Housing Urban and Rular Development Local Bodies Closing in 5 days TDR #56995162

Tender For maintenance of Various Colonies Under Nazul Account-Ii Dwarka Zone\. Sh:- Running, Maintenance & Operation Of Lifts, Fire Detection System, Fire Fighting System, Fire & Clear Water Pumps, Iei, D.G. Set And Other E/M Installations At Commun

Issued by Local Bodies · Delhi, Delhi
Tender Value
28.37 Lakhs
Estimated cost
Bid Submission
20 Aug 2026
5 days left
EMD
56749
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for maintenance of Various Colonies Under Nazul Account-Ii Dwarka Zone\. Sh:- Running, Maintenance & Operation Of Lifts, Fire Detection System, Fire Fighting System, Fire & Clear Water Pumps, Iei, D.G. Set And Other E/M Installations At Community Halls Of Village Pochanpur Adjoining Sector-23 And Dhulsiras Village Sector 24 Dwarka. Maintenance And Operation Of Iei, Compound Light Of Community Halls At Sec-19B, Amberi Village, Sector-8, Sector-16 Dwarka.

BOQ

Name of Work:- M/o various colonies under Nazul Account-II Dwarka Zone\. SH:- Running, Maintenance & operation of Lifts, Fire Detection system, fire fighting system, fire & clear water Pumps, IEI, D.G. Set and other E/M installations at community halls of village pochanpur adjoining sector-23 and dhulsiras village sector 24 Dwarka. Maintenance and operation of IEI, Compound Light of community halls at sec-19B, Amberi village, sector-8, sector-16 Dwarka.
Sl. No. Item Description
1Running Maintenance and operation of IEI, Compound Light, D.G Set, Firefighting Pump set, fire alarm system, ventilation system,Clear water pump set, & lift at community hall pochanpur village sector-23 Dwarka.i) operator-1 nos
2ii) khallasi-1 nos
3iii)wireman
4Running Maintenance and operation of IEI, Compound Light, Firefighting Pump set, fire alarm system, Clear water pump set, & lift at Community hall Dhulsiras village sector-24 Dwarka.i) operator-1 nos
5ii) khallasi-1 nos
6iii)wireman
7Maintenance and operation of IEI, Compound Light at old community halls sec-16 , sec-8,sec-19B & amberai village Dwarka.i) wireman
8ii) khallasi-1 nos
9Supplying of 1.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable
10Supplying of 4.0 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable
11Supplying, of LED surface mounted Batten light of following body material and construction as per IS : 10322 withdriver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KVwith Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating andFixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C)Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) 18- 22 Watt
12Supply of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
13Supplying and replacement 1200 mm sweep size ceeling fan i/c connection , testing etc as required
14Supplying and replacement 300 mm sweep size exhaust fan i/c connection , testing etc as required
15Replacement of 2.5/3.5 mfd fan condensor including connection and testing as required
16Repair and rewinding of 1200/1400mm ceiling fan ( copper winding ) i/c varishing, testing and installation
17Replacement of ball bearing of ceiling fans including fixing and testing etc
18Replacement of ball bush of ceiling fans including fixing & testing etc
19Providing 4 pole MCCB,250A, 36kAOperational Voltage 690V Ics=100% Icu i/c connection, testing, commissioning, etc. complete as required
20b) 125 A,30KA,FPMCCB (Ics=Icu) i/cconnection, testing, commissioning, etc. complete as required
21Supplying 6 A, to 32 A, ratings, SP MCB, \\"C\\" curve, 10 KAbreaking capacity i/c connections, testing and commissioning etc. as required.
22Supplying 6 A, to 32 A, ratings, DP MCB, \\"C\\" curve, 10 KAbreaking capacity i/c connections, testing and commissioning etc. as required.
23Supplying and Replacement following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 amps switch
24b) 3 pin 5/6 A socket outlet
25c) 15/16 A switch
26d) 6 pin 15/16 A socket outlet
27Supplying, of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).i/c testing & commissioning 40 watt
28Supplying of following sizes of PVC insulated and PVC sheathed/XLPE a1uminium conductor cable of 1.1KV grade as required 2 X16 Sq.mm .
29Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METALpipe as required. Upto 35 sq. mm
30Earthing with G.I. earth pipe 4.5 Meter long, 40 mmdia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
31Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
32Providing and fixing 6 SWG dia G.I. wire on surfaceor in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
33Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation, sand cushioning, protective covering and refilling thetrench etc as required. Upto 35 sq. mm
34Servicing of 82.5 KVA D.G. set (Kirloskar make) i/c S/R of following parts/accessories, cartage testing on load etc complete as reqd. i) Oil filter --- 1 No.ii) Diesel filter (pre-micro)--- 1 setiii) Air cleaner elements --- 1 No.iv) K-cool superplus- 50-50 premix ---- 15 ltr.v) K-oil premix --- 13ltr,vi) Labour charges for servicing, functioning and testing--- 1 jobvii) Radiator cleaning charges --- 1 job i/c removal & refixing Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56995162
AUTHORITY Local Bodies
TENDER VALUE 28.37 Lakhs
LAST DATE 20-08-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for maintenance of Various Colonies Under Nazul Account-Ii Dwarka Zone\. Sh:- Running, Maintenance & Operation Of Lifts, Fire Detection System, Fire Fighting System, Fire & Clear Water Pumps, Iei, D.G. Set And Other E/M Installations At Community Halls Of Village Pochanpur Adjoining Sector-23 And Dhulsiras Village Sector 24 Dwarka. Maintenance And Operation Of Iei, Compound Light Of Community Halls At Sec-19B, Amberi Village, Sector-8, Sector-16 Dwarka.
Basic Detail
Tender No 17/EE/ELD-5/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 13 Aug 2026
Submission Date 20 Aug 2026
Open Date 21 Aug 2026
Finance
Tender Value 28.37 Lakhs
Tender Fee Ref. Documents
EMD 56749
Exemption Not Available
Document List
BOQ_968908.xls
ee7a23f7-9334-4e8c-91ab-28da4f7d786c.html
NIT17PDF.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_968908.xls

html

ee7a23f7-9334-4e8c-91ab-28da4f7d786c.html

pdf

NIT17PDF.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail