Tender For Supply And Commissioning Of Swas System - Analysers + S Le Handling System For Ntpc Talcher 2X660 Mw / Ntpc Lara 2 X 800 Mw / Ntpc Singrauli 2 X 800 Mw Projects
Tender Overview
Project Description
Tender for Supply And Commissioning Of Swas System - Analysers + S Le Handling System For Ntpc Talcher 2X660 Mw / Ntpc Lara 2 X 800 Mw / Ntpc Singrauli 2 X 800 Mw Projects , Primary Racks (With Ibr Certified Isolation Valves And Ibr Certified Ss316h Cooler Coils) Ntpc Talcher 2 X 660 Mw , Wet Panel - Enclosed Type Walkway Through Panel Ntpc Talcher 2 X 660 Mw , Dry Panel Ntpc Talcher 2 X 660 Mw , Chiller Unit - 2X100% Redundant - Min. 5 Tr Rating (With 25% Extra Capacity) Ntpc Talcher 2 X 660 Mw , Conductivity(Specific, Cation) Analyser - Single Channel Ntpc Talcher 2 X 660 Mw , Conductivity(Specific) Analyser For Hotwell - Single Channel Ntpc Talcher 2 X 660 Mw , Ph Analyser Transmitter- Single Channel Ntpc Talcher 2 X 660 Mw , Ph Analyser Sensor- Single Channel Ntpc Talcher 2 X 660 Mw , Dissolved Oxygen Analyser- Single Channel Ntpc Talcher 2 X 660 Mw , Dissolved Oxygen Sensor- Single Channel Ntpc Talcher 2 X 660 Mw , Sodium Analyser [Multi Channel(2 Channel)+1 Spare Channel] Ntpc Talcher 2 X 660 Mw , Silica Analyser [Multi Channel (4 Channel) +1 Spare Channel] Ntpc Talcher 2 X 660 Mw , Degassed Cation Conductivity Analyser Ntpc Talcher 2 X 660 Mw , Turbidity Analyser Single Channel Ntpc Talcher 2 X 660 Mw , Total Iron Analyser Single Channel Ntpc Talcher 2 X 660 Mw , Hydrazine Analyser - Single Channel Ntpc Talcher 2 X 660 Mw , Loose Supply Items As Per Annexure-A Ntpc Talcher 2 X 660 Mw , Mandatory Spares As Per Annexure- B - Shs Ntpc Talcher 2 X 660 Mw , Mandatory Spares As Per Annexure- B - Analysers Ntpc Talcher 2 X 660 Mw , Commissioning Spares- Reagents / Consumables / Calibratiors / Standard Solution As Required For Commissioning & Handing Over Of System To Owner Ntpc Talcher 2 X 660 Mw , Chemical Reagents, Consumables And Standard Solutions For 18 Months Of Operation Ntpc Talcher 2 X 660 Mw , Annunciator - Microprocessor Based Minimum 96 Points, Window Size : 70 Mm X 50 Mm Ntpc Talcher 2 X 660 Mw , O & M Manuals / Documentation Charges Ntpc Talcher 2 X 660 Mw , Supervision Of Erection, Total Commissioning And Handing Over Of Swas System Ntpc Talcher 2 X 660 Mw , Price For One Line Of High Pressure & High Temp. - Primary & Secondary Cooling To Be Considered Along With Other Instruments As Per P&Id Applicable For The Project. Ntpc Talcher 2 X 660 Mw , Price For One Line Of Low Pressure & Low Temp. - Secondary Cooling To Be Considered Along With Other Instruments As Per P&Id Applicable For The Project. Ntpc Talcher 2 X 660 Mw , Freight Charges For Ntpc Talcher 2 X 660 Mw (Lump Sum) , Primary Racks (With Ibr Certified Isolation Valves And Ibr Certified Ss316h Cooler Coils) Ntpc Lara 2 X 800 Mw , Wet Panel - Enclosed Type Walkway Through Panel Ntpc Lara 2 X 800 Mw , Dry Panel Ntpc Lara 2 X 800 Mw , Chiller Unit - 2X100% Redundant - Min. 5 Tr Rating (With 25% Extra Capacity) Ntpc Lara 2 X 800 Mw , Conductivity(Specific, Cation) Analyser - Single Channel Ntpc Lara 2 X 800 Mw , Conductivity(Specific) Analyser For Hotwell - Single Channel Ntpc Lara 2 X 800 Mw , Ph Analyser Transmitter- Single Channel Ntpc Lara 2 X 800 Mw , Ph Analyser Sensor- Single Channel Ntpc Lara 2 X 800 Mw , Dissolved Oxygen Analyser- Single Channel Ntpc Lara 2 X 800 Mw , Dissolved Oxygen Sensor- Single Channel Ntpc Lara 2 X 800 Mw , Sodium Analyser [Multi Channel(2 Channel)+1 Spare Channel] Ntpc Lara 2 X 800 Mw , Silica Analyser [Multi Channel (4 Channel) +1 Spare Channel] Ntpc Lara 2 X 800 Mw , Hydrogen Analyser - Single Channel Ntpc Lara 2 X 800 Mw , Degassed Cation Conductivity Analyser Ntpc Lara 2 X 800 Mw , Turbidity Analyser Single Channel Ntpc Lara 2 X 800 Mw , Total Iron Analyser Single Channel Ntpc Lara 2 X 800 Mw , Loose Supply Items As Per Annexure-A Ntpc Lara 2 X 800 Mw , Mandatory Spares As Per Annexure- B - Shs Ntpc Lara 2 X 800 Mw , Mandatory Spares As Per Annexure- B - Analysers Ntpc Lara 2 X 800 Mw , Commissioning Spares- Reagents / Consumables / Calibratiors / Standard Solution As Required For Commissioning & Handing Over Of System To Owner Ntpc Lara 2 X 800 Mw , Chemical Reagents, Consumables And Standard Solutions For 18 Months Of Operation Ntpc Lara 2 X 800 Mw , Annunciator - Microprocessor Based Minimum 96 Points, Window Size : 70 Mm X 50 Mm Ntpc Lara 2 X 800 Mw , O & M Manuals / Documentation Charges Ntpc Lara 2 X 800 Mw , Supervision Of Erection, Total Commissioning And Handing Over Of Swas System Ntpc Lara 2 X 800 Mw , Freight Charges For Ntpc Lara 2 X 800 Mw (Lump Sum) , Primary Racks (With Ibr Certified Isolation Valves And Ibr Certified Ss316h Cooler Coils) Ntpc Singrauli 2 X 800 Mw , Wet Panel - Enclosed Type Walkway Through Panel Ntpc Singrauli 2 X 800 Mw , Dry Panel Ntpc Singrauli 2 X 800 Mw , Chiller Unit - 2X100% Redundant - Min. 5 Tr Rating (With 25% Extra Capacity) Ntpc Singrauli 2 X 800 Mw , Conductivity(Specific, Cation) Analyser - Single Channel Ntpc Singrauli 2 X 800 Mw , Conductivity(Specific) Analyser For Hotwell - Single Channel Ntpc Singrauli 2 X 800 Mw , Ph Analyser Transmitter- Single Channel Ntpc Singrauli 2 X 800 Mw , Ph Analyser Sensor- Single Channel Ntpc Singrauli 2 X 800 Mw , Dissolved Oxygen Analyser- Single Channel Ntpc Singrauli 2 X 800 Mw , Dissolved Oxygen Sensor- Single Channel Ntpc Singrauli 2 X 800 Mw , Sodium Analyser [Multi Channel(2 Channel)+1 Spare Channel] Ntpc Singrauli 2 X 800 Mw , Silica Analyser [Multi Channel (4 Channel) +1 Spare Channel] Ntpc Singrauli 2 X 800 Mw , Hydrogen Analyser - Single Channel Ntpc Singrauli 2 X 800 Mw , Degassed Cation Conductivity Analyser Ntpc Singrauli 2 X 800 Mw , Turbidity Analyser Single Channel Ntpc Singrauli 2 X 800 Mw , Total Iron Analyser Single Channel Ntpc Singrauli 2 X 800 Mw , Loose Supply Items As Per Annexure-A Ntpc Singrauli 2 X 800 Mw , Mandatory Spares As Per Annexure- B - Shs Ntpc Singrauli 2 X 800 Mw , Mandatory Spares As Per Annexure- B - Analysers Ntpc Singrauli 2 X 800 Mw , Commissioning Spares- Reagents / Consumables / Calibratiors / Standard Solution As Required For Commissioning & Handing Over Of System To Owner Ntpc Singrauli 2 X 800 Mw , Chemical Reagents, Consumables And Standard Solutions For 18 Months Of Operation Ntpc Singrauli 2 X 800 Mw , Annunciator - Microprocessor Based Minimum 96 Points, Window Size : 70 Mm X 50 Mm Ntpc Singrauli 2 X 800 Mw , O & M Manuals / Documentation Charges Ntpc Singrauli 2 X 800 Mw , Supervision Of Erection, Total Commissioning And Handing Over Of Swas System Ntpc Singrauli 2 X 800 Mw , Freight Charges For Ntpc Singrauli 2 X 800 Mw (Lump Sum)
BOQ
| Sl. No. | Item Description |
| 1 | PRIMARY RACKS (With IBR certified Isolation Valves and IBR Certified SS316H Cooler Coils)NTPC TALCHER 2 x 660 MW |
| 2 | WET PANEL - ENCLOSED TYPE WALKWAY THROUGH PANELNTPC TALCHER 2 x 660 MW |
| 3 | DRY PANELNTPC TALCHER 2 x 660 MW |
| 4 | CHILLER UNIT - 2x100% REDUNDANT - Min. 5 TR rating (With 25% extra Capacity)NTPC TALCHER 2 x 660 MW |
| 5 | CONDUCTIVITY(SPECIFIC, CATION) ANALYSER - SINGLE CHANNELNTPC TALCHER 2 x 660 MW |
| 6 | CONDUCTIVITY(SPECIFIC) ANALYSER FOR HOTWELL - SINGLE CHANNELNTPC TALCHER 2 x 660 MW |
| 7 | pH ANALYSER TRANSMITTER- SINGLE CHANNELNTPC TALCHER 2 x 660 MW |
| 8 | pH ANALYSER SENSOR- SINGLE CHANNELNTPC TALCHER 2 x 660 MW |
| 9 | DISSOLVED OXYGEN ANALYSER- SINGLE CHANNELNTPC TALCHER 2 x 660 MW |
| 10 | DISSOLVED OXYGEN SENSOR- SINGLE CHANNELNTPC TALCHER 2 x 660 MW |
| 11 | SODIUM ANALYSER [MULTI CHANNEL(2 CHANNEL)+1 SPARE CHANNEL]NTPC TALCHER 2 x 660 MW |
| 12 | SILICA ANALYSER [MULTI CHANNEL (4 CHANNEL) +1 SPARE CHANNEL]NTPC TALCHER 2 x 660 MW |
| 13 | DEGASSED CATION CONDUCTIVITY ANALYSERNTPC TALCHER 2 x 660 MW |
| 14 | TURBIDITY ANALYSER SINGLE CHANNELNTPC TALCHER 2 x 660 MW |
| 15 | TOTAL IRON ANALYSER SINGLE CHANNELNTPC TALCHER 2 x 660 MW |
| 16 | HYDRAZINE ANALYSER - SINGLE CHANNELNTPC TALCHER 2 x 660 MW |
| 17 | LOOSE SUPPLY ITEMS AS PER ANNEXURE-ANTPC TALCHER 2 x 660 MW |
| 18 | Mandatory Spares as per Annexure- B - SHSNTPC TALCHER 2 x 660 MW |
| 19 | Mandatory Spares as per Annexure- B - AnalysersNTPC TALCHER 2 x 660 MW |
| 20 | COMMISSIONING SPARES- Reagents / Consumables / Calibratiors / Standard Solution as required for commissioning & Handing over of System to OwnerNTPC TALCHER 2 x 660 MW |
| 21 | CHEMICAL REAGENTS, CONSUMABLES AND STANDARD SOLUTIONS FOR 18 MONTHS OF OPERATIONNTPC TALCHER 2 x 660 MW |
| 22 | ANNUNCIATOR - Microprocessor based Minimum 96 Points, Window size : 70 mm x 50 mmNTPC TALCHER 2 x 660 MW |
| 23 | O & M MANUALS / DOCUMENTATION CHARGESNTPC TALCHER 2 x 660 MW |
| 24 | SUPERVISION OF ERECTION, TOTAL COMMISSIONING AND HANDING OVER OF SWAS SYSTEMNTPC TALCHER 2 x 660 MW |
| 25 | Price for one line of High Pressure & High Temp. - Primary & Secondary cooling to be considered along with other instruments as per P&ID applicable for the project.NTPC TALCHER 2 x 660 MW |
| 26 | Price for one line of Low Pressure & Low Temp. - Secondary cooling to be considered along with other instruments as per P&ID applicable for the project.NTPC TALCHER 2 x 660 MW |
| 27 | Freight Charges for NTPC Talcher 2 X 660 MW (LUMP SUM) |
| 28 | PRIMARY RACKS (With IBR certified Isolation Valves and IBR Certified SS316H Cooler Coils)NTPC Lara 2 X 800 MW |
| 29 | WET PANEL - ENCLOSED TYPE WALKWAY THROUGH PANELNTPC Lara 2 X 800 MW |
| 30 | DRY PANELNTPC Lara 2 X 800 MW |
| 31 | CHILLER UNIT - 2x100% REDUNDANT - Min. 5 TR rating (With 25% extra Capacity)NTPC Lara 2 X 800 MW |
| 32 | CONDUCTIVITY(SPECIFIC, CATION) ANALYSER - SINGLE CHANNELNTPC Lara 2 X 800 MW |
| 33 | CONDUCTIVITY(SPECIFIC) ANALYSER FOR HOTWELL - SINGLE CHANNELNTPC Lara 2 X 800 MW |
| 34 | pH ANALYSER TRANSMITTER- SINGLE CHANNELNTPC Lara 2 X 800 MW |
| 35 | pH ANALYSER SENSOR- SINGLE CHANNELNTPC Lara 2 X 800 MW |
| 36 | DISSOLVED OXYGEN ANALYSER- SINGLE CHANNELNTPC Lara 2 X 800 MW |
| 37 | DISSOLVED OXYGEN SENSOR- SINGLE CHANNELNTPC Lara 2 X 800 MW |
| 38 | SODIUM ANALYSER [MULTI CHANNEL(2 CHANNEL)+1 SPARE CHANNEL]NTPC Lara 2 X 800 MW |
| 39 | SILICA ANALYSER [MULTI CHANNEL (4 CHANNEL) +1 SPARE CHANNEL]NTPC Lara 2 X 800 MW |
| 40 | HYDROGEN ANALYSER - SINGLE CHANNELNTPC Lara 2 X 800 MW |
| 41 | DEGASSED CATION CONDUCTIVITY ANALYSERNTPC Lara 2 X 800 MW |
| 42 | TURBIDITY ANALYSER SINGLE CHANNELNTPC Lara 2 X 800 MW |
| 43 | TOTAL IRON ANALYSER SINGLE CHANNELNTPC Lara 2 X 800 MW |
| 44 | LOOSE SUPPLY ITEMS AS PER ANNEXURE-ANTPC Lara 2 X 800 MW |
| 45 | Mandatory Spares as per Annexure- B - SHSNTPC Lara 2 X 800 MW |
| 46 | Mandatory Spares as per Annexure- B - AnalysersNTPC Lara 2 X 800 MW |
| 47 | COMMISSIONING SPARES- Reagents / Consumables / Calibratiors / Standard Solution as required for commissioning & Handing over of System to Owner NTPC Lara 2 X 800 MW |
| 48 | CHEMICAL REAGENTS, CONSUMABLES AND STANDARD SOLUTIONS FOR 18 MONTHS OF OPERATIONNTPC Lara 2 X 800 MW |
| 49 | ANNUNCIATOR - Microprocessor based Minimum 96 Points, Window size : 70 mm x 50 mmNTPC Lara 2 X 800 MW |
| 50 | O & M MANUALS / DOCUMENTATION CHARGESNTPC Lara 2 X 800 MW |
| 51 | SUPERVISION OF ERECTION, TOTAL COMMISSIONING AND HANDING OVER OF SWAS SYSTEMNTPC Lara 2 X 800 MW |
| 52 | Freight Charges for NTPC Lara 2 X 800 MW (LUMP SUM) |
| 53 | PRIMARY RACKS (With IBR certified Isolation Valves and IBR Certified SS316H Cooler Coils)NTPC Singrauli 2 X 800 MW |
| 54 | WET PANEL - ENCLOSED TYPE WALKWAY THROUGH PANELNTPC Singrauli 2 X 800 MW |
| 55 | DRY PANELNTPC Singrauli 2 X 800 MW |
| 56 | CHILLER UNIT - 2x100% REDUNDANT - Min. 5 TR rating (With 25% extra Capacity)NTPC Singrauli 2 X 800 MW |
| 57 | CONDUCTIVITY(SPECIFIC, CATION) ANALYSER - SINGLE CHANNELNTPC Singrauli 2 X 800 MW |
| 58 | CONDUCTIVITY(SPECIFIC) ANALYSER FOR HOTWELL - SINGLE CHANNELNTPC Singrauli 2 X 800 MW |
| 59 | pH ANALYSER TRANSMITTER- SINGLE CHANNELNTPC Singrauli 2 X 800 MW |
| 60 | pH ANALYSER SENSOR- SINGLE CHANNELNTPC Singrauli 2 X 800 MW |
| 61 | DISSOLVED OXYGEN ANALYSER- SINGLE CHANNELNTPC Singrauli 2 X 800 MW |
| 62 | DISSOLVED OXYGEN SENSOR- SINGLE CHANNELNTPC Singrauli 2 X 800 MW |
| 63 | SODIUM ANALYSER [MULTI CHANNEL(2 CHANNEL)+1 SPARE CHANNEL]NTPC Singrauli 2 X 800 MW |
| 64 | SILICA ANALYSER [MULTI CHANNEL (4 CHANNEL) +1 SPARE CHANNEL]NTPC Singrauli 2 X 800 MW |
| 65 | HYDROGEN ANALYSER - SINGLE CHANNELNTPC Singrauli 2 X 800 MW |
| 66 | DEGASSED CATION CONDUCTIVITY ANALYSERNTPC Singrauli 2 X 800 MW |
| 67 | TURBIDITY ANALYSER SINGLE CHANNELNTPC Singrauli 2 X 800 MW |
| 68 | TOTAL IRON ANALYSER SINGLE CHANNELNTPC Singrauli 2 X 800 MW |
| 69 | LOOSE SUPPLY ITEMS AS PER ANNEXURE-ANTPC Singrauli 2 X 800 MW |
| 70 | Mandatory Spares as per Annexure- B - SHSNTPC Singrauli 2 X 800 MW |
| 71 | Mandatory Spares as per Annexure- B - AnalysersNTPC Singrauli 2 X 800 MW |
| 72 | COMMISSIONING SPARES- Reagents / Consumables / Calibratiors / Standard Solution as required for commissioning & Handing over of System to OwnerNTPC Singrauli 2 X 800 MW |
| 73 | CHEMICAL REAGENTS, CONSUMABLES AND STANDARD SOLUTIONS FOR 18 MONTHS OF OPERATIONNTPC Singrauli 2 X 800 MW |
| 74 | ANNUNCIATOR - Microprocessor based Minimum 96 Points, Window size : 70 mm x 50 mmNTPC Singrauli 2 X 800 MW |
| 75 | O & M MANUALS / DOCUMENTATION CHARGESNTPC Singrauli 2 X 800 MW |
| 76 | SUPERVISION OF ERECTION, TOTAL COMMISSIONING AND HANDING OVER OF SWAS SYSTEM NTPC Singrauli 2 X 800 MW |
| 77 | Freight Charges for NTPC Singrauli 2 X 800 MW (LUMP SUM) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender