BOQ
| Sl. No. | Item Description |
| 1 | Taking down frame with shutters (without taking off shutters from frame) exc 1.5 sqm but n.exc 4 sqm each, complete all as specified and directed. |
| 2 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for, Door frame and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws,all as per architectural drawings, complete all as specified and directed. |
| 3 | M&L for 12 mm thick prelaminated particle board exterior grade,prelaminated both sides with decorative choice laminaions fixed with EPDM rubber /neoprene gasket etc to aluminium frame in lower pane, complete all as specified and directed |
| 4 | S&F 5.5mm thick Sheet glass,ordinary quality and glazing fiexed to Aluminiu Partition with required EPDM rubber/neoprene gasket etc n exc 0.5 sq. m in each pane in upper portion, complete all as specified and directed. |
| 5 | S & F of Powder coated aluminium of any colour (Thickness of powder coating not less than 50 micron ) anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including providing and fixing hinges/pivots and making provision for fixing of fittings whereever required ,necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as door stopper double leged (1 No.). hinges type B-21 125mm long (3 Nos.) suitable handles 2 Nos including Mortice lock arrangment and frosted glass 5.5mm thk in upper panel and 12mm thick Prelaminated decorated on both face Particle board sheet in lower Panel .) for each shutter, complete all as specified and as directed. |
| 6 | M&L for brickwork with old sized subclass 'B' bricks straight or curved on plan exc 6m mean radius and built in CM 1:6 etc including demolition of brick work, complete all as specified and directed. |
| 7 | M&L for glazed ceramic coloured tiles of size not exceeding 450x350x7mm or 350x250 x7mm thick as skirting/dado, wall, on vertical surface etc . ,set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile with and including 10mm thick backing coat in CM 1:4 (if reqd in any portion), including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) etc. removing rubbish off the premises, complete all as specified and directed. |
| 8 | M & L for rendering 15mm thick cement plaster in CM (1:4) on brick work or concrete surfaces finished even and fair without using, extra cement all as specified and directed. |
| 9 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of primer, complete all as specified and directed. |
| 10 | M & L for complete removal of existing paint on old surface of wall/ceiling and p apply one coats of oil bound distemper, complete all specified and directed. |
| 11 | Demolition of Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 12 | Excavating in post holes each n.exc 0.5 cum getting out in soft/loose soil and removing surplus soil to a distance n.exc 50 m and making good surface complete.all as specified and directed |
| 13 | M & L for plain cement concrete 1:4:8 Type D-2 (using 40mm graded crushed stone aggregate) 75mm thick, as in sub base over rammed earth, complete all as specified and as directed. |
| 14 | M&L for plain cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) 40mm thick, as in flooring, rough finished, complete all as specified and directed. |
| 15 | M & L for plain cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in post/strut foundation, complete all as specified and directed. |
| 16 | S & F mild roof structural steel angles/rectangular hollow section/steel tubular roof trusses (framed), purlines and fastening including distance pieces etc., complete all as specified and directed. |
| 17 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed |
| 18 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer, complete all as specified and directed. |
| 19 | M&L 6mm thick Non Asbestos fibre cement /Pre Laminated self embosssed texture designer board E-Board classic size 595x595mm, HPSC (High pressure steam cured) to be fixed or inserted to pre laminated GI frame work for seamless ceiling size 600mm x 600mm with main runner 38x24x0.9mm thick, cross tee 8.6x24x0.9mm and wall angle 19x19x0.9mm duly suspended with 2mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip, complete all as specified and directed. |
| 20 | M & L for cutting, bending, welding cold or hot incl drilling, jointing, assembly and making different type/size as req shape and size of fitting and fixture any other desc shape as per user req or all as decided, specified and directed by EIC with making shape of multipurpose and multi storey type cabin of rack shape shelves like vertical colns/tiers/shelves based type with help of providing and fixing stainless steel grade 304 rack, channels, plates, solid plate sheet, cross arms, angle,m channel or any type/ size of stainless steel grade 304 etc incl welding, grinding, buffing, polishing and make curvatures and fitting the same with stainless steel nuts and bolts complete incl fixing the shelves with necessary accessories & stainless steel fasteners, bolts etc of req size on the shelves or the side of waist slab along with providibng suitable arrangement for fabricated structural steel sections of rack work for use inside a walk-in-cold room as designed for blood storage system, complete all as specified and directed. |
| 21 | Supply, fixing, installation, testing and commissioning of modular type pre fabricated panel with inbuilt filled PUF insulating insulation material, easy to assemble at site for construction of Walk in cold room of two chambers one is Freezer room of inside area dimension/size 8'x8'x8' consisting of wall and ceiling panel made out of PPGI sheet filled inbuilt with 120 mm/125 mm PUF insulated insulation and Ante room of inside area dimension/size 6'x6'x8' consisting of wall and ceiling panel made out of PPGI sheet filled inbuilt with 60 mm PUF insulated insulation for blood bank and other low temperature applications also providing of pre fabricated anti skid GI flooring panel with inbuilt filled 60 mm PUF insulating insulation for both rooms with suitable dimension / size of doors with mechanical hydraulic door closer, handle & hinges of suitable any type/size and any other connecting fixing/jointing accessories for assembling of cold room system as per manufacture recommended and also providing of 02 Nos of Air cooled low temperature split unit yielding approximately 2 Tons capacity of refrigeration or not less than 20000 BTU/Hour of refrigeration for air conditioning of system with actual cooling effect one as working and one standby unit operating on 415 volt 3 phase 50 Hz AC power supply system along with having reciprocating/scroll compressors working on R- 22/R-410a/R-404A or any other refrigerants to maintain and achieve low temperature of 4+ / - 2 degree centigrade at an ambient temperature of 30 degree centigrade. The 02 Nos of Air cooled condensing and evaporating unit one as working and one stand by unit and both unit will work /run alternatively as a twin cooling unit system. The outdoor condensing unit having energy efficient compressor, condenser ,fan motor with inbuilt safety and control devices etc along with high efficiency heat transfer and low power consumption and inner grooved copper |
| 22 | tubes with slit aluminum fins for superior heat transfer and indoor evaporating unit having inner grooved copper tubes and having compact, slim and sleek stainless steel body and excellent corrosion resistance along with external forced uniform air circulation by heavy duty rotor driven fan with low noise level and conform to standard IP protection system. Both the unit system chambers should be provided uninterrupted with twin cooling function and are working as back up to each other by switch over refrigeration system with the help of automatic programming of the system unit and ensure to work for uninterrupted cooling of the system. The modular type pre fabricated panel work dully jointing & inter locking with the help of tongue and groove/metallic cam lock system or as per manufacture design system and also providing of suitable type/size of opening and closing type of window on wall with sealed packed air airtight heavy duty sealing gasket based with duly locking arrangement system near by freezer room door area for transfer of cooling from freezer room area to Anti room area if required in future and also for better safe & safety purposed along with providing of 02 no's of heavy duty doors with viewing windows / ports and providing of safety release, facility to open the door from inside room in case of door locked with emergency bell having switch inside chamber along with air airtight heavy duty sealing gasket below the door remains flexible sweep gasket/magnetic gasket at low temperature and also making arrangement of moveable interior & exterior ramp, auto door close mechanisms inside of both room and having of controller wiring with LED lighting and control system for both room |
| 23 | Providing of 02 Nos of separate temperature controller display with digital indication cum controller unit system one as working and one standby operating unit duly inter connected and operation programming to each other as stand by system with precise indicating ,control and to display for all operating functions and parameter along with communication of all fault & failure alarm along with advance safety features facility beyond specified limit including providing of extra refrigerants gas for filling in refrigerants pipe line system along with providing of extra copper pipe line any lengthy with suitable type/size for both suction and discharge/liquid copper refrigerant pipe line along with filter drier for moisture and dirt protection with service open/ closing valve. Both the refrigerant pipe line system duly interconnected from outdoor unit to indoor unit attachment system and these pipe lines must be duly covered by insulated materials to prevent any condensation and insulation exposed to the weather must have additional protection over the same system and also providing of drain pipe line arrangement for waste water generated from system complete job all as specified ,decided & directed by Accepting officer / Engr In Charge Please Enable Macros to View BoQ information |
| 24 | Providing of 02 Nos of separate temperature controller display with digital indication cum controller unit system one as working and one standby operating unit duly inter connected and operation programming to each other as stand by system with precise indicating ,control and to display for all operating functions and parameter along with communication of all fault & failure alarm along with advance safety features facility beyond specified limit including providing of extra refrigerants gas for filling in refrigerants pipe line system along with providing of extra copper pipe line any lengthy with suitable type/size for both suction and discharge/liquid copper refrigerant pipe line along with filter drier for moisture and dirt protection with service open/ closing valve. Both the refrigerant pipe line system duly interconnected from outdoor unit to indoor unit attachment system and these pipe lines must be duly covered by insulated materials to prevent any condensation and insulation exposed to the weather must have additional protection over the same system and also providing of drain pipe line arrangement for waste water generated from system complete job all as specified ,decided & directed by Accepting officer / Engr In Charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender