Tender For Repair/Replacement Of Ht Cable Network, Distribution Transformers, Vcbs Overhead Ht Structures And Earthing At Pxe Tech And Residential Area At Pxe Chandipur.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Sep 2026
18 days left
EMD
79600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baleshwar → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Ht Cable Network, Distribution Transformers, Vcbs Overhead Ht Structures And Earthing At Pxe Tech And Residential Area At Pxe Chandipur.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (I) R&D CHANDIPUR Name of Work: REPAIR/REPLACEMENT OF HT CABLE NETWORK, DISTRIBUTION TRANSFORMERS, VCB's OVERHEAD HT STRUCTURES AND EARTHING AT PXE TECH AND RESIDENTIAL AREA AT PXE CHANDIPUR. Contract No: GE(I)R&D/BLS/ 2026-27 Bidder Name : SCHEDULE 'A' (BOQ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Work / Item Item Code / Make Number or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE (including all Taxes as specified in tender Documents) In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Disconnecting the transformer indoor /out door from HT / LT side at site dismantling carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strip and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, inspection of core, supply and replacing 5 mm thick rubberised cork sheet gasket for tank top cover and replacement of gaskets/oil seal of HT/LT side to arrest the leakage of transformer oil complete reassembling the complete dismantled items, reconnecting the HT/ LT supply cable ends at the site for the following transformer complete all as directed by Engineer-in-charge.: (a)Transformer capacity 125 KVA to 250 KVA |
| 3 | All as per item No 1 above but Transformer of capacity 300KVA to 400 KVA |
| 4 | All as per item No 1 above but Transformer of capacity 500KVA to 630 KVA |
| 5 | M&L for lightning arresters suitable voltage 11000 volts expulsion type complete with all fittings, transmission class,discharge capacity 65 kilo amp ncluding installation testing and commissoning as per site requirement complete all as specified and directed by Engr-in-charge . |
| 6 | Supply and Fixing Microprocessor Numerical 3-Over Current & 1Earth fault Protection Relay with high Set Instantaneous unit with in-built Trip Circuit Supervision Type - ADR141C including necessary connection, initial calibration and testing complete all as directed by Engineer-in-Charge. |
| 7 | M&L for Filtration and Dehydration of transformer oil of Transformers / OCBs / Oil switches at different location of ITR Chandipur with filtration cum dehydration machine to achieve desired level of di electric strength of transformer oil including testing complete as specified and all as directed by engineer in charge.Note- The quoted rate is deemed to be included cost of centrifuging the transformer oil by means of electrical operated centrifuging machine .(ii) The contrator shall test the di electric strength of oil of each transformer before dehydration & filtration and after completion of dehydration and filtration process and submit record of the same. Each sample of oil shall be tested with a transformer oil test machine at site in presence of concerned JE/ Engr- in- Charge. The contractor will have to arrange correctly calibrated Transformer Oil Test machine. for this purpose and quoted rate is deemed to be included for this account . (iii) Old unserviceable oil obtained if any shall be deposited in the MES store complete all as directed by Engr- in- Charge . |
| 8 | Supply only insulation oil in Transformer Oil tank having Di-electric strength not less than 60 KV at 2.5 mm electrode gap for 60 sec confirming to IS-335 and ISI marked all as spsecified and directed by Engineer-in-Charge. |
| 9 | Supply and filling in repair/replacement of silica gel in existing breather assembly complete all as directed by Engineer-in-charge. |
| 10 | Supply & fixing in repair/replacement of breather for 400/500 KVA Transformer complete all as directed by Engineer-in-charge. |
| 11 | Supply & fixing in repair/replacement of breather for 200/250 KVA Transformer |
| 12 | S/F in replacement of HT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for (11/0.433 KV) 50 KVA TO 630 KVA Transformer complete in all respect & all specified. |
| 13 | S&F in replacement of .LT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for 50 KVA TO 300 KVA Transformer complete in all respect & all specified. |
| 14 | Supply and fix Temperature gauge suitable for transformer of capacity above 100 KVA and upto 400 KVA complete all as specified and as directed. |
| 15 | All as per item No. 11 but suitable for transformer of capacity 500 KVA to 630 KVA |
| 16 | Dismantling the Transformer of 63 to 630 KVA, 11/0.415 KVA capacity and transporting the Transformer from Sub station to workshop and draining out oil and storing aside lifting of core and winding assembly, further dismantling and segregation of HT/LT serviceable and unserviceable winding, taking out old worn out insulator, separators set for strip, inspection and further necessary repair and carrying out cleaning of complete transformer, removing of all worn out gasket/Jointing materials, oil seals. Segregation of all serviceable spares/ accessories/ components for reuse and replacement of unserviceable spares/accessories/ components with new materials and reassembling and transporting the transformer to sub stn after carrying out repair including dehydration and testing and commissioning complete all as specified and directed by Engineer-in-charge. |
| 17 | Materials for HT/LT winding of Transformer with super enameled copper wire/strip of appropriate cross section and turn as per existing complete all as directed by Engineer-in-charge.Note- 1.Transformer will be repaired only from OEM or authorised dealer of OEM 2. Quantity of super enamelled wire or strip as required will be considered as per OEM/dealers paid vouchar duly mentioned make,model machine No of transformer.3. Conntractor will deposit the same to Engr-in-chage before claiming any payment. |
| 18 | Materials for re-insulation by wrapping with new insulation paper after taking down old burnt insulation including assembly and connection for 200/250 KVA, 11/0.433 KV Transformer all as specified and directed by Engineer-in-charge. |
| 19 | Carrying out replacement of all Gasket using rubber cork sheet of 6.0 mm thick including providing gasket cement adhesive all as specified and directed by Engineer-in-charge. |
| 20 | Note for item No 16 :-(i) Cost of Supply and fixing of nuts, bolts, washers, fevicol, sleeves, cotton, tapes etc shall be deemed to be included in quoted rate. |
| 21 | M&L for taking proper shut down, disconnecting incoming / out going cable, control cable from 11 KV OCB/VCB of any type and capacity upto 630 amps and carrying out complete servicing / overhauling, resetting of all electrical and mechanical parts for easy and proper operation, greasing of moving / revolving / sliding parts in VCB Panel, calibration of relays, meters incl thorough cleanining with air blower / vacuum cleaner, decarbonising & providing mineral jelly to all arcing contacts of the VCB panel, and serviceability check from local / remote control panel including replacement of unserviceable minor spare parts viz. nut / bolt / washer / connecting wire / insulation tape / sleeves etc complete including reassembling complete parts reconnecting incoming / outgoing cable, testing on load complete all as directed by Engineer-in-charge. |
| 22 | Note- 1. Unserviceable items other than minor parts to be replaced will be meaured and paid seperately as supply only under revelent items in the schedule. However, cost of certain minor spares viz nut / bolt / washer / connecting wire / insulation tape / sleeves etc. if required shall deem to be included in the cost of repair of the item.2. The spare parts to be replaced shall be of reputed brand / make and shall be of same type, design, specifications etc to match with the existing parts.3. Complete servicing and calibration work shall be carried out by qualified and reputed service engineer as detailed by OEM /authorised dealer of OEM only. |
| 23 | Supply only of following items for maintenance of OCB/VCB of 11 KV, 400/630 Amps capacity complete all as directed by Engineer-in-charge.:- |
| 24 | Supply only Lower Spout suitable for existing parts at site. |
| 25 | Supply only Housing suitable for existing parts at site. |
| 26 | Supply only Drive Insulator suitable for existing parts at site. |
| 27 | Supply only Flower Contact suitable for existing parts at site. |
| 28 | Supply only LED Indicator Lamps RED 110V AC/DC suitable for existing parts at site. |
| 29 | Supply only LED Indicator Lamps Yellow 110V AC/DC suitable for existing parts at site. |
| 30 | Supply only LED Indicator Lamps Blue 110V AC/DC suitable for existing parts at site. |
| 31 | Supply only LED Indicator Lamps White 110V AC/DC suitable for existing parts at site. |
| 32 | Supply only PT Fuse 3.15A suitable for existing parts at site. |
| 33 | supply only Breaker Control Switch 25A suitable for existing parts at site. |
| 34 | Supply only Anti Condensation Space Heater suitable for existing parts at site. |
| 35 | supply only Fuse Holderwith Base- 32 amps suitable for existing parts at site. |
| 36 | Supply only Thermostat suitable for existing parts at site. |
| 37 | Supply only Spring Charging Motor Coil Voltage 230V,RPM 7000 suitable for existing parts at site. |
| 38 | Supply only 11 KV Insulator suitable for existing parts at site. |
| 39 | Supply only Master Trip relay, (Coil Voltage=110V DC) Contact Configuration 03 No+2NC (H/R) as Size 1/4 NV 10T suitable for existing parts at site. |
| 40 | Supply only vaccuum interrupter for 11 KV VCB suitable for existing parts at site. |
| 41 | Supply only Contactor Relay of 10A, 03 NO+01 NC , Size 0, Coil Voltage-230V AC, Type No-3TH30310AP0 suitable for existing parts at site. |
| 42 | Supply only 11 Kv Bus Bar Sleeves suitable for existing parts at site. |
| 43 | Supply only Busbar Spout for VCB suitable size for existing parts at site. |
