Tender For Special Repair Of Building No P-121 (Gun Garage) Of Ad Regt At Sectore C Makarpura Under Ge (A) Baroda.
Tender Overview
Project Description
Tender For Special Repair Of Building No P-121 (Gun Garage) Of Ad Regt At Sectore C Makarpura Under Ge (A) Baroda.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 31-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 07-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings. |
| 2 | M&L Cement concrete of type B1 1:2:4 in 20mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates,and the like including weathering, slightly rounded chamfered angles and throating, complete with using necessary form work all as specified and directed. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an approved by Engr-in-chrg colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, fixed with self tapping screws as per manufactures instruction complete all as specified and directed.Note:-Colour of sheet shall be decided by the user & as directed by the GE. |
| 4 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of anycolour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifiedNote:-Colour of sheet shall be decided by the user & as directed by the GE. |
| 5 | Dismantling of structural steel work including doors, gates but excluding frame truss etc complete all as specified and direted by Engr-in-charge. |
| 6 | M&L mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or othercovering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel eeting or other covering,running rails and guides) and hanging; also astening and fixing complete |
| 7 | M&L for mild steel work as in bands traps, supports or stays for rainwater, ventilating pipes,including bolts, if required:hooks (stay), heavy, for largegates; hook and pintle hinges,rollers,running rails large hasps and staples; chains;hand made sliding bolts; clamps;hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps,and such small items plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete as specified and directed. |
| 8 | M&L Mild steel 1.25mm, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required |
| 9 | M&L for paint on new Surfaces of any description, over 10cm in width or girth,not otherwise described priming with one coat of coat of red oxide and apply two coats of synthetic enamel paint complete all as specified and directed. |
| 10 | Demolition of cement concrete as in ground floors/path and pavings n exc 15 cm thickness below or above GL all as specified and directed. |
| 11 | M&L For M-25 grade concrete (Design Mix) as in flooring 100 mm thick using 20mm aggregate incl mixing metallic floor hardener (as per design of Mix) and expansion joints, machine-trowelled vacuum dewatered concrete (Trimix) flooring including surface preparation, laying, compaction, vacuum dewatering, power troweling, curing, and finishing complete including necesary form work and as per specifications and instructions of Engineer-in-charge.Note:-Metallic floor hardener shall be measured and paid separately as supply only under respective item of this schedule. |
| 12 | Supply only metallic floor hardener (Nito floor hard top) complete all as specified and directed by the Engr-in-Charge. |
| 13 | M&L 20mm thick perforated filler for expansion joint, complete all as specified and directed. |
| 14 | Supply and application of Nito seal 280 for filling up joint all as specified and directed. |
| 15 | Providing and laying an epoxy based colour flooring painting of minimum thickness 3mm including surface preparation, primer coat, base coat, colour coat and finishing top coat with approved shade/pigment, complete all as per manufacture's specifications and direction of Engr-in-Charge. |
| 16 | M&L Taking down cement plaster on brick or stone walls etc at any height including raking out joints, hacking for key. scrubbing down with water etc complete as specified and directed. |
| 17 | M&L for 10 mm thick rendering in CM 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement at any height including wire mesh nettting where ever required complete all as specified and directed. (Note: Wire mesh netting shall be measured & paid separately as S & F under respective item of this schedule) |
| 18 | M & L for preparing new plastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over and including a coat of 2mm average thickness birla/ equivalent wall care putty and one coat of primer all as specified and as directed. |
| 19 | Complete removal of existing surface for preparing old plastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over and including a coat of 2mm average thickness birla/ equivalent wall care putty and one coat of primer all as specified and as directed. |
| 20 | M& L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces including removing existing fineshes complete. |
| 21 | Demolition of cement concrete of any description and in any position not otherwise specifically provided. |
| 22 | M & L for 75 mm thick PCC 1:3:6 mix type C2 using 40mm graded stone aggregate as in paving finishing cone surface (plinth protection) even and smooth without using extra cement. |
| 23 | Demolition brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc, |
| 24 | M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6, compelte all as specified and directed. |
| 25 | Taking down copper/aluminium point wiring (light fan, socket or power) complete including fittings such as switch, sockets, c/rose, lamp holders, tube light fittings, sketch fitting , wooden boards, bell push, call bell, MCBs & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall floor etc. |
| 26 | Taking down main switch, DB/change over/VTPN, MCCB AC box of any capacity. |
| 27 | M&L for taking down carefully sub main wiring including batten any type of conduit by unscrewing from floor,wall,ceiling and making good surfaces to match with original status for all types of sub main wiring. |
| 28 | M & L for concealed point wiring complete with multistranded copper conductor (FRLS)1.5 Sqmm size PVC insulated unsheathed cable 1100 volt grade, conforming IS 694 & color code in conduit system of wiring, drawn in including PVC conduit not less than 20 mm dia concealed duly fixed with U-Clips, including cutting chases, finising of slote by means of cement mortor making good to the existing surface of the wall & touching with the existing colour of wall with three coats and making good disturbed surface complete, sunk in pressed Modular Metal flush box of required size not less than 2 mm thick GI Plate factory made with modular cover plate, screw with all accessories including single core multistranded copper conductor 1.5 sqmm size solid PVC insulated unsheathed cable (FRLS) as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified. |
| 29 | For one light, fan point controlled by one switch. |
| 30 | For one 5 Amp independent socket point controlled by one switch. |
| 31 | All as per item No 28 here in before but for power point wiring using with 2.5 sqmm PVC-FR LS insulated ,sheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,sheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by engir in charge. |
| 32 | S&F Modular switch 1 way 6A, 1module. |
| 33 | S&F Modular Socket, 6A - 2/3 pin combined 2module. |
| 34 | S&F Modular switch 1 way 16A, 1module. |
| 35 | S&F Modular Socket, 16A - 3/5 pin combined 2module. |
| 36 | S&F Modular Fan step regulator, 120W - 2 module. |
| 37 | S & F ceiling rose surface polycarbonate body three terminal. |
| 38 | M&L concealed Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 20 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor.NOTE : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length. |
| 39 | S & F of ceiling fan operated with blades, anti suicide rod from existing roof / trus to fall ceiling, electronic regulator operated and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed.Note : 1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. |
| 40 | S & F of LED light fitting 20 Watts (4 Feet), 220 Volts AC, Aluminium extrusion , input 140-270 Volts AC, CCT 6000K, luminus efficiancy 100 lumens/watt, surge protection upto 4KV volage protection upto 440V, AC, PF >0.9 and including LED light fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 41 | S&F sheet metal enclosure TPN DB's double door 4 Ways, IP-43 240 V with 200 Amps rated bus bar. Note :- Cutting and chasing in stone/Brick masonary and making good to disturbed surfaces will be including in item rate . |
| 42 | S&F sheet metal enclosure for DB double door SPN 8 Ways, IP-43 240 V with 200 Amps rated bus bar. Note :- Cutting and chasing in stone/Brick masonary and making good to disturbed surfaces will be including in item rate . |
| 43 | S&F testing and commissioning of MCB TPN 415 volt 40 Amp 16 KA capacity having C-curve characteristics connected with suitable lugs. |
| 44 | S&F testing and commissioning of MCB SPN 240 volt 16 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs . |
| 45 | S&F testing and commissioning of MCB SP 6 Amp to 40 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs. All as specified and directed by Engr in charge. |
| 46 | S & F of LED bldg security light fitting 35 Watt input voltage 140-270V AC outdoor type with high robust die cast body aluminium housing CCT 6500K lumeinous efficincy > 120 lumens/watts CRI > 70, PF >0.95 protection class IEC safety class-I and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including bracket made out of GI pipe light grade 32mm bore not less than 1.20m long bent to shape required fixed to pole with suitable size 2 Nos clamps made out of 25X3mm flat iron with nut, bolts and washers complete including old U/S taking down complete all as specified and directed. Note :- The warranty on light should be of minnimum 3 Years . |
| 47 | S & F of exhaust fan made of sturdy engineering Steel body complete with louvers shutter & mosquito net, voltage 230V, 50Hz, RPM 1200, copper winding of sweep 450 mm including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including make hole in stone/brick wall grouting & making good in all aspects and taking down existing UNSV exhaust fan complete all as specified and directed.Note : 1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. Please Enable Macros to View BoQ information |
| 48 | S & F of exhaust fan made of sturdy engineering Steel body complete with louvers shutter & mosquito net, voltage 230V, 50Hz, RPM 1200, copper winding of sweep 450 mm including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including make hole in stone/brick wall grouting & making good in all aspects and taking down existing UNSV exhaust fan complete all as specified and directed.Note : 1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender