Bids Are invited for 12 Hp Vrf Air Conditioner - Supply, Installation, Testing And Commissioning Of Variable Refrigerant Flow/Volume Type Air-Condition System Suitable To Operate From 415 ± 10% Volt, 50 Hz,3 Phase Ac Power Supply For Cooling/Heating
Tender Overview
Project Description
Bids Are invited for 12 Hp Vrf Air Conditioner - Supply, Installation, Testing And Commissioning Of Variable Refrigerant Flow/Volume Type Air-Condition System Suitable To Operate From 415 ± 10% Volt, 50 Hz,3 Phase Ac Power Supply For Cooling/Heating With Compressors Dc Inverter ,Isolator Of Suitable Size In Weather Proof Enclosure, Vibration Isolators With Necessary Wiring , Connection & Termination Etc. Including Full Charging Of R-410A Refrigerant Gas Complete As Per Requirement , 12Hp Digital Ducted Split Room A/C (Ds) Outdoor Unit (Odu) And Indoor Unit (Idu) (Both) , Supply, Installation, Testing And Commissioning Including Vaccumiaztion And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping Of Ducted System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tublar Insulation/With Class-O Closed Cell Elastomeric Nitrile Rubber Tubular Sleeves And Liquid Lines, All Accessories As Per Specifications Etc. As Required: , 19 Mm Da (Od) (Hard Drawn) With Tube Thickness 1.2 Mm With 19Mm Thick Insulation , 28.54 Mm Da (Od) (Hard Drawn) With Tube Thickness 1.2 Mm With 19Mm Thick Insulation , Providing & Fixing Of Pvc Pipe Compete With Fittings, Supports As Per Specification And Duly Insulated With 6 Mm Thickness Of Closed Cell Nitrile Rubber Insulation Etc As Req (For Drain) , 25 Mm , Supplying And Drawing Following Sizes Of Pvc Insulated Copper Conduction, Single Core Cable In The Existing Surface , 3X2.5 Sqmm , Lifting And Shifting Of Ac , Dismantling Of Existing Ac , Canvass Connection , Modification Of Ducting At Indoor Unit
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supply, Installation, Testing and Commissioning of Variable refrigerant flow/volume type air-condition system suitable to operate from 415 ± 10% volt, 50 Hz,3 phase AC power supply for cooling/heating with compressors DC Inverter ,isolator of suitable size in weather proof enclosure, vibration isolators with necessary wiring , connection & termination etc. including full charging of R-410A refrigerant gas complete as per requirement | Supply, Installation, Testing and Commissioning of Variable refrigerant flow/volume type air-condition system suitable to operate from 415 ± 10% volt, 50 Hz,3 phase AC power supply for cooling/heating with compressors DC Inverter ,isolator of suitable size in weather proof enclosure, vibration isolators with necessary wiring , connection & termination etc. including full charging of R-410A refrigerant gas complete as per requirement |
| 2 | 12HP DIGITAL DUCTED SPLIT ROOM A/C (DS) Outdoor Unit (ODU) and Indoor Unit (IDU) (both) | 12HP DIGITAL DUCTED SPLIT ROOM A/C (DS) Outdoor Unit (ODU) and Indoor Unit (IDU) (both) |
| 3 | Supply, Installation, testing and commissioning including vaccumiaztion and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping of Ducted system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tublar insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves and LIquid lines, all accessories as per specifications etc. as required: | Supply, Installation, testing and commissioning including vaccumiaztion and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping of Ducted system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tublar insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves and LIquid lines, all accessories as per specifications etc. as required: |
| 4 | 19 mm da (od) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation | 19 mm da (od) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation |
| 5 | 28.54 mm da (od) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation | 28.54 mm da (od) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation |
| 6 | Providing & Fixing of PVC pipe compete with fittings, supports as per specification and duly insulated with 6 mm thickness of closed cell nitrile rubber insulation etc as req (for drain) | Providing & Fixing of PVC pipe compete with fittings, supports as per specification and duly insulated with 6 mm thickness of closed cell nitrile rubber insulation etc as req (for drain) |
| 7 | 25 mm | 25 mm |
| 8 | Supplying and drawing following sizes of PVC insulated copper conduction, single core cable in the existing surface | Supplying and drawing following sizes of PVC insulated copper conduction, single core cable in the existing surface |
| 9 | 3x2.5 sqmm | 3x2.5 sqmm |
| 10 | Lifting and Shifting of AC | Lifting and Shifting of AC |
| 11 | Dismantling of Existing AC | Dismantling of Existing AC |
| 12 | Canvass Connection | Canvass Connection |
| 13 | Modification of Ducting at Indoor Unit | Modification of Ducting at Indoor Unit |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender