Tender For Repair /Maint Of Rmu Vcbs Transformers And Other Connected Works At Lansdowne And Kotdwara Under Age(I) Lansdowne
Tender Value
36 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
15 days left
EMD
72000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pauri Garhwal → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair /Maint Of Rmu Vcbs Transformers And Other Connected Works At Lansdowne And Kotdwara Under Age(I) Lansdowne
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard and dense soil complete all as specified and directed. |
| 2 | All as per item No 01 for each additional 1.5m or partthereof in depth beyond the first 1.5 m complete all as specified and directed. |
| 3 | Returning, filling in, soil including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed. |
| 4 | Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 5 | M&L for 110mm dia HDPE pipe for UG cable fixed in mass concrete pillar over/alomgwith the culvert/drain complete all as specified and as directed. Note- The PCC shall be measured and paid seperately under appropriate item of BOQ |
| 6 | M&L for PCC (1:4:8) Type D2 (using 40 mm graded stone aggre-gate) as in foundations of pole/stay including form work complete all as specified and directed. |
| 7 | M&L for PCC (1:3:6) Type C1 (using 20 mm graded stone aggre-gate) as incoping of poles stud including form work and dismantling of old coping etc complete all as specified and directed. |
| 8 | Dismantling and taking out old unserviceable concrete pole/struts any size complete all as specified and directed. |
| 9 | Dismantling and taking down bend/damaged mild steel work such as cross arms, bracing, supports, clamps & back plates etc complete all as specified and directed. |
| 10 | Dismantling insulators of any type, any size complete all as specified and as directed. |
| 11 | Dismantling of existing unserviceable stay assy any type/size from its stay rod, cutting stay rod (above ground portion ) including stay GI wire, dismantling MS clamps, nuts, bolts, GI stay bow loop insulators etc demolition of concrete and necessary excavation including GI wire complete all as specified and directed. |
| 12 | Disconnecting and taking out old unserviceable GI Pipe and Supply, laying & jointing GI water tubing 100mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed. |
| 13 | S&F of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP 55 (11.0 meter long) as per IS-2713 including painting two coats of aluminium paint over one coat of red oxide primer including 4 Nos band/straps with yellow and black colour in alternate way (250mm wide each) aluminium paint two coat at a distance 300mm from plinth block and marking pole nos with black paint including tarring one coat on steel surface embedded in concrete complete all as specified and directed. Note :- Necessary earth work and excavation, PCC disposal of surplus soil will be measured and paid sepearately |
| 14 | M&L for dismantling of old unserviceable lightening arrester and supply and fix new lightening arrester non liner type confirming to IS No 3070 part I complete with all fittings, transmission class discharge capacity 12KV/10 KA suitable for 11 KV including making connections with over head line with ACSR conductor complete on poles all as specified and directed. |
| 15 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic aluminium paint complete all as specified and directed. |
| 16 | Supply, installation. connecting electrically & commissioning in replacement HT 11 KV outdoor type switch air break, gang operated, tripple pole mounted horizontal or vertical mounting fixed type complete with insulators 15 Nos 200 Amps rating and steel frame mechanically operated mechanism consisting of operating rod 25mm bore light grade GI pipe of suitable length worked from ground level and with locking arrangement flat iron clamp 50mmx6mm including MS channel of suitable size length for fixing GOD including bolts, nuts and washer complete all as specified and directed. |
| 17 | S&F in replacement of existing unserviceable Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 X 20 cm size complete all as specified and directed. |
| 18 | Supply & Fixing stay assembly complete with all accessories, such as stay plate 300x300x6mm, stay rod 215cm long and 20mm dia with nuts including GI Bow turn buckle etc, all as per Electrical Plate No 1 SSR-2009 Part-I complete all as specified and directed. (Necessary excavation and PCC and one set of stay clamps at top of pole & loop insulator of size 90x140mm porcelain, vitreous, white, brown or green shall be measured and paid seperately) |
| 19 | S&F Galvanised stay wire of size 7/4mm all as specified and directed. |
| 20 | M&Lfor loop type insulator porcelain vitirious porcelain white, brown or green large size with overall dimensions 90 x 140 mm clearence of hole 25.5mm complete all as specified and directed. |
| 21 | Supply and fix disc type polymer Insulator with hardware fitting ball and socket type, 70 KN disc assembly for working pressure 11000 Volts complete all as specified and as directed. |
| 22 | Supply and fix pin type polymer Insulator with hardware fitting ball and socket type, 70 KN for working pressure 11000 Volts complete all as specified and as directed. |
| 23 | M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty ) with aluminium conductor, 11/6.35KV grade, suitable for earthed system, with aluminium conductor, 3 core 95 Sqmm complete all as specified and directed. |
| 24 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm complete all as specified and directed. |
| 25 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm complete all as specified and directed. |
| 26 | M&L in repair for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.complete all as specified and directed.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 27 | M&L in repair for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 32x6 mm GI strip as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia medium grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 28 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required Galvanised Iron strip 32x6mm complete all as specified and directed. |
| 29 | Supply only graded stone aggregate of size 20mm around indoor/outdoor substation/ 2 pole/4 pole structure boundry complete all as specified and directed. |
| 30 | M&L for PCC (1:5:10) Type E2 (using 40 mm graded stone aggre-gate) as in sub base including form work complete all as specified and directed. |
| 31 | M&L for prepration of old treated surface of existing steel tubular pole 11 mtr hight without removing accessories and Preparation surfaces for repainting. Repainting the pole with one coat of alternate black and yellow strips of 30 cm upto height of 1.5 mtr using synthetic enamel. Marking the pole number with black enamel paint. Repainting the remaining pole and iron parts steel cross arms i.e 'U' clamps etc above 1.5 Mtr height by applying two coat of synthetic enamel aluminium paint all as required at site complete all as specified and directed. |
| 32 | Disconnecting electrical cable from pole/ transformer in any position and taking up or down unsv under ground cable ,trenching out cables by mannual digging in any location of size 95 sq mm to 120 sq mm and finding of fault by visiual check or by cable fault locator, meggering the cable with 11KV megger and filling of cable end/ straight through joints if required and reconnecting/relayingthe cable in same position complete all as specified and as directed. (Note: Cable end/ straight through joints and other accessories will be measured and paid separately under relavant item of schedule.) |
| 33 | M & L for servicing (as described below) of indoor/outdoor type HT 11 KV VCB of various capacity of Make Crompton Greaves/ABB/ SIEMENS/L&T (a) Servicing and inspecting of draw out type trolly mounted, manual spring charge ON-OFF mechanism and testing for proper functioning of ON and OFF operation ,servicing of male female contacts,greasing all the mechanical components and applying dry graphite conductive sealent for contacts.(b) Cleaning,inspecting and testing HT 11 KV bus bar ,Checking of insulators at input and output for any crack of damages, Checking of cable termination for all the three phases, Cleaning the copper bus bar , checking for proper insulation ,tightening all the nuts ,bolts of bus bar.(c) Cleaning ,inspecting and testing of electrical wiring system, ammeter,voltmeter, VAF meter, selector switch, all illuminated indicators for RYB phase ,DC supply healthy,spring charge ,trip circuit healthy etc(d) Cleaning, inspecting and testing for over current relay ,CT for ammeter ,PT for voltmeter for display of voltage HT 11 KV (e) Setting of earth fault relay and over cuurrent relay as per ,manufacturers's recommendation and site requirement Please Enable Macros to View BoQ information |
| 34 | M & L for servicing (as described below) of indoor/outdoor type HT 11 KV VCB of various capacity of Make Crompton Greaves/ABB/ SIEMENS/L&T (a) Servicing and inspecting of draw out type trolly mounted, manual spring charge ON-OFF mechanism and testing for proper functioning of ON and OFF operation ,servicing of male female contacts,greasing all the mechanical components and applying dry graphite conductive sealent for contacts.(b) Cleaning,inspecting and testing HT 11 KV bus bar ,Checking of insulators at input and output for any crack of damages, Checking of cable termination for all the three phases, Cleaning the copper bus bar , checking for proper insulation ,tightening all the nuts ,bolts of bus bar.(c) Cleaning ,inspecting and testing of electrical wiring system, ammeter,voltmeter, VAF meter, selector switch, all illuminated indicators for RYB phase ,DC supply healthy,spring charge ,trip circuit healthy etc(d) Cleaning, inspecting and testing for over current relay ,CT for ammeter ,PT for voltmeter for display of voltage HT 11 KV (e) Setting of earth fault relay and over cuurrent relay as per ,manufacturers's recommendation and site requirement Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