Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56986212

Tender For Certain Works Services Ceo Complex And Provn Of Work Services For Installation Of Wind Sock Base Iron Pole Assembly With Obstruction Lights At Af Stn Jamnagar

Issued by Statutory Bodies & Commissions/Committees · Jamnagar, Gujarat
Tender Value
45 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
15 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Certain Works Services Ceo Complex And Provn Of Work Services For Installation Of Wind Sock Base Iron Pole Assembly With Obstruction Lights At Af Stn Jamnagar

BOQ

Name of Work:- Certain works services CEO complex and provn of work services for installation of wind sock base iron pole assembly with obstruction lights at AF Stn Jamnagar
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engineer in charge.
2Demolition of concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removal of debris to out of MoD land complete all as specified and directed by Engineer in charge.
3Dismantling Stone slabs and interlocking tiles laid dry or laid dry and pointed of any description or thickness in floors, aprons etc complete all as specified and directed by Engineer in charge.
4Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/siabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engineer in charge.
5Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer in charge.
6Demolition of cement concrete (reinforced) Jallies with frame work any type including removal of debris to out of MoD land complete all as specified and directed by Engineer in charge.
7Demolition of brickwork or stone/ boulder masonry / PCC block masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removal of debris to a distance exc 1.5 km but n.exc 2 Km, complete aaa as specified and directed by Engr-in-Charge.
8Dismantling Asbestos cement(corrugated,semicorrugated,etc) sheets in roof covering complete all as specified and directed by Engineer in charge.
9Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer in charge.
10Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4 Sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer in charge.
11Excavating over areas, n. exc 1.5 m deep and getting out in soft / loose soil complete all as specified and directed by Engineer in charge.
12Removing excavated meterial exc 250m and n exc 500 m and depositing where directed at a level n exc 1.5 m above starting point in Soil complete all as specified and directed by Engineer in charge.
13Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer in charge.
14Moorum/red bajari filling in floors or pavings, laid in layers n exc 15 CM thick, spread levelled and rammed including watering as approved complete all as specified anf directed by Engineer in charge.
15M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer in charge.
16M&L 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate)as in floors/ path finished fair and even complete all as specified and directed by Engineer in charge..
17Material & Labour for machine pressed precast concrete interlocking paver block (ISI marked) of approved shape and size of 80 mm thickness, with minimum compressive strength of 40 N / Sqmm (M-40 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating on top surface, with Grey cement and pigment including 25 mm thick sand filling under the tiles fully compected complete all as specified and directed by Engineer in charge.
18Laying only for machine pressed precast concrete interlocking paver block any shape and size complete all as specified anf directed by Engineer in charge.
19Excavation in post holes in soft/loose soil not exceeding 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus materials to a distance not exc 50m and making good surface complete all as specified and directed by Engineer in charge.
20M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified anf directed by Engineer in charge.
21S & F 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side laps fixed with coach screw and washer in roof, walls etc complete all as specified and directed by Engineer in charge.
22S & F steel work, in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes confirming to IS - 1161- 1979 grade St-240 complete all as specified and directed by Engineer in charge.
23S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour profile AZ-150 with side lap as in roof covering/ cladding to wall, fixed with 'L 'or 'J' hooks / self tapping screws and incl dismantling of plain or corrugated steel sheeting in roof covering complete all as specified and directed by Engineer in charge.
24Supply and fixing pre- painted Galvalume aluminum zinc coating GI based plain sheet 0,50mm thick of any colour having tensile strength of 550 mpa as in roof covring , chajjas/walls/, fitting & fixing ,zinc coatting including J and L hook tap screw complete all as specified and directed by Engineer in charge.
25M&L for pre-cast cement concrete block masonry type C-1,1:3:6 (20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified anf directed by Engineer in charge.
26M&L for rendering cement plaster 15 mm thick in CM 1:4 on fair faces of block masonry wall surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer in charge.
27M&L for 15mm thick Rendering on fair faces of brick work or concrete sureces in Cement Moratar 1:6 finished surface even and smooth without using extra cement complete all as specified and directed by Engineer in charge.
28M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide, zinc chrome primer complete all as specified and directed by Engineer in charge.
29M&L for preparation of old painted steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and as directed by Engr-in-Charge.
30M&L for dark shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, over screed bed 15 mm thick in cm (1:6) in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer in charge.
31M& L for Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed by engineering-in-charge.
32M&L Preparing newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer with alkali resistant complete all as specified anf directed by Engineer in charge.
33M&L Preparing old surfaces of walls and applying one coat of oil bound distemper complete all as specified and directed by Engineer in charge.
34M & L for preparing new plastered wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer in charge.Note : 1 The Paint is to be applied in camouflage pattern.2 Contractor should quote the rate considering this painting work may be executed up to 8-10 meter height of building.
35M & L for preparing old decorated wall surfaces, plastered or unplastered and applying one coat of acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 : 2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company Depot tinted) with silicon additives all as per manufacturer's instructions, complete all as specified and directed by Engineer in charge. Note :1 The Paint is to be applied in camouflage pattern.2 Contractor should quote the rate considering this painting work may be executed up to 8-10 meter height of building.
36S&F rolled mild steel Fe 410-W (Gde-E-250) quality-B in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engineer in charge.
37S&F exterior frameless glass doors, ideal for modern, transparent aesthetics, typically feature 12-15mm thick toughened safety glass, patch fittings, and high-quality stainless steel (SS) 304 grade handles (long verticle pull ), with common configurations including Manual swing added with all accesories a door is having etc complete all as specified and directed by Engineer in charge.
38Demolition and breaking up 150/200 mm dia pipes (salt glazed ware, AC or Reinforced concrete) set in cement mortar, including PCC bed, packing under and haunching against the sides, excavation in trenches in all kind of soil and returning, filling in of soil after laying of RCC NP-2 pipe including removal of debris/excavated surplus soil to out side of MOD land complete all as specified and as directed by Engr-in-Charge.
39S&F 150 mm dia reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed by Engineer in charge.
40M&L for cement concrete 1:4:8 type D2 (using 40mm graded aggregate) bed to drain pipes including packing under and haunching against the sides of pipes 150mm bore after they are laid and tested complete all as specified and directed by Engineer in charge.
41M & L for soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.00 M dia X 2.00 M effective depth upto 30 users Drg No CEAA/TD/54 complete all as specified and directed by Engineer in charge.
42On site LLDPE septic tank conventional type designed to carry sewage and sullage water including excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 30 users including removal of excavated surplus soil to out side of MOD land complete all as specified and as directed by Engr-in-Charge .
43Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer in charge.
44Returning filling in trenches incl spreading,levelling , watering& well ramming in layers n.exc 25 CM thick for in all kind of soils complete all as specified and directed complete all as specified and directed by Engineer in charge.
45Taking down unused earthing strip (GI)from building complete all as specified and as directed by Engr in Charge
46Supply and fix LED Bollard garden light fitting with base plate and necessary foundation and connected electric connections and PCC work complete and IP 65 / IK 10 bollard
47Supply and fixing Armoured cable 2 core 1.5 sqmm including PVC conduit complete all as specified and as directed by Engr in charge
48S&F LED flood Light fitting 100 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete.
49Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from old location to new location (with AF station Jamnagar), refixing of same AC at new location complete all as directed by Engr-in-Charge & detail as under:- (a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers.(b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer.(c) All civil work such as making hole in the wall for passing of pipe etc, to be done, as directed by Engr-in-Charge including making good disturbed surface. Please Enable Macros to View BoQ information
50Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from old location to new location (with AF station Jamnagar), refixing of same AC at new location complete all as directed by Engr-in-Charge & detail as under:- (a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers.(b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer.(c) All civil work such as making hole in the wall for passing of pipe etc, to be done, as directed by Engr-in-Charge including making good disturbed surface. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56986212
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 02-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Certain Works Services Ceo Complex And Provn Of Work Services For Installation Of Wind Sock Base Iron Pole Assembly With Obstruction Lights At Af Stn Jamnagar
Basic Detail
Tender No 8436/E8
Bidding Type Tender
Location
City Jamnagar
State Gujarat
Key Dates
Publish Date 12 Aug 2026
Submission Date 02 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
4cc7158e-1886-4ba7-bf25-36b23e0b802f.html
BOQ_878675.xls
PS.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

4cc7158e-1886-4ba7-bf25-36b23e0b802f.html

xls

BOQ_878675.xls

pdf

PS.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender