Defence Statutory Bodies & Commissions/Committees Closing in 25 days TDR #56976263

Tender For Provision Of Stps At Installation Chilka

Issued by Statutory Bodies & Commissions/Committees · visakhapatnam, Andhra Pradesh
Tender Value
8.40 Crore
Estimated cost
Bid Submission
09 Sep 2026
25 days left
EMD
7.45 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
visakhapatnam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Provision Of Stps At Installation Chilka

BOQ

Name of Work:- PROVISION OF STPs AT INS CHILKA
Sl. No. Item Description
1Schedule \\"A\\" Part – I:-Sewage Treatment Plants(This schedule is not pre-priced by MES. Contractor has to quote his own rates.)
2Design, Supply, Installation, Testing and Commissioning of fully automatic Sewage Treatment plant(STP) of the under mentioned capacities with suitable technology as per geographic location, temperature differential and rainfall. The design of Plant can be either biological process or physical separation process with chemicals as secondary treatment process and must comply with the teritiary treated water parameter and also considering the points while designing the STP:-
3900 KLD capacity
4300 KLD capacity
5200 KLD capacity
6Designing, Supplying, Developing, lnstallation, Integrating and Commission STP SCADA System along with various Automation equipment for under mentioned STPs:-
7900 KLD capacity
8300 KLD capacity
9200 KLD capacity
10Schedule \\"A\\" Part – II to XI:NOTE: Schedule \\"A\\" Part – II to Part – XI are prepriced by MES.
11Lumpsum price worked out by the contractor for \\"BUILDINGS AND STRUCTURES\\", as listed in Schedule \\"A\\" Part – II (Refer pre priced schedule attached seperately).
12Lumpsum price worked out by the contractor for \\"SITE CLEARANCE, AREA DEVELOPMENT AND EARTH WORK\\", as listed in Schedule \\"A\\" Part – III(Refer pre priced schedule attached seperately).
13Lumpsum price worked out by the contractor for \\"INTERNAL ELECTRIFICATION\\", as listed in Schedule \\"A\\" Part – IV (Refer pre priced schedule attached seperately).
14Lumpsum price worked out by the contractor for \\"INTERNAL WATER SUPPLY\\", as listed in Schedule \\"A\\" Part – V (Refer pre priced schedule attached seperately).
15Lumpsum price worked out by the contractor for \\"ROAD, PATH & HARD STANDING\\", as listed in Schedule \\"A\\" Part – VI (Refer pre priced schedule attached seperately).
16Lumpsum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY\\", as listed in Schedule \\"A\\" Part – VII (Refer pre priced schedule attached seperately).
17Lumpsum price worked out by the contractor for \\"EXTERNAL ELECTRIFICATION\\", as listed in Schedule \\"A\\" Part – VIII (Refer pre priced schedule attached seperately).
18Lumpsum price worked out by the contractor for \\"SEWAGE DISPOSAL\\", as listed in Schedule \\"A\\" Part – IX (Refer pre priced schedule attached seperately).
19Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part - X (Refer pre priced schedule attached seperately).
20Lumpsum price worked out by the contractor for \\"GATE, FENCING AND COMPOUND WALL\\", as listed in Schedule \\"A\\" Part – XI (Refer pre priced schedule attached seperately).
21Schedule \\"A\\" Part - XII (Miscellaneous items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col. 5 siginifies this fact only. Contractor has to quote his own rates.
22Miscellaneous items for Internal Electrification :
23S&F ceiling fans completed with blades, down rods, electronics regulator and accessories, 230V 1200mm sweep min air delivery 210 CFM with service valve 6.00 BEE five star rated brushless direct current motor (BLDC)
24Miscellaneous items for Internal water supply
25S&F for 15mm dia Two way Bib cock, cast copper alloy with wall flange and lever handle, screwed down, screwed for pipe or for unions and fixed complete all as specified and as directed.
26S&F for Health Faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25m long flexible and ABS wall hook including making connections and fixed in position complete in all reapect as specified.
27Miscellaneous items for External Electric supply
28S/F double wall corrugated ,High density polyethylene pipes (HDPE) of 100 mm dia laid in trenches walls, ceilings or in floors etc. complete all as specified and as directed by the Engineer-in-Charge complete.
29M & L for drop out fuse assembly (set of three) mounted on insulator and steel frame horizontal/vertical type for HT 11 KV lines including connections etc complete all as specifeid & directed.
30Supply, installation, testing and commissioning of outdoor LT feeder pillar box panel board (2000 x1500 x 500 mm), CPRI Approved, made out of CRCA sheet 3.15 mm thick vermin proof factory made double door with 40 x 40 x 6 mm MS angle/channel duly painted with two coats of synthetic enamel powder coated paint over a coat of metal primer with bus bar chamber comprising of high conductivity copper bus bar of capacity 160A three phase and half the capacity for neutral including voltmeter, Ammeter selector switches, PCC foundation suitable to accommodate the following as specified and as directed. Note One Nos of on load change over should be connected in series through bus bar for main supply and DG set.
31INCOMING(a) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp 01 nos(incoming) complete and all as per standard pratice -1 Job(b) MCCB 4 Pole, 415 V, Adjustable type, 150 Amps with breaking capacity 16 KA 1 Nos (INCOMING).
32OUT GOING(a) panel mounted on load Changeover 4 Pole, 415 V 100 Amps 1Nos (b) MCCB 4 Pole, 415 V, Adjustable type,63 Amps with breaking capacity 16 KA 3 Nos (c) MCCB 4 Pole, 415 V, Adjustable type,40 Amps with breaking capacity 16 KA 3 Nos (d) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard pratice-3 setNote :-(i) All MCCBs / instruments / MCBs /Bus Bar shall be housed in a separate housing with on - off latches in the housing and Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor (Incoming) and other parameters flush mounting with LED indication lamp for each outgoing complete and all as per standard practice.
33Supply and fix energy saving LED street light fittings,100 Watts or nearest higher wattage, with in-built electronic driver, IP 66 class of protection with versatile pressure die-cast aluminium housing parts, pure polyester powder coated dark gray housing, toughened glass cover with silicon gaskets and energy efficient LED 5700K connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed.Make: Crompton LSTS -90-CDL-M ( NEXUS NEO) or equivalent in Philips/Bajaj/ Wipro
34Supply and fix weather proof looping in box PVC without side dimension 160 x160x105 mm comprising of connector and MCB SP 6-32 A including mounting arrangements and lugs etc.and removing existing defective looping box and taken as credit complete all as specified and as directed. Make :Sintex/Hensel or as specified in PS
35Supply and fix new GI bracket made out of 25/32/40mm dia GI pipe length 1.2 mtr long bent to an angle 135 degree including two coats of aluminium paint over a coat of zinc chromate primer along with clamps, bolts, nuts etc including removing old unserviceable GI bracket complete all as specified.
36Supply and install APFC PANEL with MD-LX capacitor 50 KVAR with 6 steps ( 2+3+5+10+15+15) and MCCB of suitable capacity as incomer
37Supply and fix fire extinguisher dry chemical powder (ABC) Type , capacity 6 kg , as per IS 15683 , all as specified and as directed.
38Supply and fix fire extinguisher Mechanical foam extinguisher (stored pressure type) , capacity 9 ltrs , as per IS 15683 , containing 540 ml AFFF liquid ISI marked,IS 4989 part -II and polyurethane caoted CO2 gas cartridge ISImarked 4947 complete with gun metal,union cap, nylon hose with plastic foam making branch and wall mounting bracket all as specified and as directed.
39Miscellaneous items for External Water supply
40Supply, laying ,jointing and testing 2\\"/63 mm bore HDPE pipe, PE 63, PN 10 grade including fittings such as bends, socket, reducer, elbows, union etc in trenches complete all as specified and directed.
41Supply, laying ,jointing and testing 1\\"/32 mm bore HDPE pipe, PE 63, PN 10 grade including fittings such as bends, socket, reducer, elbows, union etc in trenches complete all as specified and directed.
42Open well submersible pump set multi stage 5 HP Single Phase 230 Volts 50 Hz head-30 mtr with all fittings and fixtures complete
43Supply and connecting flat three core, PVC insulated industrial cable for submersible motor, 6 sqmm (Nominal area) with multi stranded copper conductor, 1100 volts grade connected from starter to submersible pump motor complete all as specified and directed.
44Supply and Fix DOL Starter for Submersible Pump 5/7.5 HP
45DG Set
46Supply, Install , testing and commissioning of silent engine DG set of minimum Capacity 58.5 KVA, 415 Volts, Three Phase, 4 Wire, Engine as per IS – 10001 / 10002 and Alternator as per IS – 13364, conforming to CPCB-IV approved norms complete with AMF panel, Relay panel for automatic starting on main failure, control panel having meters, sound proof canopy as per relevant IS including PCC foundation etc. complete all as specified and as directed.
47Schedule \\"A\\" Part - XIII (Outsourcing of Maintenance and operation) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col. 5 siginifies this fact only. Contractor has to quote his own rate.
48Outsourcing for maintenance and operation of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 1st year after completion of defect liability period complete all as specified and directed.
49Outsourcing for maintenance and operation of sewage treatment plant of capacity 200 & 300 KLD installed at INS Chilka training area adjacent to each other for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 1st year after completion of defect liability period complete all as specified and directed.
50Outsourcing for maintenance and operation of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 2nd year after completion of defect liability period complete all as specified and directed.
51Outsourcing for maintenance and operation of sewage treatment plant of capacity 200 & 300 KLD installed at INS Chilka training area adjacent to each other for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant during 2nd year after completion of defect liability period complete all as specified and directed.
52Outsourcing for maintenance and operation of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 3rd year after completion of defect liability period complete all as specified and directed.
53Outsourcing for maintenance and operation of sewage treatment plant of capacity 200 & 300 KLD installed at INS Chilka training area adjacent to each other for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 3rd year after completion of defect liability period complete all as specified and directed.
54Schedule \\"A\\" Part - XIII (Comprehensive MaintenanceThis schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col. 5 siginifies this fact only.Note : Comprehensive mainteance include:(a) Repair/replacement of FAB media SBR/MBBR or any technology.(b) Repair/replacment of aur blower oil.(c) Repair/replacement of drives and other accessories of SCADA system for controlling operation of various motors.(d) Calibration of SCADA system including updation of softwares including replacement of necessary spares, checking relay contracts, replacement of relays, MCBs as per existing make and size, checking of alarm system to make it functional properly.(e) Repair/replacement of wornout/ unserviceable \\"V' belt for power transmission of air blowers.(f) Repair/replacement of defective MNX9 contactor AC3 rating 9 amps AC1 any rating with 1 NO + 1NC auxillary contracts.(g) Removing the old filtermedia and cleaning of internal walls of Dual media pressure filters at STP.
55(h) Repair/replacement of any Pumps and other machinery used in STP and repair/replacement of U/S NP2 pipes or CI/DI pipes.(j) M&L for collecting the samples from raw sewage sump and treater water sump monthly from STP i.e. before and after treatment, sample handling, transporting to NABL approved accredited laboratory to carry out the analysis of the following as per latest IS methods:(i) BOD (Biological Oxigen Demand)(ii) COD (Chemical Oxigen Demand)(iii) TSS (Total Suspended Solids)(iv) Fecal Coliform(v) Turbidity(vi) PH(vii) Total Nitrogen(viii) Total Phosphorous(ix) Total Ammonia Nitrogen
56Comprehensive maintenance of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 1st year after date of completion of defect liability period complete all as specified and directed.
57Comprehensive maintenance of sewage treatment plant of capacity 300 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 1st year after date of completion of defect liability period complete all as specified and directed.
58Comprehensive maintenance of sewage treatment plant of capacity 200 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 1st year after date of completion of defect liability period complete all as specified and directed.
59Comprehensive maintenance of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 2nd year after date of completion of defect liability period complete all as specified and directed.
60Comprehensive maintenance of sewage treatment plant of capacity 300 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 2nd year after date of completion of defect liability period complete all as specified and directed.
61Comprehensive maintenance of sewage treatment plant of capacity 200 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 2nd year after date of completion of defect liability period complete all as specified and directed.
62Comprehensive maintenance of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 3rd year after date of completion of defect liability period complete all as specified and directed.
63Comprehensive maintenance of sewage treatment plant of capacity 300 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 3rd year after date of completion of defect liability period complete all as specified and directed.
64Comprehensive maintenance of sewage treatment plant of capacity 200 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 3rd year after date of completion of defect liability period complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56976263
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 8.40 Crore
LAST DATE 09-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Provision Of Stps At Installation Chilka
Basic Detail
Tender No 82741
Bidding Type Tender
Location
City visakhapatnam
State Andhra Pradesh
Key Dates
Publish Date 12 Aug 2026
Submission Date 09 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value 8.40 Crore
Tender Fee 3000
EMD 7.45 Lakhs
Exemption Available
Document List
82741TenderSTP.pdf
BOQ_878659.xls
Drawings.pdf
prepriceschedulemerged.pdf
Tendernotice_1 (7).pdf
725e4a75-5019-4950-8d42-8093c3ce6993.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 25 days
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 32 days

Tender Documents

Download All (ZIP) ↓
pdf

82741TenderSTP.pdf

xls

BOQ_878659.xls

pdf

Drawings.pdf

pdf

prepriceschedulemerged.pdf

pdf

Tendernotice_1 (7).pdf

html

725e4a75-5019-4950-8d42-8093c3ce6993.html