Tender For maintenance of Various Colonies Under Nazul Account-Ii Dwarka Zone\. Sh:- Running, Maintenance & Operation Of Lifts, Fire Detection System, Fire Fighting System, Fire & Clear Water Pumps, Iei, D.G. Set And Other E/M Installations At Commun
Tender Overview
Project Description
Tender for maintenance of Various Colonies Under Nazul Account-Ii Dwarka Zone\. Sh:- Running, Maintenance & Operation Of Lifts, Fire Detection System, Fire Fighting System, Fire & Clear Water Pumps, Iei, D.G. Set And Other E/M Installations At Community Halls Of Village Pochanpur Adjoining Sector-23 And Dhulsiras Village Sector 24 Dwarka. Maintenance And Operation Of Iei, Compound Light Of Community Halls At Sec-19B, Amberi Village, Sector-8, Sector-16 Dwarka.
BOQ
| Sl. No. | Item Description |
| 1 | Running Maintenance and operation of IEI, Compound Light, D.G Set, Firefighting Pump set, fire alarm system, ventilation system,Clear water pump set, & lift at community hall pochanpur village sector-23 Dwarka.i) operator-1 nos |
| 2 | ii) khallasi-1 nos |
| 3 | iii)wireman |
| 4 | Running Maintenance and operation of IEI, Compound Light, Firefighting Pump set, fire alarm system, Clear water pump set, & lift at Community hall Dhulsiras village sector-24 Dwarka.i) operator-1 nos |
| 5 | ii) khallasi-1 nos |
| 6 | iii)wireman |
| 7 | Maintenance and operation of IEI, Compound Light at old community halls sec-16 , sec-8,sec-19B & amberai village Dwarka.i) wireman |
| 8 | ii) khallasi-1 nos |
| 9 | Supplying of 1.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 10 | Supplying of 4.0 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 11 | Supplying, of LED surface mounted Batten light of following body material and construction as per IS : 10322 withdriver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KVwith Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating andFixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C)Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) 18- 22 Watt |
| 12 | Supply of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 13 | Supplying and replacement 1200 mm sweep size ceeling fan i/c connection , testing etc as required |
| 14 | Supplying and replacement 300 mm sweep size exhaust fan i/c connection , testing etc as required |
| 15 | Replacement of 2.5/3.5 mfd fan condensor including connection and testing as required |
| 16 | Repair and rewinding of 1200/1400mm ceiling fan ( copper winding ) i/c varishing, testing and installation |
| 17 | Replacement of ball bearing of ceiling fans including fixing and testing etc |
| 18 | Replacement of ball bush of ceiling fans including fixing & testing etc |
| 19 | Providing 4 pole MCCB,250A, 36kAOperational Voltage 690V Ics=100% Icu i/c connection, testing, commissioning, etc. complete as required |
| 20 | b) 125 A,30KA,FPMCCB (Ics=Icu) i/cconnection, testing, commissioning, etc. complete as required |
| 21 | Supplying 6 A, to 32 A, ratings, SP MCB, \\"C\\" curve, 10 KAbreaking capacity i/c connections, testing and commissioning etc. as required. |
| 22 | Supplying 6 A, to 32 A, ratings, DP MCB, \\"C\\" curve, 10 KAbreaking capacity i/c connections, testing and commissioning etc. as required. |
| 23 | Supplying and Replacement following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 amps switch |
| 24 | b) 3 pin 5/6 A socket outlet |
| 25 | c) 15/16 A switch |
| 26 | d) 6 pin 15/16 A socket outlet |
| 27 | Supplying, of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).i/c testing & commissioning 40 watt |
| 28 | Supplying of following sizes of PVC insulated and PVC sheathed/XLPE a1uminium conductor cable of 1.1KV grade as required 2 X16 Sq.mm . |
| 29 | Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METALpipe as required. Upto 35 sq. mm |
| 30 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mmdia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 31 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 32 | Providing and fixing 6 SWG dia G.I. wire on surfaceor in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 33 | Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation, sand cushioning, protective covering and refilling thetrench etc as required. Upto 35 sq. mm |
| 34 | Servicing of 82.5 KVA D.G. set (Kirloskar make) i/c S/R of following parts/accessories, cartage testing on load etc complete as reqd. i) Oil filter --- 1 No.ii) Diesel filter (pre-micro)--- 1 setiii) Air cleaner elements --- 1 No.iv) K-cool superplus- 50-50 premix ---- 15 ltr.v) K-oil premix --- 13ltr,vi) Labour charges for servicing, functioning and testing--- 1 jobvii) Radiator cleaning charges --- 1 job i/c removal & refixing Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender