Housing Urban and Rular Development Local Bodies Closing in 12 days TDR #56992486

Tender For Restoration Of Street Lights At Aa-Iic, Iid & Iie At Aa-Ii, New Town, Kolkata Under Nkda

Issued by Local Bodies · 24 Paraganas North, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Aug 2026
12 days left
EMD
42000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Restoration Of Street Lights At Aa-Iic, Iid & Iie At Aa-Ii, New Town, Kolkata Under Nkda , Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitary) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 150Watt , Supply & Delivery Xlpe Armoured Aluminum Cable 4 X 16Sqmm, Make- Havells/ Polycab/ Gloster/ repair renovation Kabel/ Mescab , Supply & Delivery Pvc Insulated Flexible Cu Cable 3C X 1.5Sqmm, Make- Havells/ Polycab/ Gloster/ repair renovation Kabel/ Mescab , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required.Upto 35 Sq. Mm , Supplying And Making Straight Through Joint With Cast Resin Compound Including Ferrules And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 4 X 16 Sq. Mm , Finishing The End Of Following Xlpe/Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket (Dowels Make), Tapes, Anticorrosive Paste & Jointing Materials : 4 Core 16 Sqmm Cable , Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Colour Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output. Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 200Watt

BOQ

Name of Work:- Restoration of Street Lights at AA-IIC, IID & IIE at AA-II, New Town, Kolkata under NKDA
Sl. No. Item Description
1Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 150Watt
2Supply & Delivery XLPE Armoured Aluminum Cable 4 X 16Sqmm, Make- Havells/ Polycab/ Gloster/ RR Kabel/ Mescab
3Supply & Delivery PVC insulated Flexible Cu Cable 3C X 1.5Sqmm, Make- Havells/ Polycab/ Gloster/ RR Kabel/ Mescab
4Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
5Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm
6Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 core 16 sqmm cable
7Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 200Watt Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56992486
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 29-08-2026
Authority
Authority Name New Town Kolkata Development Authority
Work Description Tender for Restoration Of Street Lights At Aa-Iic, Iid & Iie At Aa-Ii, New Town, Kolkata Under Nkda , Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitary) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 150Watt , Supply & Delivery Xlpe Armoured Aluminum Cable 4 X 16Sqmm, Make- Havells/ Polycab/ Gloster/ repair renovation Kabel/ Mescab , Supply & Delivery Pvc Insulated Flexible Cu Cable 3C X 1.5Sqmm, Make- Havells/ Polycab/ Gloster/ repair renovation Kabel/ Mescab , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required.Upto 35 Sq. Mm , Supplying And Making Straight Through Joint With Cast Resin Compound Including Ferrules And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 4 X 16 Sq. Mm , Finishing The End Of Following Xlpe/Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket (Dowels Make), Tapes, Anticorrosive Paste & Jointing Materials : 4 Core 16 Sqmm Cable , Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Colour Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 135 Lm/Watt Output. Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 200Watt
Basic Detail
Tender No NOTICE INVITING e-Quotation No. WBNKDA/11/EE-E/ 2026-27
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 13 Aug 2026
Submission Date 29 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 42000
Exemption Not Available
Document List
245106fd-20e1-480f-aa5f-3d7109f3ee41.html
BOQ_2549658.xls
Tendernotice_1 (19).pdf
Tendernotice_11AA2A.pdf
WBF2911.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

245106fd-20e1-480f-aa5f-3d7109f3ee41.html

xls

BOQ_2549658.xls

pdf

Tendernotice_1 (19).pdf

pdf

Tendernotice_11AA2A.pdf

pdf

WBF2911.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders