Tender For Construction And Commissioning Of 01 No. 132Kv Gis Feeder Bay (Outdoor) At 400Kv Gis Substation Agra South.
Tender Value
4.87 Crore
Estimated cost
Bid Submission
14 Sep 2026
21 days left
EMD
4.87 Lakhs
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction And Commissioning Of 01 No. 132Kv Gis Feeder Bay (Outdoor) At 400Kv Gis Substation Agra South.
BOQ
| Sl. No. | Item Description |
| 1 | Tender Inviting Authority: Superintending Engineer, Electricity 765/400 KV Substation Design Circle, U.P. Power Transmission Corporation Limited, 11th Floor, Shakti Bhawan Extension, 14-Ashok Marg, Lucknow-226001 Name of Work: Construction and commissioning of 01 no. 132kV GIS Feeder Bay (Outdoor) at 400KV GIS Substation Agra South. Tender Specification No. : ESD-8/242 Bidder Name : SCHEDULE- 1 SCHEDULE OF QUANTITIES AND PRICES FOR 02 NO. 132KV GIS LINE BAYS (Outdoor) AT 400KV GIS SUBSTATION AGRA SOUTH SUPPLY CHARGES ( All Prices are in Rupees ) Sl. No. EQUIPMENT / ITEM(Complete with all fittings, accessories, associated equipments etc. as specified in Technical Specifications) Unit Quantity for 132 Kv TSS Bhandai Bay Quoted Unit prices in Rs. (Exclusive of GST and other duties & taxes) Total FOR Destination Prices without GST (6x10) Unit Ex-Works Prices Unit Pkg, Fwdg, Charges Unit Freight &Insurance charges Total unit rate without GST (7+8+9) |
| 2 | Line Feeder Bay Module as per 400kV S/S TS Comprising of circuirt breaker, CTs & PTs, disconnectors, grounding switch, line disconnector, cable termination enclosure and local control cubicle. |
| 3 | 132KV Bus Bar Extension including adaptor Module integration required for connecting new 145KV GIS bays with existing Bus bar |
| 4 | 120 KV, 10 KA LA |
| 5 | 132kV Line C&R panel (SAS based) |
| 6 | 132kV Bus Bar Protection Panel (Centralised) |
| 7 | Augmentation of Panel with exiting Busbar Protection Panel |
| 8 | Integration of C&R and Busbar Panel with SAS( Siemens make) |
| 9 | 145 KV, 6 KN Polymer BPI |
| 10 | 0.2s accuracy class ABT Energy Meters |
| 11 | Metering cubicle for ABT energy meters |
| 12 | 2 Ton Split Air conditioner unit complete with suitable voltage stablizer |
| 13 | 1.1 KV PVC armoured Copper Control Cable a 2 core * 2.5 sq. mm. KM 0.2 0.0 0.0 b 4 core * 2.5 sq. mm. KM 0.5 0.0 0.0 c 4 core * 4 sq. mm. KM 0.25 0.0 0.0 d 14 core * 2.5 sq. mm. KM 0.15 0.0 0.0 e 10 core * 2.5 sq. mm. KM 0.2 0.0 0.0 f 6 core * 2.5 sq. mm. KM 0.2 0.0 0.0 |
| 14 | 1.1KV armoured alluminiun Power cable a 2 core * 6 sq. mm. KM 0.3 0.0 0.0 b 4 core x 16 Sq.mm. KM 0.25 0.0 0.0 |
| 15 | HT Cable a 145kV, 1-Core, 630sq.mm, XLPE copper cable. for 132kV GIS as per design and rating (3 phase X 220 mtr) Mtr 200.0 0.0 0.0 b 145 kV Termination Kit at both ends for 1 X 630 sq mm XLPE copper cable(one end is GIS type and other end is AIS type) Set 3.0 0.0 0.0 c Single Core 3.3 KV 300 sq. mm sheath Bonding Coaxial cable Mtr 25.0 0.0 0.0 d single core 300 sq. mm Copper Conductor PVC insulated 3.3 KV grade Earthing Cable Mtr 125.0 0.0 0.0 e Single Phase Link box with/without SVL as required Nos. 2.0 0.0 0.0 f Three Phase Link Box with/without SVL as required Nos. Nos. 1.0 0.0 0.0 g HDPE Pipe suitable for above XLPE Cable Mtr. Mtr 15.0 0.0 0.0 h Aluminium Alloy Single clamps Nos. 12.0 0.0 0.0 i Aluminium Alloy trefoil clamps Nos. 100.0 0.0 0.0 j Terminal Connector Nos. 2.0 0.0 0.0 |
| 16 | Main & Aux Structures with MS angles, channels, plates, nuts, bolts, step bolts, U bolts, spring washers, etc.,and any other required material a ERW Pipe Structure MT 0.75 0.0 0.0 b Steel Structure including lattice structure & nut bolts MT 5.0 0.0 0.0 c ACSR Panther km 0.25 0.0 0.0 d 70 KN antifog disc insulators Nos. 35.0 0.0 0.0 e Single Suspension Fittings Suitable for ACSR Panther Nos. 3.0 0.0 0.0 f PG clamps suitable for panther/panther Nos. 8.0 0.0 0.0 g Bus Post Clamps suitable for panther Nos. 4.0 0.0 0.0 h 50x6 mm MS Flat for cable trench/panel earthing etc. Mtr 100.0 0.0 0.0 i 25x6 mm MS Flat RM 50.0 0.0 0.0 j 75X12 mm MS Flat for cable trench/panel earthing etc. Mtr 100.0 0.0 0.0 k 75x12mm Copper Flat( For GIS switchgear Screening, Shielding and earthing) Mtr 25.0 0.0 0.0 l 40mm MS rod for Main Earthmat Mtr 50.0 0.0 0.0 m 40mm dia MS Electrodes (3 M Long) Nos 4.0 0.0 0.0 |
| 17 | Earthing Material 0.0 Total 0.0 Total for 01 no. 132kV GIS Feeder Bay (Outdoor) at 400kV S/S Agra South (without GST) 0.0 GST (@18%) 0.0 Total for 01 no. 132kV GIS Feeder Bay (Outdoor) at 400kV S/S Agra South (with GST) 0.0 Note : 1- Bidder is required to quote prices in this Schedule for all the individual items/sub-items. 2- Please confirm that the prices are after taking into account ITC benefits. As per section 171 of CGST act 2017, \\" any reduction in rate of tax any supply of goods or services or the benefit of input tax credit shall be passed on to the recipient by way of commensureate reduction of prices. Hence supplier/ manufacture to ensure to passe the benefit of reduced prices to UPPTCL. Further prices quoted by supplier/manufacturer is subject to scrutiny under above section.\\" 3- Evaluation of Tender shall be made after loading 18% GST (present rate) on all items including supply, erection, Testing & commissioning and civil work asuming the work as Work Contract. Place: Tender Inviting Authority: Superintending Engineer, Electricity 765/400 KV Substation Design Circle, U.P. Power Transmission Corporation Limited, 11th Floor, Shakti Bhawan Extension, 14-Ashok Marg, Lucknow-226001 Name of Work: Construction and commissioning of 01 no. 132kV GIS Feeder Bay (Outdoor) at 400KV GIS Substation Agra South. Tender Specification No. : ESD-8/242 Bidder Name : SCHEDULE- 2 SCHEDULE OF QUANTITIES AND PRICES FOR 02 NO. 132KV GIS LINE BAYS (Outdoor) AT 400KV GIS SUBSTATION Agra South HANDLING, ERECTION, TESTING AND COMMISSIONING CHARGES (All Prices are in Rupees) Sl. No. EQUIPMENT / ITEM(Complete with all fittings, accessories, associated equipments etc. as specified in Technical Specifications) Unit Quantity for 132 Kv TSS Bhandai Bay Unit Handling, Erection,Testing & Commissioning Charges without GST Total Handling, Erection,Testing & Commissioning Charges without GST(4x5) |
| 18 | Line Feeder Bay Module as per 400kV S/S TS Comprising of circuirt breaker, CTs & PTs, disconnectors, grounding switch, line disconnector, cable termination enclosure and local control cubicle. |
| 19 | 132KV Bus Bar Extension including adaptor Module integration required for connecting new 145KV GIS bays with existing Bus bar |
| 20 | 120 KV, 10 KA LA |
| 21 | 132kV Line C&R panel (SAS based) 132kV Bus Bar Protection Panel (Centralised) Nos 1.0 0.0 |
| 22 | Augmentation of Panel with exiting Busbar Protection Panel |
| 23 | Integration of C&R and Busbar Panel with SAS( Siemens make) |
| 24 | 145 KV, 6 KN Polymer BPI |
| 25 | 0.2s accuracy class ABT Energy Meters |
| 26 | Metering cubicle for ABT energy meters |
| 27 | 2 Ton Split Air conditioner unit complete with suitable voltage stablizer |
| 28 | 1.1 KV PVC armoured Copper Control Cable a 2 core * 2.5 sq. mm. KM 0.2 0.0 b 4 core * 2.5 sq. mm. KM 0.5 0.0 c 4 core * 4 sq. mm. KM 0.25 0.0 d 14 core * 2.5 sq. mm. KM 0.15 0.0 e 10 core * 2.5 sq. mm. KM 0.2 0.0 f 6 core * 2.5 sq. mm. KM 0.2 0.0 |
| 29 | 1.1KV armoured alluminiun Power cable a 2 core * 6 sq. mm. KM 0.3 0.0 b 4 core x 16 Sq.mm. KM 0.25 0.0 |
| 30 | HT Cable a 145kV, 1-Core, 630sq.mm, XLPE copper cable. for 132kV GIS as per design and rating (3 phase X 220 mtr) Mtr 200.0 0.0 b 145 kV Termination Kit at both ends for 1 X 630 sq mm XLPE copper cable(one end is GIS type and other end is AIS type) Set 3.0 0.0 c Single Core 3.3 KV 300 sq. mm sheath Bonding Coaxial cable Mtr 25.0 0.0 single core 300 sq. mm Copper Conductor PVC insulated 3.3 KV grade Earthing Cable Mtr 125.0 0.0 e Single Phase Link box with/without SVL as required Nos. 2.0 0.0 Three Phase Link Box with/without SVL as required Nos. Nos. 1.0 0.0 HDPE Pipe suitable for above XLPE Cable Mtr. Mtr 15.0 0.0 h Aluminium Alloy Single clamps Nos. 12.0 0.0 i Aluminium Alloy trefoil clamps Nos. 100.0 0.0 Terminal Connector Nos. 2.0 0.0 |
| 31 | Main & Aux Structures with MS angles, channels, plates, nuts, bolts, step bolts, U bolts, spring washers, etc.,and any other required material a ERW Pipe Structure MT 0.75 0.0 b Steel Structure including lattice structure & nut bolts MT 5.0 0.0 c ACSR Panther km 0.25 0.0 d 70 KN antifog disc insulators Nos. 35.0 0.0 e Single Suspension Fittings Suitable for ACSR Panther Nos. 3.0 0.0 PG clamps suitable for panther/panther Nos. 8.0 0.0 Bus Post Clamps suitable for panther Nos. 4.0 0.0 g 50x6 mm MS Flat for cable trench/panel earthing etc. Mtr 100.0 0.0 h 25x6 mm MS Flat RM 50.0 0.0 i 75X12 mm MS Flat for cable trench/panel earthing etc. Mtr 100.0 0.0 j 75x12mm Copper Flat( For GIS switchgear Screening, Shielding and earthing) Mtr 25.0 0.0 k 40mm MS rod for Main Earthmat Mtr 50.0 0.0 l 40mm dia MS Electrodes (3 M Long) Nos 4.0 0.0 m Earthing Material Nos. 1.0 0.0 Total 0.0 Total for 01 no. 132kV GIS Feeder Bay (Outdoor) at 400kV S/S Agra South (without GST) 0.0 GST (@18%) 0.0 Total for 01 no. 132kV GIS Feeder Bay (Outdoor) at 400kV S/S Agra South (with GST) 0.0 Tender Inviting Authority: Superintending Engineer, Electricity 765/400 KV Substation Design Circle, U.P. Power Transmission Corporation Limited, 11th Floor, Shakti Bhawan Extension, 14-Ashok Marg, Lucknow-226001 Name of Work: Construction and commissioning of 01 no. 132kV GIS Feeder Bay (Outdoor) at 400KV GIS Substation Agra South. Tender Specification No. : ESD-8/242 Bidder Name : SCHEDULE- 3 SCHEDULE OF QUANTITIES AND PRICES FOR 02 NO. 132KV GIS LINE BAYS (Outdoor) AT 400KV GIS SUBSTATION AGRA SOUTH MANDATORY SPARS ( All Prices are in Rupees ) Sl. No. EQUIPMENT / ITEM(Complete with all fittings, accessories, associated equipments etc. as specified in Technical Specifications) Unit Qty. Quoted Unit prices in Rs. (Exclusive of GST and other duties & taxes) Total FOR Destination Prices without GST (4x8) Unit Ex-Works Prices Unit Pkg, Fwdg, Charges Unit Freight &Insurance charges Total unit rate without GST (5+6+7) |
| 32 | 2.0 Not Applicable |
| 33 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m (DSR 2.8.1) |
| 34 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials for All kind of soil (DSR 2.26.1) |
| 35 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)(DSR 4.1.8) |
| 36 | Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns (DSR 4.3.1) |
| 37 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete(DSR 5.9.1) |
| 38 | Supply and filling in plinth with sand under floors,including watering,ramming,consolidating and dressing complete.( DSR NO.2.27 ) |
| 39 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)(DSR 4.1.2 ) |
| 40 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2) |
| 41 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(DSR 5.3) |
| 42 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts(DSR NO. 5.9.6 ) |
| 43 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform(DSR 5.9.3) |
| 44 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth leve Thermo-Mechanically Treated bars of grade Fe-500D or more.(DSR 5.22.6) |
| 45 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR NO. 6.1.2) |
| 46 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) |
| 47 | Supply of 28 mm. dia M.S. Anchor bolts (conforming to IS 266) 900 mm. long with base plate (75x75x6mm) welded with anchor bolts including its threading upto a length of 10cm. and also supply of a pair of galvanized standard nuts with threading including supply of 5 mm thick washer and cost of labour, material & T&P for proper completion of work(DSR NSI No.9.12) |
| 48 | Fixing and grouting 52/40/32/28 mm bolts in proper alignment level and setout with help of a template complete including supply of all labour & T&P etc. required for proper completion of the work.(labour rates only) (DSR NSI No. 9.13) |
| 49 | Supply of 25 mm dia.M.S. Anchor bolts (conforming to IS-226) 500 mm long with base plate(50x50x6 mm)welded with anchor bolts,including its threading upto a length of 10cm. and galvanizing upto 15cm from top, also supply of a pair of galvanized standard nuts with threading including supply of 5mm thick washer and cost of labour material and T&P etc. required for proper completion of the work. (DSR NSI No. 9.14) |
| 50 | Fixing and grouting 25 mm dia M.S. Anchor bolt in proper alignment level and setout with the help of a template including supply of all labour T&P etc. reqd. for proper completion of the work. (labour rates only).(DSR NSI No. 9.15) |
| 51 | Fixing of template in position level and alignment for grouting of Anchor bolt in main gantry (labour rate only)(DSR NSI No.9.31) |
| 52 | Fixing of template in position level and alignment for grouting of Anchor bolt in Auxiliary (labour rate only)(DSR NSI No.9.32) |
| 53 | Fixing of cable trench racks in proper position and alignment including cost of all labour, material and T&Petc. required for proper completion of the work (Labour rate only)(DSR NSI No.9.33 ) |
| 54 | Fabrication of template for main gantry foundation including cost of all labour, and T&P etc. required for proper completion of the work. Steel shall be arranged by contractor free of cost. This template shall be property of contractor.(Labour rate only). (DSR NSI No.9.35 ) |
| 55 | Fabrication of template for Auxiliary foundation including cost of all labour, and T&P etc. required for proper completion of the work. Steel shall be arranged by contractor free of cost. This template shall be property of contractor.(Labour rate only). (DSR NSI No. 9.36 ) |
| 56 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(DSR NO 10.2) |
| 57 | Placing of trench cover of all size in proper position including transportation from different places within the S/S area including all labour, T&P etc. required for proper completion of the work as per direction of Engineer - in - charge. (NSI 20.11) |
| 58 | Champering the edge of concrete in auxiliary structure, of size 25 mm wide in triangular section including all materials, labour & T&P etc complete. (DSR NSI No.11.18) |
| 59 | 40 mm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC (DSR NSI No.12.28) |
| 60 | 12 mm thick plaster with cement mortar consisting of one part of cement & four part of coarse sand (1:4), minimum thickness not to be less then 10 mm including supply of all material, labour and T&P etc for proper completion of work. (DSR 13.4.1) |
| 61 | Neat cement punning. (DSR No. 13.18) |
| 62 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (DSR 13.62.1) |
| 63 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR 15.3) |
| 64 | Demolishing brick work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. (DSR 15.7.4) |
| 65 | Providing and laying C.C. pavement of mix M-20 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(DSR 16.75-16.76) |
| 66 | Extra for providing and mixing hardening compound of approved quality as per manufacturer's specification in cement concrete.(DSR No. 16.44) |
| 67 | Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)(DSR No.16.45) |
| 68 | Fixing and grouting of trench edging in proper level and alignment including cost of all labour, and T&P etc. required for proper completion of the work but excluding cost of C.C. (labour rates only) (NSI 9.30). |
| 69 | Fixing of cable trench racks in proper position and alignment including cost of all labour, material and T&Petc. required for proper completion of the work (Labour rate only).(NSI No. 9.33) |
| 70 | Arranging and spreding 75 mm thick broken grit 20 mm (Granite stone) uniform for turfing over 100mm thick base course of C.C. In 1:4:8 (1cement:4coarse sand: 8, 40mm stone ballast) top finish by brooming of cement mortar 1:4(1cement: 4 Coarse sand) including supply of all materials, labour and tools and plants etc. required for proper completion. (NSI No 5.31). |
| 71 | Supplying and Laying of Stone Aggregate (Single Size):40 mm nominal size (DSR Material Code No.0293+10%C.P.) Tender Inviting Authority: Superintending Engineer, Electricity 765/400 KV Substation Design Circle, U.P. Power Transmission Corporation Limited, 11th Floor, Shakti Bhawan Extension, 14-Ashok Marg, Lucknow-226001 Name of Bidder: SCHEDULE- 5 Tender Specification No. : ESD-8/242 Summary Price Schedule Construction and commissioning of 01 no. 132kV GIS Feeder Bay (Outdoor) at 400KV GIS Substation Agra South. SI. No. Description Amount (in Rs.) |
| 72 | Total Price for Supply of Equipments and Material [Schedule-1 ] |
| 73 | Total Handling, Erection, Testing & Commissioning Charges [Schedule-2] |
| 74 | Total Price for Supply of Mandatory Spares [Schedule-3 ] |
| 75 | Total Charges for Civil works including supply of materials [Schedule-4] |
| 76 | Summary of Total Price (1+2+3+4) |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysSep 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender