Tender For repair maintenance E&M Services (Electrical) At Abit Residential C Us, Ashok Vihar During Year 2026-27.
Tender Value
48.86 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
7 days left
EMD
97732
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for repair maintenance E&M Services (Electrical) At Abit Residential C Us, Ashok Vihar During Year 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | SH-I (Street & Compound Lighting)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).120 watt |
| 2 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).200 watt |
| 3 | Provision for pole / wall mounted box (300x200x105) mm size made out of (SMC) sheet moulding compound dust & weather proof with front openable hinged type cover with locking arrangement i/c providing & fixing of following accessories on existing pole / wall with suitable arrangement as required.a) 32 Amp 5 Way connector with bakelite base.b) 6 Amp SP MCB 'C' Curve (10 KA) - 1 No.c) Earth Studs - 2 Sets.d) 40 x 5 mm clamp with 2 Nos. 3/8\\" Nut & Bolts - 1 Set as required.e) Push & Clip handle to close/open - 1 No. |
| 4 | Supplying, Installation, testing and commissioning of prewired 35-40 Watt LED post top lantern fitting having die cast aluminium body with minimum 100 lumens per watt suitable for cool day-light white having CCT 5700K with IP 65 (including dismantling the old fitting if any) complete with all accessories etc. directly on existing pole , including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required |
| 5 | Dismantling of existing damage GI pole from existing foundation including disconnection of cable, wire, removing LED fitting, brackets and Shifting of following height GI pole to store i/c reinstallation on existing/new foundation. The nut-bolts of the foundation shall be covered with cement concrete CC work 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) on Nut Bolt upto a height of 30 cm. above foundation etc. complete as required.5 to 6 meter height |
| 6 | Providing and laying in position 1:2:4 reinforced cement concrete foundation of size 500 mm.(L) X 500 mm. wide and 1200 mm. deep i/c excavation of earth in hard rock, providing cutting, bending and placing in position, steel reinforcement of cold twisted bars of 12 mm. dia- 1300mm long (approx)- 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia - 2000mm (approx) - 10nos. (with equal spacing) for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete as required with positioning of foundation bolts (as per item below) and providing 63 mm. (O.D) DWC, HDPE Pipe minimum 1 mtr. for cable entry & exit as required. (for 5 meter height pole) |
| 7 | Fabrication, Supplying & Fixing of Hot molded SMC (Sheet molded Compound) street light pole termination window cover of assorted size for the existing street light poles complete with rubber gasket. G.I. Mounting strip and bolt for mounting,locking arrangement, color steel grey. Suitable for 5/8/10/12 mtr G.I. Octagonal Pole (having thikness 3mm) |
| 8 | Fabrication, Designing, Supplying & Fixing of hot dip Galvanized arm bracket of suitable length single/double over hang having minimum 50 cm to 100 cm length with tightening bolt and making 1 earth stud suitable size/type as desired by Engineer-in-charge to connect luminaire earth wire etc. (Design to be approved by Engineer-in- Charge). |
| 9 | Supplying and fixing 4 Nos. 16 mm(minimum) dia X 650 mm(minimum) long GI foundation bolt (EN8grade) with nuts, washer including 2 Nos. template of 3 mm thick size 200 X 200 mm. with 4 Nos. 20 mm. dia holes (or suitable for existing holes), to match with PCD of Pole base plate as required. (For 5 Mtr. Pole) |
| 10 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE aluminium Conductor armoured power cable of 1.1 kV grade of following size in the existing RCC/ HUME/METAL/DWC/GI pipe i/c making end termination with suitable size aluminium lugs etc. as required.4 x 16 sq. mm |
| 11 | 3.5 x 70 sq. mm |
| 12 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 13 | Painting of 5.0 metre high GI/MS street light pole with two coats of approved synthetic enamel paint of aluminium (silver) shade over one coat of red oxide zinc chromate primer after thorough cleaning of the existing surface by scraping, rubbing with emery paper/wire brush and removing rust, dirt and loose paint, including painting of bracket arm wherever provided, complete in all respects. The item also includes numbering of each pole with 100 mm high black enamel painted numerals using approved stencil on two opposite sides of the pole as directed by the Engineer-in-Charge. |
| 14 | Repairing and making good the damaged RCC/brick masonry foundation of existing street light pole by dismantling loose and damaged concrete/plaster, cleaning the surface, applying bonding agent where required, providing cement concrete/micro concrete/polymer modified mortar as required to restore the original shape and strength, curing, providing cement plaster (1:4), preparing the surface, applying one coat of exterior primer and two or more coats of approved weatherproof exterior paint of approved shade/colour to match the existing surroundings, including filling cracks, finishing etc. as requred. |
| 15 | Fabrication, Supplying and installation of outdoor type cubical feeder pillar of suitable size not less than 300mm deep and 0.75 mtr × 0.75 mtr made out of M.s. sheet 2mm thick duly compartmentalised having 4 strip busbars of 300Amp capacity double door with two nos. godown locking (inter lock in panel ) arrangement for protection from theft & duly fixed on M.S. angle iron frame work of size 35 mm × 35 mm × 5 mm (NS) having 45cm long legs out of which 30 cm duly grouted in cement concrete 1:2:4(1 cement :2 sand: 4 stone aggregate 20mm) and having following accessories mounted inside the cubical panel i/c connection, inter connection with aluminium busbar & thimbles, earthing with aluminium strip & two nos. earth studs & duly painted with one coat of red oxide & two coat of suoerior quality enamel paint complete etc. as reqd i/c Supplying & Fixing of following aceessories in the cubical panel board/feeder pillar including connection testing etc. as reqd. a) 125A, 36KA, FPMCCB with spreader link ( Thermal magnetic release)- 1 No. as incomerb) 100A, 16KA TPMCCB with spreader link (Thermo magnetic release)- 1 No. as outgoingc) 63A, TP&N MCB - 2 Nos.d) Voltmeter(0-500 volt) with selector switch.e) Ammeter(0-100 Amp) with selector switch & 100/5 Amp ratio CTs.f) LED indicating light Modular MCB type - 1 set (for RYB)g) Power contactor : 3 pole , 40 A, 415 volt (MNX-40)h) Astromini timer - 01 Seti) Danger notice plate- 01 No.etc. complete as required. |
| 16 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 17 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 18 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 19 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 20 | Supplying and drawing following sizes of PVC insulated copper conductor multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable copper lugs connections complete i/c credit / buyback for old dismantled material i/c dismantling as on where it is basis etc complete as required .3 core 1.5 sq.mm |
| 21 | Supplying, installation, testing & commissioning of cubical type, extensible, bolted construction LT Panel suitable for 415 V, 3 Phase, 4 wire 50 Hz AC supply system front surface area not less than 2.00 sq.mtr fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work / load bearing members, 1.6 mm thick for doors and covers, 3mm thick for gland plates including cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 400 Amp capacity extensible type TPN Aluminium bus bars of high conductivity, DMC / SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 4.7 mm thick (ISMC 100); indication shall be done in transportable sections, entire panel shall have one common tinned copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth studs / terminals, solid connections from main bus bar to switch gears with required size of aluminium bars and control wiring with 2.5 Sq.mm. FRLS / HFFR grade PVC insulated copper conductor single core cable, cable alleys, cable gland plates in two or more haves, including providing following switch gears :i) Incoming -1250 Amps. 4 Pole, 36 KA, MCCB (Ics = 100 % Icu) T/M Release (O/C, S/C) with Rotary handle & Spreader link. - 1 No.Intelligent multifunction digital meter to read V, A, KVA, KWH, PF, Hz etc. having RS 485 port and compatible to PC with modbus / back net protocol with 3 Nos. resin cast CTs of 400 / 5 A class 1.0 accuracy and 15 VA burden - 1 No.3Nos. CT's MCCB 'ON / OFF / TRIP' indicating light with back up MCB, test terminal block, circuits as per standard practice, auxiliary contact / contactors for positive electrical interlocking of MCCBs etc. as required. - 1 Set.ii) Incoming -2250 Amps. 4 Pole, 36 KA, MCCB (Ics = 100 % Icu) T/M Release (O/C, S/C) with Rotary handle & Spreader link. - 1 No.Intelligent multifunction digital meter to read V, A, KVA, KWH, PF, Hz etc. having RS 485 port and compatible to PC with modbus / back net protocol with 3 Nos. resin cast CTs of 400 / 5 A class 1.0 accuracy and 15 VA burden - 1 No.3Nos. CT's MCCB 'ON / OFF / TRIP' indicating light with back up MCB, test terminal block, circuits as per standard practice, auxiliary contact / contactors for positive electrical interlocking of MCCBs etc. as required. - 1 Set.ON LOAD CHANGEOVER SWITCH200A 4Pole On load Changeover Switch-1 No. BUS BARTPN Aluminium bus bars (having 100% Neutral) of minimum of 400 Amps. capacity with heat shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals for complete cross section etc. for withstanding fault level of 31 MVA for 1 Sec. - 1 Set. OUTGOINGS100 Amps. 4 Pole, 25 KA, MCCB (Ics = 100 % Icu) T/M Release (O/C, S/C) with Rotary handle & Spreader link. - 7 Nos.63 Amps. 4 Pole, 25 KA, MCCB (Ics = 100 % Icu) T/M Release (O/C, S/C) with Rotary handle & Spreader link. - 1 Nos.Complete Panel as described above |
| 22 | Supplying of one number XLPE insulated and PVC sheathed aluminium conductor, armoured underground power cable of 1.1 KV grade of following size and in following manner on wall / surface as required.3.5 x 150 sq. mm (clamped with 1mm thick saddle) |
| 23 | SH-II (EI Work)Operation and maintenance of electrical and mechanical installations at DTE Staff Qtrs, Sawan Park on all working days including sunday and holidays or as per directions of Engineer-in-charge, terms and conditions etc. as required for operation and maintenance of EI and Fans,Pump sets etc.(1) Wireman cum Pump Operator - 3 Nos. (One in each shift : 6 AM to 2 PM , 2 PM to 10 PM and 10 PM to 6 AM.)(2) Khallasi - 1 No. ( 9 AM to 5 PM in General shift) |
| 24 | Supplying & lowering of 15 HP/11kw Open well submersible pump set capable of delivering 36-22 LPS at a head of 10-34 mtrs for operation on 415 volts, 3 phase, 50 Hz, AC supply, in the existing open well with the help of chain pulley and tripod stand i/c providing of GI nipple, flanges, GI nut and bolt, gasket and providing & fixing of cable jointing kit etc as reqd. |
| 25 | SITC of 15 HP / 11 kw fully automatic star delta (with wideband coil) Submersible Pump Starter having relay range 13-22 suitable for 415V 50Hz, 3 phase motor complete with sheet enclouser, ammeter, voltmeter, start stop push button, on off LED indication lamp, auto mannual slector switch and all other accessories including connections & testing etc complete as required. |
| 26 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia |
| 27 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia |
| 28 | Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm |
| 29 | Lifting of existing submersible bore well / open well 3 HP to 15 HP capacity Pump set from the bore well with the help of chain pulley block & tripod stand i/c cartage charge at site from the work shop. |
| 30 | Lowering of 3 HP to 15 HP capacity bore well/open well pumpset in the bore well with the help of chain pulley block and tripod stand i/c cartage charge pump set from work shop to site. |
| 31 | Repairing of Submersible/monobloc Pumpset of following capacity i/c replacement of mechanical seal TC/TC upper, mechanical seal TC/TC lower, ball bearing, 'O' Ring, stamping repairing, including dismantling, assembling, commissioning and testing the same on load after making electric connections at site i/c site visit by Engineer and to & fro from site to workshop & back to site etc. complete with credit of dismantle etc as required.15HP |
| 32 | Rewinding of following capacity Pumps, 3 phase multistage submersible / monoblock-submersible Pump-set with suitable size water proof copper conductor wire and dismantling the existing burnt wire, reassembling the pump and to & fro from site to workshop & back to site, etc. i/c buy back of dismantle materials i/c connection, testing etc as reqd.15 HP |
| 33 | Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required.3 Core 2.5 Sq mm Flat Cable |
| 34 | SH-III (Supply of materials) Note:- No labour is considered for fixing of these items5/6 A switch (Modular type) |
| 35 | 15/16 A switch (Modular type) |
| 36 | 3 pin 5/6 A socket outlet (Modular type) |
| 37 | 6 pin 15/16 A socket outlet (Modular type) |
| 38 | Step Type Modular Fan Regulator (switch type) |
| 39 | 5/6 A switch (Piano Type) |
| 40 | 15/16 A switch (Piano type) |
| 41 | 3 pin 5/6 A socket outlet (Piano type) |
| 42 | 6 pin 15/16 A socket outlet (Piano type) |
| 43 | Bell Push (Piano type) |
| 44 | PVC Batten/ Angle Holder |
| 45 | 1 or 2 Module Cover plate |
| 46 | 3 Module Cover plate |
| 47 | 6 Module Cover plate |
| 48 | 8 Module Cover plate |
| 49 | 12 Module Cover plate |
| 50 | 1.5 Sq.mm. ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 51 | 4 Sq.mm. ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 52 | 6A to 32 A, ratings, SP MCB, \\"C\\" curve, 10 KA breaking capacity |
| 53 | 6A to 32 A, ratings, SPN MCB, \\"C\\" curve, 10 KA breaking capacity |
| 54 | 100 A, 16 kA,TPMCCB |
| 55 | Step Type Fan Regulator (Socket Type Piano ) |
| 56 | 40/63 Amp TP MCB 10 kA rating \\"C\\" Curve |
| 57 | 63 Amp FP 10 MCB 10 kA rating \\"C\\" Curve |
| 58 | 300 mm sweep 900 rpm heavy duty exhaust fan |
| 59 | Aluminium louvers/shutters complete with frame suitable for 300mm sweep exhaust fan etc. as reqd. |
| 60 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, etc. complete as req |
| 61 | 18- 22 watt 4 feet Indoor commercial LED batten fitting (System lumen efficacy ≥105 <120 lm/Watt) with Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm). |
| 62 | 36 watt 4 feet Indoor commercial LED batten fitting (System lumen efficacy ≥105 <120 lm/Watt) with Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm). |
| 63 | 18 Watt LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) of Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector. |
| 64 | 2.5 MFD capacitor |
| 65 | SH-IV (Credit of dismantle materials) Less credit for following dismantle material received from the work5/6 A distorted switch (Modular/Piano type) |
| 66 | 15/16 A distorted switch (Modular/Piano type) |
| 67 | 5/6 A distorted socket outlet (Modular/Piano type) |
| 68 | 15/16 A distorted socket outlet (Modular/Piano type) |
| 69 | Bell Push distorted |
| 70 | Fan Regulator (Modular/Piano type) |
| 71 | 1/2/3/6/8/12 Modular damaged cover Plate |
| 72 | 6-32A SP/DP MCB distorted/damaged |
| 73 | 40/63A DP/SPN/TPN/FP/ MCB distorted/damaged |
| 74 | Assorted size MCCB distorted/damaged |
| 75 | Assorted size Copper wire cut pieces |
| 76 | 22/36watt LED fittings distorted damaged |
| 77 | 300 mm damaged exhaust fan |
| 78 | 1200 mm damaged ceiling fan |
| 79 | 2.50 MFD capacitor |
| 80 | Main Panel i/c accessories distorted/damaged |
| 81 | Aluminium armourd cable |
| 82 | 80W/120W/150Watt LED Street/ Flood lights fittings distorted/damaged |
| 83 | 63 mm DWC pipe |
| 84 | 15 HP submersible pump distorted/damaged |
| 85 | 15 HP Star delta starter distorted/damaged |
| 86 | Sluice valve 65 mm distorted/damaged |
| 87 | NON - RETURN VALVE 65 mm distorted/damaged |
| 88 | GI Pipe 65 mm distorted/damaged |
| 89 | Pole box distorted/damaged |
| 90 | 1.5 sq.mm copper cable distorted/damaged Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 12, 2026
11:30 IST
Tender Published
Tender notice published.
TodayAug 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysAug 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender