Tender For Repair/ Maintenance Of Dg Set, Amf Panel And Other Connected Works At Af Stn Awantipur
Tender Value
40 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
9 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
awantipora → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Repair/ Maintenance Of Dg Set, Amf Panel And Other Connected Works At Af Stn Awantipur
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (AF), 8FBSU,AF Name of Work: REPAIR/MAINT OF DG SET, AMF PANEL AND OTHER CONNECTED WORKS AT AF STN AWANTIPUR Contract No: GE (AF) AWA-29/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. DESCRIPTION OF ITEMS Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Material and labour for carrying out ‘B’ check for various capacity of following DG sets by replacing the following accessories of DG set, complete all as specified and directed by Engr-in-Charge.(a) Oil filter.(b) Air filter.(c) Fuel filter.(d) By pass filter.(e) Engine oil .(f) coolant.Note :- (i) 'B' checks shall be carried out by experienced fellow who is well aware of DG set work.(ii) Engine oil & coolant shall be measured and paid separately.(iii) Labour & transportation shall be arranged by contractor and quoted rate deemed to be inclusive in the unit rate. |
| 3 | Description all as per item No.1.00 here-in-before but for 320 to 1000 KVA DG set, complete all as specified and directed by Engr-in-Charge. |
| 4 | Description all as per item No.1.00 here-in-before but for 160 to 250 KVA DG set, complete all as specified and directed by Engr-in-Charge. |
| 5 | Description all as per item No.1.00 here-in-before but for 100 to 125 KVA DG set, complete all as specified and directed by Engr-in-Charge. |
| 6 | Description all as per item No.1.00 here-in-before but for 30 to 82.5 KVA DG set, complete all as specified and directed by Engr-in-Charge. |
| 7 | Description all as per item No.1.00 here-in-before but for 10 to 30 KVA DG set, complete all as specified and directed by Engr-in-Charge. |
| 8 | Taking out the existing battery of DG set and repair/replacement of unserviceable/faulty lead acid Battery of capacity 150 AH, 12V including connecting to DG set, complete all as specified and directed by Engr-in-Charge. |
| 9 | Description all as per item No. 2.00 here-in-before but of 180 AH, 12V including connecting to DG set, complete all as specified and directed by Engr-in-Charge. |
| 10 | Renewal/ repairs/supply of unserviceable automatic voltage regulator (AVR) 10 to 82.5 KVA DG set including all spares, testing, complete all as specified and directed by Engr-in-Charge. |
| 11 | Renewal/ repairs/supply of unserviceable automatic voltage regulator (AVR) 100 to 250 KVA DG set including all spares, testing, complete all as specified and directed by Engr-in-Charge. |
| 12 | Renewal/ repairs/supply of unserviceable automatic voltage regulator (AVR) 320 to 400 KVA DG set including all spares, testing, complete all as specified and directed by Engr-in-Charge. |
| 13 | Dismantling of exhaust pipe of the DG set 10 KVA to 400 KVA capacity by unscrew nuts and bolts and taking down the pipe with muffler, cleaning the silencer, welding works if required, painting and fixing the same in its original position, complete all as specified and directed by Engr-in-Charge . |
| 14 | Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacities DG sets and taking down the radiator assembly by unscrewing all mechanical/ electrical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly, cleaning thoroughly the chocked pipe of the radiator by using chemical detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers and Anti vibrating mounting(AVM) pads as required as per OEM recommendation etc., for the DG set of capacity 10 KVA and up to 400 KVA complete all as specified and directed by Engr-in-Charge. |
| 15 | Renewal /supply of battery cable leads of copper conductor and with brass lugs terminal, for the 12V, 150/180 /200 AH batteries to self starter as that of existing size and length, complete all as specified and directed by Engr-in-Charge. |
| 16 | Taking down the unserviceable belt from the DG set Supply, test and commissioning of belts suitable for fan, alternator, dynamo, radiator of the DG Set of following capacity, complete all as specified and directed by Engr-in-Charge :- (a) 10 KVA to 400 KVA. |
| 17 | Engine oil 15W/40 for toping up upto the required level and service, complete all as specified and directed by Engr-in-Charge. |
| 18 | Replacement /supply of Line Voltage Monitors (LVMS) of existing make of DG set of 100 KVA to 400 KVA capacity listed parameters including testing, complete all as specified and directed by Engr-in-Charge.Make :- OEM recommended |
| 19 | Replacement /supply of Line Voltage Monitors (LVMS) of existing make of DG set of up to 100 KVA capacity listed parameters including testing, complete all as specified and directed by Engr-in-Charge. |
| 20 | Drain out the fuel from the fuel tank of DG set of any size/capacity and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements, complete all as specified and directed by Engr-in-Charge. |
| 21 | Drain out the fuel from the fuel tank of capacity 24 KL Diesel tank and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank.incl two coat of synthetic enamel paint, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements, complete all as specified and directed by Engr-in-Charge. |
| 22 | Removing the defective charging dynamo/alternator of capacity 12/24 Volt DC any make, model, of capacity 10 to 125 KVA and opening it by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling, lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable for same existing size/gauge & reconnecting the same, refixing back in original position including making all necessary electrical/mechanical connections, testing and commissioning, complete all as specified and directed by Engr-in-Charge. |
| 23 | Removing the defective charging dynamo/alternator of capacity 12/24 Volt DC any make, model, of capacity 160 to 400 KVA and opening it by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling, lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable for same existing size/gauge & reconnecting the same, refixing back in original position including making all necessary electrical/mechanical connections, testing and commissioning, complete all as specified and directed by Engr-in-Charge. |
| 24 | Inhibitor corrosion (coolant additive concentrate) required for top up, complete all as specified and directed by Engr-in-Charge. |
| 25 | Supply and topping up of acid mixture suitable for lead acid batteries of 12 volts, complete all as specified and directed by Engr-in-Charge. |
| 26 | Supply and topping up of distilled water suitable for lead acid batteries of 12 volts, complete all as specified directed by Engr-in-Charge. |
| 27 | Supply and fix Battery brass terminal and jelly, complete all as specified and directed by Engr-in-Charge. |
| 28 | Calibration of the unserviceable Fuel injection Pump assy, Test & commissioning of Fuel injection pump assy after calibration inclusive of injector system for following DG Set, complete all as specified and directed by Engr-in-Charge :-Note :- Calibration shall be performed before erection of FIP.(a) 10 KVA to 400 KVA |
| 29 | Repair and replacement of the unserviceable Fuel injection pump assy install ,Test & commissioning of Fuel injection pump assy inclusive of injector system for following DG set, complete all as specified and directed by Engr-in-Charge :-Note :- Calibration shall be performed before erection of FIP.(a) 10 KVA to 160 KVA |
| 30 | (b) 200 KVA to 400 KVA |
| 31 | Overhauling of injector nozzles of capacity 320 KVA to 400 KVA test & commissioning of injector nozzles inclusive of injector system, complete all as specified and directed by Engr-in-Charge. |
| 32 | Overhauling of injector nozzles of capacity 125 KVA to 250 KVA test & commissioning of injector nozzles inclusive of injector system, complete all as specified and directed by Engr-in-Charge. |
| 33 | Overhauling of injector nozzles of capacity 10 KVA to 100 KVA test & commissioning of injector nozzles inclusive of injector system, complete all as specified and directed by Engr-in-Charge. |
| 34 | Repair to Self starter Motor, 12/24 volts, suitable for existing DG set above 10 KVA to 125 KVA capacity including making all necessary electrical/mechanical connection as per recommendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position, complete all as specified and directed by Engr-in-Charge.Make :- Approved by OEM of DG set |
| 35 | Repair to Self starter Motor, 12/24 volts, suitable for existing DG set above 160 KVA to 400 KVA capacity including making all necessary electrical/mechanical connection as per recommendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position, complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F in replacement of self starter 12 volts DC suitable for 10 to 125 KVA DG set, complete including dismantling of existing and fixing the new fixing in position, making proper alignment complete all as specified and directed.Make :- Approved by OEM of DG set. |
| 37 | S&F in replacement of self starter 24 volts DC suitable for 160 to 400 KVA DG set, Make: Kirloskar complete including dismantling of existing and fixing the new fixing in position, making proper alignment complete all as specified and directed.Make :- Approved by OEM of DG set. |
| 38 | S & F Diesel benjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity up to 125 KVA including taking down old unserviceable one, complete all as specified and directed by Engr-in-Charge. |
| 39 | S & F Diesel benjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity above 125 KVA up to 400 KVA including taking down old unserviceable one, complete all as specified and directed by Engr-in-Charge. |
| 40 | Repairs to Alternator of following DG Sets, transporting the same to the OEM authorised service center/work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the alternator with copper wire of same gauge turns and weight, checking of commentator, brushes complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete and testing ,complete all as specified and directed by Engr-in-Charge :-Note: Copper winding material will be measured and paid separately under relevant Item(a) DG set Upto 400 KVA capacity. |
| 41 | Supply only High conductivity copper conductor winding material including necessary insulation material required, complete all as specified and directed by Engr-in-Charge. |
| 42 | Overhauling of Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from for the following DG sets, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the same after repair to its original position and reconnecting the same including testing, complete all as specified and directed by Engr-in-Charge:- |
| 43 | (a) DG Sets of capacity 10 KVA to 125 KVA. |
| 44 | (b) DG Sets of capacity 125 KVA to 400 KVA. |
| 45 | Supply and fix new Turbo Charger Assembly(In replacement) duly disconnecting the mechanical and electrical connections from for the following DG sets, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the new turbo charger assembly to its original position and reconnecting the same including testing, complete all as specified and directed by Engr-in-Charge:- |
| 46 | (a) DG Sets of capacity 10 KVA to 125 KVA. |
| 47 | (b) DG Sets of capacity 125 KVA to 400 KVA. |
| 48 | Dismantling & disconnecting all connection of upper and lower engine, cylinder heads,lines,thrust valve, valve seal inlet and exhaust, main bearing set, inlet valve and exhaust valve, head gasket,CR bearing, hose set, ring set, valve seal, liner O ring, oil seal set,O rings kit, Crank shaft ,Connecting roads, Push roads, Value Guides, Valves seats ,piston assy and all connecting items like ring ,washer, gasket etc from diesel engine and sent to OEM authorised Service center for calibration and repairs by replacing the all above said spares such as cylinder heads,lines,thrust valve, valve seat inlet and exhaust, main bearing set, inlet valve and exhaust valve, head gasket,CR bearing, hose set, ring set, valve seal, liner O ring, oil seal set,O rings kit, Crank shaft ,Connecting roads, Push roads, Value Guides, Valves seats ,piston assy and all connecting items like ring ,washer, gasket etc and re-assembling to its original position with necessary fittings and O rings for the following capacities including testing, complete all as specified and directed by Engr-in-Charge.Note : Any minor or major spares other than above is included in the quoted rates. |
| 49 | (a) DG Sets of capacity 10 to 125 KVA. |
| 50 | (b) DG Sets of capacity 125 to 250 KVA. |
| 51 | M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25x4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing complete all as specified. |
| 52 | M&L for plate earthing complete with copper plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including copper earthing strip 20x3 mm bracing/bolted (with copper nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus including testing complete all as specified. |
| 53 | Supply and fix tappet cover for DG set of 10 KVA to 125 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engr-in-Charge. |
| 54 | Supply and fix tappet cover for DG set of 160 KVA to 400 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engr-in-Charge. |
| 55 | Replacement of controller display suitable to DG set controls/commands of 320 KVA to 400 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engr-in-Charge. |
| 56 | Replacement of microprocessor based control unit suitable to DG set controls/commands of up to 160 KVA 250 KVA capacity with all listed parameters as per recommendation including testing, complete all as specified and directed by Engr-in-Charge. |
| 57 | Replacement of microprocessor based control unit suitable to DG set controls/commands of 10 to 125 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engr-in-Charge. |
| 58 | Replacement of microprocessor based Display unit(HMI) suitable to DG set controls/commands of 10 KVA to 400 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engr-in-Charge. |
| 59 | Replacement of Actuator suitable to DG set controls/commands of 10 KVA to 160 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engr-in-Charge. |
| 60 | Replacement of actuator suitable to DG set controls/commands of 200 KVA to 400 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engr-in-Charge. |
| 61 | Supply and mounting AVM (anti vibration) pads for Engine, radiator and alternator of DG set of any capacity including labour charges for proper mounting and all necessary misc accessories, complete all as specified and directed by Engr-in-Charge. |
| 62 | Supply and fix Asbestos rope suitable for existing DG set including, complete all as specified and directed by Engr-in-Charge. |
| 63 | Supply and fixing battery charger 230 V AC input and output 24 V/12 V 10 amps charging rating IMPS type with fully auto control in charging and floating with boost system, complete all as specified and directed by Engr-in-Charge. |
| 64 | Supply and fix fuel tank lock and key suitable for existing DG set including removing old un serviceable one, complete all as specified and directed by Engr-in-Charge. |
| 65 | Supply and fix Door lock and key with door rod assy in side the door suitable for existing DG set including removing old un serviceable one, complete all as specified and directed by Engr-in-Charge. |
| 66 | Supply and fix Door hinges suitable for existing DG set including removing old unserviceable one, complete all as specified and directed by Engr-in-Charge. |
| 67 | S&F in repair/replacement of on Automatic Transfer switch100 Amps capacity, suitable for 3 phase, 4 pole, 415 Volts, fixing in existing panels including necessary lugs, glands, nuts, bolts including taking down old unserviceable one, complete all as specified and directed by Engr-in-Charge. |
| 68 | Supply and fix Contactor Assembly & PLCs with under + over voltage relay for existing DG set AMF panel of capacity up to 160 KVA including removing old un serviceable one, complete all as specified and directed by Engr-in-Charge. |
| 69 | Supply and fix Contactor Assembly & PLCs with under+ over voltage relay for existing DG set AMF panel of capacity 200 to 400 KVA including removing old un serviceable one, complete all as specified and directed by Engr-in-Charge. |
| 70 | Servicing to AMF panel of capacity 10 KVA to 125 KVA from the Circuit system by checking the following parameters for proper functioning, complete all as specified and directed by Engr-in-Charge :- a) Checking / fault diagnosis of Isolator ,Battery charger, Auto/Manual selector switch & Current Transformer. b) Checking the Electronic circuit boards with phase indication lamp 220 V. c) Checking the functionality & calibration of Power Relays (Cranking Relays). d) Checking the Mechanism of isolator module and vcb module Note:- Rates of all spares and Parts including repair and replace are included in quoted rate. |
| 71 | Servicing to AMF panel of capacity 160 KVA to 400 KVA from the Circuit system by checking the following parameters for proper functioning, complete all as specified and directed by Engr-in-Charge :- a) Checking / fault diagnosis of Isolator ,Battery charger, Auto/Manual selector switch & Current Transformer. b) Checking the Electronic circuit boards with phase indication lamp 220 V. c) Checking the functionality & calibration of Power Relays (Cranking Relays). d) Checking the Mechanism of isolator module and vcb module Note :- Rates of all spares and Parts including repair and replace are included in quoted rate. |
| 72 | Supply and fix Copper lugs 120 sqmm to 150 sqmm suitable for 1100 Volt copper cable suitable for existing DG set including removing old unserviceable one, complete all as specified and directed by Engr-in-Charge. |
| 73 | Taking down the unserviceable primary diesel feeder pump assy from DG set Supply, install, Test & commissioning of primary diesel feeder pump assy inclusive of all spare and parts system for following DG set, complete all as specified and directed by Engr-in-Charge:-Note:- Calibration shall be performed before erection of pump.(a) 10 KVA to 160 KVA |
| 74 | Taking down the unserviceable primary diesel feeder pump assy from DG set Supply, install, Test & commissioning of primary diesel feeder pump assy inclusive of all spare and parts system for following DG set, complete all as specified and directed by Engr-in-Charge :-Note:- Calibration shall be performed before erection of pump.(a) 160 KVA to 400 KVA |
| 75 | Complaint/Inspection & visit the power house/sub station for checking the fault occur in DG set of any capacity ,Rectify the fault at own arrangement and report to JE /Engr in charge after rectifying the fault and proper testing and commissioning of DG. All spare and parts will be paid and measured separately at site, complete all as specified and directed by Engr-in-Charge. |
| 76 | Supply and fix Hour meter operating on 240 V suitable for existing DG set including removing old un serviceable one, complete all as specified and directed by Engr-in-Charge. |
| 77 | Supply and fix garage mats for floor absorb liquids oil drips pan with waterproof Rubber backing layer for protection of floors. Size of mat 2 mtr x 4 mtr for DG set at substation, complete all as specified and directed by Engr-in-Charge. |
| 78 | Supply and replacement of digital ampere meter of suitable range as per existing size all as specified and directed. |
| 79 | Supply and replacement of digital voltmeter 0-500 volts as per existing size all as specified and directed. |
| 80 | Supply and replacement of digital frequency meter as per existing size all as specified and directed. |
| 81 | Supply and replacement of selector switch as per existing size all as specified and directed. |
| 82 | Supply and fixing in replacement MCCB 125 Amp, 4 Pole 36 KA all as specified and directed. |
| 83 | Supply and fixing MCCB in replacement of 100 Amps, 3 pole, 415 Volts, 50 HZ, rupturing capacity 16 kA, connection with proper size of thimbles complete including taking out defective/ unserviceable MCCB all as specified and directed. |
| 84 | Supply and fixing in replacement engine start relay 12 Volt DC suitable for AMF panels, complete all as specified as directed by Engr-in-Charge |
| 85 | M&L for replacement of L&T MCX 12, 63A 4 pole power contactor Cat No. CS97014 for maping with AMF panel of DG Set functional, all as specified and directed. |
| 86 | M&L for replacement of L&T MCX 22,100 A 4 pole power contactor Cat No. CS97017 for maping with AMF panel of DG Set functional, all as specified and directed. |
| 87 | M&L for replacement of L&T MCX 33 2NO+2 NC, 200A 4 pole power contactor Cat No. CS97021 for maping with AMF panel of DG set functional, all as specified and directed. |
| 88 | Supply and fixing in replacement MCCB 63A, 4 Pole 36 kA all as specified and directed. |
| 89 | Supply and fixing in Replacement RPM metre with cable (0-3000 RPM), complete all as specified and directed by Engineer-in-Charge. |
| 90 | M& L in replacement of microprocessor based speed control units including supply, installation, commissioning and testing of this units at existing site and offer precise (+/- 0.25%) speed control with fast response to transient load changes in isochronous, Droop & Variable Operation, Starting Fuel & Speed Ramping Adjustment, Soft Coupling, Lead Circuit Auxiliary Input & 10V Supply Over speed Contact for the capacity of DG sets 25 to 100 KVA complete all as specified and directed Engineer-in-Charge, all as specified and directed by Engr-in-charge. Note- The item should be made Governors America Cop. |
| 91 | Supply and fixing in replacement of Card, Control for DG Set of capacity 200 KVA, complete all as specified and directed . |
| 92 | M&L for writing of SM No./MES No. on DG Set with durable and weather-resistant paint recommended 2-Pack paint or its equivalent all as specified and directed by Engineer-in-charge. |
| 93 | Supply and Laying Synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS-15652-2006 (Superseding IS-5424) suitable for electrical shock safety of size 2m x1m all as specified and directed by Engineer-in-Charge. |
| 94 | NOTE-Contractor should visit the site before quoting the tender. |
| 95 | Note:- An amount of Rs. 71,920.00 on account of credit schedule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender