Tender for Restoration Of Street Lights At Aa-Iic, Iid & Iie At Aa-Ii, New Town, Kolkata Under Nkda , Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitary) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 150Watt , Supply & Delivery Xlpe Armoured Aluminum Cable 4 X 16Sqmm, Make- Havells/ Polycab/ Gloster/ repair renovation Kabel/ Mescab , Supply & Delivery Pvc Insulated Flexible Cu Cable 3C X 1.5Sqmm, Make- Havells/ Polycab/ Gloster/ repair renovation Kabel/ Mescab , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required.Upto 35 Sq. Mm , Supplying And Making Straight Through Joint With Cast Resin Compound Including Ferrules And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 4 X 16 Sq. Mm , Finishing The End Of Following Xlpe/Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket (Dowels Make), Tapes, Anticorrosive Paste & Jointing Materials : 4 Core 16 Sqmm Cable , Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Colour Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output. Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 200Watt
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 150Watt |
| 2 | Supply & Delivery XLPE Armoured Aluminum Cable 4 X 16Sqmm, Make- Havells/ Polycab/ Gloster/ RR Kabel/ Mescab |
| 3 | Supply & Delivery PVC insulated Flexible Cu Cable 3C X 1.5Sqmm, Make- Havells/ Polycab/ Gloster/ RR Kabel/ Mescab |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 5 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm |
| 6 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 core 16 sqmm cable |
| 7 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 200Watt Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender