Power Boards / Undertakings / PSU Closing in 8 days TDR #56995416

Tender For Voltage Improvement Work At Kosady -Makkalkunnu (Cw-5638-202526-42) Es Mundakkayam

Issued by Boards / Undertakings / PSU · Kottayam, Kerala
Tender Value
7.74 Lakhs
Estimated cost
Bid Submission
21 Aug 2026
8 days left
EMD
19400
Bank guarantee accepted
Document Fee
1888
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kottayam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Voltage Improvement Work At Kosady -Makkalkunnu (Cw-5638-202526-42) Es Mundakkayam

BOQ

Name of Work:- VOLTAGE IMPROVEMENT WORK AT KOSADY -MAKKALKUNNU (CW-5638-202526-42) ES Mundakkayam
Sl. No. Item Description
1Stringing of 1.2km 11kV line with ACSR Raccoon installing TFR and allied works
2Labour charges for loading HT A type pole from the stacking place and unloading the same at work site (transportation by any vehicle).
3Labour charges for loading HT PSC pole from the stacking place and unloading the same at work site (transportation by any vehicle).
4Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 numbers of poles excluding loading& unloading charges.
5Transporting poles by hired vehicle to a distance beyond 5km and carrying upto 4 numbers of poles. (Running km)
6Transporting Transformers by hired vehicle to a distance upto 5km and carrying upto 2 numbers of 63/100/160/250kVA Transformers / Ring Main Units excluding loading& unloading charges.
7Transporting Transformers by hired vehicle to a distance beyond 5km and carrying upto 2 numbers of 63/100/160/250kVA Transformers / Ring Main Units (Running km).
8Conveyance of one km 11kV line materials from section store/stacking place to the work site (excluding poles).
9Fitting and erecting one HT A type Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing).
10Fitting and erecting one HT PSC Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing).
11Fitting and erecting one HT Double Pole Structure using A type pole in position including fitting 2 No. channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing).
12Fitting and erecting one HT Double Pole Structure using PSC pole in position including fitting 2 channel cross arms, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing).
13Fitting and providing one Strut using HT PSC pole including digging and back filling pit in ordinary soil.
14Fitting and providing one HT Fly stay for 11kV pole using HT PSC pole including digging and back filling pits in ordinary soil, drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing).
15Fitting and providing one HT Stay for 11kV pole, including digging and back filling pit in ordinary soil.
16Fitting one Additional 2.4/3m Channel cross arm (75x40x6mm), in existing 11kV DP including conveyance of materials.
17Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole including conveyance of materials.
18Fitting one set AB switch on existing DP, giving connection and drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing.
19Providing one Driven Earth using GI earth pipe of size 38.1mm dia, 2.5m length at minimum distance of 1.5m away from the pole/structure and maintaining standard distance between different earth pipes in loose soil.
20Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in ordinary soil & backfilling.
21Fitting 5 channel cross arms, AB switch, DO fuse, LA(Ord), HT & LT connections upto OH lines, etc. on existing DP structure, Fixing distribution box/provision for one set (3No.) of LT fuses, , drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing & mounting of Transformer on poles.
22Erecting one 100kVA Transformer to existing DP and giving connections, including loading from TMR/SRS/other stacking place & unloading at site but excluding cost for transporting transformer.
23Fitting one additional Fuse unit and giving connection from Transformer to fuse and Distribution box to LT OH line.
24Drilling hole of various sizes on existing Channel/Cross Arm.
25Additional rate for providing one disc set, PG clamp etc. complete, on any type of HT pole for making cut point.
26Stringing of one km 11kV line with ACSR Raccoon (3 conductors) after fitting insulators and giving jumper connections including cutting and removing tree branches wherever necessary excluding cut point works.
27Providing concrete muffing of size 0.45x0. 45x1.5m (0.5m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5sides.
28Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizondal brasing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of transportation
29Cleaning and levelling of transformer yard/RMU, spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
30Dismantling (without damage) one km LT single phase 2 wire OH line conductor by dismantling cross arms, insulators and stacking the conductors in rolls properly.
31Dismantling (without damage) one km LT three phase 4 wire OH line conductor by dismantling cross arms, insulators and stacking the conductors in rolls properly.
32Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
33Dismantling one damaged LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
34Dismantling (without damage) LT stay including digging pit in all classes of soil and backfilling.
35Stringing, shackling, fitting cross arms, insulators and binding, giving jumper connection etc. using ACSR Rabbit for Phase and Neutral, for one km LT single phase 2 wire line including cutting and removing tree branches wherever necessary and conveyance of all materials (except poles) from stacking place.
36Stringing, shackling, fitting cross arms, insulators and binding, giving jumper connection etc. using ACSR Rabbit for Phase and ACSR Weasel for Neutral, for one km LT three phase 4 wire line including cutting and removing tree branches wherever necessary and conveyance of all materials (except poles) from stacking place.
37Dismantling one section fuse from structure and bringing back to section store.
38Fitting one No. Section fuse on LT line with dropping cables, crimping sockets, connecting with bolt & nut etc.
39Disconnecting and lowering down the single phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line work.
40Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole including disconnecting and reconnecting wires.
41Additional rate for excavation of one Pit for HT Pole/HT Stay in Laterite.
42Additional rate for excavation of one Pit for HT Pole/HT Stay in Hard Laterite.
43Additional rate for excavation of one Pit for HT Pole/HT Stay in Soft Rock.
44Additional rate for excavation of Pit for A type pole in Laterite.
45Additional rate for excavation of Pit for A type pole in Hard Laterite. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56995416
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 7.74 Lakhs
LAST DATE 21-08-2026
Authority
Authority Name Kerala State Electricity Board
Work Description Tender for Voltage Improvement Work At Kosady -Makkalkunnu (Cw-5638-202526-42) Es Mundakkayam
Basic Detail
Tender No E- TENDER/2026-27/5157/22 dt. 22-07-2026
Bidding Type Tender
Location
City Kottayam
State Kerala
Key Dates
Publish Date 13 Aug 2026
Submission Date 21 Aug 2026
Open Date 22 Aug 2026
Finance
Tender Value 7.74 Lakhs
Tender Fee 1888
EMD 19400
Exemption Not Available
Document List
8e0bcee7-ec07-4ad9-8faf-0fdbb31ecb30.html
BOQ_1464535.xls
GCC.pdf
Indemnity.pdf
Slcondtns.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Aug 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Aug 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

8e0bcee7-ec07-4ad9-8faf-0fdbb31ecb30.html

xls

BOQ_1464535.xls

pdf

GCC.pdf

pdf

Indemnity.pdf

pdf

Slcondtns.pdf

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders