Project Description

Tender for Special Repair Of Existing Lt Panels & Improvement In Connected Accessories At Ramgarh Under Ge (Af) Jaisalmer

BOQ

Name of Work:- SPECIAL REPAIR OF EXISTING LT PANELS & IMPROVEMENT IN CONNECTED ACCESSORIES AT RAMGARH UNDER GE (AF) JAISALMER
Sl. No. Item Description
1Supply, installation, testing & commissioning in replacement of LT panel Outdoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet with Rain Canopy and Outlet filter with Hood, factory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 400 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25 x 6 mm with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as specified and directed :- NOTES: [i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T or equivalent as approved by GE.(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item)Location : HQ Main PanelIncoming :(a) MCCB 250 Amp 415 Volts, 36 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release -01 NoOutgoing :(a) MCCB 160 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No(b) MCCB 125 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No(c) MCCB 100 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No(d) Digital Voltmeter 0-500 Volts with inbuilt selector switch -01 No (e) Digital Amp meter 0-250 Amp with inbuilt selector switch -01 No (f) Indicating Light RED 220V AC -01 No(g) Indicating Light Yellow 220V AC -01 No(h) Indicating Light Green 220V AC -01 No(j) Protection MCB 6 Amp SP-03 Nos (k) CT 250/5A-03 Nos (l) Automatic Phase Sequence Corrector -01 No (m) Danger Plate-01 No (n) Enclosure of Suitable Size
2Supply, installation, testing & commissioning in replacement of LT panel Outdoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet with Rain Canopy and Outlet filter with Hood, factory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 400 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25 x 6 mm with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as specified and directed :- NOTES: [i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T or equivalent as approved by GE. (Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item)Location : L/In Billet (Front side)Incoming :(a) MCCB 250 Amp 415 Volts, 36 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release -01 No.Outgoing :(a) MCCB 160 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No(b) MCCB 100 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-02 Nos(c) Digital Voltmeter 0-500 Volts with inbuilt selector Switch -01 No (d) Digital Amp meter 0-250 Amp with inbuilt selector Switch -01 No (e) Indicating Light RED 220V AC-01No(f) Indicating Light Yellow 220V AC-01No(g) Indicating Light Green 220V AC-01No(h) Protection MCB 6 Amp SP-03 Nos (j) CT 250/5A-03 Nos(k) Automatic Phase Sequence Corrector -01No (l) Danger Plate-01 No (m) Enclosure of Suitable Size
3Supply, installation, testing & commissioning in replacement of LT panel Outdoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet with Rain Canopy and Outlet filter with Hood, factory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 200 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25 x 6 mm with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as specified and directed :- NOTES: [i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T or equivalent as approved by GE.(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item)Location : Gym (Front side)Incoming :(a) MCCB 160 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release -01 No.Outgoing :(a) MCCB 100 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No.(b) MCCB 63 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-02 Nos.(c) Digital Voltmeter 0-500 Volts with inbuilt selector Switch -01 No (d) Digital Amp meter 0-200 Amp with inbuilt selector switch -01 No (e) Indicating Light RED 220V AC-01 No (f) Indicating Light Yellow 220V AC-01 No (g) Indicating Light Green 220V AC-01 No (h) Protection MCB 6 Amp SP-03 Nos (j) CT 160/5A-03 Nos (k) Automatic Phase Sequence Corrector-01 No(l) Danger Plate -01 No(m) Enclosure of Suitable Size
4Supply, installation, testing & commissioning in replacement of LT panel Outdoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet with Rain Canopy and Outlet filter with Hood, factory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 250 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25 x 6 mm with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as specified and directed :- NOTES: [i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T or equivalent as approved by GE.(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item)Location : Near Guest Room No : 01Incoming :(a) MCCB 160 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release -01 No.Outgoing :(a) MCCB 125 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No.(b) MCCB SPN 32-40 Amp 240 Volts, 10 KA, C curve - 02 Nos(c) MCCB TPN 32 Amp 415 Volts, 10 KA, C curve - 01 No(d) Digital Voltmeter 0-500 Volts with inbuilt selector switch -01 No(e) Digital Amp meter 0-150 Amp with inbuilt selector switch -01 No (f) Indicating Light RED 220V AC-01 No (g) Indicating Light Yellow 220V AC-01 No (h) Indicating Light Green 220V AC-01 No (j) Protection MCB 6 Amp SP-03 Nos (k) CT 160/5A-03 Nos (l) Automatic Phase Sequence Corrector -01 No (m) Danger Plate-01 No (n) Enclosure of Suitable Size
5Supply, installation, testing & commissioning in replacement of LT panel Outdoor type, CPRI All type test certificate and Design Verification with switchgears (MCB/MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet with Rain Canopy and Outlet filter with Hood, factory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 50 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25 x 6 mm with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as specified and directed :- NOTES: [i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T or equivalent as approved by GE.(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item)Location : Parade GroundIncoming :(a) MCCB TPN 32 Amp 415 Volts, 10 KA, C curve, - 01 NoOutgoing :(a) MCB SPN 32 Amp 240 Volts, 10 KA, C curve - 06 Nos(b) Digital Voltmeter 0-500 Volts with Selector Switch -01 No (c) Digital Amp meter 0-50 Amp with Selector Switch -01 No(d) Indicating Light RED 220V AC-01 No (e) Indicating Light Yellow 220V AC-01 No (f) Indicating Light Green 220V AC-01 No (g) Protection MCB 6 Amp SP-03 Nos (h) CT 32/5A-03 Nos (j) Automatic Phase Sequence Corrector -01 No(k) Danger Plate-01 No (l) Enclosure of Suitable Size
6Supply, installation, testing & commissioning in replacement of LT panel Outdoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet with Rain Canopy and Outlet filter with Hood, factory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 250 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25 x 6 mm with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as specified and directed :- NOTES: [i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T or equivalent as approved by GE.(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item)Location : Sargent BlockIncoming :(a) MCCB 160 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No.Outgoing :(a) MCCB 125 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No.(b) MCCB 100 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No.(c) MCB TPN 32 Amp 415 Volts, 10 KA, C curve - 01 No(d) MCB TPN 40 Amp 415 Volts, 10 KA, C curve - 01 No(e) Digital Voltmeter 0-500 Volts with Selector Switch - 01 No(f) Digital Amp meter 0-150 Amp with Selector Switch - 01 No(g) Indicating Light RED 220V AC- 01 No(h) Indicating Light Yellow 220V AC- 01 No(j) Indicating Light Green 220V AC- 01 No(k) Protection MCB 6 Amp SP- 03 Nos(l) CT 160/5A- 03 Nos(m) Automatic Phase Sequence Corrector -01 No (n) Danger Plate-01 No (o) Enclosure of Suitable Size
7Supply, installation, testing & commissioning in replacement of LT panel Outdoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3.15 mm thick CRCA sheet with Rain Canopy and Outlet filter with Hood, factory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged double door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 250 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25 x 6 mm with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as specified and directed :- NOTES: [i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T or equivalent as approved by GE.(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item)Location : Parameter PanelIncoming :(a) MCCB 125 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release -01 No.Outgoing :(a) MCCB 100 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No.(b) MCCB 63 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No.(c) Digital Voltmeter 0-500 Volts with inbuilt selector Switch -01 No (d) Digital Amp meter 0-150 Amp inbuilt selector Switch -01 No (e) Indicating Light RED 220V AC-01 No (f) Indicating Light Yellow 220V AC-01 No (g) Indicating Light Green 220V AC-01 No (h) Protection MCB 6 Amp SP-03 Nos (j) CT 125/5A-03 Nos (k) Automatic Phase Sequence Corrector -01 No(l) Danger Plate-01 No (m) Time switch astro type (having longitude and latitude of Indian cities in memory) 415 Volt three phase of 20 Amp rating with contactor fitted inside steel enclosure - 01 No.(n) Enclosure of Suitable Size
8Supply, installation, testing & commissioning in replacement of LT panel Indoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 2.00 mm thick CRCA sheet factory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 150 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25 x 6 mm with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as specified and directed :- NOTES: [i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T or equivalent as approved by GE.(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item)Location : Pump House PanelIncoming :(a) MCCB 100 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No.Outgoing :(a) MCCB 32 Amp 10 KA SPN 'C' Curve-03 Nos (b) MCCB 16 Amp 10 KA SPN 'C' Curve-02 Nos (c) Digital Voltmeter (0-500 V) with Selector Switch-01 No(d) Digital ammeter (0-100 A) with Selector Switch-01 No (e) Indicating Light RED 220 V AC-01 No (f) Indicating Light Yellow 220 V AC-01 No (g) Indicating Light Green 220 V AC-01 No (h) Protection MCB 6 Amp SP-03 Nos (j) CT 100/5A-03 Nos (k) MPCB 22-32 Amp 415 Volts, 50 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release - 02 Nos Fully automatic Star Delta Starter 15 HP (Centrifugal Pumpset):- (i) Power Contactor 22 A TP (Main & Delta) -04 Nos (ii) Power Contactor 18 A TP (Star) -02 Nos (iii) Bi metal over load relay 9-15A -02 Nos (iv) Star Delta timer Micon Series -02 Nos (v) Aux. Blocks -06 Nos (vi) Push Button Start / Stop 220 V -04 Nos (vii) Auto manual Selector Switch -02 Nos (viii) Indicating light on/off/trip 220 V-06 Nos (ix) Control MCB SP 6 A 10 KA-02 Nos (x) Single Phase Preventer-02 Nos (xi) Digital ammeter with Selector switch -02 Nos (l) Automatic Phase Sequence Corrector-01 No (m) CT 100/5A-03 Nos(n) Danger Plate-01 No (o) Enclosure of Suitable Size
9Supply, installation, testing & commissioning in replacement of LT panel Indoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 2.00 mm thick CRCA sheet factory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 1000 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25 x 6 mm with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as specified and directed :- NOTES: [i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T or equivalent as approved by GE.(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item)Location : Power House PanelIncoming :(a) MCCB 630 Amp 415 Volts, 36 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No.Outgoing :(a) MCCB 250 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No(b) MCCB 125 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-03 Nos(c) MCCB TPN 32-40 Amp 415 Volts, 10 KA, C curve - 4 Nos(d) MCCB SPN 32 Amp 240 Volts, 10 KA, C curve - 02 Nos(e) Digital Voltmeter 0-500 Volts with Selector Switch -01 No (f) Digital Amp meter 0-600 Amp with Selector Switch -01 No (g) Indicating Light RED 220V AC-01 No (h) Indicating Light Yellow 220V AC-01 No(j) Indicating Light Green 220V AC- 01 No(k) Protection MCB 6 Amp SP-03 Nos(l) CT 630/5A-03 Nos (m) Automatic Phase Sequence Corrector -01 No (n) Time switch astro type (having longitude and latitude of Indian cities in memory) 415 Volt three phase of 20 Amp rating with contactor fitted inside steel enclosure - 01 No.(o) Danger Plate-01 No (p) Enclosure of Suitable Size
10Supply, installation, testing & commissioning in replacement of LT panel Indoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 2.00 mm thick CRCA sheet factory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 150 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25 x 6 mm with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as specified and directed :- NOTES: [i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T or equivalent as approved by GE.(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item)Location : RO Plant Panel (Motor Starter Panel)Incoming :(a) MCCB 125 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release -01 No.Outgoing :(a) MCCB 100 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No(b) MCCB 63 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No(c) Digital Voltmeter (0-500 V) with Selector Switch -01 No (d) Digital ammeter (0-100 A) with Selector Switch-01 No (e) Indicating Light RED 220 V AC-01 No (f) Indicating Light Yellow 220 V AC-01 No (g) Indicating Light Green 220 V AC -01 No(h) Protection MCB 6 Amp SP -03 Nos (j) CT 125/5A-03 Nos DOL Starter 2 HP (Monoblock pumpset) (i) Power Contactor 9 Amp TP -02 Nos (ii) Bi metal over load relay 3-5A-02 Nos (iii) Star Delta timer Micon Series -02 Nos (iv) Aux. Blocks-02 Nos (v) Push Button Start / Stop 220 V-04 Nos (vi) Auto manual Selector Switch-02 Nos (vii) Indicating light on/off/trip 220 V-06 Nos (viii) Control MCB SP 6 A 10 KA-02 Nos (ix) Single Phase Preventer-02 Nos (k) Automatic Phase Sequence Corrector -01 No(l) CT 125/5A -03 Nos (m) Danger Plate-01 No(n) Enclosure of Suitable Size
11Supply, installation, testing & commissioning in replacement of LT panel Indoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 2.00 mm thick CRCA sheet factory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 150 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25 x 6 mm with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as specified and directed :- NOTES: [i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T or equivalent as approved by GE.(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item)Location : IGNP Panel (Motor Starter Panel)Incoming :(a) MCCB 100 Amp 415 Volts, 25 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release-01 No (b) Change Over Switch 63 Amps -01 NoOutgoing :(a) MPCB 40-50 Amp 415 Volts, 50 KA, 4 pole, 50 Hz, with adjustable thermal magnetic release - 02 Nos (b) MCCB SPN 32 Amp 240 Volts, 10 KA, C curve - 02 Nos(c) Digital Voltmeter (0-500 V) with Selector Switch -01 No(d) Digital ammeter (0-250 A) with Selector Switch -01 No(e) Indicating Light RED 220 V AC-01 No(f)Indicating Light Yellow 220 V AC-01 No(g) Indicating Light Green 220 V AC-01 No (h) Protection MCB 6 Amp SP-03 Nos (j) CT 63/5A -03 NosStar Delta Starter 20 HP (Centrifugal Pumpset)(i) Power Contactor 25 A TP (Main & Delta)-04 Nos (ii) Power Contactor 22 A TP (Star)-02 Nos (iii) Bi metal over load relay 14-23A -02 Nos (iv) Star Delta timer Micon Series -02 Nos (v) Aux. Blocks-06 Nos (vi) Push Button Start / Stop 220 V-04 Nos (vii) Auto manual Selector Switch-02 Nos (viii) Indicating light on/off/trip 220 V-06 Nos (ix) Control MCB SP 6 A 10 KA-02 Nos (x) Single Phase Preventer-02 Nos (xi) Digital ammeter with Selector switch -02 Nos (k) Automatic Phase Sequence Corrector-01 No (l) CT 63/5A-03 Nos(m) Danger Plate-01 No (n) Enclosure of Suitable Size
12Supply, installation, testing & commissioning in replacement of APFC panel Indoor type, CPRI All type test certificate and Design Verification with switchgears (MCCB) conforming to IS/IEC: 61439/2011 Part-1 & 2 shall be submitted by the contractor before execution of work, weather/vermin proof, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 2.00 mm thick CRCA sheet factory assembled cubicle pattern modular and compartmentalized construction with front and backside hinged door with locking arrangement, floor mounted free standing type with Angle iron of size 50 x 50 x 6 mm, provided with gasket for all the doors & removable covers, duly powder coated, 3 phase and neutral 200 Amps current carrying capacity aluminium bus bar with heat shrinkable PVC sleeve insulated coating with colour code and insulated support with aluminium earth bus of size 25 x 6 mm with inter connecting bus bar connection comprising of following switch gears and mounting panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level connecting existing LT Cables with panel board complete all as specified and directed :- NOTES: [i] The Panel shall be purchased from the (OEM) / authorized license partner of the OEM i.e. ABB, Siemens, Havells, L&T or equivalent as approved by GE.(Note: LT Panel shall be mounted on floor with suitable size fasteners and cost of the same shall be deemed to be included in the unit rate quoted for the item)(01) Incoming MCCB 160 Amps 25 KA 4 Pole Adjustable thermal & fixed magnetic setting Ics=100% of Icu Make L&T/Legrand/Siemens or equivalent as approved by GE - 01 No (02) Microprocessor based Power factor corrector relay 6 stage Make L&T/Trinity/Epcos or equivalent as approved by GE -01 No.(03) Capacitor duty contactor for 25 KVAR, Make: L&T/Legrand/Siemens or equivalent as approved by GE - 01 No (04) Capacitor duty contactor for 20 KVAR, Make: L&T/Legrand/Siemens or equivalent as approved by GE- 02 Nos. (05) Capacitor duty contactor for 15 KVAR, Make: L&T/Legrand/Siemens or equivalent as approved by GE- 01 No. (06) Capacitor duty contactor for 10 KVAR, Make: L&T/Legrand/Siemens or equivalent as approved by GE- 01 No. (07) Capacitor duty contactor for 05 KVAR, Make: L&T/Legrand/Siemens or equivalent as approved by GE- 01 No (08) Power Capacitor 5 KVAR heavy duty fixed with bus bar with MCB 16 A TP -1 No Make:- L&T/Legrand/Epcos or equivalent as approved by GE. (09) MCB 63 A,10 KA TP C Curve Make:L&T/Legrand/Siemens or equivalent as approved by GE - 01 No. (10) MCB 40 A,10 KA TP C Curve Make:L&T/Legrand/Siemens or equivalent as approved by GE - 02 Nos. (11) MCB 32 A,10 KA TP C Curve Make:L&T/Legrand/Siemens or equivalent as approved by GE - 01 No. (12) MCB 25 A,10 KA TP C Curve Make:L&T/Legrand/Siemens or equivalent as approved by GE - 01 No. (13) MCB 16 A,10 KA TP C Curve Make:L&T/Legrand/Siemens or equivalent as approved by GE - 01 No. (14) Auto Manual Selector Switch, 6A 1 Pole Make: L&T/Legrand/Schneider or equivalent as approved by GE or equivalent as approved by GEor equivalent as approved by GE- 6 Sets
13(15) Indicating light LED type ON, 220 V AC Make: L&T/Schneider/Vaishno or equivalent as approved by GE-6 Sets. (16) Panel Cooling Fan 4\\" - 2 Nos. with thermostat - 01 No.(17) Power capacitor 25 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, 01 No.(18) Power capacitor 20 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, 02 Nos.(19) Power capacitor 15 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, 01 No.(20) Power capacitor 10 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, 01 No.(21) Power capacitor 5 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, 01 No.Make: L&T/Legrand/Epcos or equivalent as approved by GE(22) Digital Voltmeter 0-500 V 96x96 mm Make: L&T/Legrand/Siemens or equivalent as approved by GE-01 set.(23) Digital Ammeter 0-200 Amps 96x96 mm Make: L&T/Legrand/Siemens or equivalent as approved by GE- 01 set.(24) Volt Meter Selector Switch 6 A , Make: L&T/Legrand/Siemens or equivalent as approved by GE- 01 No.(25) Amps Meter Selector Switch 6 A , Make: L&T/Legrand/Siemens or equivalent as approved by GE- 01 No.(26) C.T. of ratio 200/5 amps 5 VA Class-1.0 -03 Nos Make: Trinity/ AE/L&T or equivalent as approved by GE(27) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three). L&T/ABB/Schneider or equivalent as approved by GE.(28) Protection MCB 6 Amps SP Make: L&T/ABB/Legrand or equivalent as approved by GE - 05 Nos. Please Enable Macros to View BoQ information
14(15) Indicating light LED type ON, 220 V AC Make: L&T/Schneider/Vaishno or equivalent as approved by GE-6 Sets. (16) Panel Cooling Fan 4\\" - 2 Nos. with thermostat - 01 No.(17) Power capacitor 25 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, 01 No.(18) Power capacitor 20 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, 02 Nos.(19) Power capacitor 15 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, 01 No.(20) Power capacitor 10 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, 01 No.(21) Power capacitor 5 KVAR heavy duty dry type having tolerance 0% -10% with discharge device resistor, 01 No.Make: L&T/Legrand/Epcos or equivalent as approved by GE(22) Digital Voltmeter 0-500 V 96x96 mm Make: L&T/Legrand/Siemens or equivalent as approved by GE-01 set.(23) Digital Ammeter 0-200 Amps 96x96 mm Make: L&T/Legrand/Siemens or equivalent as approved by GE- 01 set.(24) Volt Meter Selector Switch 6 A , Make: L&T/Legrand/Siemens or equivalent as approved by GE- 01 No.(25) Amps Meter Selector Switch 6 A , Make: L&T/Legrand/Siemens or equivalent as approved by GE- 01 No.(26) C.T. of ratio 200/5 amps 5 VA Class-1.0 -03 Nos Make: Trinity/ AE/L&T or equivalent as approved by GE(27) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three). L&T/ABB/Schneider or equivalent as approved by GE.(28) Protection MCB 6 Amps SP Make: L&T/ABB/Legrand or equivalent as approved by GE - 05 Nos. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56986238
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.52 Lakhs
LAST DATE 02-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair Of Existing Lt Panels & Improvement In Connected Accessories At Ramgarh Under Ge (Af) Jaisalmer
Basic Detail
Tender No 8470/GE/E8
Bidding Type Tender
Location
City Jaisalmer
State Rajasthan
Key Dates
Publish Date 13 Aug 2026
Submission Date 02 Sep 2026
Open Date 04 Sep 2026
Finance
Tender Value 47.52 Lakhs
Tender Fee 500
EMD 95040
Exemption Available
Document List
8470tenderdocu.pdf
BOQ_878717.xls
c7011274-f196-4dd7-945e-64398a22f9cb.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Sep 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

8470tenderdocu.pdf

xls

BOQ_878717.xls

html

c7011274-f196-4dd7-945e-64398a22f9cb.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders