Tender For Provn Of Toilet/ Bathroom Post Near Bldg No T-62 (Hq Sqn Or Line) Under Age B/R-Ii, 25 X Geyses For Jcos And Or Bathroom (Bldg No T-312Bc, T-313Bc, P-6 & P-49, 20 X Desert Cooler For Bldg No T-05, T-06, T-08 & T-09 At Otm Accn And 80 X Cei
Tender Overview
Project Description
Tender for Provn Of Toilet/ Bathroom Post Near Bldg No T-62 (Hq Sqn Or Line) Under Age B/R-Ii, 25 X Geyses For Jcos And Or Bathroom (Bldg No T-312Bc, T-313Bc, P-6 & P-49, 20 X Desert Cooler For Bldg No T-05, T-06, T-08 & T-09 At Otm Accn And 80 X Ceiling Fan For Jcos Living, Trg Cell And Or Line Under Age E/M-I & Age E/M-Ii Of Ge (N) Mamun
BOQ
| Sl. No. | Item Description |
| 1 | Surface Excavation n exc 30cm deep and averaging 15cm deep and getting out in any type soil, complete all as specified and directed. |
| 2 | Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in any type soil, complete all as specified and directed. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. |
| 4 | Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 5 | 5mm thick rendering on concrete surface of ceiling, chajja etc. in CM 1:3 finishing the surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 6 | 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 7 | 15mm thick cement plaster on fair faces of brick masonary/ concrete/ wall surfaces in CM 1:4 finished the surface even and smooth without using extra cement including mixing of water proofing compound, complete all as specified and directed. |
| 8 | M&L for rendering 10mm thick in CM 1:3 in fascia / edging / ceiling of Chajjas, roof projections etc, making surface in true line, true shape and finishing the surface smooth without using extra cement complete all as specified and directed. |
| 9 | PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified. |
| 10 | RCC M-25 (Design mix) as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns and basement slabs and the like, complete all as specified and directed |
| 11 | RCC M-25 (Design mix) 20mm graded aggregate as in columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 12 | RCC M-25 (Design mix) 20mm graded aggregate as in beams, cantilever, bressummers, lintels over 1.50m span complete all as specified and directed. |
| 13 | RCC M-25 (Design mix) 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed |
| 14 | RCC 1:1.5:3 type A-1 (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork, complete all as specified and directed. |
| 15 | M&L for precast RCC 1:2:4 Type B-1 (using 20 mm graded crushed stone aggregate) as in manhole/drain covers reinforced with steel bars, complete all as specified & directed. |
| 16 | M&L for PCC type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair including making joints not more than 2.5 m (or as directed) and at corner, filled with bitumen 85/25 and sand in ratio 1:2 by weight complete all as specified and directed. |
| 17 | M&L for PCC 1:2:4 Type B1 (using 20 mm graded crushed stone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, benching, copings, kneelers, apex stones, bed plates, kerbs , fillet, gola, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed |
| 18 | M&L for PCC 1:2:4 Type C-1 (using 20 mm graded crushed stone aggregate) as in copings, apex stones, bed plates including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed |
| 19 | M&L cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in surface channel, drains/ manhole bed, finished even and smooth using extra cement complete all as specified and directed |
| 20 | M&L for lean concrete type C-2 1:3:6 (40mm graded crushed stone aggregate) as in sub floors, sub bases, floors and pavings etc complete all as specified and directed. |
| 21 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, including flat rough finished surafaces of concrete complete all as specified and directed. |
| 22 | Formwork to sides and soffits of floor or roof beams, haunching, lintels, cantilevers shelved including supports overhangs etc. also splays between floors and beams, etc., finishing the concrete surfaces rough, complete all as specified and directed. |
| 23 | Formwork to sides of pillars, posts, struts, piers, columns, and stanchions, square, rectangular or polygonal in shape, including flat rough finished surafaces of concrete complete all as specified and directed. |
| 24 | Formwork to sides and soffits of suspended slab such as roof slab, floor slab, shelves and similar works n. exc. 200mm thick (Horizontal or sloping), finishing the concrete surfaces rough, complete all as specified and directed. |
| 25 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors & roofs n exc 20cm wide & sides of RCC/PCC bands in walls, horizontal or sloping, & similar work exc 10cm but exc 20cm wide, rough finished surfaces of concrete, complete all as specified and directed |
| 26 | MS TMT bars 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed. |
| 27 | MS TMT bars 8mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed. |
| 28 | MS TMT bars bars 5mm dia and over as in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed. |
| 29 | Box type Steel windows and ventilators comprised of tubular frame and shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks (1:2:4 type 12.50mm graded crushed stone aggregate) including two coats of synthetic enamel paint over a shop coat of red oxide primer etc. all as shown on drg No CEPZ /TD-354/09 sheet 1/3 to 3/3 and making good to disturbed area in same finish, complete all as specified and directed. |
| 30 | Factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter with CNC cutting of 35mm size prefinished with UV coating comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately). |
| 31 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat prefinished with UV coating of size 45x70 mm (duble rebate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/ moisture proof and fire retardant, fixed in position with and including MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note: (i) For WPC solid door/window frames minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. (ii) Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed. |
| 32 | S&F 250 mm long SS sliding door bolt (ISI Marked), plate type, stove enameled black, with bright bolt not less than 12 mm dia and incl a minimum of 6 bolts & nuts, four on bolts plates and two on staple plate or extruded section and fixing bolts and sliding bolts, complete all as specified and directed |
| 33 | 150mm long, SS barrel tower bolts of extruded section, complete all as specified and directed. |
| 34 | 150mm long, extruded SS handles, fabricated type, anodised, complete all as specified and directed. |
| 35 | S&F Stainless steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks, or galvanized wire staples complete all as specified & directed. |
| 36 | 3mm thick sheet glass ordinary quality, and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed. |
| 37 | Glazed ceramic coloured tiles 600mm x 300mm x 7-8mm thick as in vertical surfaces such as skirting, dado etc set and jointed joint free in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed. |
| 38 | Non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed (joint free) in neat cement slurry and pointed in coloured cement over 15mm thick screed bed or bedding layer of mortar in CM 1:6, complete all as specified and directed. |
| 39 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 40 | M&L for green marble work 15-17 mm thick (table rubbed and polished) for wash basin platform including hole where required etc in cement mortar (1:4), pointed in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of including roughening of old concrete of Bhaislana Zebra, complete all as specified and directed. |
| 41 | M&L for Round chamfering to the edges of marble/granite slabs complete all as specified and directed. |
| 42 | 15mm bore bib tap, fancy type long body chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,complete all as specified and directed. |
| 43 | S&F 15mm bore dia angle valve / stop valve cast copper alloy capston head chromium plated (as per sample), fancy type ISI marked with crutch or butter fly handles screwed down, screwed for iron pipe complete all as specified and directed. |
| 44 | S&F 15mm bore dia concealed type angle valve / stop valve (as per sample) cast copper alloy chromium plated fancy type with long shank and cup ISI marked with crutch or butter fly handles screwed down,screwed for iron pipe of 15mm bore complete all as specified and directed. |
| 45 | S&F 20-25mm bore dia gun metal globe or gate valves (as per sample) cast copper alloy chromium plated fancy type, ISI marked with crutch or butter fly handleswith iron wheel head, screwed both ends for iron pipe and fixed including dismantling of old unserviceable existing valve, complete all as specified and directed |
| 46 | 15mm bore pillar tap, copper alloy with capstan head, chromium plated screwed down high pressure, with or without lettered hot/cold with long screwed shanks and fly nuts screwed for iron pipe (fixed in repairs), complete all as specified and directed. |
| 47 | S&F vitreous china ware oval counter type wash hand basin of size 560mmx470mmx190mm including 32mm full threaded waste coupling and 32mm PVC waste pipe fixing, complete all as specified and directed. |
| 48 | S&F vitreous china squatting pan water closet, orissa pattern, size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, front or back inlet and foot rests, any pattern including making good to floor, complete all as specified and directed. |
| 49 | S&F Vitreous china wash down water closet pan pedestal pattern, white (excluding supply of flushing cistern and flush pipes, but including fixing thereof), including making connections to trap, and to flush pipe including plastic seat and cover with stainless steel or aluminised hinging device, complete all as specified and directed. |
| 50 | S&F PVC low level flushing cistern 10 ltr capacity, inlet and outlet connections, brackets, PVC flush pipe with bend 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to WC complete all as specified and directed. |
| 51 | Health faucet mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, fixed in repair, complete in all respect as specified and directed. |
| 52 | S&F towel rail, brass, CP 600 mm long 20mm dia pipe of 1mm thick complete all as specified and directed. |
| 53 | S&F over head shower rose 125mm size (square/circular as per sample) for 15mm bore pipe, cast copper alloy Chromium plated complete all as specified & directed. |
| 54 | PVC connection 15mm size with PTMT nuts at both ends of length 450mm for hot and cold water, fixed in repair, complete all as specified and directed. |
| 55 | Steel water tubing, 15mm bore, galvanised, \\"medium grade\\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, trenches (Also for water supply to desert coolers) etc, complete all as specified and directed |
| 56 | Steel water tubing, 20mm bore, galvanised, \\"medium grade\\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, trenches complete all as specified and directed. |
| 57 | 110mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints in trenches, complete all as specified and directed. |
| 58 | 75mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints laid in trenches including clamps, complete all as specified and directed. |
| 59 | 75mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints,fixed to walls including clamps, complete all as specified and directed. |
| 60 | S&F PVC (SWR) 110mm bore bends any radius, complete all as specified and directed. |
| 61 | S&F PVC (SWR) 75mm bore bends any radius, complete all as specified and directed. |
| 62 | S&F PVC (SWR) 75mm vent cowl, complete all as specified and directed. |
| 63 | S&F 110mm bore dia PVC (SWR) branch piece, double (double Y) equal or unequal or with parrallel, complete all as specified and directed. |
| 64 | S&F 75mm bore dia PVC (SWR) branch piece, single (single Y) equal or unequal or with parrallel, complete all as specified and directed. |
| 65 | S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm bore, complete all as specified and directed. |
| 66 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and directed. |
| 67 | S&F for cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles, complete all as specified and directed |
| 68 | Concrete bed to 200mm drain pipes including packing under and haunching against the sides of pipes after they are laid and tested; in cement conctrete type C-2, 1:3:6, using 40 mm graded crushed stone aggregate, complete all as specified & directed. |
| 69 | Concrete bed to 150mm drain pipes including packing under and haunching against the sides of pipes after they are laid and tested; in cement conctrete type C-2, 1:3:6, using 40 mm graded crushed stone aggregate, complete all as specified & directed. |
| 70 | 200mm bore reinforced cement concrete pipes, class NP3, laid and jointed complete with one collar per length of pipe, complete all as specified & directed. |
| 71 | 150mm bore reinforced cement concrete pipes, class NP3, laid and jointed complete with one collar per length of pipe, complete all as specified & directed. |
| 72 | 40mm thick sand filling under floors in layers n exc 25mm thick including watering and consolidation, complete all as specified and directed. |
| 73 | 60mm thick factory made machine pressed precast concrete, coloured interlocking paver block with cement and coloured pigment (topping thickness not less than 5mm thick with white cement and non-fadable epoxy coated colour pigment), any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006, M-35 grade, complete all as specified and directed. |
| 74 | 20mm thick cement plaster in cement mortar 1:4 on concrete surfaces, finished even and smooth using WPC liquid as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement, complete all as specified & directed |
| 75 | Preparation of surfaces and applying first coat of fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflective Index (SRI) of 100-110, having minimum elongation of 300%, tensile strength of 2.9 Mpa and shall have cracks bridging ability upto 2.5mm and shåll resist 10 bars of hydrostatic pressure & reduce surface temperature upto 10 degree Celsius with 33% dilution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 gsm/sqm and pasting it properly with overlap of 50mm and allow it to dry, applying second of undiluted coat @ 0.45 Itr/sqm. Applying third and final coat undiluted @ 0.45 ltr/sqm complete application to be done by the manufacturer or authorised applicator, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 76 | Preparation of surfaces and applying first coat of fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflective Index (SRI) of 100-110, having minimum elongation of 300%, tensile strength of 2.9 Mpa and shall have cracks bridging ability upto 2.5mm and shåll resist 10 bars of hydrostatic pressure & reduce surface temperature upto 10 degree Celsius with 33% dilution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 gsm/sqm and pasting it properly with overlap of 50mm and allow it to dry, applying second of undiluted coat @ 0.45 Itr/sqm. Applying third and final coat undiluted @ 0.45 ltr/sqm complete application to be done by the manufacturer or authorised applicator, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender