Tender for Repair And Renovation For Upgradation Work Of 12 (Twelve) Nos. Flats (Flat No.C/1/1, C/1/2, C/1/3, C/1/4, C/1/5, C/1/6, C/1/7, C/1/8, C/1/9, C/1/10, C/1/11, C/1/12) Of C-1 Block And 2 (Two) Nos. Flats (Flat No. B/1/1 And B/1/7) Of B-1 Block At Sjda Housing Complex, Rajbari Para Rhe, Of Circuit Bench, Jalpaiguri Under Electrical Sub-Division No-Iii, H.D.
BOQ
| Sl. No. | Item Description |
| 1 | SUB-HEAD 01--Distribution WiringDistribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) for ECC in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall for horizontal & vertical runs and in suitable size PVC casing-capping (Precision make) for ceiling portion only, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Legrand: Myrius/Arterior or equivalent model as per choice of EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment flushed in wall incl. mending good damages to original finish [only PVC casing-capping on ceiling and remaining portion concealed] Average run 6 mtr |
| 2 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC on board |
| 3 | Sub Head 02 - BDB,PDB,VTPN ETCSupplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment .2 way |
| 4 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.2+12 Way (Make: Legrand/Seimens/Schneider/ABB/L&T) as per direction of EIC. ] |
| 5 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS (Make: Legrand/Seimens/Schneider/ABB/L&T) as per direction of EIC. ]. 40 A DP |
| 6 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make: Legrand/Seimens/Schneider/ABB/L&T) as per direction of EIC. ] 40 A DP |
| 7 | 6-32 A SP |
| 8 | Sub Head 03 - Wires & CablesSupplying and Drawing 1.1 KV single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and makingnecy. connection as required 3x1.5 sqmm ECC |
| 9 | 2x2.5 sqmm+1x 1.5 sqmm ECC |
| 10 | 2x4 sqmm+1x 2.5 sqmm ECC |
| 11 | 2x6 sqmm+1x 4 sqmm ECC) |
| 12 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. 19 mm dia 3 mm thick polythene pipe without earth continuity wire |
| 13 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.1.5 sqmm |
| 14 | 2.5 sqmm |
| 15 | 4 sqmm |
| 16 | 6 sqmm |
| 17 | Sub Head 04 - Switch & SocketsSupplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. (b) 6 module |
| 18 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 2 module |
| 19 | 4 module |
| 20 | Supply & Fixing 240 V 6 A Modular type switch on existing GI Modular type switch board having top cover plate and making necessary connections as required .(Make: Legrand/Seimens/Schneider/ABB/L&T) as approved by EIC (For 1x6 A separate plug) |
| 21 | Supply & Fixing 240 V 6 A Modular type switch on existing GI Modular type switch board having top cover plate and making necessary connections as required .(Make: Legrand/Seimens/Schneider/ABB/L&T) as approved by EIC (For 1x6 A separate plug) |
| 22 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make: Legrand/Seimens/Schneider/ABB/L&T) as approved by EIC |
| 23 | Supply & Fixing 240 V 16 A Modular type switch on GI Modular type switch board having top cover plate and making necessary connections as required. (Make:- Legrand/Cabtree) |
| 24 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket, without plug top and switch, on existing GI Modular type switch board with topcover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make: Legrand/Seimens/Schneider/ABB/L&T) as approved by EIC |
| 25 | Supply & Fixing 240 V, 25A Modular starter (Brand approved by EIC) on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make: Legrand/Seimens/Schneider/ABB/L&T) as approved by EIC |
| 26 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc (Make: Legrand/Seimens/Schneider/ABB/L&T) as approved by EIC |
| 27 | Supply & Fixing 240 V, 25A Modular starter (Brand approved by EIC) on existing GI Modular type switch board with top cover plate and making necy. Connections. |
| 28 | Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Computer Board) |
| 29 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 30 | Supplying & Fixing 240 V AC/DC superior type Ding-DongCall Bell (Anchor) on HW board incl. S&F HW board. Sub Head 05 - Supply & Fixing of Fittings . |
| 31 | Sub Head 05 - Supply & Fixing of FittingsSupply & Fixing of 1200 mm sweep; 50W; 320 rpm; 225 cmm ceiling Fan; (Make:-Orient Summer Cool or equivalent model of Crompton/Usha as per approval of EIC/Authority) complete with all accessories, down rod etc. & without regulator. |
| 32 | Supply and Fixing Heavy duty exhaust fan 80 Watt, 230 mm (9'') sweep 1370 RPM (Make EPC or equivalent model of USHA/Crompton/Orient) as per choice of E.I.C |
| 33 | Supply and Fixing of 4ft single Commercial LED tube incl. Supply of 1 no. 20W LED Tube [Make- Phillips/Crompton/wipro as approved by E.I.C] |
| 34 | Supply and fixing 9 W LED bulb (make- Phillips/Crompton/wipro as approved by E.I.C) on existing batten holder |
| 35 | S&F 7.5 W LED 450lm Decorative type mirror light (make- Phillips/Crompton/wipro as approved by E.I.C) |
| 36 | Fixing of 3 Module 2W, 3000K LED Foot Light fittings. incl. S/F 3 Module MS flush box in wall as per approval of EIC/Authority. |
| 37 | Supply & fixing of Blank Plate for modular box. |
| 38 | Add. G.S.T.@ 18% (on Total from item no 1 to 37) to be calculated by bidder |
| 39 | Add. LWC.@ 1% to be calculated (on total from item no 1 to 37 + GST@18%) by bidder Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender