Tender For Addition/ Alteration To Bldg No. P-58 Of Hq Cif(K) Under Age (I) Cif (K)
Tender Value
9.57 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
3 days left
EMD
19140
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Addition/ Alteration To Bldg No. P-58 Of Hq Cif(K) Under Age (I) Cif (K)
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering, complete all as specified and directed by the Engineer-in-Charge. |
| 2 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated profile steel sheet 0.50mm thick of colour as approved by AGE(I), having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by the Engineer-in-Charge. |
| 3 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of colour as approved by AGE(I), having tensile strength of 550 Mpa as in roof covering/cladding to ridges, valley gutters etc. fixed with self tapping screws, complete all as specified and as directed by the Engineer-in-Charge. |
| 4 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by the Engineer-in-Charge. |
| 5 | Non skid ceramic coloured tiles 1st quality 7 to 8mm thick, (square/ rectangular), area of each tile exceeding 0.18sqm, but not exceeding 0.38sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account. |
| 6 | Non skid ceramic coloured tiles 1st quality 7 to 8mm thick, (square/ rectangular), area of each tile exceeding 0.18sqm, but not exceeding 0.38 sqm as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick rendering in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account. |
| 7 | M&L for chequered cement concrete coloured tiles of size 30 cm x 30 cm x 25mm thick set, jointed and pointed in neat cement slurry in floors,with grey cement and pigment, laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in copings, weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by the Engineer-in-Charge. |
| 9 | Demolition of cement concrete un reinforced in ground floors and pavings not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed by the Engineer-in-Charge. |
| 10 | M&L for Plain cement concrete 1:3:6 type C2 using 40mm graded crushed stone aggregate, 75 mm thick as in plinth protection/ pathway laid in alternate bays (n exc 2 Sqm each) and finished even and fair without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and as directed by Engineer-in-Charge. |
| 11 | M&L for preparing old plastered or unplastered surfaces of walls for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces complete all as specified and directed. |
| 12 | M&L for 25 mm bore, 3- layer PPR (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having therrnal slability for hot & cold water supply all PPR plain & brass threaded polypropylene random fittings, laid in trenches or in floors or in ceiling and fixed to walls, complete all as specified and as directed by the Engineer-in- Charge. |
| 13 | M&L for 32 mm bore, 3- layer PPR (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having therrnal slability for hot & cold water supply all PPR plain & brass threaded polypropylene random fittings, laid in trenches or in floors or in ceiling and fixed to walls, complete all as specified and as directed by the Engineer-in- Charge. |
| 14 | Lagging to pipes of 20 to 32mm bore, used in internal water supply or plumbing all round with, 25mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg /cum conforming to IS 9842 provided with chicken mesh wire netting 25 gauge, 20mm mesh, covering with POP layer, complete all as specified and directed at site by the Engineer -in-Charge. |
| 15 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc,; and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good, cutting not exc. 10cm girth in brick/stone walls, complete all as specified and directed by the Engineer-in-Charge. |
| 16 | S&F Vitreous China, wash hand basin, flat back white of size 550mm x 400mm including brackets, brass CP waste coupling 32mm dia with long screwed shank and fly nuts, 32mm dia PVC waste pipe, chain and plug, porcelain stopper including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs, complete all as specified and directed by Engineer-in-Charge. |
| 17 | S&F Looking mirror 600mm x 450mm bevelled edge mirror 2mm thick of selected quality glass mounted on 4mm thick PVC sheet and with aluminium frame work fitted with chromium plated brass screws and cup washers, complete all as specified and directed by Engineer-in-Charge. |
| 18 | S&F Bib taps, 15mm bore, cast copper alloy, chromium plated, with crutch or butter fly handle, screwed down, screwed for iron pipe, or brass ferrule , complete all as specified and directed by Engineer-in-Charge. |
| 19 | S&F Pillar taps, 15mm bore, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered `Hot’ or `Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and directed by Engineer-in-Charge |
| 20 | S&F Stop valves/angle valve 15mm bore, fancy type with long shank and cup, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed by Engineer-in-Charge |
| 21 | S&F PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified and directed by Engineer-in-Charge. |
| 22 | S&F tubular towel rail aluminium anodised 20 mm dia, D type, 60 cm long with brackets complete all as specified and as directed by the Engineer-in-Charge. |
| 23 | S & F harrison rail/curtain rail, mild steel chromium plated with fixed brackets, stops,rollers etc complete all as specified and as directed by the Engineer-in- Charge. |
| 24 | Taking down chowkat or frames with shutters (without taking off shutters from the frames) area n.exc 1.5 Sqm each including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost) , complete all as specified and directed by the Engineer-in-Charge. |
| 25 | S&F in position powder coated anodised aluminium three track sliding window (minimum thickness of powder coating 50 micron) of exturded modular and anodised approved colour, shade and finish aluminum section of Jindal or equivalent approved make and size of frame/rails 92mmx31.75mmx1.9mm thick (Wt not less than 1.174 Kg/Rm). The shutter comprising of bearing bottom and top of size 48mmx20mmx1.30mm thick (wt not less than 0.539 kg/Rm) interlocking section of size 50mmx29mmx1.28mm thick (wt not less than 0.594 Kg/Rm) and hand sides of 50mmx20mmx1.5mm thick (wt not less than 0.571 Kg/Rm) including fixing of 5mm thick clear black plain glass of saint Gobain or equiavalent make in two shutter and stainless steel wire cloth 0.36mm nominal dia of wire, averaging width of aperature 1.4mm fixed in one shutter including approved quality neoprene gasket, bottom roller, fixtures, fastenings, and accessories like PVC taflon bearing of MITI or approved made, 6\\" star locks, sainless steel screws,joining cleat for fixing etc complete all as specified and directed. NOTE:- The rate is inclusive of cost of 5mm thick plain sheet glass and stainless steel wire cloth. |
| 26 | Dismantling wall and ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and as directed by the Engineer-in-Charge. |
| 27 | S&F 15mm thick 2nd class soft wood clean sawn boarding as in eaves board fixed with nails in any situation complete all as specified and directed by Engr-in charge. |
| 28 | M&L for GI frame work size of grid 605 x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from sofit at approx 900 mm centre to centre with GI cleat and steel expansion fasterner with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips acress the intermediate channel at 457mm centre to cnetre including hangers 6mm dia.GI (upto 1200mm length) adjusting level fixed tp roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm ling and expansion hold fasterner 12.5mm dia 40mm long including 12mm thick gypsum board of size 600mm x 600mm as in ceiling fixed on GI frame work, complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F framed work such as grills, gates and intricated design including MS angle, flat iron, round bars, MS plate, gratings with ends of bars shouldered on forged in spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, rallings, framework of water tanks and similar work including welding of Gde Fe 290, Gde-E-165, complete all as specified. |
| 30 | M&L for preparation of newly untreated steel or iron surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed by the Engineer-in-Charge. |
| 31 | M&L for preparation of old painted wood surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by the Engineer-in -Charge. |
| 32 | M&L for brick work with sub class `B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, complete all as specified and directed by the Engineer-in-Charge. |
| 33 | Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed by the Engineer-in-Charge. |
| 34 | M&L for Vitrified Ceramic tiles (Light shade/ Double charged/ Ultra charged) 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1 sqm, as in skirting/ vertical surface, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over 10mm thick remdering/cement plaster in cement mortar 1:4, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account. |
| 35 | M&L for preparation of new plastered / unplastered surfaces of walls and applying two coats of oil bound distemper over 3mm thick wall care putty, complete all as specified and as directed by Engineer-in-Charge. |
| 36 | Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, surface finished even and smooth without using extra cement, complete all as specified and directed by the Engineer-in-Charge. |
| 37 | M&L for preparing new plastered surfaces of walls for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces complete all as specified and directed. |
| 38 | S&F Vitreous China Water closet one piece of \\" size (WxPxH) 365x650x760mm white with 'P' or 'S' trap, Model- LAUREN of Make - Somany Bathware, or of equivalent item of Make- JAQUAR, ESSCO,PARKO, ORIENT etc as approved by Engineer in charge. |
| 39 | S&F PVC (SWR) pipes, 110mm dia, single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by the Engineer-in-Charge. |
| 40 | S&F PVC (SWR) pipes, 75mm dia, single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by the Engineer-in-Charge. |
| 41 | S&F PVC (SWR) bends (any radius), 110mm bore, with or without access door, complete all as specified and as directed by the Engineer-in-Charge. |
| 42 | S&F PVC (SWR) bends (any radius), 75mm bore, with or without access door, complete all as specified and as directed by the Engineer-in-Charge. |
| 43 | S&F PVC (SWR) vent cowl, 110mm bore, complete all as specified and as directed by the Engineer-in-Charge. |
| 44 | S&F PVC (SWR) 75mm bore floor trap, plain with grating including jointing with solvent cement, complete all as specified and as directed by the Engineer-in-Charge. |
| 45 | Taking down chowkat or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n.exc 4 Sqm each including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost), complete all as specified and as directed by the Engineer-in-Charge. |
| 46 | S&F 10mm thick toughened glass as in hinged door, partition, automatic doors and similar work including cutting shape, drilling holes, grinding/polishing and rounding off edges of glass, including providing and fixing door handle , hinges, hydraulic foundation of ISI marked and other fixing arrangment required etc, complete all specified and directed by Engr-In-Charge. |
| 47 | M&L for RCC (nominal mix) type B0 1:2:4 (using 12.5mm graded crushed stone aggregates) as in tie beams, gabble beams, cantilevers, bressummers, lintels over 1.5m span etc, complete all as specified. |
| 48 | M&L for TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips, etc., complete |
| 49 | M&L for TMT bars 5mm dia and over, upto and including 10mm dia as in stirrups, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips, etc., complete |
| 50 | Use and waste of formwork for rough finished surface of concrete to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including suports, overhanging etc, complete all as specified. |
| 51 | M&L for RCC (nominal mix) type B1 1:2:4 (using 20mm graded crushed stone aggregates) as in foundations, including rafts, footing, foundation beams, plinth beams, bases for columns etc, basement slabs, under reamed piles and mass concrete, complete all as specified. |
| 52 | M&L for RCC (nominal mix) type B1 1:2:4 (using 20mm graded crushed stone aggregates) as in columns, complete all as specified. |
| 53 | M&L for PCC type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified. |
| 54 | M&L for PCC type D2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete (flooring), complete all as specified. |
| 55 | M&L for filling under floors with available earth including spreading levelling in layers not exceeding 25cm thick, well ramming and watering as required. |
| 56 | M&L for hardcore of gauge not exceeding 63mm deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to true surface with broken stones and boulders, complete all as specified. |
| 57 | S&F 2nd class soft wood boarding, 15mm thick, as in wall panelling, plain one side and edges tongued and grooved or rebated, fixed with nails in any situation including french polishing on surface of any description width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coat upto satification of Engr-In-Charge. |
| 58 | S&F Anodised aluminium frame (powder coated minimum thickness of powder coating 50 micron) for doors, windows, partition wall with one or more rebates including joining cleat for fixing, rubber packing, anodised aluminium snap on beading for fixing glass panes in frame etc complete all as specified and directed. |
| 59 | M&L 4mm thick aluminium composite sheet with decorative colour and fixed with screw or aluminium beading to aluminium frame complete all as specified and as directed by the Engineer-in-Charge. |
| 60 | S&F plain sheet glass, 5 mm thick, selected quality and glazing with oil putty in squares exceeding 0.5 Sqm in each pane complete all as specified and as directed by the Engineer-in-Charge. |
| 61 | Taking down old unservicable point wiring including fittings & fixtures and making good of the surface to match with the existing including touch up of paint/white wash to the disturbed surface of the wall / ceiling,etc., complete all as specified and directed by Engineer- in-charge. |
| 62 | M&L for point wiring with 1.5 sqmm (nominal cross section area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in including PVC rigid non metalic 25 mm dia or PVC casing caping including MS sunk box 3 mm thick hylum sheet top cover fixed by means of brass machine screw and cap washer including size 1.5 sqmm (nominal cross secrional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuty conductor connected to main switches/DBs or common earth dolly complete all as specified and as directed for one light point or one fan point controlled by one one way switch with cable 1.5 sqmm size. |
| 63 | All as per item No 62 above but one 3/5 pin switch socket 5/6 Amps on same board. |
| 64 | All as per item No 62 above but one 3/5 pin switch socket 5/6 Amps on Independent board. |
| 65 | All as per item No 62 above but for one bell/buzzer point controlled by one bell switch complete all as specified by Engr-in-Charge. |
| 66 | All as per item No 62 above but one 3/5 pin switch socket 15/16 Amps on same board with using 2.5 sqmm PVC insulated multi stranded copper conductor with 2.5 sq mm earth continuity conductor for same board. |
| 67 | All as per item No 66 here-in -before but using 4 sqmm PVC insulated multi stranded copper conductor with 4 sq mm earth continuity. conductor for independent switch socket out let 5 pin 5/15 Amps point. |
| 68 | M&L for replacement of sub main wiring with two run of 6 Sqmm single core, PVC insulated but unsheathed multi-stranded copper conductor, 1100 volts grade drawing through and including PVC conduit of 25 mm dia concealed type with all accessories and 6 sqmm PVC insulated but unsheathed multi-stranded copper conductor cable as earth continuity wire including taking down old submain wiring complete all as specified and directed. Note: Two run of PVC cable with one run of PVC conduit and one run of PVC earth wire shall be measured and paid as one length only. |
| 69 | M&L in replacement through pipe, 1100V, grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core, 16 Sq mm nominal cross section in service connection. |
| 70 | Supply and fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket completa with one single pole MCB 20Amp complete all as specified and as directed by yhe Engineer-in-Charge. |
| 71 | Supply and fixing bell, AC, 230 Volt single pole. |
| 72 | Supply and fixing modular switch piano flush type single pole one way 6 amps. |
| 73 | Supply and fixing modular switch piano flush type single pole one way 16 amps. |
| 74 | Supply and fixing modular bell push , flush type 6 Amps, 1 module. |
| 75 | Supply and fix modular socket 6 Amp, 2/3 pin combined 2 module. |
| 76 | Supply and fix modular socket 16 Amp, 2/3 pin combined 2 module. |
| 77 | Supply and fix modular fan regulator 120w - 2 module. |
| 78 | Supply and fixing PVC batten/angle holder including connection etc. as required. |
| 79 | S&F 3 pin 5 Amp ceiling rose on the existing junction box/wooden block including connection as required. |
| 80 | Supply and fix white cover plate 4 module. |
| 81 | Supply and fix white cover plate 6 module. |
| 82 | Supply and fix white cover plate 8 module. |
| 83 | Supply and fix metal flush box 3 module. |
| 84 | Supply and fix metal flush box 4 module. |
| 85 | Supply and fix metal flush box 6 module. |
| 86 | Supplying and fixing in replacement factory made sheet metal enclosure (double door) shutter type for MCB DB SPN 8 way with 200 Amps rated bus bar, neutral link,earth bar complete. |
| 87 | All as per item No 86 here-in-before but 4 way , Double door. |
| 88 | S&F MCB SP 5 to 32 Amps 240 Volts. ,'C' curve of breaking capacity 10 KA all as specified and directed by Engineer-in-Charge. |
| 89 | S & F MCB SPN 40 to 63 Amps 240 Volts, C' curve of breaking capacity 10 KA all as specified and directed by Engineer-in-Charge. |
| 90 | S & F isolator TPN 63 Amps 240 Volts, C' curve of breaking capacity 10 KA all as specified and directed. |
| 91 | M & L for earthing complete with GI earth plate electrode 600 x 600 x 6.5 mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32x6 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I and including necessary excavation and earth work in any type of soil, removal and refilling of soil and funnel with wire mesh and GI watering pipe 20mm dia, Chamber in PCC 1:3:6, type C1 using 20mm graded stone aggregate and 40mm thick cover in RCC 1:2:4, type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways, handle with 16mm dia round bars and 15mm dia GI pipe upto 7.5m for protection and connected to earthing test point all as specified or indicated including testing on completion. Note:- (i) GI earth lead wire upto 7.5m shall be measured and paid. (ii) PCC chamber shall be provided 50cm away from tthe plinth of building. |
| 92 | S&F LED light fittings 20 watt, 220V, 220 V, AC decorative box type with driver (warm/white), holder, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from celling rose complete. |
| 93 | Supply and fix LED light fitting 1X9W/1X10W bulkhead lumminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 94 | S&F LED luminaire 600mmX600mm, 35/36 watt, 220 V, AC recessed type with high efficiency PMMA diffuser soft glare free light (warm/white) complete with driver, holders & LED lamp suitable for roof ceilling including connecting up with driver three core flexible copper conductor cable of suitable size from celling rose. |
| 95 | Note :- An amount of Rs. 13,344.00 on account of credit schedule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysSep 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender