Tender For Repairs To Domestic Air Conditioners,Water Cooler,Refrigerator And Voltage Stabilizers At Itr Technical Area, Otm Bldgs Under Age E/M Chandipur And Repair/Repalcement Of Certain Flame Proof Sub-Main And Point Wiring, Dbs And Mccbs/Mcbs, Fl

Issued by Statutory Bodies & Commissions/Committees · Baleshwar, Odisha
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Aug 2026
14 days left
EMD
69200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baleshwar → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs To Domestic Air Conditioners,Water Cooler,Refrigerator And Voltage Stabilizers At Itr Technical Area, Otm Bldgs Under Age E/M Chandipur And Repair/Repalcement Of Certain Flame Proof Sub-Main And Point Wiring, Dbs And Mccbs/Mcbs, Flame Proof Fittings, Lightning Protection System,Earthing And Allied Works At Itr And Lcs Area Under Age E/M Chandipur

BOQ

Name of Work:- Repairs to domestic air conditioners,water cooler,Refrigerator and Voltage stabilizers at ITR Technical area, OTM Bldgs under AGE E/M Chandipur and Repair/repalcement of certain flame proof sub-main and point wiring, DBs and MCCBs/MCBs, flame proof fittings, lightning protection system,earthing and allied works at ITR and LCs area under AGE E/M Chandipur
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (I) R&D CHANDIPUR Name of Work: Repairs to domestic air conditioners,water cooler,Refrigerator and Voltage stabilizers at ITR Technical area, OTM Bldgs under AGE E/M Chandipur and Repair/repalcement of certain flame proof sub-main and point wiring, DBs and MCCBs/MCBs, flame proof fittings, lightning protection system,earthing and allied works at ITR and LCs area under AGE E/M Chandipur Contract No: GE(I)R&D/BLS/ 2026-27 Bidder Name : SCHEDULE 'A' (BOQ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Work / Item Item Code / Make Number or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE (including all Taxes as specified in tender Documents) In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2M&L for Cleaning, servicing including carrying out preventive maintenance of summer appliances viz. indoor and out door unit of Split Air conditioners and complete unit of Split ACs of 1.5TR capacity using suitable cleaning solution, chemicals, tools and minor spares viz. screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. Cleaning of the condensor, evaporator, fins and cooling coils shall be done using Blower / Vacuum cleaner, cleaning clothes, nylon brushes etc till scales and dirts are removed including cleaning of drain pipe line and replacement of unserviceable spares if any and ensuring its serviceability by keeping the AC in good working condition all as specified and directed by Engineer-in-Charge. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as \\"Supplied only\\" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge.
3All as per item no.1 above but for Split Type AC 2.0 TR Capacity
4All as per item no.1 above but forSplit Type AC 3.0 TR Capacity
5All as per item no.1 above but forWindow type AC 1.5/2 TR Capacity
6All as per item no.1 above but for water cooler / refrigerator of any type, size and capacity as described below. The inner water tank of water cooler should be cleaned using bleaching powder and keeping the inner tank clean from bacteria and formation of scales and ensuring its serviceability all as specified and as directed by Engineer-in-Charge.
7Supply only thermostat for water cooler / refrigerator / deep freezer of any capacity and make.
8Supply only relay for any type of water cooler /refrigerator/deep freezer of any capacity & make.
9Supply only PCB suitable for split type A/C 1.5 TR capacity of any make/ model
10Repair of old PCB fitted in existing split type A/C 1.5 TR capacity of any make/ model, opening up for inspection/checking and make sure the serviceability of incoming/outgoing connections etc and reassembling the same with dismantled component after replacement of burnt spare parts and internal wiring complete all as directed and specified by Engineer-in-Charge.
11Supply only PCB suitable for split type A/C 2 TR capacity of any make/ model
12All as per item no.09 above but for split type A/C 2 TR of any make/model
13Supply only Digital Display Unit suitable for split / window type A/C 1.5/ 2 TR of any make and model.
14Supply only Air sensor/Coil Sensor suitable for split / window type A/C 1.5/2.0 TR of any make/ model
15Supply & fixig copper pipe of size 1/2,1/4 suitable for window / split type A/C1.5/ 2 TR of any make/ model
16Supply only Running capacitor 45/45+6 mfd for Window / Split type Air conditioner of of any capacity.
17Supply only Running capacitor 36 mfd for air conditioner of any capacity & water cooler of any capacity
18Supply only Running Capacitor capacitor 50/50+5 mfd for Air conditioner 2 Ton Capacity
19Supply only Capacitor of 2.50/3/3.15 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model .
20Supply only capacitor of 6 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model .
21Supply only capacitor of 8 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model.
22Supply only capacitor of 10 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model.
23Supply only auto swing motor for indoor unit of split A/C of capacity 2/1.5 TR of any make and model to match with existing design conditions.
24Supply only Power contactor suitable for Split AC of 1.5/2.0 TR capacity of any make and model to match with existing design conditions.
25Supply only Brass angle valve of size 5/8 inch for split AC 1.5/2TR capacity.
26Supply only Brass angle valve 1/4 inch for split AC 1.5/2TR capacity.
27Supply only Brass angle valve 1/2 inch for split AC 1.5/2TR capacity.
28Supply only Nitrile Foam Insulation for copper tube of size 5/8 inch suitable for split AC including provision of requisite PVC fasteners.
29Supply only Nitrile Foam Insulation for copper tube of size 1/4 inch suitable for split AC including provision of requisite PVC fasteners..
30Supply only Nitrile Foam Insulation for copper tube of size 1/2 inch suitable for split AC including provision of requisite PVC fasteners..
31Supply only PVC ball valves / float valve for water cooler of any capacity & make
32Supply only brass chromium plated push button tap outer / Inner thread ISI marked suitable for water cooler of any type of size 15 mm.
33Supply only Thermostat for Window AC of capacity 1.5 TR/2.0 TR to match with existing design conditions.
34Supply only in repair Selector Switch for window type AC and to match with existing design conditions..
35Supply only blower drum suitable for Split/Window type AC of any capacity and to match with existing design conditions..
36Supply only Remote Universal type suitable for all type of split / window AC of any make and model or any capacity and to match with existing design conditions..
37Supply only PVC Drain pipe of size 1/2\\" size suitable for Split type AC of any capacity.
38Supply only , main Drain pipe of indoor unit of size 3/4 \\", PVC Flexible type suitable for Split type AC of any capacity.
39Supply only Rubber Bush for Fan Motor of out door unit of split type AC and Window type AC of any capacity and any make and model .
40Supply only Flairing Nuts of Size 5/8 for out door unit of Split type AC of Any make and model.
41Supply only Flairing Nuts of Size 1/2 for out door unit of Split type AC of Any make and model.
42Supply only Flairing Nuts of Size 1/4 for out door unit of Split type AC of Any make and model.
43Taking out unserviceable Receprocating type compressor of Window /Split Type AC 1.5 Ton capacity, from site and replacement of compressor with new one to match with existing make/Model (R Compressor) and fixing of new compressor sealed unit in position, charging required quantity of refrigerant gas as per existing design of AC, brazing of discharge and suction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
44All as per item no.42 above but for 2.0 TR capacity.
45Taking out unserviceable Rotary type compressor of Window/ Split Type AC 1.5 Ton capacity, from site and replacement of compressor with new one to match with existing make/Model (R Compressor) and fixing of new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a as per existing design of AC, brazing of discharge and suction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
46All as per item no.44 above but for Window/Split type AC 2.0 TR capacity.
47M&L for Gas charging with R-22 refrigerant gas for Split / Windows ACs of any make, model and capacity, Refrigerator and Water coolers of any make, Model of any capacity in position or by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging.
48M&L for Gas charging with R-407/R-410/R-410A/R32 refrigerant gas for Split / Windows ACs of any make, model and capacity, Refrigerator and Water coolers of any make, Model of any capacity in position or by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging.
49Taking down unserviceable Fan Motor of Window / Split type AC 1.5/2.0 TR capacity and of any make and model, removing burnt winding, insulation material, cleaning the surfaces, rewinding the motor with super enameled copper winding wire of same gauge and size including insulation material and varnishing and re-fixing at site all as directed by Eng-in-Charge.
50Supply and fixing in repair Fan motor assembly of outdoor unit of split AC 1.5/2TR/3TR & Window type AC of any make and model and all as directed.
51Supply and fixing in repair Blower Fan motor assembly of indoor unit of split AC 1.5/2TR of any make and model and all as directed.
52Taking down unserviceable Condenser fan motor of water cooler/refrigerator/deep freezer of any capacity, make and model, removing burnt winding, insulation material, cleaning the surfaces, rewinding the motor with super enameled copper winding wire of same gauge and size including insulation material and varnishing and re-fixing at site all as directed by Eng-in-Charge.
53Supply and fixing in repair Condenser Fan motor ISI marked water cooler of any capacity, make and model and all as directed.
54Supply and fixing in repair, Out door Bracket ISI marked suitable for fixing out door unit of Split type ACs of any make and capacity along with MS clamps, bracings, supports, bolts, nuts & washers, PVC rawl plug etc and making good disturbed surface of wall in CM 1:3 including painting to match with existing surface and all as directed.
55Supply and fixing in repair Condenser Fan Blade marked suitable for 1.5 / 2 Ton Split Type Air conditioner & window type AC of any make and model and all as directed.
56Supply and fixing in repair Fan Blade suitable for Water Cooler of any capacity / Make and model and all as directed.
57Taking down existing split type AC indoor and outdoor units complete of any make / capacity after disconnecting all accessories and Refixing at a different location including making necessary fixing arrangements, after carrying out necessary maintenance / servicing including testing on load at site complete all as specified and directed by Engineer - in- charge . Note:- vacuuming / Gas Charging / spares parts etc if required will be measured and paid seperately under revelent Items of schedule of works .
58M/L for carrying out spray painting complete unit of window type AC of any make, model and capacity after dismantling, and painting on sheet metal enclosers interanally and externally with two coats of synthetic enamel paint of approved make and shade after preparation of surface and writing the MES/SM Nos, re-assembling and reconnecting the AC unit at its installed location complete all as directed.
59All as per item No 57 above but for outdoor unit of split AC of any capacity make and model.
60Supply and fixing in repair Copper Condenser Coil ISI marked suitable for Window type AC of 1.5TR capacity of any make and model to match with existing design conditions.
61Supply and fixing in repair Copper Condesser Coil ISI marked suitable for Window type AC of 2.0 TR capacity of any make and model to match with existing design conditions.
62Supply and fixing in repair Copper Condesser Coil ISI marked suitable for Split type AC of 1.5 /2.0TR capacity of any make and model to match with existing design conditions.
63Supply and fixing in repair Cooling Coil suitable ISI marked for Window type AC of 1.5 TR capacity of any make and model to match with existing design conditions.
64Supply and fixing in repair Cooling Coil ISI marked suitable for Window type AC of 2.0TR capacity of any make and model to match with existing design conditions.
65M &L for Sub main wiring in PVC conduit of required size 2 run of 6 sqmm PVC insulated copper conductor cable wih one run of 4 sqmm PVC insulated copper conductor cable as continuity earth wire, including taking down existing old unsv point wiring , all as speified and directed .
66Supply and fixing in repair 3 Core 2.5 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for AC / water cooler / Refrigerator / AC / Voltage stabilizer.
67Supply and fixing in repair single Core 1.5 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for AC / water cooler / Refrigerator / AC / Voltage stabilizer.
68Supply and fixing in repair single Core 2.5 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for AC / water cooler / Refrigerator / AC / Voltage stabilizer.
69Supply and fixing in repair Electronic Circuit Board Suitable for Out door unit of Split type AC 1.5/2.0 TR (Inverter model ) and all as per Existing make and model , All as specified and directed by Engr - in - Charge
70S & F in repair complete outdoor unit with and including condensor coil, compressor, outdoor fan with motor for split AC of 1.5 TR capacity complete all as specified and directed
71Supply and fixing in repair Electronic Circuit Board Suitable for Variable Refrigerant Volume Outdoor Unit of DC inverter I series model 38VR024H119013 (Inverter model ) 24 HP and all as per Existing make and model , All as specified and directed by Engr - in - Charge
72Supply and Replace compressor for water cooler 40/80 Ltr capacity and assembling and resting the compressor unit complete all as directed by Engineer- in -charge.including taking down, Make : DANFOSS/ LG/ Tecumseh.
73Repair to body of water cooler by providing MS sheet 2mm thick including welding, replacement of wornout nuts & bolts and repair/fabrication of the compressor mounting base as per existing fabrication work including all as directed and specified ( Approx area of MS Sheet 0.75 Sqmtrs) and painted by two coats of synthetic enameled paint of existing cooler over a coat of red oxide primer.
74S & F in repair indoor blower wheel for split AC of 1.5/ 2.0 TR capacity complete all as specified and directed
75Supply and fix Universal PCB suitable for window/Split AC 1.5/2.0 TR capacity of any make/ model
76S & F in repair complete indoor unit with and including evaporator coil, blower fan with motor body etc for split AC of 1.5/ 2.0 TR capacity complete all as specified and directed
77Repair to body of Window AC/Outdoor unit of Split AC by providing MS sheet 2mm thick including welding, replacement of wornout nuts & bolts and repair/fabrication of the compressor mounting base as per existing fabrication work including all as directed and specified ( Approx area of MS/GI Sheet 0.5 Sqmtrs) and painted by two coats of synthetic enameled paint of existing cooler over a coat of red oxide primer.
78Supply and fixing in repair Electronic Circuit Board Suitable for Indoor/outdoor unit of Split type AC 1.5/2.0 TR (Inverter model ) and all as per Existing make and model , All as specified and directed by Engr - in - Charge
79Supply and fixing in repair /replacement of MCB Protected Power unit comprising of suitable capacity SPN MCB, 3 pin Socket and On/Off Motor Starter suitable for controlling AC and including making good to existing disturbed works completete all as directed and specified, and taking down old unserviceable plug socket for offering credit.
80S & F in repair complete outdoor unit with and including condensor coil, compressor, outdoor fan with motor for split AC of 2.0 TR capacity complete all as specified and directed
81Supply and Fix in repair,voltage stabilizer for automatic operation, single phase, naturally air cooled designed for input voltage variation between 140V to 280V with output voltage stabilized at 230V with accuracy of + 2.5%,capacity 4 KVA,complete all as specified and directed.
82Supply and Fix in repair,voltage stabilizer for automatic operation, single phase, naturally air cooled designed for input voltage variation between 140V to 280V with output voltage stabilized at 230V with accuracy of + 2.5%,capacity 5 KVA,complete all as specified and directed.
83Repair of voltage stabilizer of any capacity ( 1 to 5 KVA) and make, opening up for inspection/checking serviceability of voltage regulating transformer relays, circuit board, voltmeters, incoming/outgoing connections etc and reassembling the same with dismantled component after replacement of burnt spare parts and internal wiring complete all as directed and specified by Engineer-in-Charge.Note. Replacement of spare parts shall be measured and paid separately under items below :-
84Supply only transformer of any capacity between 4 to 5 KVA including taking down.
85Supply only transformer of any capacity between 1 to 3 KVA including taking down.
86Supply only square/ round type voltmeter of size 2\\" x 2\\" for various voltage stabilizers including taking down.
87Supply only transformer relay for various capacity of stabilizers including taking down.
88Supply only circuit board for various capacity of stabilizer including taking down.
89Supply only 3 way connector for voltage stabilizer including traking down
90Supply & Fix in replacement polythylene soft thermocol of size 180x90x4 cm for window type AC side packing during AC installation
91Taking out unserviceable Inverter type compressor of Window /Split Type AC 1.5 Ton capacity, from site and replacement of compressor with new one to match with existing make/Model (R Compressor) and fixing of new compressor sealed unit in position, charging required quantity of refrigerant gas as per existing design of AC, brazing of discharge and suction line including leak testing complete as directed by the Engineer-in-charge Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost.
92Supply and Replace compressor for rerigerator 195 Ltr capacity and assembling and resting the compressor unit complete
93Taking down of RO water purifier (Kent/aquaguard/usha) for repairing, servicing, cleaning etc, replacement of unserviceable parts such as PCB, all filters, membrane, solenoid valve, uv lamp and other minor parts completete all as directed and specified
94S & F in repair indoor AC bracket for split AC of 1.5/ 2.0 TR capacity complete all as specified and directed
95Taking down flameproof aluminium point wiring of light, FLP power itch/socket etc. complete, including connected fitting and fixtures such as junction box,terminal box by unscrewing from board,metalic hose conduit (excluding flameproof luminaires,FLP rotary switches, FLP power switch/socket & plug to be measured seperately) from hangers and removing materials to store and keeping in safe custody for disposal as per credit schedule and making good dusturbed surfaces of walls, floors, etc. to match with existing and complete all as specified and directed by Engr-In-Charge
96M & L for flame proof point wiring with PVC insulated sheathed heat resistance, FRLSH, single core copper cable Conforming to IS-694 of size 1.5 Sqmm with stranded copper conductor drawing through flame proof ERW steel surface conduit with all fittings and accessories for connecting FLP rotary switches, light fittings & fixtures etc including 1.5 Sqmm heat resistant and fire retardant copper conductor cable as in continuous earthing for One light / fan points controlled by one FLP rotary switch.
97M & L for flame proof point wiring with PVC insulated sheathed heat resistance, FRLSH, single core copper cable Conforming to IS-694 of size 1.5 Sqmm with stranded copper conductor drawing through flame proof ERW steel surface conduit with all fittings and accessories for connecting FLP rotary switches, light fittings & fixtures etc including 1.5 Sqmm heat resistant and fire retardant copper conductor cable as in continuous earthing for two light / fan points controlled by one FLP rotary switch.
98M & L for flame proof point wiring with PVC insulated sheathed heat resistance, FRLSH, single core copper cable Conforming to IS-694 of size 2.5 Sqmm with stranded copper conductor drawing through flame proof ERW steel surface conduit with all fittings and accessories for connecting FLP rotary switches, light fittings & fixtures etc including 2.5 Sqmm heat resistant and fire retardant copper conductor cable as in continuous earthing for two light / fan points controlled by one FLP rotary switch.
99M & L for flame proof point wiring with PVC insulated sheathed heat resistance, FRLSH, single core copper cable Conforming to IS-694 of size 4 Sqmm with stranded copper conductor drawing through flame proof ERW steel surface conduit with all fittings and accessories for connecting FLP rotary switches, light fittings & fixtures etc including 4 Sqmm heat resistant and fire retardant copper conductor cable as in continuous earthing for . 15 amps, independent, with cables One 3 pin socket outlet complete all as specified and directed by Engr-In-Charge.
100S & F flame proof rotary switches with cable in LM6 single pole ON/OFF 10/16 Amps
101S & F flame proof rotary switch including socket and plug combined in LM6 cable termination box of capacity 16 A, 250 V, 2 P+earth complete all as specified and directed by Engr-In-Charge
102S & F flame proof rotary switch including socket and plug combined in LM6 cable termination box of capacity 16 A, 250 V,4P+earth complete all as specified and directed by Engr-In-Charge
103Supply and fixing Flameproof/Weatherproof Flood light fitting wall mounted, aluminium alloy LM6 with IP66 degree of protection, of capacity 70 watt LED light with lamp, driver etc, light gray epoxy powder coated 1 no internal and 2 nos external earthing with SS hardware along with 2 nos 3/4\\" ET cable entries with suitable double compression brass nickel plated cable gland,type A toughened glass certified by CIMFR,Dhanbad for Gas Group IIC complete all as specified and directed
104All as per item No.104 above but of capacity 120 W
105All as per item No.104 above but of capacity 150W
106Supply and fixing LED light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 66 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable complete all as specified and directed by Engr-In-Charge
107All as per item No107 above but of capacity 40W
108M&L for submain wiring with two runs of PVC insulated, unsheathed FRLSH cable with multistranded copper conductor,1100 volt grade of size 2.5 sqmm, including one run of FRLSH grade 2.5 sqmm PVC insulated, stranded, copper conductor cable as earth wire drawn in and including flameproof ERW stove enamelled steel rigid of suitable dia with bend, elbow, couplings, GI saddle clips etc and connecting up complete including taking down old unserviceable submain wiring complete all as specified and directed by Engr-In-Charge(Note: Two runs of 2.5 sqmm wire and one run 2.5 sqmm FRLSH PVC cable and one run of suitable size ERW steel conduit shall be measured as one length)
109All as per item No.109 above but of size 4.0sqmm
110M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate), 50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. (Note : GI strip upto 7.5 m length shall be deemed to include in the cost of above item.
111All as per item No 111 above but using galvanised earthing lead strip of size 32mm x 6mm complete including taking out old unserviceable earthing matrials all as specified and directed by Engr-in-Charge
112All as per item No 111 above but using copper plate 60cm x 60cm x 3,15mm thick electrode and 20 x 3mm copper strip as earthing lead complete including taking out old unserviceable earthing matrials all as specified and directed by Engr-in-Charge
113M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised iron strip of 25 x 4mm complete including taking down old unserviceable strip all as specified and directed
114All as per item No 114 above but GI strip 32 x 6mm all complete including taking down old unserviceable strip as specified and directed
115All as per item No 114 above but copper strip 20 x 3mm complete including taking down old unserviceable strip all as specified and directed
116Supply and fixing of single pointed air terminal Aluminum rod of 12mm dia and 300mm long.
117S & F aluminium strip 25x3.15mm with saddle and fixing screws for roof conductors and down conductors above ground.
118S & F but brass, size of spring hinge in 100 mm with phosphor bronze wire spring, bright polished complete all as specified and directed by Engr-In-Charge Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56995231
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 27-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs To Domestic Air Conditioners,Water Cooler,Refrigerator And Voltage Stabilizers At Itr Technical Area, Otm Bldgs Under Age E/M Chandipur And Repair/Repalcement Of Certain Flame Proof Sub-Main And Point Wiring, Dbs And Mccbs/Mcbs, Flame Proof Fittings, Lightning Protection System,Earthing And Allied Works At Itr And Lcs Area Under Age E/M Chandipur
Basic Detail
Tender No 8284/A/E8
Bidding Type Tender
Location
City Baleshwar
State Odisha
Key Dates
Publish Date 13 Aug 2026
Submission Date 27 Aug 2026
Open Date 03 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 69200
Exemption Available
Document List
b220e2b9-e3d7-4915-890a-c360f32cb80b.html
BOQ_878839.xls
Credit8284A.pdf
Tender8284A.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

b220e2b9-e3d7-4915-890a-c360f32cb80b.html

xls

BOQ_878839.xls

pdf

Credit8284A.pdf

pdf

Tender8284A.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders