Agriculture Boards / Undertakings / PSU Closing in 7 days TDR #56986668

Tender For Annual Maintenance Contract (Amc) Of Various Electrical & Mechanical Services And Procurement Of Electrical Items At Fci Regional Office, Jammu

Issued by Boards / Undertakings / PSU · Jammu, Jammu and Kashmir
Tender Value
4.65 Lakhs
Estimated cost
Bid Submission
20 Aug 2026
7 days left
EMD
9320
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Annual Maintenance Contract (Amc) Of Various Electrical & Mechanical Services And Procurement Of Electrical Items At Fci Regional Office, Jammu

BOQ

Name of Work:- Annual Maintenance Contract (AMC) of Various Electrical & Mechanical Services and procurement of electrical items at FCI Regional Office, Jammu
Sl. No. Item Description
1Annual Maintenance Contract of Various Electrical Mechanical Services as per details given in relevent sections by deploying the required staff including specialized manpower and by arranging required tools and plant etc. to keep all the services operational up to the required standards. A) Services included are:- 1) EI and Fans 2) Lightning conductor 3) Office Lighting 4) Pumps 5) Sub Station 6) Servicing of ACs . Contractors to take all the steps to undertake preventive / special maintenance and testing to keep the system at optimum working condition. B) Minimum Staff required:- a) Wireman Gr. 1 - 01 Nos on all office working days (Maintenance of Electrical Installation of office)
2LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C):Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm):36 Watt
3LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C):Powder Coated CRCA Sheet Body (Thickness >0.50 mm):36 Watt
4Supplying following modular switch/ socket etc. as required:5/6 A switch
5Supplying following modular switch/ socket etc. as required:15/16 A switch
6Supplying following modular switch/ socket etc. as required:3 pin 5/6 A socket outlet
7Providing of following size ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable etc. as required:1.5 sq mm
8Providing of following size ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable etc. as required.2.5 sq mm
9Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required:900mm, service value ≥ 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum)
10Providing and filling of refrigerant gas (R-22 / R-410A / R-32 as applicable) in air conditioner system after carrying out leak testing, vacuumization and necessary repairs, complete as required.The work includes checking of complete refrigeration circuit, rectification of minor leakages, evacuation of system using vacuum pump, charging of refrigerant gas up to required pressure, and testing for satisfactory operation of the unit, complete in all respects as per manufacturer’s specifications. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56986668
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 4.65 Lakhs
LAST DATE 20-08-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for Annual Maintenance Contract (Amc) Of Various Electrical & Mechanical Services And Procurement Of Electrical Items At Fci Regional Office, Jammu
Basic Detail
Tender No EM/JK/01/2026
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 12 Aug 2026
Submission Date 20 Aug 2026
Open Date 21 Aug 2026
Finance
Tender Value 4.65 Lakhs
Tender Fee Ref. Documents
EMD 9320
Exemption Not Available
Document List
0d13993a-6eea-4ba0-a9f1-3767986b07e4.html
BOQ_968772.xls
MTF.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

0d13993a-6eea-4ba0-a9f1-3767986b07e4.html

xls

BOQ_968772.xls

pdf

MTF.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders