Tender For Repair To Lt Ug Cables, Oh Lines, Security Lights Etc And External Water Supply Distribution Lines, Control Valves And Allied Works At Cqa(V) And Dad Complex Under Ge (S) Ahilyanagar
Tender Value
35 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
9 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ahmednagar → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Lt Ug Cables, Oh Lines, Security Lights Etc And External Water Supply Distribution Lines, Control Valves And Allied Works At Cqa(V) And Dad Complex Under Ge (S) Ahilyanagar
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator)/manual means, in foundation trenches or for shafts, wells, cesspits, manholes, pier holes, laying pipe or pipes or drains, not exceeding 1.5 m in width or 10 sqm on plan, including dressing of sides and ramming of bottoms, for lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil, within a lead of 50 m complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick with soils, complete all as specified and as directed. |
| 3 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 185 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning complete including taking out old unserviceable cable complete all as specified and as directed.Note :- Excavation and earthwork shall be measured and paid separately. |
| 4 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 150 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning complete including taking out old unserviceable cable complete all as specified and as directed.Note :- Excavation and earthwork shall be measured and paid separately. |
| 5 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 120 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning complete including taking out old unserviceable cable complete all as specified and as directed.Note :- Excavation and earthwork shall be measured and paid separately. |
| 6 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 95 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning complete including taking out old unserviceable cable complete all as specified and as directed.Note :- Excavation and earthwork shall be measured and paid separately. |
| 7 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 70 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning complete including taking out old unserviceable cable complete all as specified and as directed.Note :- Excavation and earthwork shall be measured and paid separately. |
| 8 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 50 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning complete including taking out old unserviceable cable complete all as specified and as directed.Note :- Excavation and earthwork shall be measured and paid separately. |
| 9 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 35 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning complete including taking out old unserviceable cable complete all as specified and as directed.Note :- Excavation and earthwork shall be measured and paid separately. |
| 10 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 25 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning complete including taking out old unserviceable cable complete all as specified and as directed.Note :- Excavation and earthwork shall be measured and paid separately. |
| 11 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 16 Sqmm, 4 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning complete including taking out old unserviceable cable complete all as specified and as directed.Note :- Excavation and earthwork shall be measured and paid separately. |
| 12 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 10 Sqmm, 2 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning complete including taking out old unserviceable cable complete all as specified and as directed.Note :- Excavation and earthwork shall be measured and paid separately. |
| 13 | S&F in replacement 80 mm bore galvanised steel tubing, light grade, ISI marked, for protection of under ground cable on pole/wall/under road including clamps where reqd and taking out old unserviceable pipe complete all as specified and as directed. |
| 14 | S&F in replacement 50 mm bore galvanised steel tubing, light grade, ISI marked, for protection of under ground cable on pole/wall/under road including clamps where reqd and taking out old unserviceable pipe complete all as specified and as directed. |
| 15 | M & L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole and similar work etc etc including necessary formwork complete all as specified and as directed. Complete all as directed by Engineer-in-Charge. |
| 16 | M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron earth strip 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 32mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. |
| 17 | M&L for taking out old unserviceable MCCB TPN from existing LT panel board and supply and fix MCCB TPN 63 amps capacity rup capacity 16 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB complete with replacement of incoming and out going cable connection with lugs, aluminium conductor cable of proper size, nuts bolts all as directed. |
| 18 | M&L for taking out old unserviceable MCCB TPN from existing LT panel board and supply and fix MCCB TPN 100 amps capacity rup capacity 16 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB complete with replacement of incoming and out going cable connection with lugs, aluminium conductor cable of proper size, nuts bolts all as directed. |
| 19 | M&L for taking out old unserviceable MCCB TPN from existing LT panel board and supply and fix MCCB TPN 160 amps capacity rup capacity 16 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB complete with replacement of incoming and out going cable connection with lugs, aluminium conductor cable of proper size, nuts bolts all as directed. |
| 20 | M&L for taking out old unserviceable MCCB TPN from existing LT panel board and supply and fix MCCB TPN 200 amps capacity rup capacity 36 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB complete with replacement of incoming and out going cable connection with lugs, aluminium conductor cable of proper size, nuts bolts all as directed. |
| 21 | M&L for taking out old unserviceable MCCB 4P from existing LT panel board and supply and fix MCCB 4P 400 amps capacity, adjustable type, rup capacity 36 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB complete with replacement of incoming and out going cable connection with lugs, aluminium conductor cable of proper size, nuts bolts all as directed. |
| 22 | M&L for taking out old unserviceable MCCB 4P from existing LT panel board and supply and fix MCCB 4P 160 amps capacity, adjustable type, rup capacity 36 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB complete with replacement of incoming and out going cable connection with lugs, aluminium conductor cable of proper size, nuts bolts all as directed. |
| 23 | S&F in replacement of post top lantern light decorative type post top for 360 degree indirect light IP 65 protection resistant to impact and corrosion, Glare-free and better uniformity 20 watt LED 230 V 50 Hz including necessry fitting accessories complete all as per directed by engineer-in-charge. Make : - Havells Cat No. CORALPT25WLED757PSYMTOPC or equivalent model of makes specified. |
| 24 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor 6 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular including taking down old unserviceable cable complete all as specified and directed. |
| 25 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor 10 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular including taking down old unserviceable cable complete all as specified and directed. |
| 26 | S&F in repairs, MCB DB 4 way TPN, double door as in distribution board (when MCBs are to be used), 415 volts, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming as per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper bus bar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 27 | S&F in repairs ISOLATOR TPN, AC 415 V, 63 amps, 10 KA capacity ,'C' series, making connection with suitabl size of copper lugs etc complete all as specified and as directed. |
| 28 | S&F in repairs, MCB SP, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'c' series, making connection with suitable size of copper lugs etc complete all as specified and as directed. |
| 29 | S&F in repairs, LED flood light fitting, 70 watt, 230V AC outdoor type with thermal management in multiple optics and equipped with IP65/66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.Make : - Havells Cat No. JETAALBAFLOODLIGHT70Wor equivalent model of makes specified. |
| 30 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 50mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24 Type 450N, laid in trenches for cable protection, complete all as specified and as directed. |
| 31 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 63mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24 Type 450N, laid in trenches for cable protection, complete all as specified and as directed. |
| 32 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 110mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24 Type 450N, laid in trenches for cable protection, complete all as specified and as directed. |
| 33 | M&L heat shrinkable straight through cable joint kit suitable for 10 to 16 Sqmm 4 core LT XLPE cable 1100 Volts grade complete with jointing material and accessories and testing including necessary excavation / earth work complete all as specified and as directed. |
| 34 | M&L heat shrinkable straight through cable joint kit suitable for 25 to 50 Sqmm 3.5 core LT XLPE cable 1100 Volts grade complete with jointing material and accessories and testing including necessary excavation / earth work complete all as specified and as directed. |
| 35 | M&L heat shrinkable straight through cable joint kit suitable for 70 to 120 Sqmm 3.5 core LT XLPE cable 1100 Volts grade complete with jointing material and accessories and testing including necessary excavation / earth work complete all as specified and as directed. |
| 36 | Supply install in replacement and testing out door wheather proof bus bar chamber of size 100 cm x 60cm x 30cm made out of 3.15mm CRCA MS sheet having one side openable hinged door shuter with looking arangement/provn of two nos 80cm long 40x40x6mm angle iron legs welded and 04 nos Aluminium bus bar of 200 Amp rating provn of one MCCB TPN 100 Amp 25 KA for controlling Electric supply complete errected on ground with necessary PCC 1:3:6 type C2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland , lugs/thimbles all as specified. |
| 37 | Material and labour for preparation of surfaces for LT pole painting by scrapping damaged paint and painting with two coats of silver aluminium paint and alternate painted strip of 30 cm width of colour as approved by Accepting officer upto 1.5 meter height from bottom of the pole and writing pole No with black paint on yellow circuit all as directed by Engineer-in-Charge. |
| 38 | Trimming of tree branches touching to the LT/HT over head line or near to the LT/HT over head line as per the direction of AGE E/M/JE incharge complete including removing the tree branches from site complete all as specified and directed.Note : (i) Written shut down shall be obtained from concerned JE/AGE (E/M) before taking the trimming work in hand by contractor. (ii) Span from one pole to next pole (30 to 50 RM) will be considered as a one Job (iii) Any damage caused due to negligence of workmen will be rectified without any extra payment (iv) T & P such as ladder, rope, cutter, Axes and other related material will be provided by the contractor. |
| 39 | Cleaning of bushes /small plants up to root level aruound and surrounding area E/M installations (i.e two pole / four pole structures,out door substation yards & misc E/M installations etc including surface dressing n.exc 15 cm deep and removing debris to distance n.exc 50m complete all as specified and directed by Engr-in-charge. |
| 40 | S & F in replacement of Manual Change over switch of capacity 63 Amp complete all connections including Taking down old change over box all as specified and directed. |
| 41 | S & F in replacement of Manual Change over switch of capacity 100 Amp complete all connections including Taking down old change over box all as specified and directed. |
| 42 | S & F in replacement of Manual Change over switch of capacity 200 Amp complete all connections including Taking down old change over box all as specified and directed. |
| 43 | Dismantling of ACSR or AAC conductors of any size and any description from any height/ poles or any location complete all as specified and as directed by Engr in Charge. |
| 44 | Dismantling of cradles, guard wire, earth wire, of galvanised steel wire 4mm dia of any type complete all as specified and as directed . |
| 45 | Dismantling of Unserviceable LT insulators Pin/ shackle/ Disc & loop type from existing OH lines complete all as specified and directed by Engr in Charge. |
| 46 | Dismantling of unserviceable cross arms, bracings, supports, clamps etc from LT pole of any type/shape complete all as specified and directed. |
| 47 | M& L for PVC insulated sheathed 3 Core copper conductor cable of size 1.5 sqmm in PVC Conduit 20 mm dia for street light connection of length as per site requirement from junction box to street light complete all as specified and directed . Please Enable Macros to View BoQ information |
| 48 | M& L for PVC insulated sheathed 3 Core copper conductor cable of size 1.5 sqmm in PVC Conduit 20 mm dia for street light connection of length as per site requirement from junction box to street light complete all as specified and directed . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysSep 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender