Health and Family Welfare Government Departments Closing in 2 days TDR #56983763

Tender For Supply Installation Testing and Commissioning of Medical Gas Pipe Line System Work For Construction Of Sub District Hospital At Anta.

Issued by Government Departments · Kota, Rajasthan
Tender Value
87.61 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
2 days left
EMD
1.75 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kota → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Medical Gas Pipe Line System Work For Construction Of Sub District Hospital At Anta.

BOQ

Name of Work:- SITC of Medical Gas Pipe Line System work for construction of Sub District Hospital at Anta.
Sl. No. Item Description
1SITC of MGPS pipe of medically grade as per BSEN-13348 with third party certification from Lloyds/TUV degreased [ie free from oil, grease and particulate matters) seamless copper pipe confirming to ASTM B88 and all copper joining done by brazing with AWSA5.8, classification BCuP-5 or BS 1845 following procedure in accordance with ASTM B828 after purging with nitrogen. All pipe cutting shall be carried out with a radial pipe cutter and copper pipe fitting's shall comply with B4 alloy designation. Adequate support shall be provided while laying pipeline testing shall be done at 17 bar and after testing pipe shall be painted with two coat of enamel paint as per colour codification as per ISO 7396-Part-1 2016.Thisd partyTest reportshall be submitted. all as per approved by Engineer in charge.
2SITC of non lubricated ball type nicel Coated Isolation Valve with adapter & PTFE Seat having quarter turn / Butterfly handle opening of following sizes suitable fo flow capacity of required LPMas per the size of valve at 4.7 bar with maximum allowable pressure of 30 bars and suitable for working temperature renging - 20 °C to 130 °C. Appropriate Test Certificate/ report of product/ accessories from OEM shall be submitted. All a per approved by Engineer in charge. For 12 MM OD pipe (only to be used in oxygen line)
3For 15 MM OD pipe
4For 22 MM OD pipe
5For 28 MM OD pipe
6For 42 MM OD pipe
7For 54 MM OD pipe
8SITC of Gas outlet point Oxy, (AR-4), (AR-7) and Vaccum (8.7 psig) for dispeensing medical pgases (oxygen/air/Vaccum) at point of use confirming to BSEN ISO 9 170-1:2008.. The gas outlet are quick connect type. it should have colour coding for dieffrent gas source and should accept only respective adapters as required.appropriat Test Certificate/ report of product/accessories from OEM shall be submitted. The Product should be CE Certified /CE marked. (oxygen - 100nos, vaccum - 100nos, air-4 -50(only in OT,ICU or where ventilator is installed), air-7 - 5nos(only in OT), nitrous - 5nos(only in OT)
9SITC of BPC (back pressure compensated) flow meter with Humidifire made of nickei plated body. Double jacketed with flow gradations CE Marked on it. Desired flow will be setteided through rotary knob. Flow range shuld be between 0 to 15 lpm & work should be executed as per direction of engineer in charg. Appreoprite Test Certificate / report of product /accessories from OEM shall be submitted. The Product should be CE Certified/ CE Marked.
10SITC of ward suction unit (Sution Controller and Collevtion Jar - 600 ml caapicity) with posibility to configure required capcity collection Jar and should meets the reuirements as per BSEN ISO 10079-3:2009. The unit must designed to operate with the vaccum line of MGPS. The collection jar must accumpained with Vaccum regulator suitable for 0-14.7 psig with flow rate 0-55 lmp (min)for operating tempurature - 18 °C to 50 °C with ON/OFF facility. The collection Jar should be transparent, made of hogh quality polycarbonate that can be autoclaved at 121 °C for 20 minuts for reuse and provided with auto stop to avoid over spill and contamination of the suction source when the jar collection reached optimized level. The completer unit supplied with filter to protect the source and pipe line from baceterial contamination. Appropriate Test Certificate / report of product/ accessories from OEM shall be submitted . The Product shpuld be CE Certificate / CE marked
11Suction troly
12SITC of Valve box made of CRCA sheet duly powder coated with transparent window which is installed in the MGPS for oxygen and vaccum line and should comply with BSEN ISO 5211:2001 complete with ball type valves and gauses as required for oxygen compressed air and vaccum line. Appropriate Test Certificate / report of product/ accessories from OEM shall be submitted . The Product shpuld be CE Certificate / CE marked For Twoe gas (for general ward only oxy+vacc gas is required)
13For Three gas
14For Four gas
15For Twoe gas
16For Three Gas Services
17For Four Gas Services
18SITC of Color Coded high Pressure RubberTube for Positive Pressure Gases / vacuum. Appropriate Test Certificate/report o product/accessories from OEM shall be submitted. The Product shpuld be CE Certificate / CE marked. All as per approved engineer incharge.(only used in vaccum jar 1mtr per jar)
19SITC of Bed Head Panel of 900 -1500 MM long made out from high strength extruded aluminium with powder coating with at least 4 nos 6/16 Amp switch socket and provision for required number of gas outlet points as suggested by the client. Appropriate Test Certificate/report o product/accessories from OEM shall be submitted. The Product shpuld be CE Certificate / CE marked. All as per approved engineer incharge. (not required in general ward bed, required only in critical area beds where electric monitor or other electric instruments had to used like icu,NICU,pre-OP, post OP)
20Providing and fixing of Rail clamp for mountin ward vaccum unit on bed head panel com Plete as required'
21P&F of Bed Panel accessories like Monitor Tray, Utility Basket, Vacuum Slider, Infusion PumP Pole with IV hooks, with proper nut bolts and screw and with Proper finishing . Appropriate Test Certificate/report o product/accessories from OEM shall be submitted. The Product shpuld be CE Certificate / CE marked. All as per approved engineer incharge. Utility Basket
22Vacuum Slider
23Infusion Pump Pole
24Moniter Tray
25SITC of Automatic Gas Control Panel for Each oxygen/Nitrous 0xide - Control Panel .out made for M.S. duly Powder coated. Compact and fully automatic manifold control Panel cover made of M.S. duly power coated. Compact and ffully automatic manifold control system for Oxygen service. Easy to maintain and use. Designed with both safety and continuity of flow supply at a constant pressure via two banks of bottled gas cylinders with following status monitoring. A -Bank in use [Green Indicationi f - EmPW bank [Red Indication). Control Panel should have built in LED display to indicate Normal, High & Low line pressure. It.should have facility to test all above indicators working perfectly. the control panel should include pressure gauge to indicate the gas pressure of each header and pipe line distribution pressure. Capable to provide a distribution flow rate in excess of 1200 LPM. The control panel should incbrporate manual bypass system in case of failure of shifting mechanism. It should be of CE Certificate / CE marked. All as per approved engineer incharge.
26SITC of Oxygen/Nitrous Oxide Manifold System [8+8) with tail pipes NRV - manifold system comprise of bank of 8+8 cylinders (Bulk cylinder of D type) capacity manifold high pressure copper pipe of size 1/2 \\" x14 swg (approx. 2.0320 mm) & high pressure fitting made of high tensile strength brass be used to connect the cylinders to the header assemblies with 16 no,s non return valves & 16 no's high pressure flexible tail pipe is made of copper pipe of 1/3\\"x16 swg (approx. L.6256 mm) the manifold is hydraulically tested at 225kg/cm2 pressure it is also degreased and is to be offered duly wrapped in a polythene bag. Appropriate Test Certificate/report of product/accessories from OEM shall be submitted. The Product shpuld be CE Certificate / CE marked. All as per approved engineer incharge.(not required same size for Nitrous because nitrous pnly had to be used OT)
27SITC of Emergency Oxygen/ Nitrous Oxide Manifold System (2+2)with tail pipes NRV and One DGSS Reglator of minimum 600 LPM capacity- manifold system comprise of bank of 2+2 cylinders (Bulk cylinder of D type ) cpacity manifold high pressure copper pipe of size1/2\\" ID X 14swg(approx 2.0320) & high pressure fitting made of high tensile stenth brass be used to connect the cylinders to the header assemblies with 4 no' no 'non return valves & 4 no's high pressure flexible tail pipe is made of coper pipe of 1/3\\" X 16 swg (approx 1.6256 mm) the manifold hydraulically tested at 225 kg/cm pressure it is also defreased and is to be Note : Providing if Cylinders is in the scope of Hospital / end Client. Approcriate Test Certificate / report of product /accessoriesfrom OEM shall be submitted . The Product should be CE Certified / CE marked. All as per approved engineer incharge.
28SITC of Dessicsnt Air Dryer Output Capacity as below with Certified Microproccessor Controller with dewpoint based changeover option . Pre- filter rating 0.3 microns , Shuttle valve for Low Pressure drop. All Aluminium resist oxidtion & scale formtion , Dewpoint better than -40 C including fixing on wall with required T & P mking connections etc complete in all respect. Appreoprite Test Certificate / report of product /accessories from OEM shall be submitted. All as per approved engineer incharge.
29SITC of Compressed Air System should consist of 1 nos. Air Compressors with Electric Motors, Electrical Switch Gear and Automatic Control SYstem of following Specifications:a)- Air Compressor L(0ne) Nos; Type Non-lubricated / Oil-free; Minimum Capacity 24.43 cfm (Poston Displacement) at 8.5 kg/cm2: Coolong air cooled. b) Drive- Electric Motor 1 [one) Nos; Capacity 75 HP; Speed L440 rpm (syn.); Drive Belt drive; Electricity supply 440 volt, 50 Hz. 3 Phase c) Starter Star/Delta Control & Switchgear with overload protection.including making PCC foundation and fixing withbolts , anti vibration pad and making connections complete as required. Appropriate Test Certificate/report of product/accessories from OEM shall be submitted. The Product shpuld be CE Certificate / CE marked. All as per approved engineer incharge.
30SITC of vacuum Pump of Single stage , capacity minimum 3141 LMP/ 111 CFM (Piston displacement ). The pump should be suited for maximum working pressure of 29 inch mercury (730 mm mercury) The pump should be fitted with MS channel frame complete having vibration isolators with 1 nos. silencers at vacuum pump discharge end. The pump should be air coold. 1 set of isolation valve, on return and filter should be proviede with pumps. Drive assembly The electrical drive for vcuum should be consist of suitable TEFC induction motor operating at 1440 RPM and connectd through a V- belt The motor should be suited for 415 V+ 10% 50HZ . 3 phase SC supply. Capacity : 7.5 HPof a reputed make Vacuum Switch: Vacuum Switch of 0-760 mm range should provided, it should have both NO/NC contracts and suitable for 230 V 50 Hz.. AC supply. The vacuum switch should be housed in weather proff casing with 3/8\\" BSP gas service connetion at the bottom of assembly. Vacuum filter :1 Nos vacuum with drain valve . This filter should be non-ferrous and inlie. Including making PCC foundation and fixing with bolts, anti vibration pad and making connection completer as required. Appropriate Test Certificate/report of product/accessories from OEM shall be submitted. The Product shpuld be CE Certificate / CE marked. All as per approved engineer incharge.
31SITC of Compressed air filtration system and regulating systum :One set of 3 - stage filter The filters should be made of die cast aluminums housing with epoxy power paint on the outside and anodized surface treatment inside to prevent corrosion and ensure extra long life. The filters should have maximum contaminant removal efficiency with minimum pressure drop. Total 3-stage of filters should be used as mentioned below:-Stage 1 : coalescing filters for generalpurpose protection, removing liquid water and oil aerosol to 0.1 mg/cum. [0.1 pm) and particles down to 5 micron.Stage 2 : particular filter for dust protection, removing particles down to 1 micron. Stage 3 : high efficiency coalescing filters, removing liquid water and oilaerosol to 0.01 mg/cu.m. (0.01 pip) and particles down to 0.0L micron.Janatics regulator 1/2\\" or 3/4\\" to be installde for regulating the Output air pressure. . Appropriate Test Certificate/report of product/accessories from OEM shall be submitted. The Product shpuld be CE Certificate / CE marked. All as per approved engineer incharge.
32SITC of Hot dipped galvanized ( inside and outside ) and powder coated . Air/ Vacuum receiver tank fas per lS:7938-L97 6 and upto date amendment) for compressed air system to dampen out pulsation and condense and trap the moisture in the compressed air and also to let oil and other impurities settle down before air passes into the piping with safety valve , Drain Valve , Pressure gauge and fusible plugs of 1000 litres capacity complete as required including fixing with bolts and making cinnections complete as required.Appropriat Test Certificate/report of product/accessories from OEM shall be submitted.
33Providing & Fixing ISO certified company made on load change swutch, front handle operated, four polee 415 operating handle , source seprator and phase barrier included , conforming to IS/IEC 60947-3 : I999 including connections testing etc. as requored Appropriate Test Certificate/report of product/accessories from OEM shall be submitted. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56983763
AUTHORITY Government Departments
TENDER VALUE 87.61 Lakhs
LAST DATE 19-08-2026
Authority
Authority Name Medical And Health Services
Work Description Tender for Supply Installation Testing and Commissioning of Medical Gas Pipe Line System Work For Construction Of Sub District Hospital At Anta.
Basic Detail
Tender No NIT No 07/2026-27 EXECUTIVE ENGINEER MEDICAL AND HEALTH KOTA
Bidding Type Tender
Location
City Kota
State Rajasthan
Key Dates
Publish Date 13 Aug 2026
Submission Date 19 Aug 2026
Open Date 20 Aug 2026
Finance
Tender Value 87.61 Lakhs
Tender Fee 1500
EMD 1.75 Lakhs
Exemption Not Available
Document List
666d04d0-bd83-4947-94ca-d69062ac22c7.html
BOQ_1041881.xls
Tendernotice_1 (37).pdf
Tendernotice_2 (6).pdf
Tendernotice_3 (2).pdf
Tendernotice_4 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

666d04d0-bd83-4947-94ca-d69062ac22c7.html

xls

BOQ_1041881.xls

pdf

Tendernotice_1 (37).pdf

pdf

Tendernotice_2 (6).pdf

pdf

Tendernotice_3 (2).pdf

pdf

Tendernotice_4 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders