Housing Urban and Rular Development Government Departments Closing in 13 days TDR #56976139

Tender For Supply, Installation, Testing, Commissioning Of Cctv Surveillance System At Different Locations At Polba, Hooghly Sadar Subdivision Under Mp Lad Scheme.

Issued by Government Departments · 24 Paraganas North, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Aug 2026
13 days left
EMD
67000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Supply, Installation, Testing, Commissioning Of Cctv Surveillance System At Different Locations At Polba, Hooghly Sadar Subdivision Under Mp Lad Scheme.

BOQ

Name of Work:- Supply, Installation, Testing, Commissioning of CCTV Surveillance System at Different Locations at Polba, Hooghly Sadar Subdivision under MP LAD Scheme.
Sl. No. Item Description
1Schedule Item (Part A)Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works(20mm size)
2Non Schedule Item (Part B)Supply & delivery of 3 core 1.5 sq mm armourded copper control cable.(Make- Gloster /Havells/ KEI )
3Cable Laying , Fitting, Fixing, Termination & Installation, commissioning Charges(Considering 1 Wireman for 10 days, 1 Cable jointer for 10 days, 3 Electrical and 3 Electronic Technician for 60 days and 1 software engineer for 10 days.).
4Supply, installation testing and commissioning of the IP bullet camera shall be equipped with a 1/3\\" 4MP progressive scan CMOS imager to capture full HD 1080p (25/30 fps)/2688 × 1520(20fps) images, a 3.6 mm fixed lens, and a waterproof (IP66) IK10 impact-resistant camera housing, As a true day/night solution, the camerashall use Smart IR technology and provide up to 98 ft (30 m) of IR illumination. The camera shall accept PoE (802.3af) or 12 V DC power input. min. illumination:-0.08 lux color @ F2.0 (Color, 1/3s, 30 IRE),0 lux B/W with IR LEDs on @ F2.0) video compression :- H.265 +, noise reduction: 3DNR,backlight compensation :- True WDR 120DB, angle of view :-104°/87° (H), 57°/48° (V),UL listed(Axis/Avigilion/Matrix/Pelco )
5Supply, installation testing and commissioning of 32 channel NVR with 1080p real-time liveview H.265/H.264 MJPEG dual codec decoding Up to 12 MP resolution preview & playback max 320 MBPS incoming bandwidth support 4SATA HDDs up to 32TB, supports fisheye video de-warping in local and web userinterface, supports visual or auditory notifications(a flashing light, bell, or siren)complete with UL certification(Axis/Avigilion/Matrix/Pelco )
68 port PoE switch with 2 SFP ports:Supply, installation testing and commissioning of 8 port PoE switch with 2 SFP ports, having security features like port security supports 64 MACs per port, auto surveillance VLAN, loopback detection automatically disables a port when a loop is detected, cable diagnostics allows administrators to determine cable status, UTP cat. 5, cat. 5e (100 m max.), full/half-duplex for 10/100 MBPS, full-duplex for 1000 MBPS, auto MDI/MDIX adjustment for all twisted-pair ports, switching capacity, 40 GBPS, maximum 64 bytes packet forwarding rate, 14.88 MBPS, ports 1 to 8 compliant with 802.3at. (Make: Zyxel, Allied Telesis, Juniper, Extreme, Huawei)
7Supply, installation testing and commissioning of 24 port PoE switch with 4 SFP ports, having security features like port security supports 64 MACs per port, auto surveillance VLAN, loopback detection automatically disables a port when a loop is detected, cable diagnostics allows administrators to determine cable status, UTP Cat. 5, Cat. 5e (100 m max.), full/half-duplex for 10/100 MBPS, full-duplex for 1000 MBPS, auto MDI/MDIX adjustment for all twisted-pair ports, switching capacity, 56 GBPS, maximum 64 bytes packet forwarding rate, 41.7mbps, Ports 1 to 24 compliant with 802.3 at. (Make: Zyxel, Allied Telesis, Juniper, Extreme, Huawei)
8Supply, installation, testing & commissioning of L.E.D. Display(43”) (4K L.E.D. Display O.S. Webos /Android or equivalent, minimum 50 Hz refresh rate Min. 20 W speaker, Wifi/bluetooth enabled, minimum HDMI & 1USB Port, i/c remote and wall/table top accessories ) (Make: LG/Samsung/Panasonic)
9Supply Installation Testing Commissioning of Surveillance Hard Disk 30TB(Make: WD/Seagate/Hitachi)
10Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, minimum load power factor 0.8,power factor 0.99, having OVCD (over voltage cut-off device), having CVCF (constant voltage constant frequency, bypass parameters configurable, 2 stage charging(constant current/float charge), having temperature compensated charger, Fan speed control, digital signal processor controller, total harmonic distortion (current)- THDi (<10%@50% R Load, Input 1 phase voltage 230v, voltage range 110-300v, Output voltage (220AC/230AC/240AC ± 1%), Total harmonic distortion Voltage (THDv- <3% linear load, <5% nonlinear load, 90 % AC/AC efficiency, Over load capacity(105-110%: 3min, 111- 130%: 30Sec), operating temperature with full load 0-40°C, communication features (RS232, USB com port, Intelligent slot(optional). UPS installation with all required material arrangements as required as per IS specification. 1 KVA Online (Tower Type)UPS with Inbuilt Battery 30 minutes backup Make: APC / DELTA, / Hitachi / Numeric
11Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, minimum load power factor 0.8,power factor 0.99, having OVCD (over voltage cut-off device), having CVCF (constant voltage constant frequency, bypass parameters configurable, 2 stage charging(constant current/float charge), having temperature compensated charger, Fan speed control, digital signal processor controller, total harmonic distortion (current)- THDi (<10%@50% R Load, Input 1 phase voltage 230v, voltage range 110-300v, Output voltage (220AC/230AC/240AC ± 1%), Total harmonic distortion Voltage (THDv- <3% linear load, <5% nonlinear load, 90 % AC/AC efficiency, Over load capacity(105-110%: 3min, 111- 130%: 30Sec), operating temperature with full load 0-40°C, communication features (RS232, USB com port, Intelligent slot(optional). UPS installation with all required material arrangements as required as per IS specification.2 KVA Online UPS with Inbuilt Battery 30 minute backup; Make: APC / DELTA, / Hitachi / Numeric.
126U cabinet with min. Dimensions 366X600X600, wall mounting with 6 point 5 Amp. socket power supply strip, and fan, cable manager, tray as per Site requirement(IP55 Outdoor Wall / Pole Mounted Cross Connect Equipments Rack with sufficient power socket switchboard to accommodate PoE Switch, SMPS, Switch Board, cables, etc) (Make: Valrack / Dynamic / D-link)
1322U cabinet with min. Dimensions 1150X600X600, floor mounting with power supply and fan, tray. Equipment support angle, vertical cable manager, 12 point 5Amp. vertical power strip, earthing continuity kit, castors (1 set of 4 nos.), captive H/W set of 10, fan tray with 4 fan, for computer .(Make: Valrack / Dynamic / D-link)
14Supply, Installation, lying, drawing of 4 Pair Category 6 UTP Cable(ECCS Steel tape Armoured Cable) having 23AWG copper condutor(with FEP insulation, polyester separator, overall shield, flame arrest jacket sheath cover as to standard of ISO/IEC 11801Ed. 2.0, EN 50173-1 and TIA/EIA 568C.) , LSZH Compliant with ETL & TIA/EIA- 568-C.2, Coupling Attenuation should be 45dB min @30‐100 MHz 40‐20 Log (f/100) @ 100‐500 MHz, Should be certified by ETL/UL in existing conduit / wiring system as direction of EIC. (Make: Derwiser / Panduit/ Molex / Commscope)
15FO Transceiver. (Make: Aruba / Extreme / Juniper / Zyxel)
16SITC of 1 Mtr CAT6 SHIELDED TWISTED PAIR PATCH CORDS ETL/UL. (Make: R&M / Legrand / Tyco / Comscope / Molex / Derwiser)
17SITC of 5 Mtr OFC SM Patch Cord with 9/125 μm, OS2 , Duplex Zipcord , SC-LC/LC-LC / SC-SC connecctor , 900μ tight buffer, ISO/IEC 1108:2008, ANSI/TIA/ EIA 568.C.3, ANSI/TIA/EIA-492, TELECORDIA GR-409, ICEA-599. (Make: R&M / Legrand / Tyco / Comscope / Molex / Derwiser)
18SC-LC OFC Patch Cord. (Make: R&M / Legrand / Tyco / Comscope / Molex / Derwiser)
19Edge location Equipment Housing for Switches, Power supply etc. Make : Original OEM accessories ( same as Camera ) or Equivalent or Customize as per site requirements. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56976139
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 29-08-2026
Authority
Authority Name west bengal police housing and infrastructure development corporation
Work Description Tender For Supply, Installation, Testing, Commissioning Of Cctv Surveillance System At Different Locations At Polba, Hooghly Sadar Subdivision Under Mp Lad Scheme.
Basic Detail
Tender No WBPHIDCL/ EE(HQ-I)/NIQ- 4(e)/2026-2027
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 12 Aug 2026
Submission Date 29 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 67000
Exemption Available
Document List
BOQ_5089534.xls
df1e1c9a-9f2f-4aeb-8688-105e575bc379.html
Tendernotice_1 (19).pdf
Tendernotice_2 (3).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_5089534.xls

html

df1e1c9a-9f2f-4aeb-8688-105e575bc379.html

pdf

Tendernotice_1 (19).pdf

pdf

Tendernotice_2 (3).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders