unit. (Powder Coated) complete in all respect as desired by the Engineer-in-charge:- |
| 70 | COPPER PIPESupplying & Installation of heavy duty hard soft copper refrigrant piping from indoor to outdoor unit including all required fitting, as desired by the Engineer-in-charges Complete in all Respect. As per Analysis Attached |
| 71 | AUTOMATIC VOLTAGE STABLIZERSupply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- as desired by the Engineer-in-charges Complete in all Respect. |
| 72 | Automatic Voltage Stablizer 5 KVA for 2.0 TR Capacity Air Conditioners |
| 73 | MCB ARRANGEMENTSSupply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- as desired by the Engineer-in-charges Complete in all Respect. |
| 74 | MCB Double Pole 6-32amp. (10kA, Curve- C) |
| 75 | PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE: |
| 76 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 77 | Overall size 4.0sq.mm (84/0.3mm), 3Core |
| 78 | CASING & CAPPINGSupply & erection of Best Quailty HD PVC Casing 'n' Capping (Double Lock) Batten type ISI marked for covering the copper pipe, drain pipe & wiring arrangements including cost of bends (L), (U), (T) & inspection boxes etc., where necessary including other petty material complete in all respects, as desired by the Engineer-in-charge:- |
| 79 | PVC Casing 'n' Capping Size 50mm x 16mm |
| 80 | CUTTING HOLES IN WALLCutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required complete in all respects, as desired by the Engineer-in-charge:- |
| 81 | Through wall 22.86 cm thick |
| 82 | UPVC PIPELINEProviding and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. uPVC Pipe 10 Kgf/cm2 |
| 83 | 25mm i/d Vertical Drain pipe |
| 84 | 40mm i/d Horizontal Drain pipe |
| 85 | UV FILTERProviding & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.Make... EUREKA FORBES/ Kent / Aquasure – or its equivalent. |
| 86 | Sub Head- 5 Flooring & Wall Tiles |
| 87 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of material) |
| 88 | Cement concrete 1:2:4 With stone ballast or shingle mixing by manual means |
| 89 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 90 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete |
| 91 | Sub Head- 6 Fire Fighting Arrangements |
| 92 | Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (storedpressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 4 Kg. Capacity |
| 93 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 94 | Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 95 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 96 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 97 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 98 | Overall size 1.5sq.mm (Un-sheathed) |
| 99 | Overall size 4sq.mm (Un-sheathed) |
| 100 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 101 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 102 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 103 | CAPACITORS & BALL BEARINGS: |
| 104 | Supply and erection of Capacitors of different capacity for ceiling fans, exhaust fan & street light fittings etc.:- |
| 105 | Capacitor 2.5µF |
| 106 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: |
| 107 | MINIATURE CIRCUIT BREAKERS: |
| 108 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 109 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 110 | MCB Double Pole 50, 63amp. (10kA, Curve-C) |
| 111 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: |
| 112 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 113 | SP&N Double Door Distribution Board 4 way each |
| 114 | REPAIR AND REWINDING OF CEILING/ EXHAUST FANS: |
| 115 | Providing Full stator rewinding of a Ceiling fan/ Exhaust fan (Capacitor type) with super enamelled copper wire including cleaning & insulating the stator slots, sleeving, soldering, wrapping of cotton tape, varnishing, re-assembling & testing etc., complete:- |
| 116 | Rewinding of Ceiling Fan 1200mm Sweep |
| 117 | OVER HEAD DISTRIBUTION ALUMINIUM CABLES, ACSR CONDUCTORS, CLAMPS, JUMPERS & JOINT KITS: |
| 118 | Wiring over-head line in PVC insulated & PVC sheathed two single core aluminium conductor cable overall 1100 volts grade complete in all respect as approved and desired by the Engineer In-Charge at site. |
| 119 | PVC insulated & PVC sheathed aluminium conductor cable Overall Size 6mm² (1/1.40mm) Twin Core |
| 120 | Supply & Erection of Durable LED Batten with High quality extruded aluminium Housing 20 Watt Input AC Frequency Hz +- 3% complete along with erection of the same with, testing, in all Respect. complete in all respect as per approved /desired by the engineer in charge of work at site . The Certification and Specification of The Led fitting should be as approved by of O/o Advisior( Technical) Govt. of Punjab Letter No: AT/2021/GL/1410-1422 Dated 06-05-2021. Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab. |
| 121 | Supply and erection of BEE 3-star rating AC Celling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body 3Nos of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos, of speeds. The product should have a manufcaturer's guarantee warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer In-charge at site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysAug 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender