Tender For Repair/ Replacement Of Lt Cable, Oh Line And Connected Allied Works Under Ge Saugor
Tender Value
40 Lakhs
Estimated cost
Bid Submission
05 Sep 2026
20 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sagar → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacement Of Lt Cable, Oh Line And Connected Allied Works Under Ge Saugor
BOQ
| Sl. No. | Item Description |
| 1 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240Sqmm 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. Make- Havells/KEI/Gloster/Polycab |
| 2 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150Sqmm 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. Make- Havells/KEI/Gloster/Polycab |
| 3 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70Sqmm 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. Make- Havells/KEI/Gloster/Polycab |
| 4 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50Sqmm 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. . Make- Havells/KEI/Gloster/Polycab |
| 5 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35Sqmm 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. Make- Havells/KEI/Gloster/Polycab |
| 6 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16Sqmm 4 core including taking down existing unserviceable cable and removing from sitecomplete all as specified and directed. Make- Havells/KEI/Gloster/Polycab |
| 7 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10Sqmm 4 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. Make- Havells/KEI/Gloster/Polycab |
| 8 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10Sqmm 2 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. Make- Havells/KEI/Gloster/Polycab |
| 9 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed. |
| 10 | Excavation in trenches exc 1.5m and n exc 3.0 m depth in any type of soil and complete all as specified and directed. |
| 11 | Returning filling in excavated material including spreading, levelling, watering and well ramming in layer n.exc 25 cm thick complete all as specified and directed. |
| 12 | Removal of excavated material (soils) to a distance n exc 50m and depositing where directed at a level not exceeding 1.5m from starting point complete all as specified and directed. |
| 13 | M&L for supply and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed.Make: M/S MEHTAB TILES, M/s NITCO (NITCO), M/s SUPREME TILES (SUPREME) |
| 14 | M&L for supply and laying sand cushioning with local dry and clean sand over and under the cable for protection of cable , 80 mm thick before laying the cable and 150mm thick after laying the cable complete all as specified and directed. Note:- Only punned thickness of 180mm shall be measured for payment. |
| 15 | S&F in repair pipe galvanised iron light grade ( ISI marked )with all fittings laid in trenches or on pole, crossing of road,fixed on wall for protection of cables complete all as specified and directed of 40 mm dia complete all as specified and directed. |
| 16 | All as per item No 15 above but 50 mm dia complete all as specified and directed. |
| 17 | All as per item No 15 above but 80 mm dia complete all as specified and directed. |
| 18 | All as per item No 15 above but 100 mm dia complete all as specified and directed. |
| 19 | M&L for boring of holes by trenches less technology using machine suitable for inserting 40mm to 80mm dia (min) GI pipe so as to cross the road without damaging top surface of road including getting out and disposal of excavated earth, at a lead up to 50m and lift up to 1.5m complete all as specified and directed. |
| 20 | \\"M&L for supply and fix steel tubular swaged pole 410 SP-31 (9.0 metre long) in true vertical position, conforming to IS:2713 (part 1 to 3) with CI base plate, finial taper plug, bolts, nuts & screws etc including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and two coat of synthetic enamel paint over primer on embedded portion/coping of pole, making strips of width 30 cm up to 1.5 m from the ground level in black and white shade in alternate layer and numbering of poles with synthetic enamel paint of approved shade including taking down of existing old pole of any description and making good surface to match existing area complete all as specified and as directed.Note : (i) Required earth work shall be measured and paid separately under respective item.(ii) The poles shall be marked it's designation, manufacturer's identification and year of manufacturing. (iii) Cost of painting, marking strip and numbering pole shall be deemed included in quoted unit rate.\\" |
| 21 | Supply and fixing in replacement of cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed inclusive of one primer coat, one under coat and one finishing coat of paint. complete all as specified and directed. |
| 22 | M&L in repair of aluminium conductors steel reinforced (ACSR conforming to IS : 398) Part-II)-1976 for HT/LT over head lines on PCC/ steel/rail poles including Aluminium binding wire complete all as specified of existing size. |
| 23 | Material and labour for GI wire 4mm dia (8 SWG) stretching and fixing on pole for continious earth conductor, Guard wire 3.2 mm (10 SWG) for cradle (Hexagonal/rectangular) including binding wire all as specified and directed.. |
| 24 | S&F pin type polymer/porcelain, vitreous, white, brown or green insulator including Galvanised Mild Steel spindle, two Galvanised iron washers and one GI nut 100 mm height , 65 mm dia suitable for 1100 Volt working pressure grade (LT) complete all as specified and directed including dismantling of old u/s insulators |
| 25 | S&F shackle type polymer/porcelain, vitreous, white, brown or green insulator including Galvanised Mild Steel straps, washers, suitable bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 volts working pressure grade complete all as specified and directed including dismantling of old u/s insulators. |
| 26 | M & L for plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate in foundation of PCC poles/ struts, etc. including form work complete all as specified and directed |
| 27 | M & L for plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of stay assy/ pole etc, including form work complete in all as specified and directed |
| 28 | M & L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate for coping/plinth of poles, including necessary form work finished even & smooth without using extra cement all as specified and directed |
| 29 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 meters below normal ground level surrounded from all sides by mixture of charcoal & common salt & electrode connected to and including galvanised earth wire 4.0 mm dia as earthling lead by means of bolts, nuts, check-nuts, and washers of galvanised iron and GI protection pipe light grade 40 mm dia connected to earth point , GI pipe light grade 20 mm dia for watering funnel with wire mesh all as specified & indicated in Electric plate no 3 of SSR 2020 part I complete . |
| 30 | M&L for Earthing with galvanised steel earth plate electrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized Flat iron of size 25x4mm as earth lead strip by means of bolts, nuts, check nuts & washers, provision of 40mm GI pipe light grade as watering pipe with funnel and wire mess, 40mm GI pipe light grade as earth lead (GI strip) protection pipe, RCC test chamber with cover, filling charcoal and salt in 15mm thick alternative layer starting from charcoal bottom layer to ensure packed thickness not less than 15 Cm on all sides of earth plate complete all as shown in electric plate no 3, connected to earthing test point including required earth work (excavation, returning filling and removal of surplus excavated soil) and testing on completion complete all as specified, shown/indicated on Drg and as directed by Engg-in-charge. |
| 31 | \\"M&L for supply, installation, connecting, commissioning and testing CPRI approved factory fabricated bus bar panel board , in repair, outdoor type, both side operable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, free standing/ floor mounting, dust and vermin proof, fabricated from 3.15 mm thick CRCA MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade with 4Nos 400 Amps insulated high conductivity copper bus bar, conforming to IS, cable glands, lugs etc including required PCC work and Iron work for fixing arrangement at site complete all as specified and as directed. Note : (i) PCC work and Iron work shall be measured and paid separately under respective item. (ii) The contractor shall get approved the design of LT panel fromEnng-in-charge before procurment.Contractor shall produce the invoice and MTC to the Engineer-in-charge who shall verify the genuineness of Invoice, recorded in MB and kept in record duly defaced. Production of Invoice and MTC is mandatory along with RAR. \\" |
| 32 | \\"M&L for supply, installation, connecting, commissioning and testing CPRI approved factory fabricated bus bar panel board , in repair, outdoor type, both side operable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, free standing/ floor mounting, dust and vermin proof, fabricated from 3.15 mm thick CRCA MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade with 4Nos 200 Amps insulated high conductivity copper bus bar, conforming to IS, cable glands, lugs etc including required PCC work and Iron work for fixing arrangement at site complete all as specified and as directed. Note : (i) PCC work and Iron work shall be measured and paid separately under respective item. (ii) The contractor shall get approved the design of LT panel fromEnng-in-charge before procurment.Contractor shall produce the invoice and MTC to the Engineer-in-charge who shall verify the genuineness of Invoice, recorded in MB and kept in record duly defaced. Production of Invoice and MTC is mandatory along with RAR. \\" |
| 33 | Supply and fixing stay assembly complete with accessories shown in electrical plate No 1 with stay rod of 16 mm dia including loop insulator suitable for 1.1 KV (size 65x90 mm) with clearance of hole 16 mm and MS stay plate size 230 x 230 x 6mm, stay clamps etc complete all as specified. |
| 34 | M&L for galvanised stay strand 7/3.15 mm or 7/4.00 mm size with minimum tensile strength of 700 N/ Sqmm and conforming to IS : 2141-1979 complete all as specified & directed. |
| 35 | Re-Streaching of Aluminium reainforced condutor by opening from insulators and refixed with streached complete all as per directed |
| 36 | Supply ,Laying and spreading of 40mm graded stone aggregate complete all as specified and directed. |
| 37 | M&L in replacement of stranded aluminium conductor flat twin core PVC insulated unsheathed 1100V 10 Sqmm 2 core. Make: Havells/Polycab/Finolex/Plaza |
| 38 | M&L in replacement of stranded aluminium conductor flat twin core PVC insulated unsheathed 1100V 6 Sqmm 2 core. Make: Havells/Polycab/Finolex/Plaza |
| 39 | M&L for Digital Multifuction meter with selector switch to measure ampere, voltage frequency etc to be fixed in existing LT panel complete all as specified and directed. |
| 40 | M&L for current transformer of ratio 200/5 to be fixed in existing LT panel connecting to existing meter/new meter complete all as specified and directed. |
| 41 | M&L for current transformer of ratio 100/5 to be fixed in existing LT panel connecting to existing meter/new meter complete all as specified and directed. |
| 42 | Supply and fixing in replacement of MCCB 4 pole , 400 amp rating of 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed. Make: Havells/L&T/Schneider/Legrand |
| 43 | Supply and fixing in replacement of MCCB 4 pole , 250 amp rating of 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed. Make: Havells/L&T/Schneider/Legrand |
| 44 | Supply and fixing in replacement of MCCB 4 pole , 200 amp rating of 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed. Make: Havells/L&T/Schneider/Legrand |
| 45 | Supply and fixing in replacement of MCCB 4 pole , 160 amp rating of 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed. Make: Havells/L&T/Schneider/Legrand |
| 46 | Supply and fixing in replacement of MCCB 4 pole , 100 amp rating of 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed. Make: Havells/L&T/Schneider/Legrand |
| 47 | Supply and fixing in replacement of MCCB 4 pole , 63 amp rating of 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed. Make: Havells/L&T/Schneider/Legrand |
| 48 | M&L LT line PVC spacers spiral type for two/three/four line (separator) complete all as specfied and directed. |
| 49 | S & F of aluminium lugs 25 sqmm to 95 sqmm lugs complete all as specified and directed. |
| 50 | S & F of aluminium lugs 120 sqmm to 400 sqmm lugs complete all as specified and directed. |
| 51 | S & F of copper lugs 25 sqmm to 240 sqmm lugs complete all as specified and directed. |
| 52 | S&F cable route marker with suitable reinforcement of size 50x20x10cm with latter inscribed on both side as MES LT CABLE of specified ront side not les then 60mm as directed and mounted on pcc 40x30x30 cm complete using PCC 1:2:4 B-1 using 20mm graded stone aggregade and including painting using cement bsed paint to the satisfaction of Engr in Charge . |
| 53 | M&L for Cutting /trimming of tree branches upto 80 mm girth along LT/HT OH electric lines which or growing /touching or falling on ACSR conductor /poles or near by sub stns etc at any height from GL and making sufficient clearance not less than 1.5 mtr from ACSR conductor/ poles/ structure and taking down the same on the ground carefully avoiding the damage of and removing to a distance including stretching of conductor as required where directed by Engr - in -charge. Note :- Tree cutting will be maintain for periodicity for three months depending upon the growth of tree branches. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender