Tender for Provn Of Trg Shelter Adjacent Firl For Fixed Wg Infra ; special Repair Other Rank Living Accn Bldg No Owt-124,128,129 & 134 ; special Repairs (Bldg) To Cubicle Toilet And Bathroom Bldg No Owt-326 & 327 At Sigar Mil Stn Under Ge 872 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish complete all as specified and directed. |
| 2 | Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance complete all as directed by the Engr-in-Charge |
| 3 | Demolition/Dismantling of stone slabs /paver Blocks and tiles of any description or thickness laid bedded and pointed in any mortar in floors , aprons etc. and clean the surface to receive screed bed to lay new tiles complete all as directed and directed |
| 4 | Demolition of brick work or stone masonary built in cement mortor including all quoins & jambs etc. complete all as specified and directed |
| 5 | Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 6 | Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed. |
| 7 | Taking down shutters of any descriptions exc. 1 sqm and n exc 2 sqm each and removing from site complete all as specified & directed. |
| 8 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish complete all as specified and directed |
| 9 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed. |
| 10 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 11 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets/ snap grid frame etc complete all as specified and directed. |
| 12 | Taking up or down steel tubing /PP-R pipes & connection including cleaning for refixing for 25 /32 mm or removal to store as directed. |
| 13 | Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 14 | Taking down eaves gutters and rainwater/soil/waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed |
| 15 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, cable etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 16 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 17 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 18 | M & L for Sand filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed. |
| 19 | M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 20 | M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 21 | M & L Reinforced Cement Concrete 1:1.5:3, Type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.(Note : Reinforcement will be measured & paid seperately) |
| 22 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate), block masonry with solid blocks of size 300x200x200mm or 300x200x100mm, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 23 | S&F Use and waste for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed. |
| 24 | S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and as directed. |
| 25 | S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed .Note:- Fixing of wire mesh and glass shall be measure and paid separately under relevant items. |
| 26 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete Fe 410-0 W Gde-E-250 quality-A complete all as specified and directed. |
| 27 | S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides fitted to cowkhats complete all as specified and directed. |
| 28 | S&F for 2nd class hardwood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats as specified in SSR Part-I 2009.complete all as specified and directed. Please Enable Macros to View BoQ information |
| 29 | S&F for 2nd class hardwood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats as specified in SSR Part-I 2009.complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender