Tender For Annual Maintenance Contract (Amc) Of Various Electrical & Mechanical Services And Procurement Of Electrical Items At Fci Regional Office, Jammu
Tender Value
4.65 Lakhs
Estimated cost
Bid Submission
20 Aug 2026
7 days left
EMD
9320
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Maintenance Contract (Amc) Of Various Electrical & Mechanical Services And Procurement Of Electrical Items At Fci Regional Office, Jammu
BOQ
| Sl. No. | Item Description |
| 1 | Annual Maintenance Contract of Various Electrical Mechanical Services as per details given in relevent sections by deploying the required staff including specialized manpower and by arranging required tools and plant etc. to keep all the services operational up to the required standards. A) Services included are:- 1) EI and Fans 2) Lightning conductor 3) Office Lighting 4) Pumps 5) Sub Station 6) Servicing of ACs . Contractors to take all the steps to undertake preventive / special maintenance and testing to keep the system at optimum working condition. B) Minimum Staff required:- a) Wireman Gr. 1 - 01 Nos on all office working days (Maintenance of Electrical Installation of office) |
| 2 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C):Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm):36 Watt |
| 3 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C):Powder Coated CRCA Sheet Body (Thickness >0.50 mm):36 Watt |
| 4 | Supplying following modular switch/ socket etc. as required:5/6 A switch |
| 5 | Supplying following modular switch/ socket etc. as required:15/16 A switch |
| 6 | Supplying following modular switch/ socket etc. as required:3 pin 5/6 A socket outlet |
| 7 | Providing of following size ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable etc. as required:1.5 sq mm |
| 8 | Providing of following size ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable etc. as required.2.5 sq mm |
| 9 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required:900mm, service value ≥ 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum) |
| 10 | Providing and filling of refrigerant gas (R-22 / R-410A / R-32 as applicable) in air conditioner system after carrying out leak testing, vacuumization and necessary repairs, complete as required.The work includes checking of complete refrigeration circuit, rectification of minor leakages, evacuation of system using vacuum pump, charging of refrigerant gas up to required pressure, and testing for satisfactory operation of the unit, complete in all respects as per manufacturer’s specifications. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysAug 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender