Tender For Provision Of Holiday Home At Birchgunj, Military Station, Port Blair
Tender Value
22 Crore
Estimated cost
Bid Submission
17 Sep 2026
25 days left
EMD
14.25 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Holiday Home At Birchgunj, Military Station, Port Blair
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE ‘A’ PART-I(BUILDING/ STRUCTURE)Details of prepriced schedule is given in tender documents. |
| 2 | SCHEDULE \\"A\\" PART-II (EXCAVATION, EARTHWORK, SITE CLEARANCE & LAND DEVELOPMENT) Details of prepriced Schedule is given in tender documents. |
| 3 | SCHEDULE \\"A\\" PART-III (INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. |
| 4 | SCHEDULE \\"A\\" PART-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. |
| 5 | SCHEDULE \\"A\\" PART-V (EXTERNAL WATER SUPPLY )Details of prepriced Schedule is given in tender documents. |
| 6 | SCHEDULE \\"A\\" PART-VI (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents. |
| 7 | SCHEDULE \\"A\\" PART-VII (ROAD/ PATH/ CULVERT) Details of prepriced Schedule is given in tender documents. |
| 8 | SCHEDULE \\"A\\" PART-VIII (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents. |
| 9 | SCHEDULE \\"A\\" PART-IX (AREA DRAINAGE)Details of prepriced Schedule is given in tender documents. |
| 10 | SCHEDULE \\"A\\" PART-X (RCC RETAINING WALL)Details of prepriced Schedule is given in tender documents. |
| 11 | SCHEDULE \\"A\\" PART-XI (COMPOUND WALL/FENCING/GATE)Details of prepriced Schedule is given in tender documents. |
| 12 | SCHEDULE \\"A\\" PART-XII (AIR CONDITIONING)Details of prepriced Schedule is given in tender documents. |
| 13 | SCHEDULE \\"A\\" PART-XIII (HOT/COLD WATER SUPPLY)Details of prepriced Schedule is given in tender documents. |
| 14 | SCHEDULE \\"A\\" PART-XIV (RAIN WATER HARVESTING) Details of prepriced Schedule is given in tender documents. |
| 15 | SCHEDULE \\"A\\" PART-XV (DG SET) Details of prepriced Schedule is given in tender documents. |
| 16 | SCHEDULE \\"A\\" PART -XVI (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' E ' signifies this fact only. |
| 17 | Supply, Install Testing and commissioning of Monoblock Centrifugal pump set horizontal type suction / delivery with a discharge capacity-22LPS, with Max Head 22 mtr head,Suction size 80 x80 mm with mechanical seal arrangement including 3-phase energy efficient squirrel cage induction motor as prime mover, 415 V, S1 duty rating, energy efficiency level -IE 3 BEE star rated, ISI Marked 5HP (3.7 KW) 2900-3000 RPM as per IS- 12615 ( latest edition) fixed to pump through jaw type coupling with pump impellor of phosphorous bronze and shaft of carbon steel complete, including PCC foundation, base frame and cable connection complete all as specified and as directed. NOTE:- The work includes 5 run 4 sqmm FRLS copper cable from starter panel to pump set connection terminal. |
| 18 | Supply and fix Foot valve Brass body flanged suitable for 80 mm bore GI pipe connection all as specified and directed. |
| 19 | Supply, installing, testing and commissioning factory made and tested LT Motor control panel suitable for 5 HP motors -02 Nos Outdoor type floor mounted with suitable size of MS angle support frame, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. hall be dust and vermin proof, protection class (IP-42) and made of 3.15 mm thick CRCA Sheet front and Rear opening type with space for cable entry , with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 2.5 sqmm complete all as specified and directed. Make:- Any C.P.R.I ApprovedThe scope of work also comprising of the following:- |
| 20 | BUS BAR CHAMBER :- (a) 100 Amp 4 Strips, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER :- (a) Digital Volt Meter, 96X96mm, flush type rated 0-500 V, with Volt meter selector switch- 01 Set. (b) C.T's 100/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)(c) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(d) Protection MCB 6 A SP C Series- 1 Set. (Set of three). INCOMING SUPPLY :- (a) MCCB 40 Amps 16 KA , 4 Pole, adjustable thermal & magnetic release 415 volts , 50Hz,=01 No., OUTGOINGS :- 1. Star Delta Starter for rating 5 HP -02 NosNote : Each Motor starter shall have the following suitable for 5 HP motor(a) MCB TPN 20A (b) Power Contactor TP (Main & Delta) (c) Power Contactor TP (Star) (d) Bi Metal Over Load relay (e) Star delta timer Micon Series(f) Digital Amp Meter (g) CT (h) Single Phase Preventer(i) Push button Start/Stop with Elements(set of 2) (j) On, Off, Trip indicating Lights LED type 220 V AC(k) Aux. Blocks 1 No+1 Nc 2. MCB SPN, 32 Amps 415v, 10 KA - 01 Nos. |
| 21 | Construction of valve chamber of following sizes with precast solid block masonry set in CM 1:4 in wall and 15 cm thick hard core, 200 mm thick PCC stone masonry work grade D5 built in CM (1:6) 15 mm thick internal and external plaster CM (1:4) 10 SWG thick MS sheet cover including 40x4ox6 mm MS angle frame fixed in coping in PCC (1:2:4) type B1 with locking arrangement and painting with one coat of red oxide and two coat of black bituminous paint complete all as specified, shown on drawing and as directed of following (internal) dimension (a) 600mm x 600mm x 750mm all as specified and directed. |
| 22 | M & L for Cutting of existing DI pipe line of size 100 mm dia and insertion of DI fitting Tee Reducer100 x 100 x 80 mm with flange for taking branch connection of 80 mm GI pipe include necessary fittings complete all as specified and directed. |
| 23 | Supplying, installation, testing and commissioning of 11 KV, 630 Amps SF6 insulated 1 way Ring main unit(RMU) Outgoing VCB, (suitable for connecting direct Bus to Bus coupling with existing 3 way RMU extensible type Siemens make on ground) having short circuit capacity 21kA/3-sec, The HV switchgear and control gear should be confirming to IEC-62271-1, 100, 200. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFLR classification for gas tank & cable box. The complete RMU front along cable chamber to be covered by an seperate outdoor to have ingress protection of minimum IP54.The RMU shall be electrical and mechanically interclocked, comprising Fully motorized operated Spring-charging VCB electrolytic grade copper busbars all inside single, gas-filled, robotically welded stainless steel tank with min. thickness 2.5 mm, IP 65 Degree of Protection, on-site-repairable with site replacable bushing/coupling/mechanism, gas refilling etc. The RMU Unit alongwith Bus connected, fixed-type shall include the following along with all necessary accessories and fittings as required at site. complete all specified and directed. Please Enable Macros to View BoQ information |
| 24 | Supplying, installation, testing and commissioning of 11 KV, 630 Amps SF6 insulated 1 way Ring main unit(RMU) Outgoing VCB, (suitable for connecting direct Bus to Bus coupling with existing 3 way RMU extensible type Siemens make on ground) having short circuit capacity 21kA/3-sec, The HV switchgear and control gear should be confirming to IEC-62271-1, 100, 200. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFLR classification for gas tank & cable box. The complete RMU front along cable chamber to be covered by an seperate outdoor to have ingress protection of minimum IP54.The RMU shall be electrical and mechanically interclocked, comprising Fully motorized operated Spring-charging VCB electrolytic grade copper busbars all inside single, gas-filled, robotically welded stainless steel tank with min. thickness 2.5 mm, IP 65 Degree of Protection, on-site-repairable with site replacable bushing/coupling/mechanism, gas refilling etc. The RMU Unit alongwith Bus connected, fixed-type shall include the following along with all necessary accessories and fittings as required at site. complete all specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 25 daysSep 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender