Tender For Special Repair To Roof Treatment Of Certain Smqs And Otm Accn At Afssr Under Ge (Af) Gurgaon
Tender Value
86.96 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
17 days left
EMD
1.55 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Roof Treatment Of Certain Smqs And Otm Accn At Afssr Under Ge (Af) Gurgaon
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of bricks (laid flat or on edge) or brick tiles laid dry and pointed in any mortar in floors, channels, kerbs, aprons, over roof surfaces etc. in each layer complete all as specified and directed.Note : Rates are included upto G+4 Storey |
| 2 | Taking down existing damaged APP membrane and clean the surface , frost, surface laitance and contamination and free from loose aggregate, clean with water complete all as directed by Engr-in-Charge.Note:Rates are included upto G+4Storey |
| 3 | Material and labour for providing plain cement concrete with Nano filler 1: cement 1: sand 2: agregate 4 type B1 using 20mm graded stone aggregate as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and as directed.Note : (i) Minimum thickness of PCC shall be 30mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after.(ii) PCC shall be laid to acheive true slope towards the drain/weep holes. |
| 4 | Material and labour for applying a coat of Nano technology based water proofing compound (1 part powder : 1 part liquid), of desired consistency with nylon brush @ 5 sqm/kg coverage over vertical/horizantal surface of RCC roof and parapet complete all as specified and directed. |
| 5 | M&L Water Proofing given below complete all as specified and directed.a) Surface Preparation - Mild Chipping of the surface, Clean the Surface with Nano Bio wash.b) If onlinr leackage found seal with Nano magic and apply nano Bond coat.Open the cracks by making ‘V’ groove, filling cracks with Nano Crack Filler.c) Aplly Nano carbon baesed shorter chain Nano Bond Coat d) Providing and applying Nano Water Base Water Proof compound one coats after surface preparation using brush, not containing toxic materials like Pb, Cr, Zn; having defect-free nano-particles with inhibiting characteristics having bacteria killing rate above 98% and anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 75degree , permeable type with elongation (stretch ability) of more than 300%, in a nano-structured self assembled dispersion system with VOC level of less than 1% , 60 micron DFT.e) If ant crack found open and fill the crack with nano carbon base filler and bond coat.and use nano wall filler to reduce the undulation.f) Apply Nano high penetration Bond coat two coat.g) Providing and applying Nano Barrier Coat Paint/ Nano Water Base Water Proof Paints 2 coats over screed concrete using brush, not containing toxic materials like Pb, Cr, Zn; having defect-free nano-particles with inhibiting characteristics having bacteria killing and anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 750 , with elongation (stretch ability) of more than 300%, in a nano-structured self assembled dispersion system with VOC level of less than 1% , 60 micron DFT per coat. |
| 6 | Supply only Liquid Integral Water Proofing Compound, ISI Marked, as approved, complete all as specified and as directed. |
| 7 | Demolition of brick work , built in cement mortar or cement lime mortar including all quions, arches, pillars, etc. Including removing complete all as specified and directed. (Note : Rates are included upto G+4 Storey) |
| 8 | Taking down cement plaster including raking out joints hacking for key scrubbing down with water etc and removing rubbish complete all as specified and directed . Note : Rates are included upto G+4 Storey |
| 9 | Taking up or down Steel Tubing 15mm bore (dia) with Fittings/ Connections, segregating Serviceable Pipes and Fittings/ Connections and keep in Safe Custody for re-use, complete all as specified and as directed.Note : Rates are included upto G+4 Storey |
| 10 | Taking up or down Steel Tubing 20mm bore (dia) with Fittings/ Connections, segregating Serviceable Pipes and Fittings/ Connections and keep in Safe Custody for re-use, complete all as specified and as directed.Note : Rates are included upto G+4Storey |
| 11 | M&L Brick Work with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.Note : Rates are included upto G+4 Storey |
| 12 | M&L Rendering (External) 15mm thick in Cement Mortar 1:4 on Brick Walls/Concrete Surfaces upto double storey, mixing with WPC as per Manufactures instruction, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed.Note : Rates are included upto G+4 StoreyNOTE : WPC shall be Measured and Paid for as ‘Supply only’ separately under appropriate Item. |
| 13 | Supply only Integral Water Proofing Compound, ISI Marked, as approved, complete all as specified and as directed. |
| 14 | M&L Rendering (Internal) 15mm thick in Cement Mortar 1:6 on Brick Walls/Concrete Surfaces upto double storey, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed.(Note : Rates are included upto G+4 Storey) |
| 15 | M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces on ceiling/ struts in CM 1:3. finishing even and smooth without using extra cement complete all as specified and directed. |
| 16 | S&F 15mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 17 | S&F 20mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 18 | Refixing old 15 mm steel tubing and connection in nnew or old position (walls ceiling, floor etc) complete all as specified and directed. |
| 19 | Refixing old 20 mm steel tubing and connection in nnew or old position (walls ceiling, floor etc) complete all as specified and directed. |
| 20 | Taking down PVC/cast iron pipes any bore including fittings of any dia with cement or lead joint fixed to walls or laid in trenches complete for refixing or replacement complete all as specified and directed by Engineer-in-Charge. |
| 21 | S&F 75 mm bore cast (spum) iron waste & vent pipe epoxy coated inside & out side fixed to wall vertically / laid in floors complete all as specified and directed by Eng-in-Charge. |
| 22 | S&F in 100 mm bore cast (spum) iron waste & vent pipe epoxy coated inside & out side laid in trenches or in floors / fixed to wall vertically complete all as specified and directed by Eng-in-Charge. |
| 23 | S&F in repair 75 mm cast iron cowls complete all as specified and as directed |
| 24 | S&F in repair 100 mm cast iron cowls complete all as specified and as directed |
| 25 | S&F in repair 75 mm bore cast (spum) iron bend or required degree with epoxy coated inside & out side complete all as specified and directed by Eng-in-Charge. |
| 26 | S&F in repair 75 mm bore centrifugally cast (spum) iron tee with access door or required degree with epoxy coated inside & out side complete all as specified and directed by Eng-in-Charge. |
| 27 | S&F in repair 100 mm bore centrifugally cast (spum) iron bend or required degree with epoxy coated inside & out side complete all as specified and directed by Eng-in-Charge. |
| 28 | S&F in repair 100 mm bore centrifugally cast (spum) iron tee or required degree with access door epoxy coated inside & out side complete all as specified and directed by Eng-in-Charge. |
| 29 | M&L preparing old Decorated/Treated Plastered surfaces of Walls by Complete Removal of existing Treatment and by applying Wall Putty, cutting/ rubbing to obtained a Smooth Surface and applying Two Coats of Weather Coat Exterior Paint with approved Tint over a coat of Primer (as per Manufacturer's instructions), complete all as specified and as directed. |
| 30 | M&L preparing old Distempered surfaces of Walls/ceiling by brooming down or steel wire brushing and scraping down and filling the existing Nails/ Screw Holes, etc. and applying Two Coats of Distemper Oil Emulsion (as approved), complete all as specified and as directed. |
| 31 | M&L preparing new plastered surfaces of Walls / celling by brooming down or steel wire brushing and scraping down and filling the existing Nails/ Screw Holes, etc. and applying Two Coats of Distemper Oil Emulsion (as approved), complete all as specified and as directed. |
| 32 | M&L preparing new plastered surface applying Two Coats of Weather Coat Exterior Paint with approved Tint over a coat of Primer (as per Manufacturer's instructions), complete all as specified and as directed. |
| 33 | M&L Rotational Moulded Polyethene Water Storage Tank 500 Litre Capacity, Cylindrical, Vertical with Closed Top, 3 layered, hoisted and fixed in Position all as specified in MES Schedule including dismantling/ lowering down unserviceable Water Storage Tanks, complete all as specified and as directed.Note : Rates are included upto G+4 Storey+B54 |
| 34 | Disconnecting existing tanks of capacity 500 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. |
| 35 | M&L for cleaning and removing all scale and dirt etc from tank capacity 500 ltr and from mouths of circulating pipes, etc complete all as specified and directed. |
| 36 | S&F in repair Gun Metal Gate Valve 20mm bore (dia) with Iron Wheel Head including Flange, screwed both Ends for Iron Pipe and fixed-in-repairs, complete all as specified and as directed. |
| 37 | S&F in repair Ball Valve 20mm dia (minimum Weight 210 Gram), high pressure of PTMT with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe and fixed-in-repairs, complete all as specified and as directed. |
| 38 | M&L reparing of RCC projection, chajja, roof facia 150-300mm by scrapping, cutting, derusting and cleaning exposed reinforcement surfaces of damaged loose RCC surface and applying neat cement slurry @ 3 kg/Sqm and filling the surface with cement plaster 1:3 one or two layer as reqd and also used chicken wire mesh as reqd with or without facia and smooth finished incl two coats of finished to match with the existing surface at any height and in any situation including necessary form work complete all as specified and directed. Note : Rates are included upto G+4 Storey |
| 39 | Net Contract Sum will be after deducting Sch of Credit of Rs 1,42,203.00 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender