Civil Mechanical, Electrical, & Other Works At Retail Outlets In Maharashtra2 State For Period 2026-2029.
Tender Overview
Project Description
Civil Mechanical, Electrical, & Other Works At Retail Outlets In Maharashtra2 State For Period 2026-2029.-11 7006210 Canopy . Falseceiling 150/200F False Ceilingscopethe Scope Of This Specification Covers The Design, Manufacture, Prefabrication, Transportation, Installation And Commissioning Of The Complete False Ceiling System. However, All Items Required For The Safe And Efficient Maintenance Of The False Ceiling.A. Materials Of Panel :A. 1 : Cold Rolled Steel Confirming To Is 513 Having Yield Strength Of 240 Mpa (Minimum).A. 2 : Base Metal Thickness Should Not Be Less Than 0.55 Mm.B. Design Criteria :B 1 : Ceiling System To Be Designed To Withstand Wind Velocity Of 220 Kmph And Relevant Seismic Factor To The Specific Location Where The False Ceiling Is To Be Installed Or Wind Load As Per Is 875 Part Iii Whichever Is Higher.B 2 : System To Be Has To Be Designed As Fixed System In Which False Ceiling Panels Are Fixed To The False Ceiling Runner ( Already Supplied With Canopy ) By Suitable Designed Gi Clips Or Carrier. One End Of The Clip Or Carrier Is Fixed To The False Ceiling Runners By The Bolt Of Suitable Design And Other End Of The Clip Or Carrier Is Designed To Hold Interlocking Ends Of The Ceiling Panels. Incase Of Carrier The Cut Outs Hold The Panels Should Be Suitably Designed Taking Into Consideration Of The Material/ Pressure Created By Air Inside The False Ceiling.B 3 : The Flashing, Capping And Trims Shall Be Manufactured From The Same Materials And Colour As The Ceiling Materials. These Are Fixed With Aluminium Rivets Or Stainless Steel Pins.B 4 : Maximum Deflection Of Sheets (Panels) Is Limited To L/325 Maximum As Per Is 800 Deflection Criteria.C. Panel Specifications :C 1 : Rolled Formed Ceiling Panels Of 150 F/ 200 F Including Suitable Design Of Tongue And Groove Interlocking Should Be Coated With Zinc In A Minimum Thickness Of 175 Gsm On Both Side. The Panel Should Be Finished With 15 To 18 Micron Polyester Top Coat 10 Micron Thickness. The Total Coated Thickness (Tct) Should Not Be Less Than 0.6 Mm. Colour Of The Panel Shall Be White Matt Finish.Note :Supplier Has To Visit The Site Before Supply Of Materials At Site And Get Familiariesed With The Wind Velocity, Seismic (Earthquake) Factor And Accordingly Design Of False Ceiling To Be Done And Submit The Design Calculation And Drawing Details To Bpcl. After Completion Of Work, Supplier Has To Submit Warranty Certificate From Manufacturer Of Panels To Bpcl. 21 7008247 Bldg Porta Cabins . Porta Cabins Fabricating Supply And Installation Of Porta Cabins As Per Drawings The Following Details Are Being Specified For Reference Purpose And To Be Followed On Development Of Portable Cabin. However, Bpcl Reserves The Right To Effect The Minor Changes As Per Site Requirement And Availability Of Material. The Contractor Is Requested To Understand All Details On The Construction Material As Well As Arrange To Get The Porta Cabin Inspected During Fabrication And Also On Completion.1. Shell : The Shell Will Be Fabricated From Quality Steel Duly Welded, Comprising Of Base Frame, Peripheral Structure And Self Draining Roof. One Entry Door And 3Windows. The Eight Corners Are Sufficiently Strengthened To Facilitate Transportation, Lifting And Placing.2. Base Frame : The Base Frame Is Made Of Pressed Mild Steel Channel Section. The Main Structural Element Having 150 Mm X 75 Mm I Beam And Cross Members Are Of Ismc 75 #C# Channels.3. Side And End Walls : The Side And End Frame Is Made Out Of Mild Steel Pressed Sections Of Suitable Profiles / Pillars Of Suitable Strength.4. Flooring Systems : On The Bottom Frame 19 Mm Thick Marine Plywood, Of Approved Quality Is Fixed By Means Of Self Tapping Screw. Pvc Vinyl Sheets Are Fixed On This For Floor Covering. 5. Roof : Self Draining Type Rood Is Made Out Of 1.6Mm Thick Ms Sheet, Adequate Roof Bows Are Provided. Roof Is Adequately Chambered For Draining Of Rain Water.6. Insulation : 50 Mm Thick Glass Wool/Rock Wool/ Puf / Thermo Cole Is Used For Walls And 75 Mm Thick Insulation Material Is Used For Roof.7. Inner Paneling : The Interior Will Be Aesthetically Finished So As To Give Custom Built Appearance With Extremely High Quality Workmanship.8. Windows : The Provision Of 2 No. Window Having The Size Of 3# X 3# With Aluminum Grills On All Windows. The Window / Door Will Also Have Sunshade For Protection Against Rain / Sun.9. The Provision Of 1 No Door Having The Size 1Mtr X 2Mtr On Front Side Of The Porta Cabin, Opening On Outer Side. 10. Electrical : The Provision Of Following Points Will Be Made:1 No. Junctin Box On Outer Side.2 Nos Internal Junction Boxes2 Tube Light Points2 Nos Wall Fan Points2 Nos Security Lighting On Outer Side2 Nos Tube Light Points On The Outer Side (Under Small Shed On Entry)2 Nos Telephone Line Jacks With Cabling For 2 Lines11. The Color Scheme Will Be White/ Off White/ Approved12. All Other Items Not Covered Above Will Be Of Standard Quality And As Approved By Engineer In-Charge. 23 7006211 Canopy . Metacolor Roofing Trapezoidal Supplying And Fixing 0.5Mm Thick Meta Colour/Poly Steel Sheet With Necessary Poly Propelene Washers Self Trapping Screws Etc Complete Upto A Maximum Of 15M2 Trapezoidal Profile 24 9021399 Rvm . . Stickers -Vinyl Supplying And Fixing Of Self Adhesive Vinyl Stickers Of 3M-Ij1110/Lg-Hi-Cal-Lc2199 Make With Ecosolvent Digital Printing For Explosive Licence No, Complaints /Suggestions Message, Neighborhood Assistance Etc., As Per Std Design, Size And Specifications. Life Of Vinyl Should Be Minimum 24 Months 31 9038456 S/I Volt Stabilizer Supply And Installation Of 30 Kva 3 Phase Servo Stabilizer With Input Voltage : 242 - 502 V Line To Line, 140 To 290 V Line To Neutral Output : 30 Kva (10 Kva Load Per Phase) Output Voltage : 400Vac Nominal 3Phase For Detailed Technical Specification Refer Stabilizer Specification Attached In Sor Tender. 33 9038457 S/I Ups 3Kva W. Batt Supply And Installatuion Of True On-Line, Igbt Based, Microprocessor Controlled Double Conversion Technology With 2.4 Kvah Sealed Maintenance Free Lead Acid Battery For 30Mins Backup. Input Voltage : 160 - 280 V, Single Phase Output Voltage : 230V, Single Phase ± 1% For Detailed Technical Specification Refer Ups Specification Attached In Sor Tender. 72 7006595 Electrical Earth Mf Electrode <3.5M Providing Earthing Station Using Maintenance Free Electrode Of Ashlok Or Equivalent Make Including Filling Material, Electrode And Labour Complete. Upto A Depth Of 3.5M 74 9021373 Light Fix . Sup Led Flood Light 50W Supplying Of The Following Types Of Industrial/Flameproof Light Fittings With Tubes/Lamps; Control Gear; Mounting Accessories; Reflectors; Acrylic/ Glass Covers. This Also Includes Supply Of Tubelights Cu Ballast And Pf Capacitor.All Flameproof Light Fittings Shall Be Cmri/Peso Valid Certificates. Supply And Installation Of 50W Led Hoarding Flood Light Along With Black Colored Powder Coated Ms Pipe Of Size 20-25Mm Complete Of Cromption Greaves, Havells, Philips Or Equivalent. 82 7007288 Dway . Paver Bl 80 Mm Tk Road Work Supplying <(>&<)> Laying Cc Paver Blocks 80Mm Thick Using Minimum M 35 Grade Laid On 50Mm Avg Thickness Sand Bedding Maximum Quantity To Be Restricted To 100 Sqm) Paver Blocks To Be Procured From Bpcl Approved Manufacturers. 92 9021400 Rvm . . Pump Graphics -Vivyl Supplying And Fixing Of Self Adhesive Vinyl Stickers Of 3M-Ij1110 Make With Ecosolvent Digital Printing With Lamination For Product Stickers, Mpd Graphics Including Removing Old Vinyl Etc., As Per Std Design, Size And Specifications. Life Of Vinyl Should Be Minimum 24 Months 96 9002446 Rvm . Sup N Fix Perf. Vinyl Sticker Supply N Fixing Of Perforated Vinyl Sticker On Glass Of Sales Room Of Approved Quality By Engg Incharge With Art Work Etc Complete 107 7008365 Automation . . Thermal Paper 57Mm Supply Of Thermal Paper Of 57 Mm Width As Per Specifications 17 Mtr Roll 152 7007031 Pipe . Teflon Sheet Packing 50 Nb Dia Pipelines And Fittings: Teflon Sheet Packing For Flange Joints. 50 Nb Dia. 186 7007032 Pipe . Teflon Sheet Packing 80 Nb Dia Pipelines And Fittings: Teflon Sheet Packing For Flange Joints. 80 Nb Dia. 346 9037447 Sample Boxes 1.2 L . . . Supply Of Aluminium Sample Boxes With Wooden Box And Locking Arrangement. - 1.2 L Sample Storage 719 9022073 . . . Fire Ext 9 Kg Dcp Supplying; Providing And Fixing Fire Extinguisher Of Approved Make; Dcp Type 9 Kg. Capacity Conforming To Is 2171 Each These Shall Be Fixed On Walls. 745 9037522 100 W Led Canopy Lig Supply & Fixing Of 100 W Led Approved Make Under Canopy Light Fixture With Lights 810 9038511 Ele Audit Pngrb <100 Electrical Audit As Per Pngrb Guidlines Of Ro With Total Sale Less Than 100 Kl/Month. Detailed Scope Of Work Attached In Sor Tender. 812 9037518 Ground Water Test-Ro Ground Water Quality Monitoring At Ros Sites Located Within 100M From Nearest Point Of Surface Water Bodies Per Cpcb Norms 821 9038515 Ele Au Pngrb 100-300 Electrical Audit As Per Pngrb Guidlines Of Ro With Total Sale 101 To 300 Kl/Month. Detailed Scope Of Work Attached In Sor Tender. 825 9009935 Sup N Inst 4.5 Kg Co2 Type Supply, Installation, Testing And Commissioning Of 4.5Kg Capacity Isi Marked (Is-2878) Carbon Di-Oxide Type Flat Base Fire Extinguishers, Including Valve, 1 Meter Long Discharge Hose Of Not Less Than 10Mm Dia ,Complete In All Respects, Including Initial Fill With Co2 Gas Conforming To Is:307-1966 And With Wall Suspension Brackets(Fixed With Anchor Fastner) With Approved Fixed Signage As Per Code. 832 7006194 Borewell . . Electrologging Test Bore Well Carrying Out Electrologging For Determining The Exact Location Of Saline Zone Etc. Complete 836 9038512 Ele Audit Pngrb >300 Electrical Audit As Per Pngrb Guidelines Of Ro With Total Sale More Than 300 Kl/Month Detailed Scope Of Work Attached In Sor Tender. 841 9038462 S/F Hard Drive 4Tb Providing, Installing N Commissioning Ups Of Approved Make.With Over/ Under Load Protection Complete, With Led Acid Battery. 4Tb –Surveillance Hard Drive (Storage .To Match Nvr Requirment ) 842 9038464 S/F Ir Bullrt Cam Providing, Installing N Commissioning Ups Of Approved Make.With Over/ Under Load Protection Complete, With Led Acid Battery. Ir Bullet Camera -1/3, 2Mp,Icr,1920*1080;30Fps,Triple Streams, Dc12V &Poe Ip67, Verifocal (2.8Mm-12Mm),Ir Range ;Up To 50M-80Mtr. Ir Anti- Reflection Window ,Micro Sd Card Slot ,Support On Up To 128 Gb Storage , Built –In Bracket <(>,,<)> Ip67 With Smart Functions (Line Crossing Intrusion ,Motion Face Detection , Scene Change Detection 844 9038350 S/F 5M 1/2 Y Gi Pole Eletrical Sor Supplying Fabricating Erecting Light Pole In Cc 1:3:6, With Gi Coating Complete Excluding Cost Of Foundation. (Height Will Be Considered From Finished Driveway Level ) 5Mtr High Single Arm As Per Std Drg. 848 9009937 Sup N Inst 9 Kg Co2 Type Supply, Installation, Testing And Commissioning Of 9 Kg Capacity Isi Marked (Is-2878) Carbon Di-Oxide Type Flat Base Fire Extinguishers, Including Valve, 1 Meter Long Discharge Hose Of Not Less Than 10Mm Dia, Complete In All Respects, Including Initial Fill With Co2 Gas Conforming To Is:307-1966 And With Wall Suspension Brackets(Fixed With Anchor Fastner) With Approved Fixed Signage As Per Code. 852 9038351 S/F 5M Y Gi Pole Eletrical Sor Supplying Fabricating Erecting Light Pole In Cc 1:3:6, With Gi Coating Complete Excluding Cost Of Foundation. (Height Will Be Considered From Finished Driveway Level ) 5Mtr High Y Shaped Arm As Per Std Drg. 854 9029514 S/F Of 90/100 W Led S/F Of 90/100 W Led Flp Fitting Supply And Fixing Of Flp Led Light 90/100 W For Canopy/Pole. Light Fitting Design And Model Of The Make Supplied Should Be Certified By Peso/Cimfr & Bis. 858 7008140 Pump . . Non Space Hose Reel Dispensing Pumps Installation Of Non Space Hose Reel Unit On Existing Canopy Structure Including Necessary Arrangement For Fixing/Hoding The Same And Restoring The Original Shape Of Surroundings Charges Includes Cost For Uplifting Arrangments 863 9037443 Ground Water And Soi Ground Water And Soil Quality Monitoring Within Petrol Pump Selling More Than 300 Kl/Month And More Than 10 Lakh Population Shall Be Conducted By Omcs Once In Two Years Through E (P) Act, 1986 Approved Labs For The Following Parameters From The Nearest Source And Report Submitted To Spcb: 870 9038465 S/F Poe Switch 8Port Providing, Installing N Commissioning Ups Of Approved Make.With Over/ Under Load Protection Complete, With Led Acid Battery. 8 Port ,2Fo Port With Sfp 873 9038463 S/F Unv 8 Ch. Nvr Providing, Installing N Commissioning Ups Of Approved Make.With Over/ Under Load Protection Complete, With Led Acid Battery. 8 Channel Nvr ,I Support Ultra 265/H.265/H.264 Video Formats 8- Channel Input Third- Party Ip Camera Supported With Onvif Con Formance :Profile S, Profile G, Profile C, Profile Q, Profile A, Profiles T, 1-Ch Vga,Hdmi-1 At Up To 4K(3840*2160) Resolution Hdmi / Vga Up To 8 Megapixels Resolution Recording Up To 8 Sata Smart Functions (Line Crossing ,Intrusion ,Motion ,Face Detection,Scene Change Detection . 885 9030276 Godrej Chair Pch7002 Godrej Interior Motion High Back Executive Chair Model No Pch-7002 890 9024897 Pmt Survey . Soil Investigation Soil Investigation By Approved Agency (Iso Certified / Govt. Approved /Nabl Certified Lab/Any Other Approved By Bpcl) Including All Applicable Field Investigations Such As Boring 12 Holes 150 Nb Up To 6 M Depth / Refusalstrata (N Value Greater Than 50) Whichever Earlier, Standardpenetration Test At Every 1.5 M Or As Per Site Conditions, Collecting Disturbed & Undisturbed Soil Samples At Every 1.5 M Depth Or As Per Siteconditions, Determination Depth Of Water Table, Etc. And Laboratoryinvestigations Such As Testing Of Samples Collected From Field(Disturbed / Undisturbed Soil Samples), Sieve Analysis, AtterbergSlimit, Particle Size Analysis, Natural Moisture Content, Wet & Drydensity, Specific Gravity, Tri-Axial Compression, Consolidation, Testing Of Water Sample For Construction Purpose Including For Harmful Salts,Cbr Value, Etc. Or Any Other Required Tests But Not Mentioned Here Forderiving Allowable Bearing Capacity (Abc)For Designing Sales Building, Boundary Wall / Retaining Wall, Culverts ,Trenches, Canopy Foundation, Driveway, Etc. Complete.All Tests Will Be Carried As Per Latest & Relevant Is Codes Of Practiceas Applicable.Item Also Includes Comments / Recommendations Of Expert On Type Offoundation Based On Soil Investigations.Rate Is Inclusive Of Submission Of Complete Report In Three Sets Alongwith Soft Copy In Cd. 901 9016647 Sup N Ins . Air Compressor 3 Hp Providing & Fixing 3 Hp Air Compressor Of Elgi/Ingersoll Rand/Kirloskar150 Litres Capacity 902 9030271 Prefab Septic Tank S/I Of Prefabricated Septic Tank 5000 L/16 User Supply And Installation Of Prefab Septic Tank (Make: Sintex/Approved Make) Capacity 5000 Litres/16 Users Jobs Include Excavation, Backfilling In All Type Of Soils, Rock Including Cover Inlet/ Outlet Connections Etc. All Complete Outlet Of Septic Tank Should Be Connected To The Soak Pit With Necessary Slope, Excavation/Backfilling Etc Complete As Directed At Site 903 9016654 Elc Install N Commission Water Cooler Installation N Commissioning Of Providing & Fixing Water Cooler Voltas/Usha Sriram/Blue Star Or Equivalent Cooling Capacity 80Lph/150 Litre Storage Capacity As Per Direction Of Engineer Incharge Including Voltage Stabilizer( 5 Kva) Of B Urji, Logicstat, Blue Bird Etc Incl Copper Wiring Etc Complete Floor Mounted Including Wall Chiselling, Providing Drain Pipe Etc All 904 9000981 Supply N Instal . . 5 Hp Air Compressor Supply N Installation Of 5 Hp Air Compressor 905 9037420 N2 Inflator-5-100Psi Eletrical Sor Earthing Supply, Transportation And Installation Of N2 Inflator, With Facility Of Dual N2/Air Filling Option, With Digital Display, Filling Range 5-100 Psi Of Approved Mak 909 New Sor Code Retail Retrofit - Replace Refix Pet G Retail Retrofit - Replace Refix Pet G 910 New Sor Code Rvm . . Retro-White Acm Rvm . . Retro-White Acm 912 New Sor Code Retail Supply&Inst. - Thermoform Bpcl Le Retail Supply&Inst. - Thermoform Bpcl Le 971 New Sor Code P&F Of Din Rail Mounted Surge Protection Devise Conforming To Iec 61643-11 For Type 1+2 Protection And Maximun Dischrge Current 50 Ka With Foolowing Configration In Exsting Distribution Board. As Per Required Oem With Nabl/Cpri/Erda Lab Test Report.Surge Supressor- 2 Pole-To Be Used In Voltage Falactuation Cases Only P&F Of Din Rail Mounted Surge Protection Devise Conforming To Iec 61643-11 For Type 1+2 Protection And Maximun Dischrge Current 50 Ka With Foolowing Configration In Exsting Distribution Board. As Per Required Oem With Nabl/Cpri/Erda Lab Test Report.Surge Supressor- 2 Pole-To Be Used In Voltage Falactuation Cases Only 972 New Sor Code S&F Of Din Rail Mounted Surge Protection Devise Conforming To Iec 61643-11 For Type 1+2 Protection And Maximun Dischrge Current 50 Ka With Foolowing Configration In Exsting Distribution Board. As Per Required Oem With Nabl/Cpri/Erda Lab Test Report.Surge Supressor- 2 Pole- 4 Pole-To Be Used In Voltage Falactuation Cases Only S&F Of Din Rail Mounted Surge Protection Devise Conforming To Iec 61643-11 For Type 1+2 Protection And Maximun Dischrge Current 50 Ka With Foolowing Configration In Exsting Distribution Board. As Per Required Oem With Nabl/Cpri/Erda Lab Test Report.Surge Supressor- 2 Pole- 4 Pole-To Be Used In Voltage Falactuation Cases Only 975 9037445 Frp Cover 600 Mm Dia . . . Supply And Installation Of Composite (Frp) Manhole Cover With Frame D400 With 40T Load Bearing Capacity Of All Complete And As Per Drawing & Specification. (Composite Manhole Cover Circular) 600 Mm (Dia-Clear Opening) 976 9037446 Frp Cover 900 Mm Dia . . . Supply And Installation Of Composite (Frp) Manhole Cover With Frame D400 With 40T Load Bearing Capacity Of All Complete And As Per Drawing & Specification. (Composite Manhole Cover Circular) 900 Mm (Dia-Clear Opening) 977 9037516 Frp Cover 600 Mmx600 Supply And Installation Of Composite (Frp) Manhole Cover With Frame D400 With 40T Load Bearing Capacity Of All Complete And As Per Drawing & Specification. (Composite Manhole Cover Square) 600 Mm (Size-Clear Opening) 978 9037517 Frp Cover 900Mmx900M Supply And Installation Of Composite (Frp) Manhole Cover With Frame D400 With 40T Load Bearing Capacity Of All Complete And As Per Drawing & Specification. (Composite Manhole Cover Square) 900 Mm (Size-Clear Opening) 979 New Sor Code Supply And Installation Of Composite (Frp) Manhole Cover With Frame D400 With 25T Load Bearing Capacity Of All Complete And As Per Drawing & Specification. (Composite Manhole Cover Circular) 600 Mm (Dia-Clear Opening) Supply And Installation Of Composite (Frp) Manhole Cover With Frame D400 With 25T Load Bearing Capacity Of All Complete And As Per Drawing & Specification. (Composite Manhole Cover Circular) 600 Mm (Dia-Clear Opening) 980 New Sor Code Supply And Installation Of Composite (Frp) Manhole Cover With Frame D400 With 25T Load Bearing Capacity Of All Complete And As Per Drawing & Specification. (Composite Manhole Cover Circular) 900 Mm (Dia-Clear Opening) Supply And Installation Of Composite (Frp) Manhole Cover With Frame D400 With 25T Load Bearing Capacity Of All Complete And As Per Drawing & Specification. (Composite Manhole Cover Circular) 900 Mm (Dia-Clear Opening) 981 New Sor Code Supply And Installation Of Composite (Frp) Manhole Cover With Frame D400 With 25T Load Bearing Capacity Of All Complete And As Per Drawing & Specification. (Composite Manhole Cover Square) Supply And Installation Of Composite (Frp) Manhole Cover With Frame D400 With 25T Load Bearing Capacity Of All Complete And As Per Drawing & Specification. (Composite Manhole Cover Square) 982 New Sor Code Supply And Installation Of Composite (Frp) Manhole Cover With Frame D400 With 25T Load Bearing Capacity Of All Complete And As Per Drawing & Specification. (Composite Manhole Cover Square) Supply And Installation Of Composite (Frp) Manhole Cover With Frame D400 With 25T Load Bearing Capacity Of All Complete And As Per Drawing & Specification. (Composite Manhole Cover Square) 1076 9019285 . . . Autoflush Urinal Providing And Fixing White Vitreous China Battery Based Infrared Sensor Operated Urinal Of Approx. Size 610 X 390 X 370 Mm Having Pre & Post Flushing With Water ( 250 Ml & 500 Ml Consumption), Having Water Inlet From Back Side, Including Fixing To Wall With Suitable Brackets All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. 1077 9004965 S/I . Hand Driers Automats Supplying N Fixing Of Hand Driers Of The Single Blower Type Automats Or Approved Equivalent Make Automats 1080 9002431 Equipment Hire . Jcb Per Hour Hiring Of Jcbs Per Hour 1081 9002432 Equipment Hire . Road Roller 8-10T Hiring Of Road Rollers 8 - 10 Ton Incl Transportation 1085 9019489 . . . Ro Water Purifier Providing & Installation Of Auto Start/Off Ro Water Purifier Of Eureka Forbes/Kent/Usha Or Equivalent, Having Three Stage Purification Process Comprising Of Sediment Filtrer Candle, Activated Carbon And Ultraviolet Column Capable Of Effectively Removing All Particulate, Chlorine, Organic Impurities And Water Bourne Bacterial And Viral Contamination. The Purifier Should Also Have A Safety Mechanism Of Built In Elecronic Monitoring System To Ensure Complete Purification Of Water Before Allowing The Flow. Min Purifying Capacity=10Lph 1123 New Sor Code Paver Testing As Per Bpcl Tender Specifications- 1 Set (8 Nos) From Nabl Approved Lab/Reputed Institute Paver Testing As Per Bpcl Tender Specifications- 1 Set (8 Nos) From Nabl Approved Lab/Reputed Institute 1124 New Sor Code Godrej Table- Enterprise Without Cpu Hanger Office Desk 1350 W Godrej Table- Enterprise Without Cpu Hanger Office Desk 1350 W 1125 New Sor Code Godrej Table- Unitized - T25 Office Desk Godrej Table- Unitized - T25 Office Desk 1126 New Sor Code 20 L Water Bottle- Portable Drinking Water 20 L Water Bottle- Portable Drinking Water 1128 New Sor Code S&F Of Toilet Sensor For Monitoring Of Odur, Humidity, Temp Etc S&F Of Toilet Sensor For Monitoring Of Odur, Humidity, Temp Etc 1130 New Sor Code S&F Of Fire Alarm System With Necessry Siren Etc S&F Of Fire Alarm System With Necessry Siren Etc 1132 New Sor Code S&F Of Breakaway Reducer For Tokheim Mpd S&F Of Breakaway Reducer For Tokheim Mpd 1133 New Sor Code Sealing Wire For Sample Containers Sealing Wire For Sample Containers 1134 New Sor Code S&F Of Godrej Make- Cash Safe/Chest- Rhino Advanced (79 L) S&F Of Godrej Make- Cash Safe/Chest- Rhino Advanced (79 L) 1135 New Sor Code S&F Of Currency Counting Machine S&F Of Currency Counting Machine 1136 New Sor Code Outdoor Poly Carbonate Electrical Panel Outdoor Poly Carbonate Electrical Panel 1149 New Sor Code Prefab Boundary Wall Of Thickness 50Mm Height 1.2 M Prefab Boundary Wall Of Thickness 50Mm Height 1.2 M 1150 New Sor Code Prefab U Shape Culvert With Cover -1.2Mx1.2M Prefab U Shape Culvert With Cover -1.2Mx1.2M 1152 New Sor Code Water Proofing On Old Structure- Acrylic Coating With Polyster Mesh & Fabric Water Proofing On Old Structure- Acrylic Coating With Polyster Mesh & Fabric
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender