Tender For Running And Maintenance Of 10 No. Tube-Well In Nurpur Area In Tehsil Nurpur Distt. Kangra (H.P.) (Sub-Head:- Replacement Of Submersible Pumping Machinery Without Allied Accessories)
Tender Value
4.50 Lakhs
Estimated cost
Bid Submission
22 Aug 2026
0 days left
EMD
9000
Bank guarantee accepted
Document Fee
350
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kangra → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Running And Maintenance Of 10 No. Tube-Well In Nurpur Area In Tehsil Nurpur Distt. Kangra (H.P.) (Sub-Head:- Replacement Of Submersible Pumping Machinery Without Allied Accessories)
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Submersible Pumping Set of Calama/KSB/Crompton/SU/Johnston /BS/Sabar make conforming to BIS-8034-1976 (Latest) suitable for clear water fitted with bronze Impellers or suitable alloys directly coupled to squirrell cage electric Induction Motor of same make as that of Pump conforming to BIS:9238-1979(Latest with uptodate ammendments) and totally water proof for Submersible duty,isolated from the pump by intermediate casing with double Mechanical seal in oil chamber,grease packed lubricated bearings and provided with stainless steel thrust bearing plate to withstand non-vertical loads with minimum wear and tear. It should also be fitted with a device to take-up expansion of water with the heating of motor including water level guard,erection clamps,cable clips and depth gauge etc. The Pump shall be sui-table for operation on data given below:- |
| 2 | Location of site :-The site is located at a distance of 10 Kms.from Nurpur Road Railway Station. |
| 3 | The altitude of place in which :-Altitude of place is 500 Metres above Mean Sea Level the Motor is intended to work |
| 4 | Type of current :-A.C.Three phase supply with frequency 50 cycles per second. |
| 5 | Rated Voltage :-415 Vvolts (+/-) 10% |
| 6 | Charactristics of water. (a) Ambient Temperature dig. =20 dig. C (b) Turbidity NTU =113NTU ( c) Hardness260Mg/Ltrs(as CaCO3) =540Mg/Ltr (d) PH =6.5 to 8.5(e) TDS =540PPM (f) Other |
| 7 | Depth of T/Well Assembly :- 57.92 Metres.B.G.L. |
| 8 | L.W.L.in P/ Well :- 376.08 Metres |
| 9 | Maximum draw down level :- 376.08 Metres |
| 10 | Centre line level of Pump :- 376.08 Metres |
| 11 | Discharge level of highest point :- 498.50 1.00 Metres |
| 12 | Nos.of Pumps required :-1 No.Pump. |
| 13 | Capacity :- 15.17 L.P.S. |
| 14 | Total head in Metres :-135.76Metres |
| 15 | Length of Rising Main :- 900 Metres |
| 16 | Dia of Rising Main :-125 mm dia G.I.pIpe. |
| 17 | No.of working hours per day :-20.00 Hours. |
| 18 | Limits of pump operation :- ( - ) 15% ( + ) 10% of total head. |
| 19 | H.P.of Motor/Drive unit :-Required 50 H.P.of Pump at ( + ) 10% and ( - ) 15% of total head. BHP.with following margins/multiplying factor at duty point,whichever is higher. a).Upto 2 H.P. =1.5 (d) 10 to 20 H.P. =1.2 b).2 to 5 H.P. =1.4 (e) 20 to 100 H.P. =1.15 c) 5 to 10 H.P. =1.3 (f) Above 100 H.P. =1.10 |
| 20 | Test Run :-16 Hours continueously for 7 days. |
| 21 | Providing and laying suitable size copper PVC.insulated armoured power 3.5 core cable of size mm² conforming to BIS-1554-Part-I -1988 or latest with uptodate ammendments Siemen/Gloster/ICC make from Meter of HPSEB. to MCB/OCB & from OCB to Busbar Switch & Starter(One cable carrying all three phases) including all other elecrc equipments/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipers or trenches size and make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.auithority shall have to be replaced by the tenderer free of cost. |
| 22 | Suppply side________ mm Square (The size of cable shall be specified by the tenderer). |
| 23 | Providing and laying PVC.jointless flat water proof copper cable mm² as per BIS-694-1990(Latest with uptodate ammend-ments) suitable for the pump set offered from OCB to Motor, Motor to Starter including all other electric equipment such as;thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipes or trenches under floor. The type and make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.authoirity,it shall have to be replaced by the tenderer free of cost. |
| 24 | Motor side________ mm Square (The size of cable shall be specified by the tenderer). |
| 25 | Erection of all equipments including cost of tees,bends,tapers and any other fittings required as per site conditions and as per directions of the Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 22, 2026