| 44 | Supply only 1-Phase Digital Ammeter (96 Sqmm)-Flush Mounted, (C1:1/0), Aux/ Supply=110V AC suitable for existing parts at site. |
| 45 | Supply only 1-Phase Digital Voltmeter (96 Sqmm)-Flush Mounted, PT Ratio: 11Kv/3/110V/3 suitable for existing parts at site. |
| 46 | Supply only Digital Multi-function Meter (Aux.Supply=110V AC),CT Sec:1A, PT Sec=110V AC,Size:96mmX96mm,CI:1.0 suitable for existing parts at site. |
| 47 | Supply only Selector Switch for local& Remote 2 pole 2 way, Ampere 10A, colour Grey,Volt-220V AC/DCsuitable for existing parts at site. |
| 48 | Supply only Voltmeter Selector Switch (3-way and Off) R-Y,Y-B,B-R,Off suitable for existing parts at site. |
| 49 | Supply only Ammeter Selector Switch (3-way and Off) R-Y,Y-B,B-R,Off suitable for existing parts at site. |
| 50 | Supply only Spring return shrouded push Button with bracket colour (Green0 with 1-N/O for Trip Circuit Healthy Check suitable for existing parts at site. |
| 51 | Supply only Solid State Buzzer 3-Ton operating Multi-Voltage 12V to 240 AC/DC, Output 1W - 3W/90-120DB Range 50Meter Front Bezzel 96X96mm suitable for existing parts at site. |
| 52 | Supply only door limit switch with push rod only-1-N/O+1-N/C, 10A, 500V suitable for existing parts at site. |
| 53 | Supply only toggle Switch for Heater suitable for existing parts at site. |
| 54 | Supply only Copper Bus Bar 60X10Sqmm suitable for existing parts at site. (01 Kg) |
| 55 | Supply only 2.5Sqmm/1.5 Sqmm wire suitable for existing parts at site. |
| 56 | Supply only Service and Test Position Aux. Switch Suitable for existing parts at site. |
| 57 | Supply only 12 NO+12NC Aux. Switch Suitable for existing parts at site. |
| 58 | M & L in replacement of IDMT relay/CT/trip relay complete system serviceable complete testing of IDMT relay complete all as specified and directed by Engineer-in-charge. |
| 59 | Disconnecting and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of cast resin type 11 KV current transformer having ratio of 100+50/5+5A having protection core class 5P10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking cap of 13.1 KV for 1.0 second complete all as specified and directed by Engineer-in-charge. |
| 60 | Disconnecting and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of cast resin type 11 KV current transformer having ratio of 200+100/5+5A having protection core class 5P10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking cap of 13.1 KV for 1.0 second complete all as specified and directed by Engineer-in-charge. |
| 61 | Disconnecting and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of cast resin type 11 KV current transformer having ratio of 400+100/5+5A having protection core class 5P10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking cap of 13.1 KV for 1.0 second complete all as specified and directed by Engineer-in-charge. |
| 62 | Supplying and erection of channel iron 100 mm X 50 mm X 6 mm (9.56 kg per metre) V shape cross arm for two 33 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc and painting with primer and finish paint as required |
| 63 | Supply & fix jumper Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.binding wire including reconnecting all connections by means of suitable size lugs/thimbles including taking down old aluminium conductor jumper complete all as directed by Engr-in-Charge. |
| 64 | Supplying ,fixing danger notice board of 1.6 mm thick mild steel sheet , viterous enamelled white , with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps , bolts for HT 25X20 cm size complete all as specified and directed by Engineer-in-charge. |
| 65 | M & L for painting of two pole/four pole structur including cross arms,chanel etc complete structure after scraping and removing old paint completely and then applying two coats of aluminium paint over one coat of zinc oxide primer complete all as directed by Engr-in-Charge |
| 66 | M & L for painting of OCB's from inside and outside by applying two coats of synthetic enamel paint (Smoke grey) after scraping and removing old paint and writing SM/MES No., Incoming and outgoing details complete all as specified and directed by Engineer-in-charge. |
| 67 | M & L for calibration of earth fault relay ,and over load relay with accuracy of OCB/VCB and setting and testing the tripping system as directed by Engr-in-charge and servicing of OCB/VCB , cleaning the rust and dust of metal part and applying lubrication to all moving parts complete all as specified and directed by Engineer-in-charge. |
| 68 | M&L for painting with two coats of first quality synthetic enamail paint over a coat of red oxide primer after complete removal of existing finish to step up / step down transformer of capacity 50 to 500KVA complete all as specified and directed by Engineer-in-charge. .(Note: Proper shutdown including dismantling of primary / secondary connections and refixing the same to be ensured) |
| 69 | M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 80 mm & inner pipe dia 50 mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% burried in ground by digging a bore of 150 mm dia surrounded by soil friendly backfill compound non soluble in water including connection with galvanised earth strip 32 x 6 mm, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 8 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 1.0 ohm complete. (Note - GI strip size 32x6 mm upto 7.5 m included in the item). |
| 70 | Supply, fixing and testing dry type 11 KV/ 3/110V/ 3 potential transformer (PT) suitable for 11 KV , 3 phase , 50 Hz , class 1A, 50 VA complete suitable for VCB 11 KV including taking out old unserviceable PT any type complete all as specified and directed by Engineer-in-charge. |
| 71 | Supply and fixing Dew guard is a passive solution for mitigation of condensation of tempreture between -30 deg C + 90 deg C, it is halogen free and silicon free, environment friendly and can be disposed of in regular trash of size 150 x 250 x 2 mm including fixign arrangement with strong addishve double sided tap all as spd and directed by engrs in charge. |
| 72 | Power pack of suitable capacity contained maintenance free battery and charger to provide auxilary power supply to the VCB complete all as specified and directed by Engineer-in-charge. |
| 73 | Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres all as specified and directed by Engineer-in-charge. |
| 74 | Supply and laying connecting and testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cable with aluminium conductor 11000V grade cross sectional area 95 Sq mm 3 core complete all as specified and directed. |
| 75 | M&L GI pipe light grade with all fitting laid in trenches and under road/floor/culverts along with pole etc 80mm bore. |
| 76 | M & L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable size 95 sqmm complete all as specified and directed. |
| 77 | M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable size 95 sqmm complete all as specified and directed. |
| 78 | M & L for Cable jointing kit for 11 KV (Earthed) grade cable for Straight through joint heat shrink type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable size 95 sqmm complete all as specified and directed. |
| 79 | M&L for checking and finding pin point location of fault in HT 11 KV UG cable of any size with the help of fault locating mobile machine complete all as directed by Engr-In-Charge.Note : (i) Rate for rent of the fault locating mobile machine, charges for operator, engineer, electricians etc are deemed to be included in the quoted rate.(ii) Fault should be located and repaired within 12 hours |
| 80 | Supplying and erection of bow stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and also with 0.6 m long brace of size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulley fixed at one end of the brace as required. |
| 81 | Supplying and laying synthetic Rubber insulated mats of size 2mX 1mX2.5 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety all as specified and directed . |
| 82 | Supplying and laying synthetic insulating mat of size 2Mtr x 1 Mtr x 19 mm class B, dielectric strength 45KV, complete all as specified and directed |
| 83 | Supply and fixing Droup out Switch 11KV GOAB Switches (Two in One Unit) complete all as directed by Engineer-in-charge. |
| 84 | Supply, fixing , commissioning and testing in replacement of outdoor type , 11 KV polymer gang operated switch with drop out fuse assay complete of current rating upto 400 Amps 4 insulator Vertical type triple pole each pole consisting of galvanized steel based HT insulator as per IS non ferrous knife and spring loaded contacts, arching horns of adequate section to break magnetizing current of the transformers horizontol Gi of adequate length for phase separation , adequate length of GI pipe operation from ground level and operating handle with locking arrangement complete in both OFF and ON positions. All ferrous parts hot dripped galvanized and non ferrous heavily tinned to with stand weather suitable for Vertical mounting on existing structure including taking out old us GOD ccomplete all as specified and directed by Engineer-in-charge. |
| 85 | Supply, fixing , commissioning and testing in replacement of outdoor type , 11 KV polymer gang operated switch with drop out fuse assay complete of current rating upto 200 Amps 4 insulator Vertical type triple pole each pole consisting of galvanized steel based HT insulator as per IS non ferrous knife and spring loaded contacts, arching horns of adequate section to break magnetizing current of the transformers vertical GI of adequate length for phase separation , adequate length of GI pipe operation from ground level and operating handle with locking arrangement complete in both OFF and ON positions. All ferrous parts hot dripped galvanized and non ferrous heavily tinned to with stand weather suitable for vertical mounting including taking out old GOD complete all as specified and directed by Engineer-in-charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysSep 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender