Tender For Electrification Of New Covered Storage Shed Near Sj Gate.
Tender Value
11.84 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
10 days left
EMD
27954
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dakshina Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrification Of New Covered Storage Shed Near Sj Gate.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying of LT UG cable of size 3.5Cx95 sq mm having Aluminium conductor XLPE insulated, sheathed, galvanized, steel wire/steel tape armoured cable 1.1KV class. |
| 2 | Labour charges for laying of 3.5Cx95 Sq.mm UG cable in existing trench. |
| 3 | Supplying and making end termination with glands, lugs of the LT UG Cable. a) 3.5C X 95 SQ.MM |
| 4 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm around the cable. |
| 5 | Supplying & laying of RCC semi cut pipe(C-CUT) in existing trench over the cable. Size:150mm dia, 25 mm thick. |
| 6 | Supplying of 4 Core x 4 sq.mm LT, UG cable having copper conductor XLPE insulated sheathed, Galvanized, steel wire armored cable with PVC outer sheathing 1.1KV class. |
| 7 | Labour charges for laying of 4 core x 4 sq.mm armoured UG cable /on wall/structure as required with necessary saddles/clamps etc completed. |
| 8 | Supplying and running 4 sq mm PVC insulated multi strand single core copper wire in open system for grounding connection using fixing materials as required. |
| 9 | Supplying and drawing of 3C x 2.5sq.mm Flexible multi core cable manufactured flexible copper flexible PVC and insulated and sheathed 1100V grade cable from Marshaling box to lighting fixture. |
| 10 | Supplying of PVC flexible conduit pipe 20mm dia for covering flexible cables fixing on wall by using heavy gauge saddles using NF screws etc complete. |
| 11 | Supplying of 150W LED flood light fitting as per technical specification. |
| 12 | Fixing of 150W LED flood light fitting over existing angle iron frame using SS bolts, nuts focusing to the working area wiring complete. |
| 13 | Supplying and Installation/fixing provision of box for MCB and CBT connectors for 3ph/1ph connections with loop-in and loop-out for terminating 4C x 4 sq.mm branch out 3C X 2.5sq.mm copper cable enclosed in a 260 x 210 x 116 mm thermo plastic polystyrene enclose it should be shock proof safe rust proof IP65 rust proof, dust proof, water proof having internally embedded Gasket with provision for cable entry through IP65 thermoplastic polyamide glands. Work including supply & fixing of 10A DP MCB and 5 Nos. M6 CBT connector and terminating the incoming and outgoing cables by using suitable lugs. |
| 14 | Supplying and fixing angle iron frame work fabricated out of Ms angle iron of size 40x40x6mm and MS flat of 40x6mm with SS bolt, nuts washer etc. (or fixing as required at site), complete and painted with 2 coats of red oxide and then 2 coats of approved paint suitable for mounting light fitting. |
| 15 | Supply, Installation and fixing of thermoplastic modular Panel enclosure of size 600x600x170mm with transparent polycarbonate lid, shock proof, IP65 weather proof, rust proof, dust proof, water proof, corrosion proof having internally embedded, gasket on both lid and flap with Hylum sheet (for fixing the component inside the box) suitable to fix 125A, 25KA, MCCB, MCBs and CBT connectors work including fixing the enclosure in the existing wall and fixing of CBT connectors. Work including supply of suitable rails (for fixing MCBs timer and CBT connectors) glands, fork busbar for MCBs neutral link (Bolt and nut type) and all wire and internal wiring in the enclosure by using suitable materials (such as wire and lugs) and provision for 3.5Cx95sq.mm cable gland for incomer and glands for 4Rx4Cx4sq.mm outgoing cable. The connection between MCCB to contactor and contactor to MCBs should be through 16sq.mm flexible copper wire and other wiring (from MCB to connector) through 6sq.mm copper wire with required lugs from MCB to connector, complete. |
| 16 | Supplying of 4pole, 125A, 25KA, MCCB. |
| 17 | Supplying of 16A, DP MCB’s. |
| 18 | Supplying of 16A single pole MCB’s. |
| 19 | Supplying of M6 CBT connectors. |
| 20 | Supplying of 3pole 60A contactor. |
| 21 | Supplying of Electromechanical Time switch 24Hour programmer. |
| 22 | Supplying and fixing earth electrode for grounding of light circuits, using 40mm dia., 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh and suitable –SBC reducer fixed on top of earth electrode. The funnel should be enclosed in CC chamber of 400x400x100mm with cast iron cover. The earth electrode shall have staggered holes of 12mm dia. And the electrode should be coved 150mm around pipe complete depth with alternate layers of salt and charcoal. The connection from the electrode is to be established through 25x3 copper flat using GI bolts and nuts. |
| 23 | Supplying and running 25x3mm copper strip for grounding connection using fixing materials as required. |
| 24 | Supply of following 2C x 4sqmm size 1.1KV grade XLPE insulated, PVC Sheathed, armoured copper conductor cable conforming to IS 7098(Part 1) amended upto date. |
| 25 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following up to 35 sq mm in ground including excavation, sand cushioning, providing protective covering and refilling the trench etc as required. |
| 26 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface, recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. a) 8way, Double door. |
| 27 | Supplying and fixing 240V/415V,10 KA, ”C” curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc., as required. a) 6 Amps SP |
| 28 | Supplying and fixing 240V/415V,10 KA, ”C” curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc., as required. a) 16 Amps DP |
| 29 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in the case of recessed conduit as required. a) 19/20mm dia 2mm thick |
| 30 | Wiring for light point/exhaust point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as required. |
| 31 | Supply of indoor decorative surface mounted LED batten with polycarbonate diffuser, along with driver, system wattage of maximum 20watts, lumen output of luminaire greater than 2000, power factor >0.9, rated life of L70 @25000 hours, system efficiency greater than 100 lumen/watt and including all the necessary accessories as required complete. |
| 32 | Installation, testing and commissioning of pre wired LED fitting of all types, complete with all accessories and tube etc. directly on ceiling/wall including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 33 | Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. |
| 34 | Installation, testing and commissioning of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing & commissioning etc as required. |
| 35 | Suppliny and Laying reinforced cement concrete pipe NP3 for culverts including pionting ends and fixing collars with cement mortar 1:2 including cost of materials, labour, HOM complete as per specifications, curing complete as per specifications No. KSRB1000/2300 a) 300mm dia |
| 36 | Supplying and laying of 90mm dia (OD 90 mm & ID 76 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc, confirming to IS 14930, Part II complete with fitting and cutting, jointing etc in existing trench, complete as required. |
| 37 | Supplying and laying of 63mm dia (OD 63 mm & ID 51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc, confirming to IS 14930, Part II complete with fitting and cutting, jointing etc in existing trench, complete as required. |
| 38 | Supplying of 3.5C x 35 SQ.MM, 1.1KV XLPE insulated, PVC extruded inner sheath Aluminium Armoured UG LT Cable as per IS-1554(Part-I) or IS-7098(Part-I) Armouring strip thickness and resistivity as per IS-3975. |
| 39 | Labour charges for laying of 3.5C x 35 SQ.MM, 1.1 KV class XLPE LT UG Cable in existing trench / GI pipe / Stoneware pipe / on pole/on concrete wall as required. |
| 40 | Supplying and making end terminations of cable with suitable glands, crimping the lugs in the Feeder pillars with supply, fixing of all required hard ware complete. a) 3.5 C x 35 sq.mm. |
| 41 | Earth work excavation for cable trench of 0.5 to 0.75mtr width and depth up to l mtr and laying of 1.1 KV class XLPE UG cable up to size 3.5CX35 SQMM/3.5CX95SQMM & refilling cable trenches with selected available earth from trench excavation including, watering, consolidations. |
| 42 | Digging of trench for laying of LT cables and refill the trench, In some places concrete & asphalt whenever removed, refixed the pavor blocks, re-concrete/ asphalt the road in hard soil 1.5m deep x 0.5m wide (concrete cutting). |
| 43 | Supplying and laying of 100mm dia B class GI pipes for culverts/drain crossing/GI Pipe/trench and cable raising, work includes supplying collars, GI clamps and GI nuts, bolts, washers for fixing pipe to drain wall complete etc. LMR |
| 44 | Supplying and installing Cable Route Marker made up of RCC Block of size 100cm (H) X 50CM (W) x 6cm (D) indicating Embossed text as \\"NMP LT Cable\\" with yellow paint a red colour letters and fixing with cement concrete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender