Tender For Replacement Of Security Lights And Flood Lights In Different Wards And Buildings, Nirmanshala, Biscuit Factory, 8 Nos Watch Towr And Center Watch Tower In The C Us Of Central Jail, Ghaghidih, Jamshedpur, East Singhbhum.
Tender Overview
Project Description
Tender for Replacement Of Security Lights And Flood Lights In Different Wards And Buildings, Nirmanshala, Biscuit Factory, 8 Nos Watch Towr And Center Watch Tower In The C Us Of Central Jail, Ghaghidih, Jamshedpur, East Singhbhum.
BOQ
| Sl. No. | Item Description |
| 1 | S.I.T.C of following rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be complete with all neccssary accessories as required |
| 2 | a) 90w L.E.D. Campus light.(On building) |
| 3 | S.I.T.C of following rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-5 and shall be complete with all neccssary accessories as required |
| 4 | a) 150/160 watt L.E.D. Flood light. (For 8 No. Watch Tower) |
| 5 | b) 200 watt L.E.D. Flood light. (For Center watch Tower) |
| 6 | Supplying and laying of XLPE insulated PVC sheathed aluminium armoured cable working voltage upto 1100 volts as per IS: 7098 (Part I) of following sizes. |
| 7 | a) 2 core 6 sq mm (for Street light on different building & watch tower) |
| 8 | b) 2 core 10 sq mm (For Flood light for center watch tower) |
| 9 | c) 4 core 16 sq mm (For 8 No. watch tower service connection.) |
| 10 | Laying of one number PVC insulated PVC Sheathed XLPE power cable of 1.1 KV grade of size on wall surface as reqd. up to 35 sq, mm (clamp with 1 mm thik saddle) |
| 11 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground including excavation and refilling the trench etc as reqd. But excluding sand cushioning and protective covering. |
| 12 | Supplying and fixing Cable junction Box with 6 amp SP MCB (Make - Sintex/Hensel or equivelant. |
| 13 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) |
| 14 | a) 2 way single door. |
| 15 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, “B” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required. |
| 16 | a) 63 amp D.P. MCB |
| 17 | S/F PVC / G.I box of following size on surface or in recess with suitable size of phenolic laminated sheet cover inforant including painting etc as reqd. |
| 18 | a) 72 mm x 146mm x 48mm deep/ (4\\" x 7\\") |
| 19 | 6/10 sq mm aluminium lugs |
| 20 | 16 sq mm aluminium lugs |
| 21 | Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 22 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required. |
| 23 | Fabrication and installation of wall mounted cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade including fitting / fixing /connection & transportation up to work site, labour charge etc all complete. |
| 24 | 125 Amps, MCCB 16 KA fixed thermal setting (Incoming) = 1 Nos. |
| 25 | 6/32 Amp Single Pole MCB = 4 Nos. |
| 26 | 32 Amp, double pole MCB = 2 Nos. |
| 27 | 63 Amp, double pole MCB = 2 Nos. |
| 28 | 4.0 sq mm ISI Marked, FR LS PVC Insulated, single core copper conductor cable. 12 Mtr. |
| 29 | 4 sq mm copper lugs 12 Nos. |
| 30 | Digital Volt Mtr. (0-500Volt)- 3 phase class 0.5 1 Nos. |
| 31 | Digital AMP Mtr. (0-500AMP)- 3 phase class 0.5 1 Nos. |
| 32 | C.T. Coil of C.T. Ratio 200/5 IS: 2705 Part - 3 = 3 Nos. |
| 33 | LED Indecator lam R/Y/B/G = 3 Nos. |
| 34 | 25mm x 5mm copper strips (1.15 kg/mtr) = 8 Kg |
| 35 | Fabrication and installation of wall mounted cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade including fitting / fixing /connection & transportation up to work site, labour charge etc all complete. |
| 36 | 150/160 Amps, MCCB 35 KA fixed thermal setting (Incoming) = 1 Nos. |
| 37 | 6/32 Amp Single Pole MCB = 6 Nos. |
| 38 | 32 Amp, double pole MCB = 4 Nos. |
| 39 | 63 Amp, double pole MCB = 4 Nos. |
| 40 | 4.0 sq mm ISI Marked, FR LS PVC Insulated, single core copper conductor cable. 18 Mtr. |
| 41 | 4 sq mm copper lugs 18 Nos. |
| 42 | Digital Volt Mtr. (0-500Volt)- 3 phase class 0.5 1 Nos. |
| 43 | Digital AMP Mtr. (0-500AMP)- 3 phase class 0.5 1 Nos. |
| 44 | C.T. Coil of C.T. Ratio 200/5 IS: 2705 Part - 3 = 3 Nos. |
| 45 | LED Indecator lam R/Y/B/G = 3 Nos. |
| 46 | 25mm x 5mm copper strips (1.15 kg/mtr) = 8 Kg |
| 47 | CGST @ 9% |
| 48 | SGST @ 9% |
| 49 | Labour Cess @ 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender