Tender For Construction Of Overhead Service Reservoir (200 Kl) Of Samrala Major Lift Scheme Along With Allied Works
Tender Value
1.48 Crore
Estimated cost
Bid Submission
02 Sep 2026
18 days left
EMD
2.97 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Overhead Service Reservoir (200 Kl) Of Samrala Major Lift Scheme Along With Allied Works
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking theexcavated soil clear from the edge of excavation. (csr item no. 6.6) |
| 2 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 3 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering)including attached pilasters, buttresses etc when curved. |
| 4 | Centering and shuttering for columns (circular or curved in plain) |
| 5 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 6 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. |
| 7 | Centring and shuttering for R.C.C. domes |
| 8 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.4 to 5m |
| 9 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.5 to 6 |
| 10 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.6 to 7 |
| 11 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.7 to 8 |
| 12 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.8 to 9 |
| 13 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.9 to 10 |
| 14 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof10 to 11 |
| 15 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 11 to 12 |
| 16 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof12 to 13 |
| 17 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof13 to 13.6m |
| 18 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.4 to 5m |
| 19 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.5 to 6 |
| 20 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.6 to 7 |
| 21 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.7 to 8 |
| 22 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.8 to 9 |
| 23 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.9 to 10 |
| 24 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.10 to 11 |
| 25 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.11 to 12 |
| 26 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.12 to 13 |
| 27 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof.13 to 13.6m |
| 28 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 29 | Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey |
| 30 | Cement concrete 1:3:6With stone ballast or shinglemixing by mechanical means using concrete mixer volumetric type |
| 31 | Extra for using needle vibrator where not included in therates. |
| 32 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 33 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in Superstructure |
| 34 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete. |
| 35 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position. (For Stair Railing) |
| 36 | Providing and applying integreal crystalline slurry of hydrophilic in nature for water proofing management etc. (for vertical surface) |
| 37 | Providing and applying integreal cristline slurry of hydrophilic in nature for water proofing management etc.(for horizontal surface) |
| 38 | Providing and applying of swellable type water stop tape etc. |
| 39 | Providing and fixing stair case railing made out of M.S. Square bars 20x20m as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects. |
| 40 | Providing and fixing RCC/OHSR ventilators, complete with MS frame, mosquito-proof wire mesh. fixing arrangement and all incidental works, complete in all respects as directed by the Engineer-in-charge. |
| 41 | Supply of Aviation Obstruction Light complete including wiring etc. (for OHSR/tower/high rise buidling; medium intensity) |
| 42 | Supply of Aluminium Lightening Conductor Complete Including wiring Earthing etc. |
| 43 | Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects |
| 44 | Providing and fixing RCC manhole covers only 560mm i/d RCC man hole cover only as per ISIExtra Heavy duty |
| 45 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 46 | Providing, fabricating, machining, supplying and fixing MS Tailpiece with machine spigot end suitable for joining 900 mm dia DI pipe with 900mm dia MS pipe including welding, gasket, alignment and all incidental works complete. |
| 47 | Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS :1239/3589 including fittings like tees,bends, sockets, elbows, flanges, tapers, nuts bolts,gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts.914 mm i/d 10 mm thickness with Epoxy |
| 48 | Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty flanged MS Pipe conforming to Indian Standard IS :1239/3589 including fittings like tees,bends, sockets, elbows, flanges, tapers, nuts bolts,gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts.450 mm i/d 5 mm thickness with Epoxy |
| 49 | Providing, fabricating, supplying, lowering, laying, fixing and jointing M.S. special accessories and fittings such as bends, tees, reducers, collars, flange pipes, adaptor pieces, puddle pipes and other specials required for the pipeline system, including welding, nuts, bolts, rubber gaskets, testing and all incidental works complete in all respects as directed by the Engineer-in-Charge. |
| 50 | Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications.450 mm i/d |
| 51 | Providing and installation of 150 mm dia Double Acting Air Valve assembly in 900 mm dia MS pipeline, including 900x900x 150 mm FH Tee, 3 m long 150 mm dia double flanged MS Pipe, all fittings, all accessories, labour, machinery, tools & tackles, freight, loading, unloading and complete installation works with testing and commissioning. |
| 52 | Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. on surface and providing angle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects.150mm internal diameter |
| 53 | Providing, supplying, lowering, laying, fixing, jointing, testing and commissioning of 150 mm dia scour valve assembly comprising sluice valve, dismantling joint, M.S./D.I. specials, flanges, nuts, bolts, rubber gaskets and all other appurtenances required for complete installation, including all labour and incidental works complete in all respects as directed by the Engineer-in-Charge. |
| 54 | Providing, laying in trenches and jointing of HDPE pipes having ISI specification IS:14333, PE100, class PN-6 marked on them, make Reliance/ Hasti / Dura-Line , laying the same in trenches to correct alignment and gradients, cutting and jointing testing for water tightness and making good the leakages and defects including cost of specials complete in all respects.710mm o/d pipe |
| 55 | Providing, laying in trenches and jointing of HDPE pipes having ISI specification IS:14333, PE100, class PN-6 marked on them, make Reliance/ Hasti / Dura-Line , laying the same in trenches to correct alignment and gradients, cutting and jointing testing for water tightness and making good the leakages and defects including cost of specials complete in all respects.400mm o/d pipe |
| 56 | Providing and fixing M.S. puddle flange for HDPE pipe of 400mm diameter, fabricated from M.S. plate and welded to M.S. sleeve/collar, including cutting, welding, primer coating and embedding in concrete, complete in all respects as directed by the Engineer-in-Charge. |
| 57 | Providing and fixing M.S. puddle flange for HDPE pipe of 710mm diameter, fabricated from M.S. plate and welded to M.S. sleeve/collar, including cutting, welding, primer coating and embedding in concrete, complete in all respects as directed by the Engineer-in-Charge. |
| 58 | Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications.710mm |
| 59 | Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications.400 mm |
| 60 | Advance Direction sign board 1200x1800mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.60x0.60x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012 |
| 61 | Cement concrete 1:4:8, With stone aggregate 40mm gauge and mixing by mechanical means using concrete mixer volumetric type. |
| 62 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 63 | Centering and shuttering for columns (Square or rectangular or polygonal in plain) |
| 64 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 65 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 66 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 67 | Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines. |
| 68 | 12.5 mm thick cement plaster 1:4. (inner faces) |
| 69 | 20mm thick cement plaster 1:4 in two coat work. (outer faces) |
| 70 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish. |
| 71 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade. |
| 72 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 73 | Finishing walls with acrylic smooth exterior paint of required shade with two coats applied @ 1.67 litre/10sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm |
| 74 | Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. |
| 75 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc. |
| 76 | Laying of Dry Brick Ballast 40 mm gauge for flooring. |
| 77 | Base course of floor consisting of 100 mm thick cement concrete 1:8:16 with stone aggrigate 40 mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material. |
| 78 | Providing and laying vitrified floor tiles 600x600mm size premium quality, manufactured using Soluble Salt Technology, with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand ) for new flooring laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per sqm of tile area in average 3mm thickness over existing base etc., complete |
| 79 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 400x600 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 80 | Supply & Fixing of pressed steel frames (Chowkats) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for fixing stops, lock- notch provision for receiving tower bolts, Hydraulic spring and finished with one priming coat of approved quality, fixed in position, including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete. Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter |
| 81 | Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. Panelled, glazed or glazed and panelled (Double leaf), 40mm thick. |
| 82 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete. I.S.I Designation No. III (size of door 701mm to 850mm). |
| 83 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect |
| 84 | Providing and fixing 9” stainless steel handles ISI marked on door & window frames complete in all respect as directions of Engineer – in Charge |
| 85 | Providing and fixing 6” stainless steel tower bolts ISI marked on door & window frames complete in all respect as directions of Engineer – in Charge |
| 86 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
| 87 | Bottom Khurra on ground 1.2m x 0.6m consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3. |
| 88 | Embedding 100mm dia CI rain water non pressure ISI mark pipe in cement mortar during masonry work. |
| 89 | Providing and fixing cast iron shoe for rain water pipe on wooden plugs fixed on wall face including filling the joints with spun yarn and cement mortar 1:2. |
| 90 | Providing and fixing M.S. round or square bars at required spacing in wooden frames of windows and clearstory windows. |
| 91 | Nuts & Bolts of all sizes and length required |
| 92 | Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 93 | Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 94 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring fan point with sheet metal fan box (shape hexagonal & sheet thickness not less than 1.60 mm) in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts. |
| 95 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring light point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade. |
| 96 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring 3 pin 6 Amp. wall socket (Shuttered) point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade |
| 97 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch. |
| 98 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5sq.mm (Un-sheathed) |
| 99 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 4sq.mm (Un-sheathed) |
| 100 | Supply & erection of PVC Conduit Pipes(ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) |
| 101 | Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) size 62x37x67 cm with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 102 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. With C.P. Brass nut |
| 103 | Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect. |
| 104 | Providing and fixing in position C.P. Brass Urinal button flusher 15 mm of approved make (to the approval of Engineer-in-charge) |
| 105 | Providing and fixing C.P. brass Urinal Spreader Ocular-Regular complete with fittings for urinals complete. |
| 106 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 107 | Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect. |
| 108 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap complete in all respect. Size 450mmx300mm |
| 109 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 110mm o/d single socket SWR UPVC pipe lines laid complete |
| 110 | Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make including cutting, jointing, wastage. 75mm o/d SWR UPVC pipe lines laid complete |
| 111 | Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make including cutting, jointing, wastage. 160mm o/d SWR UPVC pipe lines laid complete |
| 112 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. SDR 11 CPVC pipes & fittings 20mm o/d. |
| 113 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. CPVC SDR 11 Pipe & fitting 25mm o/d. |
| 114 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 115 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long |
| 116 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 117 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. C.P. brass Bib cock long nose/ long body foam flow without flange. |
| 118 | Providing and fixing in position 15mm C.P. Pillar cock foam flow of approved make (to the approval of Engineer-in-charge) |
| 119 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P.brass 15mm Angle valve without flange |
| 120 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 600 mm with C.P. Brass nut |
| 121 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick, grade-304 (18/8) with waste coupling complete in all respect (Rectangular Sink with Deluxe Border Single Bowl Overall Size 555 mm x 475mm x 200 mm) |
| 122 | Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification of reputed firm of the self cleaning design with S.S. grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc. With 100mm x 75mm i/d Floor Trap (weighing 4.0 Kg) |
| 123 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber. (CSR Item No 30.99 (c)) 150mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 124 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal |
| 125 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks |
| 126 | Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball , 25mm i/d |
| 127 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size 600mmx450mm |
| 128 | Supply and erection of sheet metal SP&N Double Door Distribution Board 16 way each with IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars,earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers.As per CSR Item No 34.17 (iv) |
| 129 | Supply and erection of MCB Double Pole 40amp. (10kA, Curve-C) for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts. As per CSR Item No 34.16 A (vii) |
| 130 | Supply and erection of MCB Single Pole 6-32amp. (10kA, Curve-C) for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts.As per CSR Item No 34.16 A (ii) |
| 131 | Supply and erection of Ceiling Rose (Flush Piano type) switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc., As per CSR Item No 34.15 (xxvi) |
| 132 | Supply and erection of Bakelite Batten Holder (Large size) switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc., As per CSR Item No 34.15 (xxvii) |
| 133 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect (C) G.I. tank nipple 25mm i/d , As per CSR Item No 30.98 (c) |
| 134 | Supply of Ceiling Fan 1200 mm. |
| 135 | Erection of ceiling/cabin/exhaust fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) Cable 0.75 sqmm Complete. For Celing Fan |
| 136 | Supply of Exhaust Fan |
| 137 | Erection of ceiling/cabin/exhaust fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) Cable 0.75 sqmm Complete. Erection of Exhaust fan |
| 138 | Supply of LED Batten 20 Watt |
| 139 | Supply of LED bulb 12 watt. |
| 140 | Erection of light fixtures on wall /ceiling having connection with PVC insulated PVC sheathed two single core copper conductor (FR) Cable 0.75 sqmm Complete. Erection of 1x20/28/36/40W Box Type (LED/ Fluorescent) light fixture |
| 141 | Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 142 | Providing 12W LED Surface Ceiling Lights(Syska or Equivalent) complete in all respect. |
| 143 | Providing 36W LED Recessed Panel Light(Philips or Equivalent) complete in all respect. |
| 144 | Providing and fixing vitreous chinaware standard white Pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.Vitreous chinaware standard white pedestal for wash hand basin. |
| 145 | Cement concrete 1:8:16 with stone ballast 40mm gauge. mixing by mechanical means using concrete mixer volumetric type |
| 146 | First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth |
| 147 | First class 225mm thick honey-comb burnt brick work laid in cement sand mortar 1:4 |
| 148 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 149 | Brick Bats |
| 150 | Boring with casing pipe for tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as required such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect (a) Boring with 150mm id Housing Pipe. As per CSR Item No 28.72 (a) |
| 151 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer incharge. (a) 100 mm nominal size dia. As per CSR Item No 28.92 (a) |
| 152 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge . (a) 100 mm nominal size dia. As per CSR Item No 28.93 (a) |
| 153 | Providing, Laying, fixing & jointing of ISI Marked H.D.P.E. Pipes as per ISI - 4984-1995 casting along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. H.D.P.E pipe of 10 Kg. PE-80, 40 mm o/d. |
| 154 | Supply & erection of electrically driven water lubricated submersible pumping set should strictly confirm to ISI:8034-1976 with latest amendments, directly coupled with Submersible electric motor capable to delivering 12000 Litres of water per hour against a head of 280 ft |
| 155 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 4.0sq.mm (56/0.3mm), 3Core |
| 156 | Supply and fixing of bail plug of MS Pipe complete with inverted U-hook attached to the bottom plug complete in all respect. 100mm nominal diameter (weight 14.5 kg per metre) 5.40 mm thickness |
| 157 | Supply and fixing of well cap having thread to fix on housing pipe complete in all respect. 100mm internal diameter |
| 158 | Providing and fixing of STARTER, MAIN SWITCH/MCCB 32 AMP along with wiring etc. in cubical pillar box type panel board complete in all respects. |
| 159 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect . As per CSR Item No 28.77 |
| 160 | Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. |
| 161 | Cement concrete 1:4:8 with stone ballast 20mm gauge. mixing by manual means |
| 162 | Providing & fixing 16 gauge stainless steel pipe gate of grade 304 duly fixed at site with the help of M.S pivot & hinges grouted in cement concrete complete in all respect as per any kindof drawing & design |
| 163 | Excavation manually in trenches with straight or open cutting in built up street/ lane having wall to wall width of street/ lane upto 3.0 metre, for intramural sullage drains, extramural intercepting drains and outfall drains, storm water channels and other work contingent or incident thereto, to full dimensions and depth as shown on the drawings or as shall be required by Engineer-in-charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic. Providing and fixing and maintenance of caution boards, fencing, night signals, for leads upto 15m and for all lifts and subsequent refilling, watering and dressing upto groung level, including removal of surplus spoil from the site upto 15 metre distance complete in all respects.All classes of soil except rocky |
| 164 | 1.8 meter high G.I. barbed wire fencing with 2.4 meter angle iron posts 50x50x6mm placed every 3 meters centre to centre 0.6 meter below ground level, every 15th post, end post, corner post suitably strutted and provided with 12 horizontal lines and two diagonals interwoven with horizontal wires fixed with GI staples, turn buckles etc. including foundation concrete 1:2:4 of size 0.30x0.30x0.75m for each post complete as per technical clause 808 of MORT&H specifications |
| 165 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect b) Glazing area above 0.09 sqm, 4mm thick or 10.78 Kg/ sqm. As per CSR Item No 17.26 b (ii) |
| 166 | UNBRANDED M 35 Grade precast wall. Supply, frieght and fixing complete in all respect Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender