Tender For Design (Confirming Of Relevant Is), Supply, Installation, Testing And Commissioning Of Electrical Works For Transit Accommodation For Kashmiri Migrants At Zewan
Tender Value
1.13 Crore
Estimated cost
Bid Submission
02 Sep 2026
17 days left
EMD
2.27 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Design (Confirming Of Relevant Is), Supply, Installation, Testing And Commissioning Of Electrical Works For Transit Accommodation For Kashmiri Migrants At Zewan
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing of 9.0 mtr Long GI (65 micron DFT single dip) octogonal poles uniformally tappered with thickness of 3mm with bottom/top Dia of 155 mm x 70mm & base plate of 260x260x16mm/pcd 260 mm provided with proper door opened gear box for connections on the bottom side. The pole numbering with KPDCL to be marked on each pole. |
| 2 | Providing and fixing of 7.0 mtr Long GI (65 micron DFT single dip) octogonal poles uniformally tappered with thickness of 3mm with bottom/top Dia of 130 mm x 70mm & base plate of 220x220x12mm/PCD 220 mm provided with proper door opened gear box for connections on the bottom side. The pole numbering with KPDCL to be marked on each pole. |
| 3 | Providing and Laying of RCC foundation in M15 mix for 9.0 mtr. Long Octogonal pole (2ftx2ftx5ft) with 4'U/G including cost of Template (As per foundation drawings) including the cost of shuttering & curing. |
| 4 | Providing and Laying of RCC foundation in M15 mix 1:2:4 for 7.0 mtr. Long Octogonal pole (2ftx2ftx5ft) with 4'U/G including cost of Template (As per foundation drawings) including the cost of shuttering & curing. |
| 5 | Providing and fixing of G.I. foundation bolts 4x 750 x 24 mm long (set of 4 no's per pole) to be fixed with the Tar steel of Foundation along with MS rings. |
| 6 | Providing and fixing of G.I. foundation bolts 4x700 x 20 mm long (set of 4 no's per pole) to be fixed with the Tar steel of Foundation along with MS rings. |
| 7 | Providing and laying of earthing of poles Including 8 No GI wire and 1.5 inch dia, 3 ft long G.I. pipe dully welded. |
| 8 | Providing and fixing of Pre fabricate galvanized Iron (65 microns) two way top bracket of ornamental desing to be fitted on top of Octogonal pole for holding lighting Luminaries |
| 9 | Providing and fixing of Pre fabricate galvanized Iron (65 microns) one way top bracket of ornamental desing to be fitted on top of Octogonal pole for holding LED Luminaries |
| 10 | Cable Termination & Luminary connections using 4-way terminal block/ connectors 100 ampere capcity & one no. of 2 amp MCB strip (Legrand/Havells make) including copper lugs, nuts& bolts,washers etc for poles with one way type bracket to be fitted properly inside the door opened gear box provided on the bottom side of the pole. |
| 11 | Supply installation testing and commissioning of Cable Termination & Luminary connections using 4-way terminal block/ connectors 100 ampere two no. of 2 amp MCB strip (Legrand/Havells make) including copper lugs, nuts& bolts,washers etc for poles with two way type bracket be fitted properly inside the door opened gear box provided on the bottom side of the pole. |
| 12 | Supply, installation testing & commissioning 120 watt LED Luminary IP-67 die-cast Aluminum120-130 LPW efficacy (total lumen flux minmum 15600 Lumens LM/Watt , clear toughened glass, powder coated Grey outer finshish IK08,10KV SPD & inbuilt SPD 05KV greater than 50000 burning hours |
| 13 | Supply, installation testing & commissioning 90 watt LED Luminary IP-67 die-cast Aluminum 120 LP/W, total lumens flux ,minmum 10800(lumen) & inbuilt SPD 05KV M/Watt , clear toughened glass, powder coated Grey outer finshish IK08, greater than 50000 burning hours |
| 14 | Providing and laying of 1.5 sq.mm PVC insulated multistrand flexible copper wire for service connections from connection plate to the LED luminary indidual circuit including loop & earthings laid properly (Havells/Polycab/Paramount make) |
| 15 | Providing and laying of 25 Sq.mm, 4.0 core PVC armoured cable to be laid U/G or A/G only in case of site constrains conform to relevant IS specification with updated amendments. (Havells/Polycab/Paramount make) |
| 16 | Providing and laying of 16 Sq.mm, 4.0 core PVC Aluminium armoured cable to be laid U/G or A/G only in case of site constrains conform to relevant IS specification with updated amendments. (Havells/Polycab/Paramount make) |
| 17 | 25/16 Sq.mm Alumunium cable thimbles/lugs at termination points including providing of insulation tape. |
| 18 | HDPE pipe 50 mm O/D including trench excavation in hard soil 1ft(w)x 2 ft (D) for laying of 25/16 sq mm almunium armound/unarmoured cable.The job further includes refilling back the same and removal of surplus excavated material to an appropriate place. |
| 19 | Supply installation testing and commissioning of Cable 25 KVA 3 phase servo control stabliser oil cooled with input voltage of 160-450 volts, 50 HZ and a constant out put voltage of 400 volt including the canopy of suitable size to protect during raining and snowing.The Stabliser shall be provide with high and low cut off voltage system, oveload/under load single phase protectio and also shall resist the input and out put +5% tolerance. the item includes cost of thimbling, lugs & other spares as required at input and output taping point. .The Stabiliser shall be paited as per standards & of (AE/Andrew Yule make) with warranty period period of two years from the date of commissioning. |
| 20 | Canopy type Double door dust & corossion free LT feeder panel 3'x4'x1'6\\" fabricated out of sheet steel of adequate guage not below than 1.8mm for external use with 2 incoming circuits of 32 Amp. 4 pole MCCB main control fitted with Manual operated portable bypass change over swich control for AVR including 4 strip copper busbar of sufficient capacity with out put circuit carrid through 2 no. 16 Amp. 4 pole MCCBs for 2-outgoing circuits. The panel shall also be provided with Automatic astronomical timmer switching controlls for each out going circuits for operation of street Lights with sets of voltmeter, ampere meter, indicators and backup protection for panel of required capacity. The panel is to be supported on 4 no. angle iron stool of (50x50x6mmx3') sized legs to be grouted in cement concreate exluding the cost of RCC bed.The electric equipments/parts must be of Schneider/Andrew Yule |
| 21 | Supply installation testing and commissioning of Cable Providing of seperate earthings for AVR & LT panel by way of digging 10 ft. deeep earth pit embedding a 2ft*2ft*4mm thick copper plate as main earthing electrode, connecting the plate with main control panel by 10 SWG copper wire with 1/2 \\" dia. Full thread brass nuts, bolts and washers, refilling the pit with alternate layers of salt charcoal and earth. |
| 22 | 25 Sq.mm, 4.0 core armoured copper cable to be laid U/G or A/G only in case of site constrains conform to relevant IS specification with updated amendments for main connction. (Havells/Polycab/Paramount make) |
| 23 | Construction of 6' x 3' PCC bed for AVR 7 LT panel in M15 mix with a total height of 2' A/G & 1' U/G on uniformly spreded 4'' thick soling lyer including cost of shuttering as required .The top layer of 6\\" to be laid in RCC M10 (Tar steel 10 mm with spacing of 6 \\"'x6\\") to avoid any damages to the bed.The RCC portion shall include in the total height of 2' .The sides A/G to be provided chieseled stone tiles including plasterter in 1:4 mix . The item includes shuttering & excation of under ground trench, carraige/transportation of construction materials up to the site with removal of surplus excavated material from site to dumping place. |
| 24 | Providing and fixing of Sign board of appropriate size (2'x1'6'') painted with details of the work like name dof the Deptt,work, Head of the account, date of start and date of commisioning any other detail as required. |
| 25 | Providing and fixing of 9 Mtr. Long ST Pole 410 SP 33 as per IS 2713 (Part I & II) including two coats of Aluminium paint. |
| 26 | Providing and laying of of 50 MM² AB Cable 3 core |
| 27 | Providing and fixing of GI suspenssion hook/holding clamp |
| 28 | Providing and laying of 50 mm² ABC cable termination KIT of standard make |
| 29 | Providing and laying of 50 MM² ACSR conductor (Rabbit) |
| 30 | Providing and fixing of GI Channel iron 100x50x50x6mm 9' long (02 No.) with two coats of Aluminium |
| 31 | Providing and fixing of GI Channel iron 75x40x40x6 mm 8' long (8No.) with two coats of Aluminium |
| 32 | Providing and fixing of GI Channel iron 75x40x40x6 mm 6' long (2No.) with two coats of Aluminium |
| 33 | Providing and fixing of GI Angle Iron braces 50x50 x6mm 5' long (04 No.) with two coats of Aluminium |
| 34 | Providing and fixing of GI Angle Iron braces 50x50 x6mm 6' long (02 No.) with two coats of Aluminium |
| 35 | Providing and fixing of MS Nuts & Bolts /Washers (Galvanized of sorts) |
| 36 | Providing and laying of GI Strip for earthing. |
| 37 | Supply installation testing and commissioning 25 KV Transformer 11Kv/433V 50 Hz 3Ø with bi Matallic terminal connectors Energy level 2 copper Wound |
| 38 | Providing and laying of 35 mm² PVC 3.5 Core |
| 39 | Providing and fixing of Solderless Clamps |
| 40 | Providing and fixing of 11 KV Gang Operating Air Break Switch |
| 41 | Providing and fixing of 11 KV Disc insulator with complete fittings |
| 42 | Providing and fixing of 11 KVA Drop-out set (Horn-gap type) |
| 43 | Providing and fixing of 11KV Lighting Arrester Set ( Station type) |
| 44 | Providing and fixing of 11 kV Pin Insulators (polymer/porcelain) with Pins( 5 KN) |
| 45 | Providing and laying of Earthing for Sub-Station |
| 46 | Providing and laying of Earthing insulating boots with clamps |
| 47 | Providing and fixing of GI Angle Iron for Transformer Belt 50x50x6mm 10' longwith two coats of Aluminium |
| 48 | Providing and fixing of Anti-Climbing Device with Clamps |
| 49 | Providing and laying of Cement Bottoming of 9 mtr ST poles |
| 50 | Providing and fixing of Danger Plates with Clamps Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender