Tender For Repair, Replacement Of Unserviceable Street Lights, Flood Light Installed At Aa-Ic & Id At New Town, Kolkata
Tender Overview
Project Description
Tender for Repair, Replacement Of Unserviceable Street Lights, Flood Light Installed At Aa-Ic & Id At New Town, Kolkata , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminium Body (System Lumen Efficacy ≥ 135 Im/Watt). Supplying , Installation, Testing And Commissioning Of Street Light Led Fixture, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage : 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C,, Internal Surge Protection Of 5Kv L,N,E As Per Iec 61000-4-5, Driver Efficicency 85%, Thd 10% As Per Iec 61000-3-2, P.F 0.95, Ip-66, Ik-10, Cri ≥70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement, Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led, Driver & Electrical Circuitary) Of Minium 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K/4000°K/5700°K/6500°K (As Per Ansi Bin), Sdcm (Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc, As Required With Minium 5 Year Oem Warranty. System Lumen Efficacy ≥135 Lm/Watt Output. Lm79 & Lm80 Test Report And All Testing Rewquired For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In Chage As Per Requirement. (Thermal Management : Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C) , 150 Watt , Led Flood Light , Powder Coated Pressure Die Cast Aluminium Body (System Lumen Efficacy ≥ 120 And 135 Lm/Watt). Supplying , Installation, Testing And Commissioning Of Flood Light Led Fixture, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage : 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C,, Internal Surge Protection Of 5Kv L,N,E As Per Iec 61000-4-5, Driver Efficicency 85%, Thd 10% As Per Iec 61000-3-2, P.F 0.95, Ip-66, Ik-10, Cri ≥70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle30 Dgree-120Deg As Per Application And The Project Requirement, Suitable Tilt Able Fitting, Life Time (Led Driver & Electrical Circuitary) Of Minium 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K/4000°K /5700°K/6500°K (As Per Ansi Bin), Sdcm (Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc, As Required With Minium 5 Year Oem Warranty. System Lumen Efficacy ≥105 120 Lm/Watt Output. Lm79 & Lm80 Test Report And All Testing Rewquired For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In Chage As Per Requirement. (Thermal Management : Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C) , 150 Watt , 200 Watt , 250 Watt , Supplying Of Following Xlpe Insulated Aluminium Conductor Armoured Cable Of 1.1 Kv Grade As Per Is 7098 (Part-I) 1988 With Upto Datae Amendments :- (A) 4 Core 16 Sqmm , Supplying Of Following Xlpe Insulated Aluminium Conductor Armoured Cable Of 1.1 Kv Grade As Per Is 7098 (Part-I) 1988 With Upto Datae Amendments :- (A) 4 Core 25 Sqmm , Finishing The End Of Following Xlpe/Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket (Dowels Make), Tapes, Anticorrosive Paste & Jointing Materials : , (A) 4C 16 Sqmm Cable , (B) 4C 25 Sqmm Cable , Supplying And Fixing Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Of Xlpe/Pvc Armoured Cables As Below : , (A) For 4 Core Upto 16 Sqmm , (B) For 3.5 Core Upto 25 Sqmm , Supplying And Making Straight Through Joint With Cast Resin Compound Including Ferrules And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed/Xlpe Aluminium Conductor Of 1.1 Kv Grade As Required : 4 Core 16 Sqmm.
BOQ
| Sl. No. | Item Description |
| 1 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥ 135 im/Watt). Supplying , Installation, Testing and Commissioning of street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage : 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C,, internal surge protection of 5KV L,N,E as per IEC 61000-4-5, Driver efficicency >85%, THD <10% as per IEC 61000-3-2, P.F> 0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitary) of minium 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (standard Deviation color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 Sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc, as required with Minium 5 year OEM warranty. system lumen efficacy ≥135 lm/Watt output. LM79 & LM80 Test report and all testing rewquired for LED fixtures as per BIS shall be submitted. shape size and CCT shall be as approved by Engineer-In Chage as per requirement. (Thermal management : heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) |
| 2 | 150 Watt |
| 3 | LED Flood light , powder coated pressure die cast aluminium body (System lumen efficacy ≥ 120 and <135 lm/Watt). Supplying , Installation, Testing and Commissioning of Flood light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage : 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C,, internal surge protection of 5KV L,N,E as per IEC 61000-4-5, Driver efficicency >85%, THD <10% as per IEC 61000-3-2, P.F> 0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle30 dgree-120deg as per application and the project requirement, suitable tilt able fitting, life time (LED Driver & electrical circuitary) of minium 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K /5700°K/6500°K (As per ANSI Bin), SDCM (standard Deviation color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 Sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc, as required with Minium 5 year OEM warranty. system lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing rewquired for LED fixtures as per BIS shall be submitted. shape size and CCT shall be as approved by Engineer-In Chage as per requirement. (Thermal management : heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) |
| 4 | 150 Watt |
| 5 | 200 Watt |
| 6 | 250 watt |
| 7 | Supplying of following XLPE insulated aluminium conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 with upto datae amendments :- (a) 4 Core 16 Sqmm |
| 8 | Supplying of following XLPE insulated aluminium conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 with upto datae amendments :- (a) 4 Core 25 Sqmm |
| 9 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 10 | (a) 4C 16 Sqmm cable |
| 11 | (b) 4C 25 Sqmm cable |
| 12 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 13 | (a) For 4 core upto 16 Sqmm |
| 14 | (b) For 3.5 core upto 25 Sqmm |
| 15 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor of 1.1 KV grade as required : 4 Core 16 Sqmm. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender