Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56986151

Tender For Repair / Maintenance And Replacement Of Street / Bldg Security Lights, Ornamental Lights, Post Top Lantern, Junction Boxes And Other Allied Works At Rs Colaba Mumbai Under Ge (Nw) Navy Nagar, Colaba, Mumbai

Issued by Statutory Bodies & Commissions/Committees · Mumbai, Maharashtra
Tender Value
40 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
18 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance And Replacement Of Street / Bldg Security Lights, Ornamental Lights, Post Top Lantern, Junction Boxes And Other Allied Works At Rs Colaba Mumbai Under Ge (Nw) Navy Nagar, Colaba, Mumbai

BOQ

Name of Work:- REPAIR / MAINTENANCE AND REPLACEMENT OF STREET / BLDG SECURITY LIGHTS, ORNAMENTAL LIGHTS, POST TOP LANTERN, JUNCTION BOXES AND OTHER ALLIED WORKS AT RS COLABA MUMBAI UNDER GE (NW) NAVY NAGAR, COLABA, MUMBAI
Sl. No. Item Description
1Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 3.0 m height for repair work and re-fixing back after repair work including dismantling & opening LED light fitting, opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs/LED panel, replacement of defective driver/surge protection devices complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as directed by Engr-in-Charge.Note:a) The Items like electronic drivers, surge protection devices & LED panel etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.
2Supply only the following spares suitable for LED street/Flood light fittings.
3Electronic driver suitable for outdoor LED fitting of capacity 200 to 400 Watt.
4Electronic driver suitable for outdoor LED fitting of capacity 120 to 180 Watt.
5Electronic driver suitable for outdoor LED fitting of capacity 70 to 110 Watt.
6Electronic driver suitable for outdoor LED fitting of capacity 30 to 60 Watt.
7Surge protection device compatible with industrial & outdoor LED fitting of capacity 5 KV complete all as specified and as directed.
8Surge protection device compatible with industrial & outdoor LED fitting of capacity 10 KV complete all as specified and as directed.
9Supply only LED light panel of capacity 200 to 400 W.
10Supply only LED light panel of capacity 120 to 180 W.
11Supply only LED light panel of capacity 70 to 110 W.
12Supply only LED light panel of capacity 30 to 60 W.
13Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 45 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
14Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
15Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
16Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 9000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 90 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
17Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Make:Crompton /Phillips/C&S /Havells/ Wipro/ Henolix . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.
18Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
19Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
20Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 25000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 250 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
21Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 35000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 350 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed.
22Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 40000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 400 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed.
23Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete.Note :- (i) Driver shall be IP 66 degree of protection potted seal type. (ii) Power factor more than 0.9. complete all as specified and direrected by Engr in Charge.
24Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including two coats aluminium painting over a coat of red oxide primer with pole no writing complete all as directed incl dismantling old one. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.
25Supply, laying and commissioning, testing armoured heavy duty electric cable with copper conductor, 1100 volts grade of size 4 sqmm 4 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles/bottle lugs and taking out old u/s damaged cables.
26All as per item No- 19.00 here in before but of size 2.5 sqmm 3 core including taking out old u/s damaged cables.
27All as per item No- 19.00 here in before but of size 1.5 sqmm 2 core including taking out old u/s damaged cables.
28M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete.
29M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work.
30S & F astronomical Timelite distribution board IP-54 with contactor, relay and prewired, 32A, 3 pole, 230 Volt , and Astronomical programmable time switch with backup of 6 years, 28 memory locations, current capacity 16 A with one CO time switches for street light complete.
31S & F in repairs analog time switch 3 phase of current capacity 16 Amps incl any type of accessories for fixing of time switch after taking out unserviceable one.
32S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carrying capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed.
33S & F in repair MCB TPN 32 Amp 230 volt AC complete all as directed.
34S & F in repair MCB TPN 63 Amp 230 volt AC complete all as directed.
35Material & Labour for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of 4 mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 15 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion including taking down old one complete all as specified. NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth wire upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing.
36S&F loop-in/loop-out box of outer size size 225mmx295mmx122mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm aluminium clamp not less than, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
37S&F in repair thermoplastic cable junction water proof boxes of 130x130x77mm, with metric knockouts for cable entry and suitable size of gland for 4 to 10 Sqmm cable out door type with clamp for mounting on pole complete all as specified and as directed.
38S&F street light bracket bend to shape made as required of 32/40mm dia 1 mtr long GI pipe light grade fixed to pole/wall with flat iron clamp of size 40x6mm two number with the help of nuts and bolts for fixing of street light fitting including making all electric connection including taking out old one complete all as specified and as directed.
39M&L for preparation of old painted steel surfaces of 9/11 mtr long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with white letters/ blackground etc complete all as directed
40Repairs to High Mast/mid mast pole motor of Capacity 1.0 HP/0.75 KW 415 Volts 50 Hz 3 Phase 930 RPM and necessary rewinding with super enamelled copper wire all as per existing and servicing/greasing of reduction gear box complete all as specified and as directed by Engr-in-Charge.
41Decarbonising of the control panel of High mast/Mid mast and including sevicing of parts such as contactors/timers including replacement of pitted lugs,thimbles, control wiring etc complete including painting with a coat of synthetic enamel paint
42Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
43All as per above item No.36 above but exceeding depth 1.5 mtr and n exceeding 3 mtrs.
44Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils.
45Removing excavated material from the site of work and transporting out of Station exc. 1.50 km but n exc. 5 km as specified and directed.
46Material and labour for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of size 250x250 mm having compressive strength of 35N/Sqmm, zig-zag (uni-paver) shape in flooring tested as per IS : 15658-2006, complete as specified and directed.
47Material and labour for layer of 50 mm thick natural river sand bed under floors or in foundation or under paver blocks including watering and consolidation complete as specified and directed.
48Cutting existing road surfaces or hard standing 0.45 mtr depth (22 thick comprising bituminuous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing surfaces.
49Material and labour for cement concrete type C-2, 1:3:6 (40mm graded stone aggregate), for road cutting/hard standing and finished surface without using extra cement.
50Supplying and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 50 sqmm 3.5 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old u/s damaged cables.
51All as per Item No-44.00 here in before but of sizes, 35 sqmm, 3.5 core.
52All as per Item No-44.00 here in before but of sizes, 25 sqmm, 3.5 core.
53All as per Item No-44.00 here in before but of sizes, 16 sqmm, 4 core.
54All as per Item No-44.00 here in before but of sizes, 10 sqmm, 4 core.
55All as per Item No-44.00 here in before but of sizes, 10 sqmm, 2 core.
56M&L for 50mm dia High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, for road crossing of cable or for cable protection laid in trenches or above ground surface all as specified and directed. Make: Finolex/Supreme/Prince
57All as per Item No-50.00 here in before but of sizes, 75mm dia
58M&L for GI pipe ,light grade 50mm dia for road crossing or in hard standing for protection of cable above or under ground surface including taking out old one all as specified and directed.
59All as per Item No-52.00 here in before but of sizes, 80mm dia
60S&F manual operated security search light complete with brass body including LED 200 watt lamp with lens, handle for rotation of search light luminous flux 26000, operating temperature 20 deg C to 60 deg C, IP-65 protection, working humidity 5% to 95% RH of range cover 250 Mtr, THD<10%, power factor>0.95, CRI>70, mounting base cap, reflector complete system including taking out U/S complete all as directed.
61Supply and fixing of MCCB 100A, 25kA, 4P, 415 V Thermal adjustable – 0.8 to 1In, Magnetic adjustable – 5 to 10In, Ics=100% Icu . Make : Legrand/Siemens/Schneider/ABB
62S&F in replacement of 20 watt LED RGB under water light IP68 luminaire, size - 190mmx250mm with stainless steel housing with driver including necessary stand for fixing of fountain light with mounting base including making all electrical connection complete.
63All as per item No - 56.00 above but LED RGB under water, 12 watt.
64S&F Decorative Ornamental Cast iron Pole of height 3 Mtr with base dia of 200mm, bottom-210mmx450mm above the foundation top level fabricated with cast iron embellishment, joints, column sections etc re-inforced internally with a MS pipe inside and inbuilt looping box for incoming and outgoing UG cable. The pole shall have cast iron bracket for top mounting single decorative lantern of size 21\\"x9\\" . The pole shall be painted with polyurethane paint of approved colour finish including fixing and grouting to old existing foundation with the help of Nuts, bolts and washer, making all electrical conection to light fitting after taking out old CI pole and necessary PCC work, all as directed. Make- EYE-Lite luminaires or equivalent as per sample
65S&F Decorative Alluminium casted, powder coated lantern of size 21\\"x9\\" for decorative ornamental poles with holder for LED Lamp and with 6 Nos of Polycarbonate/frosted Glass for optical compartment as per sample and reconnecting all electrical connection to light complete including taking out old U/S.
66S&F in replacement with new LED pin type lamp of 14 watt warm white after opening of post type lantern fitting from deco pole and checking of all electrical connection and refixing the lantern cover on its existing arm of deco pole.
67S&F Aluminium casted pole of 1.5 Mtr long, powder coated with foundation bracket and holder for mounting of decorative Garden light including necessary PCC plateform for grouting pole and reconnecting all electrical connection to light complete including taking out old U/S.
68Supply and fixing Frosted Glass suitable for optical compartment of Decorative light fittings (As per sample) approved by Engr-in-Charge.
69Supply and fixing LED based bollard light 9 watt with MS pipe housing with glare free PMMA diffuser,IP-65 complete with necessary PCC foundation and PCC block of 60cm height above ground including taking out old, U/S complete all as directed.
70S&F Integral decorative LED 45 Watts Post Top with opal acrylic with IP65 Protection mounted on 1.5 Mtr GI pole complete with necessary PCC foundation and PCC block of 60cm height above ground including taking out old, U/S complete all as directed.
71All as per item No - 64.00 above but LED Post Top lantern 20 watt.
72M&L for re-saddling of conduits with wiring on external wall surfaces of buildings for building security lights with provision of new PVC/MS clamp, screws and plugs etc as required at site complete all as specified and directed by Engr-in-Charge. Note : New PVC conduits and wiring if required at site shall be measured and paid separately under relevant items of the schedule.
73Supply and fixing LED Column Light 50 watt, 4 mtr height with die-cast aluminum pipe housing with cylindrical opal polycarbonate diffuser designed for rugged outdoor usage & IP 65 protection with Tricolor and tratic white output switch mounted on PCC block including connection copper wire of required length (not more than 2 mtr), connector and thimble/lugs etc complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56986151
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 01-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance And Replacement Of Street / Bldg Security Lights, Ornamental Lights, Post Top Lantern, Junction Boxes And Other Allied Works At Rs Colaba Mumbai Under Ge (Nw) Navy Nagar, Colaba, Mumbai
Basic Detail
Tender No 8671/E8
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 12 Aug 2026
Submission Date 01 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Not Available
Document List
a05a0b35-0d04-45c9-b09a-d92cab883daf.html
BOQ_878702.xls
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

a05a0b35-0d04-45c9-b09a-d92cab883daf.html

xls

BOQ_878702.xls

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail