Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56986247

Tender For Repair / Maintenance Of Hanger Lights, Pathway Light, Bldg Security Lights And Other Connected Works And Certain B/R And E/M Repairs To Training Ditch At Af Stn Bkt

Issued by Statutory Bodies & Commissions/Committees · Lucknow, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
02 Sep 2026
18 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Hanger Lights, Pathway Light, Bldg Security Lights And Other Connected Works And Certain B/R And E/M Repairs To Training Ditch At Af Stn Bkt

BOQ

Name of Work:- REPAIR / MAINT OF HANGER LIGHTS, PATHWAY LIGHT, BLDG SECURITY LIGHTS AND OTHER CONNECTED WORKS AND CERTAIN B/R AND E/M REPAIRS TO TRAINING DITCH AT AF STN BKT
Sl. No. Item Description
1Taking out unsv LT cable of any size from trenches /duct etc carefully complete all as specified and directed .
2Supply, laying, passing through pipe, connecting & testing UG cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade of size 10 Sqm 2 core complete all as specified and directed.
3Supply, laying, passing through pipe, connecting & testing UG cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade of size 16 sq mm 2 core complete all as specified and directed.
4Excavation in trenches in soft/loose soil not.exc 1.5m wide and not exc 1.5m in depth and getting out for laying of cable/ foundation of pole & stay etc complete all as specified & directed.
5Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm in thickness in soft/loose soil complete all as specified and directed.
6Removing of surplus excavated material (SOIL) to a distance not exc 50m and depositing where directed at a level n. exc 1.5m above starting point complete all as specified and directed.
7M & L for precast cable cover class LV type 1 flat size 250mm x 150mm x 40mm laidflat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as specified and directed.
8M&L for dry sand cushioning for protection of LT underground cable including watering & consolidation complete all as specified and directed.
9Making horizontal bore hole under road suitable for 80 mm bore size at the depth not less than 1 mtr below ground level for passing of LT underground cable complete all as specified and directed.
10Dismantling and taking down carefully defective/non functional LED post top lanterrn up to 35 watt from its existing position and Supply & Fixing in repairs integrated LED type Post top lantern with high power 25/30 W LED as light source, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution,spun auminium landscape lumainaire incl LED driver complete and incl necessary electrical connection all as directed.
11Dismantling and taking down carefully defective/non functional LED post top lanterrn up to 25 watt from its existing position and S & F in repairs integrated LED type Post top lantern with high power 15/20 W LED as light source, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution,spun auminium landscape lumainaire incl LED driver complete and incl neceesary electrical connection complete all as specified and directed.
12S & F in repairs integrated LED type Bollard , 10/12 W LED as light source, IP 65, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution incl LED driver with base plate and pcc and earth work for grouting the light complete and incl neceesary electrical connection complete all as specified and directed.
13Dismantling and taking down carefully defective/non functional LED post top lanterrn up to 15 watt from its existing position and supply and fixing in repair fully cast alluminium body finished with polyurethane paint (with prior treatmen) with acrylic window cover total length up to 390 mm with B22 holder provided and spigot entry 52 mm suitable for 05 to 12 W Led Bulb and testing complete all as specified and directed.
14Dismantling and taking down carefully defective/non functional LED post top lanterrn up to 15 watt complete with bollard from its existing position and Supply , fixing and installation including excavation , concrete foundation and electrical connection in repair fully cast alluminium body finished with polyurethane paint (with prior treatment) bollard of length minimum 670 mm & Hexagonal base diameter of not less than 200 mm and max diameter of leg of bollard 75 mm surmounted with fully cast aluminium body finished with acrylic window cover provided with B22 holder with Aluminium cover suitable for 05 to 15 W Led Bulb and total length of the Bollard fitting not less than 1100 mm and testing complete all as specified and directed.
15S&F fully cast alluminium finished heavy pole designer leg and broder designer base size 270mmx270mm finished with polyurethane paint (with prior treatment)diameter of one leg is approx 88 mm outer dia for spigot entry 75 mm ,03 Nos \\"T\\" shaped bolt with nuts & washer provide cocrete foundation including earth work and PCC to fix ,total length of the pole including box and legs (Base with platex03 nos legs) is 2175 mm (7 feet 1 inches) with fully cast alluminium finished with polyurethane paint hexagonal junction box with max projection breadth of 790 mm suitable for 02 no post top latern with LED Bulb complete all as specified and directed . Make - C&S/Havells/Philips.
16S&F fully cast alluminium finished with polyurethane paint (with prior treatment) hexagonal junction with max projection breadth of 790 mm suitable for 02 Nos post top lantern for upto 3 mtr polecomplete complete all as specified and directed. Make - C&S/Havells/Philips.
17S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 10 Sqmm solid aluminium conductor complete all as specified and directed.
18S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 6 Sqmm solid aluminium conductor complete all as specified and directed.
19Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 4 Sqmm solid aluminium conductor complete all as specified and directed.
20S&F in repair twin core PVC insulated sheated (heavy duty) unarmoured alluminium conductor cable of size 2.5 sqmm for connecting light fittings with junction box, drawing through pole or GI brackets complete all as specfied and directed.
21Dismantling and taking down carefully /non functional security light from its existing position and refixing the same after repairing/replacement with new spare parts including reassembling and testing complete all as specified and directed.(Note- Spare parts componenet of security light fitting shall be measured and paid seperately under item as supply only).
22Supply only LED driver suitable for LED security light fitting as per site requirement of capacity upto 60 Watt complete all as specified and directed.
23Supply only LED driver suitable for LED flood light fitting as per site requirement of capacity upto 45 Watt complete all as specified and directed.
24S&F security light brackets made out of 25 mm dia light grade GI pipe (length of pipe should not be less than 1.2 mtr) two set of clamp made out of 25mmx3mm flat iron nut and bolt as required ,bend to shape and fixing arrangement duly welded including taking down the existing damage brackets etc complete all as specified and directed.
25S&F in repair cable junction box pole mounted thermoplastic cable junction box for security light 4.5 module with IP 65 protection ,halogen free abd weather froop with metric knocouts for cable entry for outdoor installation of approx size 126mm x 288mm x 111mm with front door opening system including terminal for one incoming and two outgoing cable of size 10/16 sqmm 2 to 4 core ,one MCB SP 3 to 6 amp 240 V AC with mounting clamp of flat iron ,nut bolt and washer completed all as specified and directed.
26Supply and fixing LED security light 45 watt , IP 66 protection complete with security light bracket (complete with two set of clamp ,nut and bolt) made out of 40 mm medium grade GI pipe bend to shape and with fixing arrangements duly welded (length of pipe should not be less than 1.2 mtrs) and making conection with using 2.5 sqmm PVC insulated multistranded copper conductor two single core cable complete all as specified and directed.
27S&F in repair LED Building security light 20/25 Watt with high power LED source (>100 lumen/watt) PDC housing, IP66 and IK 07 with 4 KV inbuilt surge protection ,minimum 50000 burning hours hv cutoff@325/440 volt protection for 8 hours including Electrical connection with PVC three core copper flexible wire & all necessary fixing accessories , completed all as specified and directed.
28S&F 30 W flood light LED fitting Warm/day cool as required, IP 65 protection, minimum 100 lumens/watt with high power LED complete with including provn of flexible three core cable from ceiling rose to fitting terminal for making electrical connection, fixing the fitting on wall including all necessary fixing accessories with nuts and bolt complete all as specified and directed.
29S&F 50 W flood light LED fitting Warm/day cool as required, IP 65 protection, minimum 100 lumens/watt with high power LED complete with including provn of flexible three core cable from ceiling rose to fitting terminal for making electrical connection, fixing the fitting on wall including all necessary fixing accessories with nuts and bolt complete all as specified and directed.
30Supply & fix in repair waterproof fountain light of 5 watt LED of different colours IP 67 protection with lumen output 250 lm complete all as specefied and directed.
31S&F in repair new LED bulb of capacity 9 watt for fixing in B-22 holder complete.
32S&F in repair new LED bulb of capacity 7 watt for fixing in B-22 holder completed all as specified and directed.
33S&F in repair frosted candle LED bulb of capacity 3 wattt for fixing in B-22 holder completed all as specified and directed.
34S&F in repairs Flexiion 15 Mtr LED strip 22 W, 3000K/6000K as required on site with driver with wide viewing angle for good light distribution, easy to install.
35Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fitting and fixture and such as as switches, sockets ceiling rose,pendent holders,regulators,light fittings any type removing materials to store in safe custody or for credite etc, completed all as specified and directed.
36M&L for point wiring with two single core PVC insulated & PVC unsheathed FRLS-H multistranded copper conductor cable of size 1.5 sqmm 1100 volt grade in and including making good the disturbed surface of wall with colour washing /distempering the surface to match the existing one and drawan into and including non metallic rigid PVC conduit medium grade 2 mm thick medium 20/25 mm dia with all accessories mounting all the surface of wall/ceiling/roof/etc with suitable size of 1 to 8 module metal flush boxes and including modular front cover plate & back plate for mounting modular type switches /socket/fan/ regulator etc including provision of one single core PVC insulated and unsheathed multi stranded FRLS-H copper cable of size 1.5 sqmm 1100 volt grade as earth continuty conductor connected to common earth dolly switch board complete all as specified and directed.One light/fan point controlled by one switch.
37Ditto all as per item No 36 above but one socket outlet point 5 Amp on an independent board.
38Ditto all as per as item No 36 aobve but on the same board
39Ditto all as item No 36 herein before but using 2.5 sqmm , PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board.
40M&L for flame proof point wiring with two single core FRLS-H PVC insulated & PVC unsheathed stranded copper conductor cable of size 1.5 Sqmm 1100 volts grade in and including stove enamelled steel cocealled/surface conduit of size 20 to 25 mm with all accessories and one single core PVC insulated & PVC sheathed solid FRLS-H copper cable of size 1.5 Sqmm 1100 Volts grade as earth continuity conductor connected to common earth dolly, switch board complete incuding making good the disturbed surface all as specified for one light point controlled by one 5 Amps switch/mcb one way complete.
41M&L switch flame proof rotory type with termination box in LM 6, 16, single phase 250 volts, complete all as specified and directed.
42S&F modular switch single pole, one way 5 Amps. complete all as specified and directed.
43S&F switch modular type 1 module single pole, one way 15 Amps. complete all as specified and directed.
44S&F s socket outlet 2 in 1, 5 pin, 15 Amps modular type 2 module, complete all as specified and directed. .
45S&F socket outlet 5 Amps modular type 2 module complete all as specified and directed.
46S&F ceiling Rose, surface, bakelite 65mm x 50 mm three terminals, AC, 230 Volts completed all as specified and directed.
47S&F in repair LED Light Fitting 1x16 Watt flame proof ,CMRI certified recommended for gas/vapour group of IIA &III B ,zone 1 and 2 and IP 65 Protection with die cast alluminium housing with heat resistant toughned glass with LED tube light, fixtures, driver holders ,connectors etc complete with all accesories prewired and including connecting with three core flexible copper conductor cable with suitable size complete all as specified and directed.
48Taking down old unserviceable main switches/DB’s up to 100 Amps capacity fixed in wall and making good of all disturbed surfaces as per existing.
49S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 4 way, AC,240 volt with 200 Amp bus bar rating completed all as specified and directed.
50S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 8 way, AC,240 volt with 200 amp bus bar rating completed all as specified and directed.
51S&F MCB DP 40 to 63 Amps 240 Volts, 50 Hz, 10 KA breaking capacity completed all as specified and directed.
52S&F MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity completed all as specified and directed.
53M&L for submain wiring with two run of single core PVC insulated unsheathed multi stranded FRLS-H copper conductor cable of size 2.5 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistarnded copper conductor cable of size 2.5 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid PVC concealed conduit of suitable size 20 /25 mm on roof/wall/ceiling including making good the disturbed surfaces of wall etc completed all as specified and directed. Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the quoted unit rate for this item).
54S&F Submain wiring with two single core PVC insulated FRLS-H multistrand copper conductor cable of size 04 Sq mm drawn into and including non metallic medium duty rigid concealed PVC condute not less than 25 mm size ISI marked with all fittings / accessories and 04 Sq mm FRLS-H multistrand copper conductor cable as continuous earth wire completed all as specified and directed. Make-Polycab/Finolex/Plaza/RR Kabels or equivalent (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate quoted for this items).
55S&F in repair adjustable brass gushing water fountain nozzle of size upto 10 mm ,with fitting and fixture all as specified and directed.
56S&F modular type AC box with socket plug top and MCBs with two pin and one pin for earth plug and socket complete with one single pole MCB 20 Amp completed all as specified and directed.
57Supply , installation , testing & commissioning of IP-68 rated , submersible LED fountain light / fountain luminaire of 10 Watt complete with submersible driver , SS -316 body , toughned glass , cable gland & 3-core 2.5 sqmm submersible PVC copper cable of 5 mtr length & shall be suitable for continous underwater operation in fountain pond complete all as specified and directed.
58S&F decorative wall light , gold finish fixture with white glass diffusser suitable for 1x7/1x9 watt LED bulb completed all as specified and directed.
59S&F brilliante linear wall washer light crafted from aluminium die cast with Bi- Directional Beam with integrated LED with IP 65.
60S&F premium category spotlight with compact design ,LED Azstro COB Module Grey 7.5 W 4000 K complete all as specified and directed.
61Supply & fix footlight LED based with chrome collar modular type of 4 module glossy finish 230 volt, 50 Hz complete all as specified and directed. Please Enable Macros to View BoQ information
62Supply & fix footlight LED based with chrome collar modular type of 4 module glossy finish 230 volt, 50 Hz complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56986247
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 02-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Hanger Lights, Pathway Light, Bldg Security Lights And Other Connected Works And Certain B/R And E/M Repairs To Training Ditch At Af Stn Bkt
Basic Detail
Tender No 8897/BKT/E8
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 13 Aug 2026
Submission Date 02 Sep 2026
Open Date 05 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 90000
Exemption Not Available
Document List
8897credit.pdf
8897tenderdocuments.pdf
BOQ_878721.xls
d18a976e-90ca-4a67-9f0d-4e369d1ec3e0.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
pdf

8897credit.pdf

pdf

8897tenderdocuments.pdf

xls

BOQ_878721.xls

html

d18a976e-90ca-4a67-9f0d-4e369d1ec3e0.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail