Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56986589

Tender For Electrical Work In Principal Office Along With Washroom And Adjoining Area In Aditi Mahavidyalaya, Bawana, Delhi.

Issued by Government Departments · Delhi, Delhi
Tender Value
15.89 Lakhs
Estimated cost
Bid Submission
20 Aug 2026
6 days left
EMD
31790
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Electrical Work In Principal Office Along With Washroom And Adjoining Area In Aditi Mahavidyalaya, Bawana, Delhi.

BOQ

Name of Work:- Electrical Work in Principal Office along with Washroom and Adjoining area in Aditi Mahavidyalaya, Bawana, Delhi.
Sl. No. Item Description
1Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.a) Group C
2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
3b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4c) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
5d) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
6Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as requireda) 3 x 1.5 sq. mm
7b) 6 x 1.5 sq. mm
8c) 3 x 4 sq. mm
9d) 6 x 4 sq. mm
10e) 3 x 6 sq. mm
11f) 6 x 6 sq. mm
12Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.a) 20 mm
13b) 25 mm
14c) 32 mm
15Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
16Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
17Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
18Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
19Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.a) 8 Module (125mmX125mm)
20b) 12 Module (200mmX150mm)
21c) 6 Module (200mmX75mm)
22Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 amps switch
23b) 3 pin 5/6 amp socket outlet
24c) 15/16 amp switch
25d) 6 pin 15/16 amp socket outlet
26Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
27Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolatora) 8 way (4 + 24), Double door
28Supplying and fixing following capacity 240/415 Volts, ‘C’ series, Miniature Circuit Breaker (MCB) suitable for lighting and other loads of following poles in the existing MCB DB, complete with connections, testing and commissioning etc. as required.a) 100 Amp FPMCB
29Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requireda) Single pole
30Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections,Ics=100% Icu and Operational Voltage 690V etc. as required .a) 125 A ,16 KA, TPMCCB
31b) 200 A, 16 KA,TPMCCB
32c) 315 A, 35 KA,TPMCCB
33Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS :10322 with driver as per the requirement with Driver efficiency>85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)a)36 watt
34Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)a) 36 watt
35Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
36Supplying and Installation of 250 mm dia PVC ventilation / fresh air fan alongwith louvers including making the hole to suitable the size of the above fan i/c making good the damage, connections, testing, commissioning etc as reqd.
37Supplying Installation, testing and commissioning of wall mouted bracket fan sweep 400 mm PVC body with air delivery 80 m3/min and 1300 rpm, including making connection with 3x1.5 sqmm copper conductor PVC insulated etc. complete as required.
38Supply , Installation, Testing and Comissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year Original Equipment Manufact urer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).a) 1.5 TR with 3 Star BEE Rating, Inverter Type - Hot & Cold
39Supply installation, testing and commissioning of wall mounted/terrace mounted bracket to with stand weight of AC outdoor unit, as approved by E-in-C, weather proof, suitable primer and painted, suitable for existing outdoor unit of Split AC etc complete as reqd.
40Supplying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size complete as required.a) 3.5 X 70 sqmm
41Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as requireda) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
42Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.a) 3½ X 70 sq. mm (38mm)
43Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
44Supplying, Installation, testing and commissioning of Metal Enclosure fabricated from 2 mm CRCA Sheet and in-built link suitable upto 4 Pole,125 A MCCB and and to accommodate upto 70 sq. mm. 3.5 core Aluminum armoured cable etc. complete as required at site.
45Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
46Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
47Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
48Dismantling of following electrical material and credit for same as the material shall be retained with contractor Copper/alumimium wire cut pieces assorted size
49Assorted size Switch/Sockets etc
50Assorted size SP, SPN MCB
51Wall fans 400 mm
52MCCB assorted size/capacity etc.
53Existing LED fitting as 2X2\\" Ft. panel
54LED Batten
55Modular Sheet i/c GI Box (3M to 8M)
56Non Working existing Air conditioner (1.5/2 TR)
57Ceiling Fan Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56986589
AUTHORITY Government Departments
TENDER VALUE 15.89 Lakhs
LAST DATE 20-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Electrical Work In Principal Office Along With Washroom And Adjoining Area In Aditi Mahavidyalaya, Bawana, Delhi.
Basic Detail
Tender No 18/EE(E)/NED/PWD/M-352/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 12 Aug 2026
Submission Date 20 Aug 2026
Open Date 20 Aug 2026
Finance
Tender Value 15.89 Lakhs
Tender Fee Ref. Documents
EMD 31790
Exemption Available
Document List
BOQ_395384.xls
cfca2faf-f3e2-490a-84f2-f967d120dce0.html
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_395384.xls

html

cfca2faf-f3e2-490a-84f2-f967d120dce0.html

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders