Tender For Repair/Maint Of Certain Misc E/M Equipment Such As Smoke Detector/Fire Alarm System/Window/ Spilit Air - Conditioning/ Aviation Light Along With Connected E/M Work At Af Stn Nathatop
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Sep 2026
10 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Certain Misc E/M Equipment Such As Smoke Detector/Fire Alarm System/Window/ Spilit Air - Conditioning/ Aviation Light Along With Connected E/M Work At Af Stn Nathatop
BOQ
| Sl. No. | Item Description |
| 1 | M&L for point wiring complete with PVC insulated and unsheathed cable 4.00 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20 mm dia 'medium grade' PVC conduit for point wiring in concealed in wall/false ceiling / surface with pressed steel concealed Sunken boxes not less than 1.6 mm thick of reqd size (factory painted) and with top cover 3 mm thick one coat of red oxide primer complete including 4 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ] |
| 2 | S & F in repair outdoor type 6 way DISTRIBUTION BOX with auto closing of lid shall be made out of Polystyrene with suitable fixing arrangement of minimum dimension 238 x 146 x 111 mm (the cable size upto 25 sqmm). The DB box shall be environmental friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Box shall be rated for Degree of ingress Protection IP 65 in accordance with IEC 60529.Weatherproof, UV resistant and the gasket shall be internally embedded alongwith cable. The DB Box shall be fitted with Bus Bar and suitable clamps, nut bolts and washers for fixing on wall including taking down old unsv AC metal socket / Metal DB etc complete all as specified and directed.MAke Hensel KV 7106Note: Contractor shall produce OEM test certiifcate. |
| 3 | M&L in repair of metal single-pole and earth enclosure with three-pin and earth plug plus neutral with socket 20/32 Amps SP 240Volts complete industrial type complete all as specified and directed |
| 4 | M&L in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface/concealed in PVC casing caping/ PVC conduit heavey duty and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 4.00 sqmm main cable and one RM of 4 .00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose. |
| 5 | All as per item No 4.00 hereinbefore but size of sub main 6 sqmm complete all as specified and directed |
| 6 | All as per item No 4.00 hereinbefore but size of sub main10 sqmm complete all as specified and directed |
| 7 | Supply and fix in repair of Integral LED aviation light luminaire in yellow/red die-cast aluminium alloy housing with red coloured polycarbonate dome of including necessary electric connection 2.5 sqmm 3 core pvc insulated PVC copper cable as per manufacture's requirement and building /tower height up to 30mtr complete all as specified and as directed by Engineer-in-Charge.Cat part No BGAV 302 LED of make Bajaj or equivalent C&S/CG/Philips |
| 8 | M&L Takingdown spilit type air conditioning of capacity 1.5 ton non inverter type for checking of all spare parts and serving including out door/indoor units complete all as specified and directed |
| 9 | M&L for Servicing and maintanence for Indoor and outdoor unit of non inveter type split Air conditioners 1.5 Ton capacity taking down carefully indoor unit servicing and cleaning of filter, blower, Indoor coil assy, PCB, terminal block, frame grill assy incl greasing for blower motor complete with reassembling the same one, including good cleaning carefully for outside area used soft cloth with colin/ shop and testing the same to the entire satisfaction of Engineer-in-Charge, complete all as directed. |
| 10 | Supply only the following spare parts for window/spilit type air conditioning shall be measured, paid seperately under respective schedule |
| 11 | M&L in repair for Disconnecting, cutting and taking out Evaporated Coil for indoor unit for 1.5 ton Non invertor type find out gas leaking area and brazing work complete and cleaning refitting with testing complete all as specified and directed by the Engineer-in-charge. |
| 12 | M&L in repair for condensing coil disconnecting, cutting and taking out outdoor unit Condensing coil for outdoor unit for 1.5 ton AC Non invetor type cheacking of gas leaking area and brazing work complete and refitting with testing complete all as specified and directed by the Engineer-in-charge. |
| 13 | M&L in repair/replacement compressor for 1.5 Ton silit AC non invertor type including soldering /brazing as required with gas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge.Make : Highly/Bluestar/LLoyd/Carrier |
| 14 | S & F for in repair/replacement Panel control Board of non invrter type AC including remote and display of 1.5 Ton AC, complete all as specified and directed by the Engineer-in-charge. Make : as per existing |
| 15 | M & L for in repair Indoor unit blower motor for 1.5 Ton capacity AC non inverter type complete, all as specified and directed by the Engineer-in-charge. Make : as per existing |
| 16 | M & L for in repair/replacement of Copper filter / strainer for 1.5 ton split AC non inverter type as per existing make and model complete all as specifed and as directed |
| 17 | M&L Takingdown spilit type air conditioning of capacity 1.5 ton inverter type for checking of all spare parts and serving including out door/indoor units complete all as specified and directed |
| 18 | M&L for Servicing and maintanence for Indoor and outdoor unit of inverter type split Air conditioners 1.5 Ton capacity taking down carefully indoor unit servicing and cleaning of filter, blower, Indoor coil assy, PCB, terminal block, frame grill assy incl greasing for blower motor complete with reassembling the same one, including good cleaning carefully for outside area used soft cloth with colin/ shop and testing the same to the entire satisfaction of Engineer-in-Charge, complete all as directed. |
| 19 | Supply only the following spare parts for window/spilit type air conditioning shall be measured and paid seperately under respective schedule |
| 20 | M&L in repair for Disconnecting, cutting and taking out Evaporated Coil for indoor unit for 1.5 ton invetor type find out gas leaking area and brazing work complete and cleaning refitting with testing complete all as specified and directed by the Engineer-in-charge. |
| 21 | M&L in repair for condensing coil disconnecting, cutting and taking out outdoor unit Condensing coil for outdoor unit for 1.5 ton AC invetor type cheacking of gas leaking area and brazing work complete and refitting with testing complete all as specified and directed by the Engineer-in-charge. |
| 22 | M&L in repair/replacement compressor for 1.5 Ton silit AC invertor type including soldering /brazing as required with gas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge.Make : Highly/Bluestar/LLoyd/Carrier |
| 23 | S & F for in repair/replacement Panel control Board of invrter type AC including remote and display of 1.5 Ton AC, complete all as specified and directed by the Engineer-in-charge Make : as per existing |
| 24 | M & L for in repair Indoor unit blower motor for 1.5 Ton capacity AC inverter type complete, all as specified and directed by the Engineer-in-charge. Make : as per existing |
| 25 | M & L for in repair/replacement of Copper filter for 1.5 ton split AC inverter type as per existing make and model complete all as specifed and as directed |
| 26 | M&L Takingdown spilit type air conditioning of capacity 2.00 ton non inverter type for checking of all spare parts and serving including out door/indoor units complete all as specified and directed |
| 27 | M&L for Servicing and maintanence for Indoor and outdoor unit of non inveter type split Air conditioners 2.00 ton capacity taking down carefully indoor unit servicing and cleaning of filter, blower, Indoor coil assy, PCB, terminal block, frame grill assy incl greasing for blower motor complete with reassembling the same one, including good cleaning carefully for outside area used soft cloth with colin/ shop and testing the same to the entire satisfaction of Engineer-in-Charge, complete all as directed. |
| 28 | Supply only the following spare parts for window/spilit type air conditioning shall be measured and paid seperately under respective schedule |
| 29 | M&L in repair for Disconnecting, cutting and taking out Evaporated Coil for indoor unit for 2.00 ton Non invetor type find out gas leaking area and brazing work complete and cleaning refitting with testing complete all as specified and directed by the Engineer-in-charge. |
| 30 | M&L in repair for condensing coil disconnecting, cutting and taking out outdoor unit Condensing coil for outdoor unit for 2.00 ton AC Non invetor type cheacking of gas leaking area and brazing work complete and refitting with testing complete all as specified and directed by the Engineer-in-charge. |
| 31 | M&L in repair/replacement compressor for 2.00 ton silit AC non invertor type including soldering /brazing as required with gas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge.Make : Highly/Bluestar/LLoyd/Carrier |
| 32 | S & F for in repair/replacement Panel control Board of non invrter type AC including remote and display of 2.00 ton AC, complete all as specified and directed by the Engineer-in-charge. Make : as per existing |
| 33 | M & L for in repair Indoor unit blower motor for 2.00 ton capacity AC non inverter type complete, all as specified and directed by the Engineer-in-charge. Make : as per existing |
| 34 | M & L for in repair/replacement of Copper filter for 2.00 ton split AC non inverter type as per existing make and model complete all as specifed and as directed |
| 35 | M&L Takingdown spilit type air conditioning of capacity 2.00 ton inverter type for checking of all spare parts and serving including out door/indoor units complete all as specified and directed |
| 36 | M&L for Servicing and maintanence for Indoor and outdoor unit of inveter type split Air conditioners 2.00 ton capacity taking down carefully indoor unit servicing and cleaning of filter, blower, Indoor coil assy, PCB, terminal block, frame grill assy incl greasing for blower motor complete with reassembling the same one, including good cleaning carefully for outside area used soft cloth with colin/ shop and testing the same to the entire satisfaction of Engineer-in-Charge, complete all as directed. |
| 37 | Supply only the following spare parts for window/spilit type air conditioning shall be measured and paid seperately under respective schedule |
| 38 | M&L in repair for Disconnecting, cutting and taking out Evaporated Coil for indoor unit for 2.00 ton invetor type find out gas leaking area and brazing work complete and cleaning refitting with testing complete all as specified and directed by the Engineer-in-charge. |
| 39 | M&L in repair for condensing coil disconnecting, cutting and taking out outdoor unit Condensing coil for outdoor unit for 2.00 ton AC invetor type cheacking of gas leaking area and brazing work complete and refitting with testing complete all as specified and directed by the Engineer-in-charge. |
| 40 | M&L in repair/replacement compressor for 2.00 ton silit AC invertor type including soldering /brazing as required with gas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge.Make : Highly/Bluestar/LLoyd/Carrier |
| 41 | S & F for in repair/replacement Panel control Board of invrter type AC including remote and display of 2.00 ton AC, complete all as specified and directed by the Engineer-in-chargeMake : as per existing |
| 42 | M & L for in repair Indoor unit blower motor for 2.00 ton capacity AC inverter type complete, all as specified and directed by the Engineer-in-charge. Make : as per existing |
| 43 | M & L for in repair/replacement of Copper filter for 2.00 ton split AC inverter type as per existing make and model complete all as specifed and as directed |
| 44 | M & L for in repair running capacitor 45 mfd + 3 mfd for 1.5 ton AC (combined unit) complete, all as specified and directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark |
| 45 | M & L for in repair running capacitor 50+4 mfd for 2.0 ton AC (combined unit) complete, all as specified and directed by Engineer-in-Charge. Make :- Apcos/Natraj/Tesla/Spark |
| 46 | M & L for in repair route pipe (copper tube) of size 3/8\\" dia complete with insulation complete all as specified and directed by Engineer-in-Charge. |
| 47 | M & L for in repair route pipe (copper tube) of size 5/8\\" dia complete with insulation complete all as specified and directed by Engineer-in-Charge. |
| 48 | M & L for in repair route pipe (copper tube) of size 1/4\\" dia complete with insulation complete all as specified and directed by Engineer-in-Charge. |
| 49 | Supply and refilling of gas R-22 & 32 in 2 .0 /1.5 Ton AC including necessary arrangement for gas filling complete all as specified and directed by Engineer-in-Charge. |
| 50 | Supply and replacement of PVC drain pipe suitable for All type AC complete all as specified and as directed by the Engineer-in-charge. |
| 51 | M&L refixing of the split type Air conditioning of capacity 1.5 Ton from one location to another location including taking out including servicing Testing/commissioning etc all as speciefied and as directed |
| 52 | M&L refixing of the split type Air conditioning of capacity 2.00 Ton from one location to another location including taking out including servicing Testing/commissioning etc all as speciefied and as directed |
| 53 | M&L Takingdown voltage stablizer of capacity 2 KVA for transportation to civil market from Nathatop to Udhampur or as authorised factory for repair/replacement parts and checking of all spare parts including serving and refixing the same in original locatiion after repair including electrical connection complete all as specified and directed. |
| 54 | M&L in repair of electronic Voltage stabilizer of capacity 3 KVA for automatic operation, single phase naturally air cooled indoor type & designed low and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and directed by Engineer-in-Charge.Note : Spare parts shall be measured and paid seperately |
| 55 | Supply only the following spare parts for voltage stablizer of capacity 2/3 KVA shall be measured and paid seperately under respective schedule |
| 56 | Supply only in repair/replacement of control card for voltage stabilizer of capacity 2.00 KVA with PCB sensor etc make and model as per existing complete all as specified and directed by Engineer-in-Charge. |
| 57 | M&L Takingdown voltage stablizer of capacity 4.00 to 5.00 KVA for transportation to civil market from Nathatop to Udhampur or as authorised factory for repair/replacement parts and checking of all spare parts including serving and refixing the same in original locatiion after repair including electrical connection complete all as specified and directed. |
| 58 | M&L in repair of electronic Voltage stabilizer of capacity 5.00 KVA for automatic operation, single phase naturally air cooled indoor type & designed low and high voltage cut out protection for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and directed by Engineer-in-Charge.Note : Spare parts shall be measured and paid seperately |
| 59 | Supply only the following spare parts for voltage stablizer of capacity 4.00 to 5.00 KVA shall be measured and paid seperately under respective schedule |
| 60 | Supply only in repair/replacement of control card for voltage stabilizer of capacity 4.00 to 5.00 KVA with PCB sensor etc make and model as per existing complete all as specified and directed by Engineer-in-Charge. |
| 61 | M&L in replacement Electronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed low and high voltage cut out protection for input variation between 90 Volt to 300 Volt with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA complete all as specified and directed by Engineer-in-Charge.Make : V Guard/Voltas/Livguard |
| 62 | M&L in replacement Electronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed low and high voltage cut out protection for input variation between 90 Volt to 300 Volt with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 6 KVA complete all as specified and directed by Engineer-in-Charge.Make : V Guard/Voltas/Livguard Please Enable Macros to View BoQ information |
| 63 | M&L in replacement Electronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed low and high voltage cut out protection for input variation between 90 Volt to 300 Volt with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 6 KVA complete all as specified and directed by Engineer-in-Charge.Make : V Guard/Voltas/Livguard Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender