| Sl. No. | Item Description |
| 1 | Taking out Copper / Aluminium Point wiring of any capacity and make from existing location including PVC fixed on roof/wall complete all as specified and directed. |
| 2 | M&L in repair modular point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral including new PVC casing caping / conduit on surface for mounting of modular switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. |
| 3 | All as per serial item No 2.00 here-in-before but for 5 amp modular socket on independent board complete all as specified and directed |
| 4 | All as per serial item No 2.00 here-in-before but for 5 amp modular socket on same board complete all as specified and directed |
| 5 | All as per serial item No 2.00 here-in-before but for size 2.5 sqmm for 15 amp modular socket on independent board complete all as specified and directed |
| 6 | M&L in repair point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral in existing PVC casing caping / conduit on surface for mounting of modular switches, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. |
| 7 | All as per serial item No 6 here-in-before but for 5 amp socket on independent board complete all as specified and directed |
| 8 | All as per serial item No 6 here-in-before but for 5 amp socket on same board complete all as specified and directed |
| 9 | All as per serial item No 6 here-in-before but for size 2.5 sqmm for 15 amp modular socket on independent board complete all as specified and directed |
| 10 | Supply and fix modular switch , 1 way 6 Amp 1 module singe pole one way complete all as specified and directed |
| 11 | Supply and fix modular switch , 1 way 16 Amp 1 module singe pole one way complete all as specified and directed |
| 12 | Supply and fix modular socket outlet 2/3 pin, 16 amp, 2 module complete all as specified and directed. |
| 13 | M&L in repair modular white cover outer plate/frame and metal flush box, 8 module complete all specified and directed by Engr - in Charge |
| 14 | M&L in repair modular white cover outer plate/frame and metal flush box, 6 module complete all specified and directed by Engr - in Charge |
| 15 | M&L in repair modular white cover outer plate/frame and metal flush box, 3 module complete all specified and directed by Engr - in Charge |
| 16 | M&L in repair modular white cover outer plate/frame and metal flush box, 1/2 module complet all specified and directed by Engr - in Charge |
| 17 | Supply and fix modular Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed. |
| 18 | Supply and fix Switch Piano,flush type 6 Amp single pole,oneway complete all as speciifed and as directed |
| 19 | Supply and fix outlet socket 3 pin 16 amp fllush type compelete all as specified and directed. |
| 20 | Supply and fix Switch Piano,flush type 16 Amp single pole,oneway conforming to IS-3854 complete all as speciifed and as directed |
| 21 | Supply and fix Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed. |
| 22 | S&F in repair Recess mounting type fitting LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 36 watt (cool white), minimum system lumen efficacy not less than 80 % , CRI not less than 80, colour temperature not less than 6000 K, power factor not less than 0.95, LED driver with constant output voltage and current at input voltage of 140 volt to 285 volt AC, 50 HZ, Surge Protection>2 KV, IP protection IP 20, powder coated housing with ashthetic bottom frame, with excellent heat dissipation through high thermal conductivity, high efficiency transulence diffuser, suitable for any type of ceiling system including connection with PVC insulated copper conductor 3 core cable of 0.50 sqmm complete all as specified. Make Havells / crompton / Philips / Bajaj / Wipro |
| 23 | Supply and fix in repairs LED Tube lights fitting Four feet 1 x 20 Watt LED Up-Down Batten(Yellow uplight relax mode and white downlight work mode), 220V AC, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. (CAT PART NO: PHILIPS TWINGLOW 20W GU24)./ Havells / Crompton / Bajaj / Wipro |
| 24 | Supply and fix in replacement of LED lights fitting Two feet 1x 10 Watt LED 6500 K, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete inc taking down all as specified and directed by Engr-in-Charge. Make Havells / crompton/ Philips |
| 25 | Supply, installation, testing and commissioning in repair of decorative wall light complete with powder-coated metal body, E27 lamp holder, wall mounting base, internal wiring, fixing screws, raw plugs, connector strip and all accessories required for complete installation. The fitting shall be mounted on wall/column as directed by the Engineer-in-Charge. LED lamp (if required), wiring from nearest junction box to the fitting, conduit and switch shall be measured and paid separately unless otherwise specified. including taking down old unsv tubelight Make: Philips cat no Muziris / Crompton/ havells |
| 26 | Supply, Installation, Testing and Commissioning of LED Bedside Wall Light, wall-mounted type, complete with integrated LED (3 W or approved equivalent), flexible gooseneck reading arm, individual ON/OFF switch, die-cast aluminium/metal body with grey/black finish, electronic driver, mounting plate, internal wiring, fixing screws, rawl plugs and all accessories required for complete installation. The fitting shall be suitable for operation on 230 V AC, 50 Hz and installed as directed by the Engineer-in-Charge. inc taking down old unsv tube light Make: Philips / Crompton/ havells |
| 27 | Supply only E27 bulb of warm white / CDL of minimum wattage of 9 watt for item ser no. 25, all as specified and directed by Engr-in-Charge. |
| 28 | Supply and fix in replacement of 40 watt LED lights fitting four feet LED 6500 K, 220V AC, 50 Hz, complete with Led driver, decorative surface mounted LED lighting fixture with polycarbonate environmental friendly, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete inc taking down all as specified and directed by Engr-in-Charge. Make Havells / crompton/ Philips Cat no. Starbright |
| 29 | Supply, installation, testing and commissioning of 8-way IP65 weatherproof distribution box, surface mounted, complete with transparent hinged cover, gasket, DIN rail, neutral and earth bars, suitable incomer SPN, outgoing MCBs, busbar/comb busbar, internal wiring, ferrules, circuit labels and all necessary accessories, complete in all respects. suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: Hensel / L&T/ Schneider/ Legrand/ ABB/Havells] Note : Cable Glands , MCB SP/SPN will be measured and paid seperately under respective schedule. |
| 30 | M&L for in repair in repairs MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. |
| 31 | M&L for in repair MCB SP 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. |
| 32 | M&L Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface cashing capping, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed.Make of conductor : Havells/polycab/KEI Note: Two runs each of 10 sqmm cable & one RM of 10 sqmm cable as earth wire shall be considered as one RM for payment purpose. |
| 33 | M&L Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.0 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.0 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC concealed conduit, heavy duty and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 6.0 sqmm cable and one RM of 6.0 sqmm cable as earth wire shall be considered as one RM for payment purpose. |
| 34 | M&L Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.0 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.0 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC concealed conduit, heavy duty and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 4.0 sqmm cable & one RM of 4.0 sqmm cable as earth wire shall be considered as one RM for payment purpose. |
| 35 | M&L Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 2.5 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 2.5 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC concealed conduit, heavy duty and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 2.5 sqmm cable and one RM of 2.5 sqmm cable as earth wire shall be considered as one RM for payment purpose. |
| 36 | M&L in repair rigid non-metallic PVC conduit of dia not less than 20 mm including of boxes (junction/terminal) all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, fixing on roof/wall including fixing arragement like saddledd and other material complete all as specified and directed. |
| 37 | M&L in repair point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through new PVC Casing Caping / conduits concealed with sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chasis to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. |
| 38 | All as per serial item No. 37 here-in-before but for size 1.5 Sqmm on Independent board complete all as specified and directed |
| 39 | All as per serial item No. 37 here-in-before but for size 1.5 Sqmm on same board complete all as specified and directed |
| 40 | All as per serial item No. 37 here-in-before but for size 2.5 sqmm for 15 amp socket on ind board complete all as specified and directed |
| 41 | M&L in repair point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through existing PVC Casing caping / conduit on surface with sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. |
| 42 | All as per serial item No. 41 here-in-before but for size 1.5 Sqmm on Independent board complete all as specified and directed |
| 43 | All as per serial item No. 41 here-in-before but for size 1.5 Sqmm on same board complete all as specified and directed |
| 44 | All as per serial item No. 41 here-in-before but for size 2.5 sqmm for 15 amp socket on ind board complete all as specified and directed |
| 45 | Supply and fix Switch Piano,flush type 6 Amp single pole,oneway conforming to IS-3854 complete all as speciifed and as directed |
| 46 | Supply and fix outlet socket 3 pin 6 amp fllush type compelete all as specified and directed. |
| 47 | Supply and fix outlet socket 3 pin 16 amp fllush type compelete all as specified and directed. |
| 48 | Supply and fix Switch Piano,flush type 16 Amp single pole,oneway conforming to IS-3854 complete all as speciifed and as directed |
| 49 | Supply and fix Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed. |
| 50 | S&F in repair of Building security LED street light fitting 35 Watt 6500K pf >.90 efficency 100lm/W 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp fixing of wall,pole,building with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection complete all as specified and as directed. |
| 51 | S&F in repair Street light bracket made out of 32/40 mm dia GI light grade tubing not less than .75 Mtr long bend to shape including pole clamps/fastners clips nails made out flat iron and nuts, bolts and washers etc complete all as specified and directed. |
| 52 | S&F sheet steel powder coated distribution board SPN 4 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB] |
| 53 | S&F sheet steel powder coated distribution board SPN 8 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB] |
| 54 | S&F sheet steel powder coated distribution board SPN 12 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB] Note on Item No 52 to 54 : MCB SP/SPN will be measured and paid seperately under respective schedule. |
| 55 | Supply only LED lights fitting Four feet 1 x 20 Watt LED 6500K /4000 K / 3000 K , 3 in 1 mode of operation , 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make Havells / crompton/ Philips |
| 56 | M&L in repair MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. |
| 57 | M&L in repair MCB SP 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. |
| 58 | Supply and fix factory made V TPN DBs-DPX-160 MCCB DB's, IP-43 protection-IK09 with metal double door with 160 Amps copper busbar with 2 neutral busbar, earth bar cables ties for cable management fully insulated busbar with set of wires and door earthing for provision of DPX 160 MCCB as incomer and included with SP/TP MCB's as outgoing 4 way DPX 3 160+12 etc including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB] |
| 59 | Supply and fix factory made V TPN DBs-DPX-250 MCCB DB's, IP-43 protection-IK09 with metal double door with 160 Amps copper busbar with 2 neutral busbar, earth bar cables ties for cable management fully insulated busbar with set of wires and door earthing for provision of DPX 160 MCCB as incomer and included with SP/TP MCB's as outgoing 4 way DPX 3 250+12 etc including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB] Note on Item No 58 to 59 : MCCB will be measured and paid seperately under respective schedule. |
| 60 | Supply and fixing MCCBs 250 Amps capacity, DPX-250 415 volts, 4 pole, 25 KA, thermal magnetic complete all as specified and directed Make Legrand/Siemens/Schneider |
| 61 | Supply and fixing MCCBs 160 Amps capacity, DPX-160 415 volts, 4 pole, 25 KA, thermal magnetic complete all as specified and directed Make Legrand/Siemens/Schneider |
| 62 | Supply and fixing MCCBs 100 Amps capacity, DPX-100 415 volts, 4 pole, 25 KA, thermal magnetic complete all as specified and directed Make Legrand/Siemens/Schneider |
| 63 | Supply and Fix MCCB TPN 415 Volts, 100 Amps, 50 Hz, 16 KA 'C' series allas specified and directed Make Legrand or eqv Siemens/Scheinder |
| 64 | Supply and Fix MCCB TPN 415 Volts, 63 Amps, 50 Hz, 16 KA 'C' series allas specified and directed Make Legrand or eqv Siemens/Scheinder |
| 65 | Supply and fix in replacement of LED lights fitting Four feet 1x 20 Watt LED 6500K, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down all as specified and directed by Engr-in-Charge. |
| 66 | Supply and fix in replacement of LED lights fitting Two feet 1x 10 Watt LED 6500 K, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down all as specified and directed by Engr-in-Charge. |
| 67 | Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked of size 35 Sq.mm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed.Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engineer-in-Charge before the cable is laid. (ii) Excavation & earth work will be measured and paid separately. |
| 68 | All as per item No 67 hereinbefore of size 25 Sq.mm 3.5 core complete all as specified and directed. |
| 69 | Supply only PVC insulated and unsheathed copper wire of size 1.5 sqmm (nominal area) ISI marked multi-stranded FRLS copper conductor single core in different colour complete all as specified and directed [ Make of cable - Finolex / Havell's / Anchor/KEI ] Note : Length of roll shall not less than 90 Mtr |
| 70 | Supply only PVC insulated and unsheathed copper wire of size 2.5 sqmm (nominal area) ISI marked multi-stranded FRLS copper conductor single core in different colour complete all as specified and directed. [ Make of cable - Finolex / Havell's / Anchor/KEI ] Note : Length of roll shall not less than 90 Mtr |
| 71 | Supply only PVC insulated and unsheathed copper wire of size 6.00 sqmm (nominal area) ISI marked multi-stranded FRLS copper conductor single core in different colour complete all as specified and directed.[ Make of cable - Finolex / Havell's / Anchor/KEI ] Note : Length of roll shall not less than 90 Mtr |
| 72 | Supply only PVC insulated and unsheathed copper wire of size 10.00 sqmm (nominal area) ISI marked multi-stranded FRLS copper conductor single core in different colour complete all as specified and directed. [ Make of cable - Finolex / Havell's / Anchor/KEI ] Note : Length of roll shall not less than 90 Mtr |
| 73 | Supply only 15 Amps switch complete all as specified and as directed |
| 74 | Supply only 15 Amps socket complete all as specified and as directed |
| 75 | Supply only 5 Amps switch complete all as specified and as directed |
| 76 | Supply only 5 Amps socket complete all as specified and as directed |
| 77 | Supply only Modular 15 Amps switch complete all as specified and as directed |
| 78 | Supply only Modular 15 Amps socket complete all as specified and as directed |
| 79 | Supply only Modular 5 Amps switch complete all as specified and as directed |
| 80 | Supply only Modular 5 Amps socket complete all as specified and as directed |
| 81 | M&L Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using GI earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site complete all as specified and directed. |
| 82 | M&L Earthing complete with Copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using Cu earth strip of size 25 x 3 mm as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site complete all as specified and directed. |
| 83 | Material and Labour for earth continuity conductor or main galvanised iron wire of size 4.00 mm burried in ground, fixed to wall, any other indicated situation for loop earthing and the like upto test point on necesarry insulators and fastning screws, rawl plugs complete all as specified and directed. |
| 84 | Material and Labour for earth continuity conductor or main galvanised iron strip of size 32 x 6 mm burried in ground, fixed to wall, any other indicated situation for loop earthing and the like upto test point on necesarry insulators and fastning screws, rawl plugs complete all as specified and directed. |
| 85 | Material and Labour for earth continuity conductor or main copper strip of size 20 x 3.15 mm burried in ground, fixed to wall, any other indicated situation for loop earthing and the like upto test point on necesarry insulators and fastning screws, rawl plugs complete all as specified and directed. |
| 86 | Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and LT cable and getting out, , complete all as specified and directed by Engineer-in-Charge |
| 87 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed by Engineer-in-Charge |
| 88 | Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed by Engineer-in-Charge |
| 89 | M&L for dry sand cushioning to underground cables complete all as specified and directed.Note : Only punned thickness i.e. 18 CM shall be measured and paid. |
| 90 | M & L for sub class 'B' brick for covering to under ground cable laid flat transversally width equal to the length of the cable complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender