Tender For Special Repair To Roof Sheet, Truss And Certain Other Wks At Otm Accn At 6003 Wksp Under Mil Stn Kaluchak Under Ge Kaluchak.
Tender Value
28.67 Lakhs
Estimated cost
Bid Submission
03 Sep 2026
10 days left
EMD
57400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kaluchak → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Roof Sheet, Truss And Certain Other Wks At Otm Accn At 6003 Wksp Under Mil Stn Kaluchak Under Ge Kaluchak.
BOQ
| Sl. No. | Item Description |
| 1 | Taking out carefully copper/aluminium point wiring,Light,fan,socket or power complete with all fitting, fixtures such as switch socket out let, ceiling rose ,holder ,regulator,DBs etc including making good the disturbed surface of wall/floors complete all as specified and as directed. |
| 2 | Taking down distribution boards/wooden board ,switch fuse units,steel enclosures for MCB of any type and removing from site all as specified and as directed. |
| 3 | Taking down existing unserviceable submain wiring any size and making good the disturbed surface all as specified and as directed. |
| 4 | Dismentaling &Taking down unserviceable Bldg street light/Flood light fittings from pole or from Bldgs for replacement of unserviceable lights from junction boxes to light fitting all as specified and as directed. |
| 5 | M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid/ 1.8mm wall thickness ISI marked including Modular Metal flush Boxes of any way i.e. (1 to 8 way as per site requirement) with suitable outer plates for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :- Note: suitable Modular white cover sheets with frame as specified to be provided in replacement to MS/Galvanised sunken boxes and measured & paid separately as per relevant item.Note : (a) wiring shall be done by using proper colour coding including making disturb surface good(b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge. |
| 6 | All as per item No 05 here in above but 5 Amp socket outlet on same board. complete all as specified and as directed. |
| 7 | All as per item No 05 here in above but socket outlet 5 Amps independent board complete all as directed. |
| 8 | All as per Item no 05 here-in-before but for one15 Amp 6 pin switch socket outlet, independent with 2.5 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed. |
| 9 | S&F Modular switch 1 way 6A,1 module , 240 volts ISI marked complete all as specified and directed |
| 10 | S&F Modular switch 1 way 16A, 1 module , 240 volts ISI marked complete all as specified and directed |
| 11 | S&F Modular Socket, 6A - 3 pin combined 2 module, , 240 volts ISI marked complete all as specified and directed |
| 12 | S&F Modular Socket 6A/16A - 5 pin combined 2 module, , 240 volts ISI marked complete all as specified and directed |
| 13 | S&F Ceiling Rose 3 terminal surface type Complete all as directed. complete all as specified and as directed. |
| 14 | S&F for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and directed. |
| 15 | S&F LED Bulb cool white 10 Watt Elegant design direct fit for easy installation all as specified and directed. |
| 16 | S&F Modular Fan step regulator, 120W 1 module , 240 volts ISI marked complete all as specified and directed |
| 17 | S&F LED lights fitting 1x 20W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95 , SPD 2.5 KV, 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz. complete all as specified and as directed. |
| 18 | Supply and fixing factory made epoxy powder coated Distribution board SPN 8 ways (SPN MCB DB) with metal door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 100 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cale management, top and bottom removable gland plates with Knockouts and suitable for one SPN/DP-MCB as incomer and SP MCBs outgoing complete all as specified and confirming to IS : 8623. |
| 19 | Supply and fix MCB SP-06 to 32 Amp,10KA,B curve, 240 volts complete all as specified and as directed. |
| 20 | Supply and fix of MCB SPN 32 Amp,B curve, 240 volts 50Hz AC supply, complete all as specified and as directed. |
| 21 | M&L in repairs for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 6 Sqrmm for phase and neutral and one run of 6.0 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. complete all as specified and as directed.Note : Wiring shall be done in proper colour coding. |
| 22 | Repair and fixing of ceiling fan complete with blades, and accessories obtained vide with provision of new anti suicide fan rod(Suitable size and length and oiling/greasing of fan with provision of flexiable cable twin core all as reqd at site all as specified and directed. |
| 23 | Taking down Geyser any cap/type including disconnection electrically and refixing at same or new location with and including 2 nos PVC connection for inlet/outlet pipe, thermostate & indicator lamp as required at site as specified and directed. |
| 24 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and as directed.complete all as specified and directed. |
| 25 | M&L for cutting of suitable size of holes for 300 mm exhaust fan in wall and grouting of nuts and bolts in wall and making good to match with existing walls all as specified and directed. |
| 26 | M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to GI earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dia and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) and pouring extra Clay Soil of qty not less than one cubic meter into the earth pit and also removal of excavated soil not less than 50 mtr from the earthing place all as specified and directed and tested on completion. including testingall as specified and directed. |
| 27 | Supply and fixing LED Bldg security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with suitable size and length of 1.5 sqmm copper conductor with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 28 | Taking Down old U/S XLPE 1100 volts grade of size 25 sqmm 2 core.complete all as specified and as directed. |
| 29 | Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 2 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and directed. |
| 30 | Excavation in trenches not exceeding 1.5 metres wide and not exceeding1.5 metres in depth and getting out in any type of soil complete all as specified and as directed. |
| 31 | Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer complete all as specified and as directed. |
| 32 | Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 33 | M&L Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches complete all as specified. |
| 34 | S & F Steel pipe glavanized grade of 40 mm core laid in trenches or under ground/floor or road of fixed with pole for protection of cable including clams with bolts nuts and wasers complete ass as specifed. |
| 35 | M&L Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brick. complete all as specified and as directed. |
| 36 | S&F GI Tubing medium grade 20 mm dia with all fittings and fixed complete to laid in trenches complete all as specified and directed. |
| 37 | Excavation in trenches, n. exc1.5 m wide and n. exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 sq m on plan and n. exc1.5 m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 38 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and as directed. |
| 39 | Removing Excavated soils to a distance exceeding 50 M but not exceeding 500 M and depositing where directed at a level not exceeding 1.5m above from the starting point complete all as specified and as directed. |
| 40 | S&F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 41 | Cutting existing 100/150 mm GI pipe and inserting Nipple of 25mm bore with socket and union for tapping including necessary earth work and making flange for connection of new 80 mm of GI pipe including all as specified and directed. |
| 42 | Taking down chowkhats or frames ( without taking down shutters from the frame) not exceeding 1.5 sqm each . complete all as specified and as directed. |
| 43 | Taking down chowkhats or frames (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and as directed. |
| 44 | S & F in 30mm thick flush shutters solid core constructions with block board core any plywood face panels commercial type on both face is covered with decorative face veneer with lipping/frame to match. complete all as specified and as directed. |
| 45 | M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregates as in anchoring hold fast, parapets, coping, apex plates, bed plates and the like including weathering slightly rounded or chamfered angles and throating etc. complete all as specified and directed. |
| 46 | S&F Box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick MS sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass panes will be measured and paid seperately) with side hung shutters with MS handles and MS peg stay dovetailed or welded incl 02 Nos, MS Tower bolts 150 mm long for each leaf and 8 mm square bar grill / guard bars at spacing as shown on Drg welded to MS flat iron frame work ,including other fittings ,hinges ,MS handles ,tarred hold fasts ,PCC blocks for hold fasts etc all as shown on Drg No CEPZ/CE -TD/031/2013 SHEET NO 142 including one coat of red oxide zinc primer, complete all as specified and directed |
| 47 | M & L for Aluminium anodised powder coated window/ventilator shutter, section of size 44.45 x 44.45mm made out of 1.6mm thick aluminium sheet/section including necessary jointing cleats, glazing clips, 4.0 mm thick coloured or tinted glass, rubber packing, suitable handle & powder coated hookes and eye , tower bolt ( 1 number each shutter), hinges 110mm long, anodised aluminium snap beading screws, complete all as specified and directed.Note :The item shall be included as following :-(a) 4.0 mm thick coloured or tinted glass glazing as in aluminium window/ ventilator with aluminium hollow beading/ glazing clip(b) Powder coated Aluminium hardware fittings as described above. |
| 48 | S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws@200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge |
| 49 | S&F of 5.5mm thick glass with solar control film 50micron reflective type sticed to glass panes as per instructins of manufacturersas in aluminium door with aluminium hollow beading/glazing clip (included with shutters) including rubber gasket, complete,all as specified & directed |
| 50 | S&F Butt hinges, medium weight, cold rolled mild steel, 100 mm size, complete all as specified and as directed. |
| 51 | S&F Aluminium alloy sliding door bolt, 300 mm,anodized with hasp, staple (bolt type) and fixing clips of sheets,bolts and sliding bolts of extruded sections. complete all as specified and as directed. |
| 52 | S&F Aluminium anodized barrel tower bolt of extruded section and fixed complete of size 150mm long complete all as specified and as directed. |
| 53 | S&F Aluminium handle cast type anodized of size 150mm complete all as specified and as directed. |
| 54 | S&F Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples. complete all as specified and as directed. |
| 55 | S&F Sheet glass, ordinary quality, 3mm thick and glazed with oil putty or wooden beads, in square n exc. 0.5 Sq m each pane, complete all as specified directed. |
| 56 | Demolition of brick work masonry built in cement mortar including all quoins, pillars etc. but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and as directed. |
| 57 | M&L Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6 but except brick i.e. using serviceable bricks obtained from Srl item No. 15 here-in-before, complete all as specified & directed. |
| 58 | M&L Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed. |
| 59 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dustetc including brushing neat cement slurry with 3.0kg of cement per Sq. Metre complete all as specified and as directed. |
| 60 | M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid over & including 15 mm thick screed base in CM 1:6, jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirror finish with machine, complete all as specified and as directed. |
| 61 | M&L Machine cut Kota stone slab not less than 19mm thick as in riser of steps, skirting, dado and pillar laid over & including 15 mm thick screed base in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirror finish with machine, complete all as specified and as directed. |
| 62 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 63 | Demolition of cement concrete ( un reinforced ) in ground floors and paving n exc. 15 cm. Thickness, below or above ground level . complete all as specified and as directed. |
| 64 | M&L for 75mm thick, plain cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection etc., finishing surface even and smooth without using extra cement including making joints with bitumastic filling in proportion of bitumen and sand 1:3 by weight complete as specified and directed.Note : The concrete shall be laid at a stretch not exceeding 3.0 m in length and joint shall be made at every turning / corners, complete all as specified and directed. |
| 65 | M&L Hardcore of guage n exc 63mm deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 66 | M &L for Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified and directed . |
| 67 | M&L for Glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10 mm thick rendering in cement mortar 1:3, complete all as specified & directed. |
| 68 | S&F for suspended false ceiling system using 4mm thick high pressure steam cured fibre cement pre-primed textured varient E-board (classic), ISI marked, conforming to IS:14982-2000 over and including GI snap grid frame work for false ceiling, grid size 605 x 605 mm with GI angle of size 24x24mm, main runner ‘T’ of size 24x38mm, secondary runner ‘T’ of size 24x28mm with 6mm GI wire with butterfly clips as hangers for leveling, fastners, supports, plugs to walls/joists etc , hangers to be fixed with approved rawl plug, level adjusters and screwsa etc, last hanger at the end of each runner shall not be greater than 450mm from adjacent wall all as per manufacturer’s Instructions including making holes, cutting chasis and making good existing walls in cement mortar 1:3 or PCC 1:2:4 type B1, complete all as specified and directed. Note :-All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm. |
| 69 | M&L for 75 mm thick plain cement concrete1:2:4, type B2, using 40 mm graded stone aggregates as in floors surfaces finished even and smooth without using extra cement all as directed. |
| 70 | M&L for Rendering 15 mm thick on fair face of brick work or concrete surface in CM 1:4, finished even and smooth without using extra cement. complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 71 | M&L for Rendering 15 mm thick on fair face of brick work or concrete surface in CM 1:4, finished even and smooth without using extra cement. complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender