Tender For Certain Special Repairs And Minor Works In The Aor Of Age E/M At Mil Stn Kapurthala Under Ge Kapurthala.
Tender Value
43.64 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
10 days left
EMD
87280
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kapurthala → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Certain Special Repairs And Minor Works In The Aor Of Age E/M At Mil Stn Kapurthala Under Ge Kapurthala.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Certain special repairs and minor works in the AoR of AGE E/M at Mil Stn Kapurthala under GE Kapurthala. Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC (FR) insulated cable in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.5 Sqmm insulated un-sheathed PVC insulated copper conductor common earth and connecting to earth dolly for :- (a) One socket outlet 3 Pin, 5 Amp on independent board |
| 3 | S&F of switch piano flush type single pole one way 6 Amp (ISI Marked) |
| 4 | S&F of socket out let 2 in 1, 3 pin 5 Amp flush type (ISI Marked) |
| 5 | S&F of ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CMM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and connecting up and including provision of twisted three core PVC insulated flexible cord of 0.75 Sqmm copper conductor of required length from ceiling rose/connector to fan complete all as specified and directed. |
| 6 | S&F of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc; as reqd |
| 7 | Supply, Installation and testing of desert cooler electric driven (Single phase) as per followoing specification:-Size of Desert Cooler:- L x b x h 660 x 660 x 825 mm (26\\" x 26\\" x 32.5\\") ApproxBody:- (i) steel body top cover and pillars of 18 SWG (1.20 mm) thick GI sheet (ii) Side panels of 20 SWG (1.00 mm) GI Sheet (iii) Tank height 7\\" made of 18 SWG (1.20 mm) GI Sheet (iv) Front grill and directional grill of GI sheet. (v) Including required iron stand made up of 40 mm angle iron as directed.Fan Motor:- (i) Exhaust fan motor should be copper winding, 500 mm sweep cooler fan, double ball bearing, three speed (High/Medium/Low) with methalic blade duly painted with snthetic anti corrosive oven cured paint fitted to body fan motor.(ii) Input cap 200 watt(approx), speed 1400 RPM, 230 Volts, 50 Hz, air delivery 5000/6000 Cum/Hrssubmersible Pump Motor:- Input cap 40 watt (Approx), speed 1300 RPM, 230 volts, 50 Hz.Switches/regulator:- One piano switch and one speed selector switch (Regulator) 04 position for controll of pump motor and fan motor respectively will be provided on the body.Pads:- Wood wool pads of proper Thickness will be provided in each panel (Set of three).Drain Plug:- Brass drain plug shlall be provided from pump motor to three panel fitted on the cooler body.Cord:- Flexible cord PVC shethed and Insulated size 40/0.25 mm (1.5 Sqmm) 3 core (as per IS 94/1977) length 5 Mtr long with three pin 5 Amp ISI marked bakelite plug top shall be provided for power supply to cooler.Note:- (i) All desert cooler should be fitted on first floor or second floor minium height is 8 mtr (ii) Contrctor should be provide all sefty material for worker for installation of desert cooler (iii) Contrator should be submitted 01 year guarntee/waranty of desert fan motor and submersibale pump motor. |
| 8 | S&F of digital street light timer panel factory made of rating 40A, conforms to IS/IEC 60947-4-1, provided with Protection Degree IP 54, extended wide band coil, FRLS (Fire retardant low smoke) internal wiring, in-built short-circuit protection, class H insulation including 40Amps TP MCB 'B' Curve, 10 KA, 415V and Time switch with contactore TPN 40 A, 'C' curve, 10 KA, 415V including selector switch complete all as required. |
| 9 | Supply and installed desert cooler electric driven (single phase), having nominal air flow capacity of 4000 Cum per hour (or nearest size) with following specifications :-.Body:- (i) PVC body with tank capacity min 75 ltr Inclding Iron stand made of 40 mm angle iron as required.Fan Motor:- (i) Exhaust fan motor should be copper winding, min 300 mm sweep cooler fan, double ball bearing, three speed (High/Medium/Low) with PVC/methalic blade duly painted with snthetic anti corrosive oven cured paint fitted to body fan motor make from GP-I of PS will be applicable. (ii) Input capacity 200 watt(approx), speed 1400 RPM, 230 Volts, 50 Hz, air delivery 4000 Cum/HrsSubmersible Pump Motor:- Input cap 40 watt (Approx), speed 1300 RPM, 230 volts, 50 Hz.Switches/Regulator:- One switch and one speed selector switch (Regulator) 04 position for controll of pump motor and fan motor respectively will be provided on the body.Pads:- High density honey comb cooling pads of proper thickness will be provided in each panel (Set of three).Drain Plug:- Drain plug shlall be provided from pump motor to three panel fitted on the cooler body along with 01 nos of float valve.Cord:- Flexible cord PVC shethed and Insulated size 40/0.25 mm (1.5 Sqmm) 3 core (as per IS 694/1977) length 5 Mtr long with three pin 5 Amp ISI marked bakelite plug top shall be provided for power supply to cooler.Note:- (i) All desert cooler should be fitted on first floor or second floor minium height is 8 mtr(ii) Contrctor should be provide all sefty material for worker for installation of desert cooler(iii) Contrator should be submitted 01 year guarntee/waranty of desert fan motor and submersibale pump motor. |
| 10 | S&F of electric water heater stoarage type steel/ABS body with mettalic inner tank & heating element upto 2KW capacity 25Ltr, BEE 5 Star rated AC 230 volts, 50 Hz vertical type including M&L for grouting four Nos rack bolt to holding water heater on wall including making good and match existing surfaces complete with all accessories such as safety valve, thermostate, NRV, steel braided connection piece of 450 mm long complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for sub main wiring with two runs of single core PVC insulated FRLSH, unsheathed copper condutor, multi stranded cable of size 2.5 Sqmm 1100 volts grade drawn PVC surface conduit of size 19/20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc; including one run of 2.5 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note:- Two run of 2.50 Sqmm cable one run of 2.50 Sqmm cable as earth continuity conductor and one run of PVC conduit shall be measured & paid as one unit.) |
| 12 | S&F of sheet metal enlosure single pole and neutral with two pin socket and earth plug complete with one MCB single pole B-series, 240 volts 20 Amps complete all as specified and directed. |
| 13 | S&F of GI pipe medium grade with all fittings like bends, joints, tees, socket, mouth plug etc as required on site to fixed on wall with all connection accessories of size 15 mm bore complete all as specified and directed. |
| 14 | M&L for hot water tap of brass/gun metal 15 mm bore complete all as specified and as directed. |
| 15 | S&F of gun metal globe or stop valves with iron wheel head screwed both ends for iron pipe and fixed of size 15 mm dia complete all as specified and directed. |
| 16 | Dismantling/Taking out ACSR conductor/GI wire complete. |
| 17 | Dismantling/Taking out XLPE cable of any size and type |
| 18 | M&L for 40 mm nominal bore tube light gread GI laid under road/culvert/drain fixed to pole wall with help of flat iron clamps etc for cable protection for complete all as specified and as directed. |
| 19 | M&L for 50 mm nominal bore tube light gread GI laid under road/culvert/drain fixed to pole wall with help of flat iron clamps etc for cable protection for complete all as specified and as directed. |
| 20 | M&L for cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area, electric power cable grade with stranded aluminium conductor of size 10 Sqmm, 4 core coplete with thimbles and slives on end termination. Note:- Unserviceable cable shall be deposit in MES Yard. |
| 21 | - ditto- all as per item No.19 above but 10 sqmm, 2 core. |
| 22 | - ditto- all as per item No.19 above but 16 sqmm, 4 core. |
| 23 | - ditto- all as per item No.19 above but 25 Sqmm 3.5 core. |
| 24 | - ditto- all as per item No.19 above but 50 Sqmm 3.5 core. |
| 25 | - ditto- all as per item No.19 above but 95 Sqmm 3.5 core. |
| 26 | - ditto- all as per item No.19 above but 120 Sqmm 3.5 core. |
| 27 | - ditto- all as per item No.19 above but 150 Sqmm 3.5 core. |
| 28 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation of poles/ stays/ laying of cables etc and getting out including trimming of sides of trenches complete all as specified and directed. |
| 29 | Returning, filling the soft / loose soil including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and directed. |
| 30 | Removing of surplus excavated soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 31 | M&L for sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed. |
| 32 | M&L for brick protection using old size sub class ‘B’ bricks, laid flat, dry adjacent to each other laid length wise perpendicular to the axis of cable complete all as specified and directed. |
| 33 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected using galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. |
| 34 | Supply, install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65 , Outdoor type confirming to IS-61439 factory fabricated prewired made out of 3.15 mm thick CRCA sheet outer & 2 mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/outgoing MCCB ad TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision of termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The plateform of LT Panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400 mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM 1:3 and PCC copping (1:2:4) not less than 50 mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-Charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene Adhesive type gasket shall be used to make panel vermin proof and comprising of following :- (Sub Main LT Panel) |
| 35 | INCOMING:- MCCB 4 Pole, 250 Amps ,415 Volt of breaking capacity 36 KA with Ics=100%Icu Adjustable thermal and adjustable magnetic release - 01 Nos.BUSBAR:- TPN 375 A - 01 Sets.OUTGOING:- MCCB 4 pole 415 V 160 Amps 35 KA, with Ics=100%Icu Adjustable thermal and adjustable magnetic release - 01 nosMCCB 4 pole 415 V 63 Amps 25 KA, TM release - 04 nosMCB SPN, 240 V, 6-32 Amps -02 NosVoltmeter (0-500) V digital type with selector switch.-01 No, Astro timer switch with auto ON/Off to street lights including TPN MCBAmpere Meter (0-500) Amperes, 96mm square, digital type, CT connected with suitable CTs and selector switch-)1 No, RYB Phase indicator, LED type each Set |
| 36 | - ditto- all as per item No.33 above but comprising of following :- (Sub Main LT Panel)INCOMING:- MCCB 4 Pole, 160 Amps ,415 Volt of breaking capacity 36 KA with Ics=100%Icu Adjustable thermal and adjustable magnetic release - 01 Nos.BUSBAR:- TPN 250 A - 01 Sets.OUTGOING:- MCCB 4 pole 415 V 25-100 Amps 36 KA, with Ics=100%Icu Adjustable thermal and adjustable magnetic release - 04 nosMCCB 4 pole 415 V 63 Amps 25 KA, TM release - 04 nosMCB SPN, 240 V, 6-32 Amps -02 NosVoltmeter (0-500) V digital type with selector switch.-01 No, Astro timer switch with auto ON/Off to street lights including TPN MCBAmpere Meter (0-500) Amperes, PF meter, digital type, CT connected with suitable CTs and selector switch-)1 No, RYB Phase indicator, LED type each Set |
| 37 | - ditto- all as per item No.33 above but comprising of following :- (Sub Main LT Panel)INCOMING:- MCCB 4 Pole, 100 Amps ,415 Volt of breaking capacity 16 KA with Ics=100%Icu Adjustable thermal and adjustable magnetic release - 01 Nos.BUSBAR:- TPN 150 A - 01 Sets.OUTGOING:- MCCB 4 pole 415 V 25-100 Amps 36 KA, with Ics=100%Icu Adjustable thermal and adjustable magnetic release - 04 nosMCB SPN, 240 V, 6-32 Amps -03 NosVoltmeter (0-500) V digital type with selector switch.-01 No, Astro timer switch with auto ON/Off to street lights including TPN MCBAmpere Meter (0-500) Amperes, 96mm square, digital type, CT connected with suitable CTs and selector switch-)1 No, RYB Phase indicator, LED type each Set |
| 38 | - ditto- all as per item No.33 above but comprising of following :- (Bus Bar Panel)3BUSBAR:- TPN 250 A - 01 Sets.Digital Multi function meter connected with suitable CTs and selector switch-1 No, Phase indicator RYB LED type - 1 Set |
| 39 | Dismantling of PCC pole with foundation of any size |
| 40 | Supply and install hot dip galvanized steel (IS 5986 Gr. Fe 510) Octagonal pole model NJOP 7 of 7.0 mtr long, top top die 70 mm botom dia 130 mm having thickness 3 mm having door operating of size 500 mm above ground level with CI Base plate of size 220x12mm having PCD 205 mm foundation J bolts length 700 mm nuts and screwes, No's of bolts 4 x 20 and having hot dip galvanized single plain arm bracket 1000 mm overhang on one side with 48.3 mm outer dia pipe of thickness 3.2 mm fixed on top with bolts and necessary earth work RCC/PCC work for the foundation of pole, including necessary form work and fare finish to exposed surfaces without using extra cement etc; complete all as specified and directed. |
| 41 | S&F of junction box factory made weather proof size 250mmx200mmx100mm made of 16 gauge steel sheet powder coated inculded 25mmx6mm aluminium TPN bus bars & 01 MCB 10 Amps for controlled one No's of LED Lights complete all as specifed and directred |
| 42 | Supply & Laying of telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene including coupler and bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and directed.. |
| 43 | S&F of decorative LED post top lantern 20 watt powder coated aluminium die cast and spun aluminium body with clear/opel diffuser suitable for landscape lighting available in 5700K CCT IP65 input voltage from 120-270 V power factor above 0.95 complete fitting including PCC platform MS column pipe 1.50 Mtr length, all accessories all as specified and directed. |
| 44 | S&F of LED decorative bollard garden lights suitable for 10 watt IP65 10-15 watt in inverted pyramid tropod type LED bollard with soft 360 light, resistant to corrosion with better optic for uniform distribution complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and as directed. |
| 45 | M&L for PCC 1:2:4 type B2 using 20mm graded for padestal coping including necessary formwork finished fair using extra cement complete all as specified and as directed. |
| 46 | M&L for sub main wiring with FRLS PVC insulated. 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications with 3 runs of 2.5 sqmm single core multistranded copper conductor FRLS PVC insulated cable as earth continuity conductor drawn through & including PVC conduit of 20mm dia. size and conduit accessories concealed in wall connecting to common earth dolly all as specified and directed. Note:- (i) Three runs of cable and one run of conduit with necessary accessories will be measured as one unit length. (ii) The wiring shall be done in proper colour coding using red, yellow or blue for phase, black for neutral and green for earth leads. |
| 47 | Supply & installation of hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minium 5 star rating and EER 3.2 of capacity 1.5 Ton, complete all as specified and directed. |
| 48 | M&L for sub main wiring with two runs of single core PVC insulated FRLSH, unsheathed copper condutor, multi stranded cable of size 4.00 Sqmm 1100 volts grade drawn PVC surface conduit of size 19/20 mm (ISI marked) including PVC accessories complete including cutting and chasing and making good etc; including one run of 4.0 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed. Note:- Two run of 4.0 Sqmm cable one run of 2.50 Sqmm cable as earth continuity conductor and one run of PVC conduit shall be measured & paid as one unit.) |
| 49 | S&F of voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stablized at 230 volt with accuracy +2.5 % and capacity 5KVA copper wound. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender